HomeMy WebLinkAboutC2001-363 Vol 2 - 1/1/1900
.
.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
-
C0S~
2 ]
VOLUME
2
OF
S TAT ION
DATA
SHE E T S
INS T RUM E N T
I N D E X
AND
D E MOL I T ION
P HOT 0 G RAP H S
FOR
WASTEWATER MICROWAVE COMMUNICATION SYSTEM
PREPARED BY:
BATH ENGINEERING GROUP
5656 S. STAPLES STE. 110
CORPUS CHRISTI, TX 78411
PH: (361) 992-2284
FAX: (361) 992-2287
For
DEPARTMENT OF ENGINEERING SERVICES
CITY OF CORPUS CHRISTI, TEXAS
Phone: 361/880-3500
Fax: 361/880-3501
I PROJECT NO: 7100
I DRAWING NO: STL-123
VOLUME
2
OF
2
S TAT ION
D A T A
SHE E T S
INS T RUM E N T
I N D E X
AND
D E MOL I T ION
P HOT 0 G RAP H S
FOR
WASTEWATER MICROWAVE COMMUNICATION SYSTEM
PREPARED BY:
BATH ENGINEERING GROUP
5656 S. STAPLES STE. 110
CORPUS CHRISTI, TX 78411
PH: (361) 992-2284
FAX: (361) 992-2287
For
DEPARTMENT OF ENGINEERING SERVICES
CITY OF CORPUS CHRISTI, TEXAS
Phone: 361/880-3500
Fax: 361/880-3501
I PROJECT NO: 7100
I DRAWING NO: STL-123
. n
1'1'
11l
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1001
BROADWAY WWTP
. n
[1'
11f
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO. 1001
BROADWAY WWTP
STATION TYPE: Wastewater Treatment Plant
ADDRESS: 1402 West Broadway
LATITUDE: N27048.199'
,
,
..___._______.____...______...__..._n "~______________.__.
:~~~~~;~D~~u~~i~:~~::o~rbo~~~idge ~_________j
! ____.__.__.___"__________..n____.______.___._.__.__ _......__..._.___.__j
PHYSICAL DESCRIPTION:
-
The WWTP is accessed from a service driveway and is surrounded by a chain link security fence.
Existing RTU is located in the Electrical/Conference Building. The building is a masonry brick building
housing the RTU and electrical equipment in one of the rooms, Alarms from Lift pumps are hard-wired
to the building from Lift station. All alarms are currently reported through the UHF radio system,
Vehicle access to the Building is possible from three sides,
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 25 ft. - Azimuth: 1960
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1001-1 Power Failure A
1001-2 Power Failure B
1001-3 Chlorine Leak
1001-4 High Level
1001-5 Bar Screen #1 or #2
1001-6 Power / Mag / Motor Failure #1
1001-7 Power / Mag / Motor Failure #2
1001-8 Power / Mag / Motor Failure #3
1001-9 Power / Mag / Motor Failure #4
1001-10 Final Effluent Motor Failure #1 or #2
1001-11 Final Effluent Motor Failure #3 or #4
1001-12 Relift Motor Failure #1, #2, #3, or #4
08/14/01 3:47 PM
Station Data Sheet.doc
_ r
-
STATION NO: 1001
BROADWAY WWTP
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 13
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-1001A Main Power Failure A NEW Phase Failure Monitor Pump Control 01 Lift station Bubbler C.P.
Relay Panel
JS-1001B Main Power Failure B NEW Phase Failure Monitor Pump Control 01 Lift station Bubbler C.P.
Relay Panel
JS-1001Z RTU Glrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LSH-1001 Wet Well High Level EXISTING Control Relay Pump Control 01 Lift station Bubbler Control Panel
Panel
XA-1001A Chlorine Leak EXISTING Control Relay Pump Control 01 Lift station Bubbler C,P.
Panel
XA-1001B Bar Screen #1 & #2 EXISTING Control Relay Pump Control 01 Lift station Bubbler C.P.
Panel
XS-1001A Final Effluent Motor 1 & 2 EXISTING (2) Control Relays Pump Control 01 Electrical/Conference Room
Failure Panel
XS-1001B Final Effluent Motor 3 & 4 EXISTING (2) Control Relays Pump Control 01 Electrical/Conference Room
Failure Panel
XS-1001C Relift Motor Fail 1 & 2 EXISTING (4) Control Relays Pump Control 01 Electrical/Conference Room
Panel
YS-1001A Pump #1 Trouble EXISTING (3) Control Relays Pump ControJ 01 Lift station Bubbler C,P.
Panel
YS-1001B Pump #2 Trouble EXISTING (3) Control Relays Pump Control 01 Lift station Bubbler C,P.
Panel
YS-1001C Pump #3 Trouble EXISTING (3) Control Relays Pump Control 01 Lift station Bubbler C.P.
Panel
YS-1001D Pump #4 Trouble EXISTING (3) Control Relays Pump Control 01 Lift station Bubbler C.P.
Panel
-- -,,- .--
Station Instrument Index Report
08/13/2001 05:43 PM
-
-
-
ELECTRICAL!
CONFERENCE
BLDG.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
MICROWAVE COMMUNlCAll0N SYSTEM
CONSTRUCTION PHOTOGRAPH
1001 - BROADWAY WWTP
DATE: 03/2000 SHEET 1 OF 2
"
~
o
:>
w
"
<>
"
It II Ii II CORPUS CHRISTI, TX. (J6O> 99'-""
II I [l PASO. TX (915) 534-91'0
ENGINEERING CORPORATION SAlT lAKE CITY, Uf. (801) 261-14~
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO,: 1075
SCALE: N.T.S.
DR: DAILEY
.
I
PROJECT NO. 7100
Ifl
ATS
RTU
PANEL
o DISCONNECT POWER, ANTENNA AND ALARM WIRING, REMOVE RTU PANEL.
"
"
o
N
o
:>
w
o
;;
o
1==1 Ii II
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, lX. (J61) 992-2284
El PASO, IX (91~) 534-9110
SAlT lAKE CITY, Uf. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
1001 - BROADWAY ~p
DATE: 03/2000 SHEET 2 OF 2
JOB NO,: 1075
SCALE: N,T.S,
DR: DAILEY
II n
II'
.
I1l
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
STATION NO.
1002
050 WWTP
.
I
...."
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1002
OSO WWTP
STATION TYPE: Wastewater Treatment Plant
,
;
i
._.__.._--~_._-~_.. ..._....._----_.._.....__._._-~
LOCALE: Corner of Ennis Joslin & Nile i
~
ADDRESS: 501 Nile
LATITUDE: N27042,592'
......"..-.--.----~i
,
i LONGITUDE: W97020.324'
PHYSICAL DESCRIPTION:
The WWTP is accessed from a service driveway and is surrounded by a chain link security fence. No
existing RTU is installed.
~
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2830
~
EXISTING STATION ALARMS:
(NO ALARMS)
08/14/01 3:47 PM
Station Data Sheet.doc
STATION NO: 1002
OSO WWTP
STATION INSTRUMENT INDEX:
TAG NO,
[~S-1002Z
SERVICE DESCRIPTION
RTU CIrI Pwr Failure
Station Instrument Index Report
. r
I .. !
DIGITAL INPUTS: 1
ANALOG INPUTS: 0
FIELD DEVICE
120VAC Digital Input
TIE-IN LOCATION
RTU Panel 01
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
08/13/200105:43 PM
1'1'
-
-
-
-
-
1. THIS PICTURE IS OF BLOWER HOUSE No.4. AND IS FOR INFORMATION ONLY,
THERE IS NO DEMOLITION WORK AT THIS SITE.
