HomeMy WebLinkAboutMinutes Mechanical/Plumbing Advisory Board - 08/14/2014 NOTICE OF REGULAR MEETING Mechanical/Plumbing Advisory Board August 14, 2014 Time: 2:00 p.m. 2406 Leopard ❖ Corpus Christi, Texas Development Services 31 Floor, Fire Department Training Room Minutes I. Call to Order The meeting was called to order at 2:10 IL Roll Call- Present:James Mokry, David Matthews,Clinton Bailey, Gilbert Canales, Ronald Klepac, Karim Salighedar Absent: Billy rgin, Julio Sanchez and Staccy Gallagher Staff Present: Gene Delauro and Yvette Francis 111. Approval of Absences: January 29, 2014, Regular Meeting Motion to approve the absences 6-0 IV. Approval of Minutes: January 29, 2014,Regular Meeting Approval of minutes 6-0 V. Discussion and possible action regarding the Reduction of Lead in Drinking Water Act in relation to the use of hose bibs with lead content for potable water. Mr. Delauro explained that the two hose bibs that we are passing out is what we have been seeing in the field. Mr. Delauro explained that the Reduction of Lead in Drinking Water Act came in to enactment in January 2014. The Act states that if it can be used for human consumption that it has to be lead free, Currently hose hubs are being installed on the exterior of residential homes and we need to determine if it can possibly be used for human consumption. Page 11 question 2 1, someone specially asks the same question and the answer fro the EPA says as long as it used exclusively for non-potable services. Labeling being used one has a tag and the other has a stamp on the handle. Mr. Klepac says most of them are white and labeled do not drink in the ball valves. Mr. Bailey said once the tag is removed there is not way to tell if it has lead or not. Mr. Mokryfeels that they should let them go and install them, because in the tune they will no longer be allowing them so they will no longer be producing them. He would not throw out the hose bibs he has in stock and personally would not drink out of a hose bib. Mr. Mokry,feels that we maybe able to use a brass tag that states not for drinking purpose sothat it does not fade over time. Mr. Delauro mentioned that lead free is available, but a little bit more costly. TC EQ has not adopted this requirement, but the federal government has. Mr. Delauro is looking at it from a liablility standpoint, where someone claims that they are harmed when we have a federatl law stating that is not allowed. Mr. Delauro feels that on a Commerical project the owner of the building can control what the hose bib is used for, and that in residential a home owner may not be able to. r. Mokryfeel that the definitionfor a hose bib as defined in the code is it intended for washing cars,fillig your pool, etc. Mr. Mokryfeels that it is intended for using as maintenance in your yard. r. Bailey wanted to know what the date that everyone has to use it and no longer sell or manufacture lead hose bibs. Mr. Delauro said January 4, 2014 after a 3 year period. Mr. Bailey explained that lead is used to help hold the brass together.Mr. Delauro sateted that the lead content went from 8%to .02 1X-,. So there is still lead, but not enough to do harm. Bailey what if you require the to be on new installations. Delauro discussion is primarily on new residential construction. Matthews if you say Commerical isokay, residential new construction needs the lead free, Bailey we should say that all new. Matthews replacement or repair you are saying you can still use lead bibs.Mokry what are the brass City water meters made out of. So, if they are not lead free the meters that the water is currently running through that supplies the house has lead content. Matthews but the new law requires that they be leadfinee so the new meters will probably be lead free, 11 Mokry thinks we should give all of the plumbers notice or have a meeting once the State adopts this law, but until the State or City says then they should still be allowed. Delauro U7CEQ adopts this they always give time for enforcement. What direction would the Board like to take? Matthews is a hose bib intended for potable water and rgin and Mokryfeel it is not. Delauro it is the Boards decision that we should allow these lead bib with proper lables. If TCEQ comes back with the law we will bring this back to Board. rgin all commericals job state that all devices need to be lead free. Canales it's the manufacture and there are more manufactures that have lead free bibs that are sold here. Recommendation-Because the hose bib is not intended for potable water we will still allow these, but in any application that the hose bib is used for potable water it will not be allowed, The Board recomendtion is unanimous 6-0 V . Discussion and possible action regarding a possible local amendment to the 2009 International Residential Code Section 2705.1 regarding fixture clearances. Delauro clearance issues with the 15 inch clearance espically in double vanitys. HBA has asked if we could ask the Boardfor a possible reduction on the lavatory clearance 12 inch minimum. Commentary states the 15 inch is for cleaning and sanitary purposes mokry 15 from the center of the bowl? rgin they should get with the plumber. Matthews it should befroin the edge of the bowl to the wall, Delauro what is a code measurementfrom the bowl to the wall. Mokry 3 inches. Matthews 4 inches. rgin 4 inches. Measurefrom the side wall of the lavatory to the wall needs to be at least 4 inches. sdfads VII. Discussion and possible action regarding a possible local amendment to the 2009 International Fuel as Code Section 102.9 regarding clearance requirements for gas meters. Delauro as department has concerns about the gas meters being to close to energized electrical equipment. If the vent is venting gas and the electrical equipment sparks there could be an issue. 3foot of clearance fro any electrical clearance.Delauro 3foot horizontal clearance, he doesn't think that there is a vertical requirement. Larginfeels that there should be nothing above or beside the gas meter. Delaurojeels that there sholdn't be operable windows or doors. Canales are we talking about new installations and not change outs. Matthews what kind of clearance is in the code, Delauro there is none, but it does talk about the municipality set the quidelines. Motion to recommend is to except the gas meter clearance with the following amendment: Remove the water spigots.Matthews, rgin seconded 6-0. V111. Building Official's Report A. Staff update Staff changes. Building Official resign September 26. Interim Director leaving 8122, new Director in September, Yvette Floodplain Manager, Christopher Miller resigned as of 8122, Guadalupe Chavarria plumbing inspector has returned as a plumbing inspector. 5- licensed plumbing inspectors James, Ernest, Joseph, Guadalupe and Katie.Plumbing inspectors are doing mechanical inspectoirs. James will go back to irrigation, backflow and commercial plan review, B. Permit recap Gene Dealuro-permit recap 80 new residential homes Commercial- valuations exceed what we had last year for the year last year, Public Comments No one addressed the Board at public comment. X. Identify items to be placed on next agenda Interpretation of the Code realting to the requirement of installing locking caps on the access ports of air conditioning equipment. Dry wells for condensate. (soil engineering requir ents) A,djourtl3:13 Presiding Officer