~
o
:>
w
"
N
"
"
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER OEPT.
PROJECT NO. 7100
CORf'US CHRISn. TX. (361) 992-2284
[L PASO, TX (915) 534-9110
SAlT LAKE CltY,UT. (801)261-14~
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1002 - 050 WWTP
DATE: 03/2000 SHEET 1 OF 1
JOB NO,: 1075
SCALE: N.T,S.
DR: DAILEY
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
STATION NO.
1003
GREENWOOD WWTP
.
.
....
r
-
~
~
-
~
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO.1 003
GREENWOOD WWTP
STATION TYPE: Wastewater Treatment Plant
,
I. .. ..-.--.-........-----~--.---..-.-.......-.....-..--.,
i LOCALE: C~rne~~~=:~\V~Od and_~.:r~~~~~._..!
ADDRESS: 1541 Saratoga Blvd.
LATITUDE: N27043.259'
! LONGITUDE: W97027,383'
,
_-'.._.__.....__......._.."u__ ..... ._._._____.__..,..__.___~____________~_______.._._.._._.._".............."'._..__.......__...._____.
PHYSICAL DESCRIPTION:
The WWTP is accessed from a service driveway and is surrounded by a chain link security fence. No
existing RTU is installed.
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 12 ft, - Azimuth: 7r
EXISTING STATION ALARMS:
(NO ALARMS)
08/14/01 3:47 PM
Station Data Sheet. doc
.
.
11'
STATION NO: 1003
GREENWOOD WWTP
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 0
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
EAL-167 Power Fail MCC-3 EXISTING Phase Failure Monitor PlC Control Panel COMM Alarm status obtained from
Relay existing PLC via comm link
EAL-168 Power Fail MCC-4 EXISTING Phase Failure Monitor PlC Control Panel COMM Alarm status obtained from
Relay existing PLC via comm link
LSH-122 Lift Station Wet Well High EXISTING Float Switch PLC Control Panel COMM Alarm status obtained from
level existing PLC via comm link
Station Instrument Index Report
08/13/2001 05:43 PM
_ r
~"
.
~
-
-
-
-
1, THIS PICTURE IS OF CONTROL ROOM No. 1. AND IS FOR INFORMATION ONLY,
THERE IS NO DEMOLITION WORK AT THIS SITE.
-
~
o
,.
w
o
..,
o
o
II II Ii II CORPuS CHRISTI, TX. (361) 992-"84
II I [l PASO, TX (915) 534-9110
ENGINEERING CORPORATION SALT lAKE CI1Y, UT. (eol) 261-14~
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T,S.
MICROWAVE COMMUNlCAll0N SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1003 - GREENWOOD WWTP
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
II r
11'
Tll
1. THIS PICTURE IS OF CONTROL ROOM NO.1, AND IS FOR INFORMATION ONLY.
THERE IS NO DEMOLITION WORK AT THIS SITE.
~
o
N
o
:>
w
o
~
o
o
11111i II CORPUS Qt'"" 1X. (361) 992-""
I tiEL PASO. TX (915) 534-9110
SALT LAK[ CITY. Uf. (SOl> 261-1455
ENGINEERING CORPORATION
CITY OF CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1003 - GREENWOOD WWTP
DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
.
_ rT
-
~
~
~
~
~
~
~
.
_ PI
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1004
ALLISON WWTP
,...
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO. 1004
ALLISON WWTP
STATION TYPE: Wastewater Treatment Plant
LATITUDE: N27051 ,325'
I LOCALE:Nortlieast oflnlers.eCtlon oflH37 & i
I McKinzie '
!.__..~~-_.."."-----_.._.._---~_.__._--_.._.._.,.~------~-------1
i LONGITUDE: W97033,995' I
ADDRESS: 4101 Allison Drive
-
PHYSICAL DESCRIPTION:
The WWTP is accessed from a service driveway and is surrounded by a chain link security fence.
Existing RTU is located in the Control Building. The building is a masonry brick building housing the
RTU and annunciator in one of the rooms. Plant alarms are hard-wired to the annunciator and then
routed to the RTU, Vehicle access to the Control Building is possible from two sides,
ANTENNA SUPPORT:
Pole - Wood, 45 ft, Class 5 (New)
Antenna Mounting Elevation: 40 ft. - Azimuth: 1350
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1004-1 High Levell Sludge #1 or #2
1004-2 Power Failure I Blower
1004-3 Clairifier Failure
1004-4 Blower Pressure Failure
.-
08/14/01 3:47PM
Station Data Sheet.doc
. n
II'
I1T
STATION NO: 1004
ALLISON WWTP
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 5
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1004 Power Failure! Blower EXISTING (2) Control Relays Annunciator DI
Cabinet
JS-1004Z RTU CtrI Pwr Failure NEW 120VAC Digitallnpu1 RTU Panel DI
LSH-1004 Wet Well High Level EXISTING Control Relay Annunciator DI
Cabinet
XS-1004A Clarifier Failure EXISTING Control Relay Annunciator DI
Cabinet
XS-1004B Blower Pressure Failure EXISTING Control Relay Annunciator DI
Cabinet
-----
Station Instrument Index Report
0811312001 05:43 PM
.
.
I
llT
-
-
OFFICE/CONTROL BLDG.
DIRECTIONAL
ANTENNA
-
~
~
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
~
o
"
w
o
..
o
o
II II Ii II COllP\JS CH'OS" TX. (J61) "'-228'
II I n PASO. TX (gl!l) 534-9110
SAlT LAKf CITY. UT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
1004 - ALLISON WWTP
DATE: 03/2000 SHEET 1 OF 2
DR: DAILEY
.'
II
[1'
.
T1T
RTU
PANEL
LAB
ANNUNCIATOR
t
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
[i
o
N
o
"
~
o
..
8
II II Ii II CORPUS CHOSTI. TX. (361) "2-2,,,
II I n PASO. T. (915) 534-9110
ENGINEERINC CORPORATION WT LAKE CITY, Uf. (BOI) 261-14~
CITY Of" CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
1004 - ALLISON WWTP
DATE: 03/2000 SHEET 2 OF 2
DR: DAILEY
.
I
'"
""T
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1005
LAGUNA MADRE WWTP
. r I I ' 1 ~"'..,
l'T
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
51 A liON NO.1 005
LAGUNA MADRE WWTP
STATION TYPE: Wastewater Treatment Plant
I
i LOCALE: East of Naval Air Station Drive
, ,. ,. -------~--_.__.__.__._----------_._--_..,._..,.._._.,_.-._._.__.~
I,. LONGITUDE: W97016,323' i
.__...,._-_._-----~--_.._._..,.._-_._._-----------------------_.._--_..._._._._-~
ADDRESS: 201 Jester Street
LATITUDE: N27040.297'
PHYSICAL DESCRIPTION:
-
The WWTP is accessed from a service driveway and is surrounded by a chain link security fence.
Existing RTU is located in the Control Building. The building is a masonry brick building housing the
RTU in one of the rooms. Plant alarms are hard-wired to Control building and are currently reported
through the UHF radio system. Vehicle access to the Control Building is possible from two sides.
-
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2920
EXISTING STATION ALARMS:
-
ALARM NO DESCRIPTION
1005-1 Wetwell High Level
1005-2 Main Power Failure
1005-3 Blower / Clairifier Failure
1005-4 Motor #1, #2, & #3 Failure
08/14/01 3:47 PM
Station Data Sheet.doc
. r
.
11"1
STATION NO: 1005
LAGUNA MADRE WWTP
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 5
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1005 Main Power Failure EXISTING Control Relay Existing RTU DI
JS-1005Z RTU CIrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LSH-1005 WeVDry Well High Level EXISTiNG Float Switch RTU Panel DI Intrinsically safe barrier relay
required
XS-1005A . Blower/Clarifier Failure EXISTING Control Relay Existing RTU DI
XS-1005B Lift Pump Motor 1,2,3 Fail EXISTING Control Relay Existing RTU DI
Station Instrument Index Report
08/13/2001 05:43 PM
OFFICE/CONTROL BLDG.
DIRECTIONAL
ANTENNA
.
-
~
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
;:;
"
w
o
on
8
,....
I, II Ii II c-..s 0<RISl' 1X. (361) 99'-"84
II I [L PASO, TI (915) 534-9110
~TLAK[Ct1Y.UT. (8(11)261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE; N.T,S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
1005 - LAGUNA MADRE ~p
DATE; 03/2000 SHEET 1 OF 2
DR; DAILEY
~
.
1
rr
OFFICE
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
~
...
o
'"
w
o
on
8
II II Ii II CORPUS CHRIST,,, (36') "'-'214
t I I EL PASO. TX (91!l) 534-9110
SAlT LAKE CIlY, UT. (SOl) 261-14S5
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
1005 - LAGUNA MADRE ~p
DATE: 03/2000 SHEET 2 OF 2
DR: DAILEY
.'
-
-,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
STATION NO.
1006
WHITECAP WWTP
. fl
I'"
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO. 1006
WHITECAP WWTP
I STATION TYPE: Wastewater Treatment Plant
i ADDRESS: 13500 Whitecap Blvd.
;
! LATITUDE: N27036.181'
l
---~---'-'--'---------'-'--'-'-----'----"'--"--'---"---t
LOCALE: West end of Whitecap Blvd.
,
LONGITUDE: W97-;;';-4~96i------__m- -...----!
........._....._______.._........_.....____._____.'.....m__....________-1
PHYSICAL DESCRIPTION:
The WWTP is accessed from a service driveway and is surrounded by a chain link security fence.
Existing RTU is located in the Control Building, The Control building is a masonry brick building
housing the RTU in one of the rooms, Plant alarms are hard-wired to the RTU but are not functional.
New RTU to be installed at lift station, Lift Station is a masonry building with MCCs, dry well, and wet
wet well. Vehicle access to the lift station is possible from two sides,
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 25 ft, - Azimuth: 3090
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1006-1 Lift Station High Level
1006-2 Main Power Failure
1006-3 Blower Failure
1006-4 Clairifier Failure
08/14/01 3:47 PM
Station Data Sheet,doc
-
-
STATION NO: 1006
WHITECAP WWTP
STATION INSTRUMENT INDEX:
OIGITAL INPUTS: 5
ANALOG INPUTS: 0
TAG NO, SERVICE DESCRIPTION STATUS
FIELO OEVICE
TIE-IN LOCATION
OIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1006 Main Power Failure EXISTING Phase Failure Monitor Existing RTU 01
Relay
JS-1006Z RTU CIrl Pwr Failure NEW 120V AC Oigitallnput RTU Panel 01
LSH-1006 Wet Well High Level EXISTING Float Switch RTU Panel 01 Intrinsically safe barrier relay
required
XS-1006A Blower Failure EXISTING Control Relay Existing RTU 01
XS-1006B Clarifier Failure EXISTING Control Relay Existing RTU 01
,-----
.
Station Instrument Index Report
08/1312001 05:43 PM
. n
I...'
....
OFFICE BLDG.
DIRECTIONAL
ANTENNA
/
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
"
~
o
'"
w
o
~
8
II II Ii II CORPUS Ct"'T< TX. (J6'1 "'-'28'
It I I [L PASO. TX (91S) ~-g110
SALT LAK[ CITY, Uf. (fI01) 211-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T,S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
1 006 - WHITECAP WWTP
DATE: 03/2000 SHEET 1 OF 2
DR: DAILEY
LAB ROOM
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
"
~
'"
o
:>
~
o
'"
o
o
1==11i11
CITY OF CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
1006 - WHITECAP WWTP
DATE: 03/2000 SHEET 2 OF 2
CORPuS CHRlSn. lX. (361) 992-2284
El PASO, 'I (915) 534-9110
SAlT lAKE CITY, Uf. (SOl) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
.
II
111
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1007
LAGUNA SHORES
LIFT STATION
I n 11'
11T
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO.1 007
LAGUNA SHORES
-
,
I STATION TYPE: Lift Station: Wet well, (4) submersible pumps
I ADDRESS: 2902 Laguna Shores Road I LOCAL~:.._~~_uth_~M~~~IIY St;~~;~~--
! SUBDIVISION: Laguna Shores Treatment Plant I WASTEWATER PLANT: Laguna Madre
j i _n__..._._._....__.__________________..n__
i LATITUDE: N27038,068' i LONGITUDE: W97017.385'
i
-
I PUMPS: (4) 50HP
I
i INFLUENT PIPE(S): 18" CIP
L. ___
PHYSICAL DESCRIPTION:
i~~~~~.~_~O:TAG~: 48~~~PH,_~~.
I FORCE MAIN: 10" CIP
.---..j
The lift station is a masonry brick building housing the pumps and electrical equipment The station is
accessed from a service driveway and is surrounded by a chain link security fence, Lift pumps are
located in the wet well and the top of the structure is flush with grade. Vehicle access to the station is
possible from two sides.
Electrical service to the lift station is routed overhead from a pole mounted transformers, The electric
meter is mounted on service pole and main service disconnect is located in building interior. Control
equipment consists of an MCC wi starters, Pump Control Panel, RTU panel, and alarm relays, All
enclosures are mounted on the masonry wall. All control devices, except level control relays and
pump sequencing controller are located in the MCC, Conduits are rigid or flexible PVC, Enclosures
and conduits are in good condition,
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system,
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3080
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1007-1 High Level
1007-2 Main Power Failure
1007-3 Motor #1 & #2 Failure
1007-4 Motor #3 & #4 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1007
LAGUNA SHORES
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 13
ANALOG INPUTS: 2
TAG NO, SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
FT-1007A Effluent Flow EXISTING Ultrasonic Flow Flow Chart AI
Transmitter Recorder
FT-1007B Effluent Flow EXISTING Ultrasonic Flow Flow Chart AI
Transmitter Recorder
JS-1007X Main Power Failure EXISTING Phase Failure Monitor MCC Aux, DI
Relay Compartment
JS-100lY Pump Ctrl Pwr Failure NEW Control Relay MCC Aux. DI
Compartment
JS-1007l RTU CIrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1007A 151 Pump Start EXISTING Float Switch Pump Conlrol DI Intrinsically safe barrier relay
Panel required
LS-1007B 2nd Pump Start EXISTING Float Switch Pump Conlrol DI Intrinsically safe barrier relay
Panel required
LS-1007C 3rd Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LS-1007D 4th Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LSH.1007 Wet Well High Level EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LSL-1007 Wet Well Low level EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
XS-1007A Pump #1 Run Status NEW Motor Starter N.O. Aux MCC Motor DI
Contact Starter
XS-1007B Pump #2 Run Status NEW Motor Starter N.D. Aux MCC Motor DI --
Contact Starter
XS-1007C Pump #3 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
XS-1007D Pump #4 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
YS-1007A Pump #1 Overtoad DEMO Control Relay MCC Motor
Starter
YS-1007B Pump #2 Overload DEMO Control Relay MCC Molor
Starter
YS-1007C Pump #3 Overtoad DEMO Control Relay MCC Motor
Starter
YS-1007D Pump #4 Overload DEMO Control Relay MCC Motor
Starter
---~
Station Instrument Index Report
08113/200105:43 PM
- ...
-
GENERATOR
BLDG.
ELECTRIC
SERVICE
POLE
ELECTRICAL
BLDG.
-
DIRECTIONAL
ANTENNA
WET WELL
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
o
"
w
o
~
o
o
11111i II CORPUS CHIOSTl. TX. ("') 99'-2284
II I n PASO, lX (915) ~-gI10
SAlT lAKE CITY, lIT. (eol) 261-14S5
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.; 1075
SCALE; N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1007 - LAGUNA SHORES
DR; DAILEY DATE; 03/2000 SHEET 1 OF 3
.
I
f1
RTU
PANEL
PUMP
CONTROL
PANEL
I
l
i
L
L
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
L
L
L
C)
'"
"
N
o
:E
w
"
~
"
"
I' II Ii II CORPUS CHAIS1l. 1lt {Jill 992-"84
t I I n PASO, TX (!l15) ~-!l110
ENGINEERING CQRPORATKlN SAlT LAKE CITY, lIT. (1lO1) 261-14SS
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1007 - LAGUNA SHORES
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
L
~
. r
I II
'liT
-
-
-
-
-
-
"
;0
o
..;
o
"
w
o
~
o
o
1=111i11
ENGINEERING CORPORATION
JOB NO.: 1075
1, TRACE OUT LEVEL CONTROLS AND ROUTE TO NEW
RTU.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1007 - LAGUNA SHORES
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI. lX. (361) 992-2284
El PASO, lX (915) 5.34-9110
SAlT lAKE CITY, UT. (801) 261-1455
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
-
-
-
STATION NO.
1008
NORTH BEACH, C
LIFT STATION
~" _ '" l'W' . . Of....'.' ,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 008
NORTH BEACH, C
,
! STATION TYPE: Lift Station: Wet well, (3) submersible pumps
f-- ----------.---~------------.--...-.-.
I ADDRESS: 3818 Surfside Blvd,
i
[SUBDIVISION:____
i LATITUDE: N27049,512'
i PUMPS: (3) 10HP
I
lINF~UENT PIPE(S):
PHYSICAL DESCRIPTION:
; LOCALE: East of Surfside
.-.------~--i
,
i WASTEWATER PLANT: Broadway
,
i LONGITUDE: W97023.145'....]
!~R~!~~Vo~i~GE:---~~O~~~~~:_~~~..~W.___i
i FORCE MAIN: 6" PVC
I
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from all sides,
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, an un-used manual transfer switch, RTU panel, and alarm relay panel. All enclosures
are mounted against the masonry wall on metal strut support brackets. All control devices, including
pump motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC.
Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system,
ANTENNA SUPPORT:
Pole - Round Alum, Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1990
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1008-1 High Level
1008-2 Main Power Failure
1008-3 Motor #1 Failure
1008-4 Motor #2 & #3 Failure
08/13/01 5:12 PM
Station Data Sheet. doc
.
I
111
STATION NO: 1008
NORTH BEACH, C
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 11
ANALOG INPUTS: 0
TAG NO, SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-100BX Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-100BY Pump Ctrl Pwr Failure NEW Control Relay (24 V AC RTU Panel DI
coil)
JS-100BZ RTU Ctrl Pwr Failure NEW PLC Digital Input RTU Panel 01
LS.100BA 1 st Pump Start EXISTING Float Switch Pump Control 01 Intrinsically safe barrier relay
Panel required
LS-100BB 2nd Pump Start EXISTiNG Float Switch Pump Control 01 Intrinsically safe barrier relay
Panel required
LS-100BC 3rd Pump Start EXISTING Float Switch Pump Control 01 Intrinsically safe barrier relay
Panel required
-
LSH-100B Wet Well High Level EXISTING Float Switch Pump Control 01 Intrinsically safe barrier relay
Panel required
LSL-100B Wet Well Low Level EXISTING Float Switch Pump Control 01 Intrinsically safe barrier relay
Panel required
XS-100BA Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-100BB Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-100BC Pump #3 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-100BA Pump #1 Overtoad DEMO Control Relay Pump Control
Panel
YS-100BB Pump #2 Overload DEMO Control Relay Pump Control
Panel
YS-100BC Pump #3 Overload DEMO Control Relay Pump Control
Panel
Station Instrument Index Report
08/13/200105:43 PM
I r
11
, --.,
TIT
-
SURFSIDE
PARK
SANITARY
SEWER
MANHOLE
ACCESS ROAD
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
"l
;:;
"
w
o
on
8
11111i II CORPUS CHRIST'. 11< (36') 992-2284
II I n PASO. lX (91~) 534-il10
SALT lAKE CITY, lIT. (801) 261-'4~
ENGINEERING CORPORATION
CITY or CORPUS CHRISTl
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1008 - NORTH BEACH STA. "C"
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.---' .
I
11
VENT
ALARM
PUMP CONTROL
PANEL
DIRECTIONAL
ANTENNA
RTU
PANEL
MANUAL
TRANSFER
SWITCH
I
L
L
L
L
L
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING, REMOVE RTU PANEL AND
\2; ASSOCIATED UNISTRUT SUPPORTS.
;-:;\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3..; ASSOCIATED UNISTRUT SUPPORTS.
r-:\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
~
oi
o
::E
~
o
'"
8
L
I' II Ii II CORPUS CHRISTl, TX. ('''199'-''84
El PASO, TX (gl~) !l34-9110
II I SALT lAKE CRY. UT. (SOl) 261-14S!
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N,T.S,
MICROWAVE COMMUNlCAll0N SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1008 - NORTH BEACH STA. "C"
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
1
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
..;
o
'"
~
o
'"
8
II II Ii II CORPUS <HOST', IX. (361) 99'-'28'
II I EL PASO. tx (gIS) 534-9110
SALT LAKE CITY. UT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N.T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1008 - NORTH BEACH STA. "c"
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
.
I
"1"1
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
-
-
-
STATION NO.
1009
-
NORTH BEACH, D
LIFT STATION
. . I 'I 1'- ,
n
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 009
NORTH BEACH, D
-
i STATION TYPE: Lift Station: Wet well, (2) submersible pumps
i
I ADDRESS: 4320 Timon Blvd.
I
rSUBDIVISION:
I LATITUDE: N27049,790'
[PUMPS: (2) 10HP
~!,LUENT PIPE(S):
PHYSICAL DESCRIPTION:
LOCALE: North Beach L.S, #D
....____._"__."___"_________..__..._______.....m__n__......--.....--.------1
!
;
------....--.-----.----------.------.-------.---.--.----"--'.'-j
I WASTEW~T_~.~~_~~T: Bro~_d.v.'~~_~________.J
! LONGITUDE: W97023.045' !
i..______________._..n___.__n___________...._._.______________J
, ,
I SERVICE VOLTAGE: 240/120V, 3PH, 4W i
: .----------------.---.--------.-.---.--------------1
I FORCE MAIN: 6" PVC I
I ___.____.__.________________________.___________.J
-
-
-
The lift station is an open air facility consistin9 of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lift station from an overhead service pole, The electric
meter and service disconnect are located on the service pole, Control equipment consists of a Pump
Control Panel, manual transfer switch, RTU panel, and relay interface panel. All enclosures are
mounted against the masonry wall on metal strut support brackets. All control devices, including pump
motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures
and conduits are in good condition.
Pumps are controlled directly with displacer type float switches interfaced through control relays and
pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio system,
ANTENNA SUPPORT:
Pole - Round Alum, Tapered (New)
Antenna Mounting Elevation: 20 ft, - Azimuth: 1990
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1009-1 High Level
1009-2 Main Power Failure
1009-3 Motor #1 Failure
1009-4 Motor #2 Failure
1009-5 Motor Control Power Failure
1009-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
.
ill
1"1
STATION NO: 1009
NORTH BEACH, D
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO, SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
JS-1009A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-1009B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1009X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1009Y Pump Ctrl Pwr Failure NEW Conlrol Relay (24 V AC Pump Control DI
coil) Panel
JS.1009Z RTU CIrI Pwr Failure NEW 120V AC Di9itallnput RTU Panel DI
LS-1009A 151 Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1009B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1009 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1009 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1009A Pump #1 Run Status NEW Motor Starter N,O, Aux Pump Control DI
Contact Panel
XS-l009B Pump #2 Run Status NEW Motor Starter N.C. Aux Pump Control DI
Contact Panel
YS-1009A Pump #1 Overtoad DEMO Control Relay Pump Control
Panel
YS-1009B Pump #2 Over1oad DEMO Control Relay Pump Control
Panel
-
Station Instrument Index Report
08/13/2001 05:43 PM
~
DIRECTIONAL
ANTENNA
~
SURFSIDE
BLVD.
~
~
TIMON ST.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
j;1
q
o
"
w
c
'"
o
o
I. II Ii II CORPUS CHRISIl, 1l<. (361) 992-228'
II I EL PASO. 11 (gl~) ~-9110
SAlT lAKE CITY. UT. (801) 2&1-1455
ENGINEERING CORPORATION
CITY OF CORPuS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1009 - NORTH BEACH STA. "0"
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.
I
,.,
PUMP CONTROL
PANEL
TRANSFER
I
L
L
L
WET WELL L
VENT
BLOWER L
L
L
L
1
1
RTU
PANEL
VALVE BOX
ACCESS
ALARM
RELAY
PANEL
l
1
l
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2.; ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS,
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING,
co
,.
Q
N
Q
2
w
Q
0>
o
o
1
It II Ii II CORPUS CHRIST,. TlL (361) 99'-"84
El PASO. Tx (i15) 534-9110
II I SAlT lAKE CITY, Uf. (801) 261-'455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
1
1
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1009 - NORTH BEACH STA. "D"
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
-
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY,
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
<:J
~
ri
o
"
~
c
'"
c
c
I, II Ii II CORPUS CHRISII," (36') 992-228'
II I tl PASO, TIC (915) 534-9110
SALT LAKE CItY, UT. (801) 261-14SS
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N,T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1009 - NORTH BEACH STA. "D"
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
I
II
111
Wastewater Department
~ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
~
-
~
STATION NO.
1010
-
ROOD FIELD
LIFT STATION
- p
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO. 1010
ROOD FIELD
~
[ STATION TYPE: Lift Station: Wet well, (2) submersible pumps ,
, ,
, ,
, . .._______.__._,_.__.__..,.__._,..,.__.______________~___._n___...._.___n_.__n__.__.___,
! ADDRESS: Rodd Field Industrial Park ! LOC~~::__E~~~~_~~.~~~~.g~ BiII.Witt ~~_~~_________J
I SUBDIVISION: Bill Witt Park / Old Airfield Hangar I.~ASTE~A!ER ~LA~!~_OSO _________________..1
I LATITUDE: N27038,901' I~GITUDE: V\JB!_~2.468~__________.___.___..__1
i PUMPS: (2) 3HP -I'_~~~~~_~?L~~~::.~~~.':: 3PH~!W___._____j
! INFLUENT PIPE(S): ~_~~.~-=_~~I_~:_.___.______________________J
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps_ The
wet well is topped with a cast-in-place concrete cap. The station is remotely located with no service
driveway or security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed from an overhead service pole. The electric meter and service disconnect
are located on the service pole. Control equipment consists of a Pump Control Panel, RTU panel, and
alarm relay panel, All enclosures are on service pole, All control devices, including pump motor
starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC, Enclosures and
conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system,
ANTENNA SUPPORT:
Pole - Round Alum, Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3310
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1010-1 High Level
1010-2 Main Power Failure
1010-3 Motor #1 Failure
1010-4 Motor #2 Failure
1010-5 Motor Control Power Failure
1010-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- ~
STATION NO: 1010
RODD FIELD
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 1
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
FT-1010 Effluent flow EXISTING Flow Transmitter Flow Transmitter AI --
JS-1010X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-1010Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coli) Panel
JS-1010Z RTU CtrI Pwr Failure NEW 120VAC Dig/tal Input RTU Panel 01
LS.1010A 15t Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-1010B 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-1010 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-1010 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-1010A Pump #1 Run Status NEW Motor Starter N,O, Aux Pump Control 01
Contact Panel
XS-1010B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-1010A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1010B Pump #2 Overload DEMO Control Relay Pump Control
Panel
Station Instrument Index Report
08/1312001 05:43 PM
-
DIRECTIONAL
ANTENNA
ELECTRIC SERVICE
POLE
-
BILL WITT
PARK
MANHOLE
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
<>
'"
q
o
'"
w
a
<>
(;
II II Ii II COOI'US CHRISTl, 1X. (JO') ...--
II I EL PASO. lX (915) 5J4-lntO
SALT lAKE cm'. Uf. (101) 281-14M
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTtWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUTlON PHOTOGRAPH
LIFT STA. 1010 - ROOD FIELD
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
,
..
11
11
DIRECTIONAL
ANTENNA
WET WELL
ACCESS
ELECTRIC
SERVICE
POLE
RTU
PANEL
TRANSFORMER
ALARM
RELAY
PANEL
PUMP CONTROL
PANEL
VALVE BOX
ACCESS W/
FLOW
SENSOR
FLOW
METER
"
~
...
o
'"
w
o
o
o
10 DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
~ ASSOCIATED UNISTRUT SUPPORTS.
;-:;\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
~ ASSOCIATED UNISTRUT SUPPORTS,
f3\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\::...J ENCLOSURE RATING.
o INSTALL NEW CABLE FROM FLOW METER TO NEW RTU.
L
I
,
L
l
I
L
L
j
It II Ii II CORPUS CHRISTI, R (36') 992-"84
II I n PASO, IX (915) 534-9110
SAlT l.Al([ CITY, UT. (801) 261-'''55
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1010 - ROOD FIELD
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S,
DR: DAILEY
"
FLOAT SWITCH
TERMINAL STRIP
~
~
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
..;
o
"
w
o
o
"
I' II Ii II CORP\IS CH""", lX, (361) 992-2'"
EL PASO. TX (915) 5.)4-51110
II I SAlT LAKE CITY, UT. (801) 261-14~
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N,T,S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1010 - ROOD FIELD
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
-
Wastewater Department
Microwave Communication System
....
City of Corpus Christi
Project No, 7100
~
....
.-
....
-
STATION NO.
1011
....
NORTH BEACH, B
LIFT STATION
- I ~ I 11 1 n,
~,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1011
NORTH BEACH, B
~
! STATION TYPE: Lift Station: Wet well, (3) submersible pumps i
, ________.____.__._..._____________._1
f ADDRESS: 3002 Timon Blvd, ! LOCALE: E, Surfside and Coastal i
, .. ..--.-...-...--..--.----.---.----__..._1
! WASTEWATER PLANT: Broadway !
._~,._.__._.___,.._._.___.,_.___.__._.___.__________~_~~___._"._.,..,__."._ .............__._..__..__ n.,
_____~-~~~?1.~~-~~:..~=!~~=.4~~------------ .........___.j
i SERVICE VOLTAGE: 480V, 3PH, 3W !
! .-.--.---.- .------.....-....-..-.-.-.--,
I FORCE_MAIN.'..~~ PVC ____________________J
~
1 SUBDIVISION:
.....
,
,
,.. ------.-
I LATITUDE: N27049.166'
r
i PUMPS: (3) 30HP
~
! INFLUENT PIPE(S): 6",18"
~
PHYSICAL DESCRIPTION:
~
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street with a service driveway. Vehicle access to the
station is possible from three sides,
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, an un-used manual transfer switch, RTU panel, and alarm relay panel. All enclosures
are mounted against the masonry wall on metal strut support brackets, All control devices, including
pump motor starters, are located in the Pump Control Panel. Conduits are rigid or ftexible PVC.
Enclosures and conduits are in good condition,
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 25 ft, - Azimuth: 198"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1011-1 High Level
1011-2 Main Power Failure
1011-3 Motor #1 Failure
1011-4 Motor #2 & #3 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
. r
II
1
TIr
STATION NO: 1011
NORTH BEACH, B
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 11
ANALOG INPUTS: 1
TAG NO, SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
FT-1011 Effluent Flow EXISTING Flow Transmitter Flow Transmitter AI
JS-1011X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1011Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1011Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1011A 1st Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS.1011B 2nd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-l011C 3rd Pump Start EXISTING Float Switch New Junction Box DI l~~trinsica"y safe barrier relay
required
LSH-l011 Wet Well High Level EXISTiNG Float Switch New Junction Box DI I~~trinsica"y safe barrier relay
required
LSL-l011 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1011A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-l011B Pump #2 Run Status NEW Motor Starter N,O, Aux Pump Control DI
Contact Panel
XS-1011C Pump #3 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS.1011A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1011B Pump #2 Overload DEMO Control Relay Pump Control
Panel
YS-1011C Pump #3 Overload DEMO Control Relay Pump Control
Panel
~-
Station Instrument Index Report
08/13/200105:43 PM
.
II
1"1
.-
DIRECTIONAL
ANTENNA
ELECTRIC
SERVICE
POLE
~
~
,...
CHEMICAL
INJECTION
PUMP
ENCLOSURE
,...
SERVICE
DISC,
UTILITY CO.
METER
-
G REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
~
o
:>
w
"
"
.-
I' II Ii II CORPUS OtRlSl1, TX. (361) 99'-'28'
II I El PASO. TX (91S) 534-9110
SALT LAKE CllY, uT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N,T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1011 - NORTH BEACH STA. "B"
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
I
11'
111
DIRECTIONAL
ANTENNA
ALARM RELAY
PANEL
PUMP CONTROL
PANEL
RTU
PANEL
MANUAL
TRANSFER
SWITCH
VALVE
BOX
ACCESS
5KVA TRANSFORMER AND
120/240V PANEL ENCL
~
L
,
.
L
L
L
O DISCONNECT POWER, ANTENNA AND ALARM WIRING, REMOVE RTU PANEL AND
1 ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING,
"'
.,
o
N
o
"
w
o
;;
L
I' II Ii II CORPUS CHRIST< lX. (J61) 99'-"84
II I El PASO, TX (915) 534-9t10
ENGINEERING CORPORATION SAlT l.AI([ CITY, UT. (801) 261-1455
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N,T.8.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1011 - NORTH BEACH STA. "B"
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
~
~
,-
~
-
~
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY,
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES,
~
..;
o
"
w
o
o
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1011 - NORTH BEACH STA. "B"
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTl. TX. (361) 992-2284
[L PASO, TX (1115) 5.34-9110
SALT lAKE CRY, uT. (801) 26t-14~
ENGINEERING CORPORATION
Wastewater Department
,- Microwave Communication System
City of Corpus Christi
Project No, 7100
....
....
....
-
....
STATION NO.
1012
....
NORTH BEACH, E
LIFT STATION
c
- ... I !I
Tl
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO. 1012
NORTH BEACH, E
~
[STATION TYPE: Lift Station: Wet well, (2) submersible p~~~.
I ADDRESS: 702 Enchanted Harbor i LOCALE: Enchan-t-;;d.H~~b~and-C-~~~-;~;~BIVd.---l
i -----...-....-.-..- ...................--.--
i SUBDIVISION: Porto Bello
L-
I WASTEWATER PLANT: Broadway
I ---.--.~--~---__.__._..__..,._______".____._..,..____._______ _ ......n....._n.m............._
I LONGITUDE: W97023,049' ;
I SERVICE-YO-LT AGE~---240V'-1PH-:3w-------.-.--l
I .--.--~-.--...-------.-..-.----.--..---1
, FORCE MAIN: 4" PVC i
, .....-.----___._._......__._..___........._.___._.........__....._.J
~
I LATITUDE: N27050.065'
~
,.
I PUMPS: (2) 2,5HP
i
I INFLUENT PIPE(S): 8" VCP
~
PHYSICAL DESCRIPTION:
-
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap that is flush with grade with a decorative masonry
wall on one side. The station is surrounded by a wooden security fence. Vehicle access around the
wet well structure is limited.
r
Electrical power is obtained from an underground electrical service with a phase adder panel. Control
equipment consists of a Pump Control Panel, RTU panel, and alarm relay panel. All enclosures
Including electric meter and service disconnect, are mounted on the masonry wall. All control devices,
including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible
PVC, Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft, - Azimuth: 1990
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1012-1 High Level
1012-2 Main Power Failure
1012-3 Motor #1 Failure
1012-4 Motor #2 Failure
1012-5 Motor #1 Failure
1012-6 Motor #2 Failure
1012-7 Control Power Failure
08113/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1012
NORTH BEACH, E
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 7
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
JS-1012A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-1012B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1012X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
LS-1012A 15t Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-1012B 2nd Pump Start EXISTING Float Switch New Junction Box 01 1~~trinslcallY safe barrier relay
required
LSH-1012 Wet Well High Level EXISTING Float Switch New Junction Box 01 1~~tlinsicaIlY safe barrier relay
required
LSL-,012 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-1012A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-1012B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-1012A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-'012B Pump #2 Overload DEMO Control Relay Pump Control
Panel
- --
Station Instrument Index Report
08/1312001 05:43 PM
. -
....
LIFT STATION
FENCE
DIRECTIONAL
ANTENNA
....
-
....
....
ENCHANTED
HARBOR
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
,.
q
o
:>
w
o
N
(3
II II Ii II CORPUS CHRISTI. TX. (361) "2-22"
II I El PASO. TX (1115) 534-9110
SAlT I.AK[ CllY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N.T,S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1012 - NORTH BEACH STA. "E"
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
. -
,
r
PUMP CONTROL
PANEL
WET WELL
ACCESS
PHASE
ADDER
SERVICE
DISC.
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.J ASSOCIATED UNISTRUT SUPPORTS,
;-:;\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\J ASSOCIATED UNISTRUT SUPPORTS.
f3\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
~ ENCLOSURE RATING,
~
N
o
'"
~
o
N
o
L
11111i II CORPUS CHRIST' TX. (361) 99'-""
II I n PASO. TX (91~) 534-91;0
ENGINEERING CORPORATION SALT LAKE CITY, UT. (801) 261-1455
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
l
JOB NO.: 1075
SCALE: N.T,S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1012 - NORTH BEACH STA. "E"
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
_ r
-
, -..,
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
.3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
..;
o
'"
~
o
N
o
II II Ii II CORI'VS CItRlSTI, TL (J61) 99'-"84
El PASO. TX (915) 534-9110
It I I SALT LAKE CITY, lIT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T,S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1012 - NORTH BEACH STA. "E"
DR: OAILEY OATE: 0.3/2000 SHEET.3 OF.3
I
~I
'1"1
.-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
STATION NO.
1013
PEOPLES ST. T -HEAD
LIFT STATION
... . PI." 1'-
-. -'.'-"
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO. 1013
PEOPLES ST. T-HEAD
ADDRESS: 600 N, Shoreline Blvd,
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
I
! LOCALE: East ofShorelineBTvd~at PeoplessC'f=-l
i Head .
----t----.--------~--."..-.--..-..---.--------.---.--.-.-..--_________m...........__________j
iWA~TEIJII~~~_~~~~~~:__~~~~~v.:~!__
i LONGITUDE: W97023.312'
,
.....--........---.]
,
!
SUBDIVISION: "T" Head
LATITUDE: N27047.787'
i SERVICE VOLTAGE: 208Y/120V, 3PH, 4W I
IFO-~~~~~~I~~_6:-CI~-~-:::_=-~~~:::__-::::=j
-
PUMPS: (2) 2HP
INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from the street and is not surrounded by a chain link security fence. Lift pumps are located
in the dry well and the top of the structure is flush with grade. Vehicle access to the station is possible
from two sides,
Electrical service to the lift station is routed underground from a pad mounted transformer. The main
service disconnect is located in building interior. Control equipment consists of individual starters,
Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on the masonry
wall. All control devices and pump sequencing controller are located in the pump control panel.
Conduits are rigid or flexible PVC, Enclosures and conduits are in fair condition,
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 25 ft. - Azimuth: 2050
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1013-1 Drywell High Level
1013-2 Main Power Failure
1013-3 Motor #1 Failure
1013-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
1 r
II
" .......
TI
1'.'--'--'
STATION NO: 1013
PEOPLES ST. T-HEAD
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN lOCATION
DIGITAL OUTPUTS;
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
JS-1013X Main Power Failure NEW Phase Failure Monitor Electrical Service DI
Relay Disc.
JS-1013Y Pump Ctrl Pwr Failure NEW Control Relay (120 VAC Pump Control DI
coil) Panel
JS-1013Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
lS-1013A 1 st Pump Start EXISTiNG Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
lS-1013B 2nd Pump Starl EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
lSH-1013 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
lSHH-1013 Dry Well High level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
lSl-1013 Wet Well Low Level EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
XS-1013A Pump #1 Run Status NEW Motor Starter N,O, Aux Motor Starter DI
Contact
XS-1013B Pump #2 Run Status NEW Motor Starter N,O, Aux Motor Starter DI
Contact
YS-1013A Pump #1 Overload DEMO Control Relay Motor Starter
YS-1013B Pump #2 Overload DEMO Control Relay Motor Starter
--
Station Instrument Index Report
08/13/200105:43 PM
I
.
II
ITI
II II Ii II CORPUS "'lOST' T< (361) 99'-2284
n PASO. TX (915) S34-\1110
II I SAlT I.AKf CITY, Uf. (SOl) 261-1455
ENGINEERING CORPORATION
-
-
PUMP
ROOM
"
,.
'"
o
"
w
"
'"
;;
JOB NO,: 1075
-
DIRECTIONAL
ANTENNA
(0 REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N,T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1013 - PEOPLES ST. T -HEAD
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
-
LIGHTING
PANEL
DOOR
o DISCONNECT POWER, ANTENNA AND ALARM WIRING, REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
"
~
N
o
"
~
o
'"
;;
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1013 - PEOPLES ST. T-HEAD
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
CORf'VS 0fRISTI. Tit (361) 992-2284
n PASO, 1X (915) 534-9110
SAlT lAKE CITY, Uf. (eol) 261-145!1
ENGINEERING CORPORATION
.
I.
~
.....
~
~
.....
......
.....
1, TRACE OUT MECHANICAL LEVEL SWITCH CONTROLS,
2, INSTALL CONDUIT AND CONDUCTORS TO NEW RTU.
'"
~
o
..;
o
"
w
o
....
;;
1==11i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 1100
JOB NO,: 1075
SCALE: N,T,S,
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1013 - PEOPLES ST. T-HEAD
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI. TX. (361) 992-2284
El PASO, IX (915) ~-9110
SAlT lAKE CITY, UT. (801) 261-14S5
ENCINEERINC CORPORATION
- ...
-
,-
~
~
~
.....
.....
"----n
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO.
1014
LAWRENCE ST. T -HEAD
LIFT STATION
~ -, '
, ' r '
. I
1I
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No, 7100
STATION NO. 1014
LAWRENCE ST. T-HEAD
-
------
i STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
L-____ _ ___..__._._..___._______________._._..._.___.__________.._._.._._._._.__.__ . ,
I ADDRESS: 400 N. Shoreline Blvd. : LOCALE: TEaHst odf Shoreline Blvd, at Lawre-ricesT----:
i F - ea
i ---r'""--------."'----..---n-..n--.-----"_"_....n_n......'______....u....... .. .-..--..-.-.--,..------~
I SUBDIVISION: "T" Head I WAS!=~~~:.R P:~N_~:___~road\V~~_______________i
I LATITUDE: N27047,563' I LONGITUDE: W97023,303' I
I : ___._.,_,.___.___~_______._.__....,___.~___.___.....______________~
i PUMPS: (2) 2HP : SERVICE VOLTAGE: 20BY/120V, 3PH, 4W I
flNFLUENT PIPE(S): i FORCE MAIN: 6;,-CiP-------------------------j
l___ ...._.__._~_________._____..___._.____.._.___._._..____._________._~
-
PHYSICAL DESCRIPTION:
-
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from the street and is not surrounded by a chain link security fence. Lift pumps are located
in the dry well and the top of the structure is flush with grade. Vehicle access to the station is possible
from two sides.
Electrical service to the lift station is routed underground from a pad mounted transformer. The main
service disconnect is located in building interior. Control equipment consists of individual starters,
Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on the masonry
wall. All control devices and pump sequencing controller are located in the pump control panel.
Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition,
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system,
ANTENNA SUPPORT:
Pole - Wood (Exist)
Antenna Mounting Elevation: 25 ft. - Azimuth: 206"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1014-1 Wetwell High Level
1014-2 Main Power Failure
1014-3 Motor #1 Failure
1014-4 Motor #2 Failure
08/13/01 5: 12 PM
Station Data Sheet.doc
-
STATION NO: 1014
LAWRENCE ST. T-HEAD
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO, SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-I014X Main Power Failure NEW Phase Failure Monitor Electrical Service DI
Relay Disc.
JS-I014Y Pump CIrl Pwr Failure NEW Control Relay (120 V AC Pump Control DI
coil) Panel
JS-1014Z RTU CIrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1014A 1st Pump Start EXiSTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1014B 2nd Pump Start EXiSTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1014 Wet Well High level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSHH-1014 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1014 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-I014A Pump #1 Run Status NEW Motor Starter N.O, Aux Motor Starter DI
Contact
XS-I014B Pump #2 Run Status NEW Motor Starter N.O, Aux Motor Starter DI
Contact
YS-I014A Pump #1 Overload DEMO Control Relay Motor Starter
YS-1014B Pump #2 Overload DEMO Control Relay Motor Starter
Station Instrument Index Report
08f1312001 05:43 PM
.
I
T7
PUMP
ROOM
DIRECTIONAL
ANTENNA
-
-
-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND All ASSOCIATED HARDWARE.
fi
~
o
"
w
o
.
o
11111i II C<IRPIJS CHOST, IX. (361) 092-"84
n PASO. TX (915) 5l4-!JI10
II I SAlT LAKE CITY, UT. (!OI) 26\-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T,S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1014 - LAWRENCE ST. T -HEAD
DR: DAilEY DATE: 03/2000 SHEET 1 OF 3
LIGHTING
PANEL
ALARM RELAY
PANEL
(0 DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
"
~
N
o
"
w
o
..
"
II II Ii II CORPUS 0tlllS1I. IX. (361) 992-2284
II I n PASO. 1X (915) 534-9110
ENGINEERING CORPORATION 5'U tAKE CllY. Uf. (801) "1-1."
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N,T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1014 - LAWRENCE ST. T-HEAD
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
-
-
1. TRACE OUT MECHANICAL LEVEL SWITCH CONTROLS.
2. INSTALL CONDUIT AND CONDUCTORS TO NEW RTU.
11
o
..;
o
"
w
o
~
;;
I' II Ii II CORPUS <HOST' 1X. (>61) 992-2'"
EL PASO. IX (gIS) 5J4-g110
II I SAlT I.AK( CllY. lJT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of' CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N,T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1014 - LAWRENCE ST. T -HEAD
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No, 7100
-
-
-
-
STATION NO.
1015
COOPER'S ALLEY L-HEAD
LIFT STATION
- _.. r ,.
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1015
COOPER'S ALLEY L-HEAD
~
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
~
PUMPS: (2) 2HP
INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
_""_"._.__n_n_._ "._______.__.__._~______ _____________"__"_.;.
I LOCALE: East of Shoreline Blvd, at Cooper's Alley I
:...-----.------. . -- ---------------1
i WASTEWATER PLANT: Broadway i
,......_.....--............__..._.___....__.._._....._.__._...._.........................-.1
I LONGITUDE: W97023.397' !
----.----.-............-..... ...__._-----~
I SERVICE VOLTAGE: 208Y/120V, 3PH, 4W i
~ -~ ---..--....--..---....---.------\
! FORCE MAIN: 6" CIP i
~
ADDRESS: 200 S, Shoreline Blvd.
SUBDIVISION: "L" Head
LATITUDE: N27047.459'
.-
.-
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from the street and is not surrounded by a chain link security fence, Lift pumps are located
in the wet well and the top of the structure is flush with grade, Vehicle access to the station is possible
from two sides.
.-
.-
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is mounted on building exterior and main service disconnect is located in building
interior. Control equipment consists of individual starters, Pump Control Panel, RTU panel, and alarm
relay panel. All enclosures are mounted on the masonry wall. All control devices and pump
sequencing controller are located in the pump control panel, Conduits are rigid or flexible PVC,
Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller, Trouble alarms are currently reported through the UHF radio
system,
~
,-
ANTENNA SUPPORT:
Pole - Round Alum, Tapered (New)
Antenna Mounting Elevation: 25 ft, - Azimuth: 2060
~
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1015-1 High Level
1015-2 Main Power Failure
1015-3 Motor #1 Failure
1015-4 Motor #2 Failure
.-
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1015
COOPER'S ALLEY L-HEAD
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
JS-1015X Main Power Failure NEW Phase Failure Monitor Electrical Service DI
Relay Disc.
JS-1015Y Pump CtrI Pwr Failure NEW Control Relay (120 VAC Pump Control DI
coli) Panel
JS-1015Z RTU CIrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1015A 1st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1015B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1015 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1015 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1015A Pump #1 Run Status NEW Motor Starter N,O. Aux Motor Starter DI
Contact
XS-1015B Pump #2 Run Status NEW Motor Starter N.D. Aux Motor Starter DI
Contact
YS-1015A Pump #1 Overload DEMO Control Relay Alarm Relay Panel
YS-1015B Pump #2 Overload DEMO Control Relay Alarm Relay Panel
Station Instrument Index Report
08/13/2001 05:43 PM
I
11
111
.-
~
JANE'S L-HEAD
SEAFOOD HOUSE
DIRECTIONAL
ANTENNA
,...
....
...
...
...
...
....
...
,...
LIFT STATION BLDG,
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE,
,...
-
<:>
"
~ 0
o
:>
~
o
~
o
It II Ii II CORPUS CHRIS" lX. (361) 992-228'
II I El PASO. TX (915) 534-9110
SALT lAKE CITY, UT. (801) 261-14~
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE; N,T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1015 - COOPER'S ALLEY L-HEAD
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
. -.
TO CONTROL
PANEL
RTU
PANEL
LIGHTING
PANELBOARD
i
"F'
ALARM RELAY
PANEL
o DISCONNECT POWER, ANTENNA AND ALARM WIRING, REMOVE RTU PANEL.
(3) DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1015 - COOPER'S ALLEY L-HEAD
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
'"
"
o
N
o
"
w
o
on
o
It II Ii II CORPUS CHRlSll, IX. (361) 992-"84
II I El PASO. TX (915) 534-9110
SALT LAK€ CITY UT. (BOI) 261-1455
ENGINEERING CORPORATION '
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO,: 1075
SCALE: N,T.S,
-
PROJECT NO. 7100
~
-
-
FLOAT SWITCHES
CONDUIT
-
-,
1. TRACE OUT AND REMOVE ALL ALARM WIRING,
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
.;
o
"
w
o
on
<3
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N,T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1015 - COOPER'S ALLEY L-HEAD
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
[L PASO. TIC (91~) ~-91l0
SAlT lAKE CITY. UT. (801) 261-1455
ENGINEERING CORPORATION
.
I
1"~
Wastewater Department
~ Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
~
-
STATION NO.
1016
MAGEE BEACH
LIFT STATION
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1016
MAGEE BEACH
-
.----,
! STATION TYPE: Lift Station: Wet well, (2) submersible pumps ;
f _.__.~~___._._____".__,__.__________.__.._._.~
i ADDRESS: 500 S. Shoreline Blvd. I LOCALE: ~as: of Shoreline Blvd, at Magee Beach I
r I.____~_~~!~~m -------..-.---~--,..,.--.---~---.-.-.-i
I SUBDIVISION: Magee Beach I WASTEWATER PLANT: Broadway
, I "
IL~TITUDE: N2J047.216' I LONGITUDE: W97023,61o.-'--'-~--'----------]
I
---..---.--------------.------..-.-..-.,..-.-.-.----~-----.l
I PUMPS: (2) 2.5HP I SERVICE VOLTAGE: 208Y/120V, 3PH, 4W i
I . _____.___.....___~._._...___._____:
I FORCE MAIN: 10" CIP ,
-
i INFLUENT PIPE(S):
l
PHYSICAL DESCRIPTION:
The lift station is a concrete building consisting of wet wellloeated near a public restroom. The station
is accessed from the street. Lift pump control panel is located in a narrow pipe chase in the men's
restroom. Vehicle access to the station is limited due the seawall structure.
Electrical service to the lift station is routed underground from a pad mounted transformer. The main
service disconnect is located in pipe chase. Control equipment consists of Pump Control Panel, RTU
panel, and alarm relay panel. All enclosures are mounted on the concrete wall, All control devices are
located in the Pump Control Panel. Conduits are rigid or flexible PVC, Enclosures and conduits are in
good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 30 ft. - Azimuth: 205"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1016-1 High Level
1016-2 Main Power Failure
1016-3 Motor #1 Failure
1016-4 Motor #2 Failure
1016-5 Motor Control Power Failure
1016-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
..
1'1
...
STATION NO: 1016
MAGEE BEACH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TVP COMMENTS
JS-1016X Main Power Failure EXISTING Phase Failure Monitor Pump Control 01
Relay Panel
JS-1016Y Pump Ctrt Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-1016Z RTU CtrI Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l016A 151 Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe banier relay
required
LS-1016B 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-1016 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-1016 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-1016A Pump #1 Run Status NEW Molor Starter N,O. Aux Pump Control DI
Contact Panel
XS-1016B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-1016A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1016B Pump #2 Overload DEMO Control Relay Pump Control
Panel
Station Instrument Index Report
08/13/200105:43 PM
n
~.
T-'
11
SEA WALL
DIRECTIONAL
ANTENNA
-
-
MAGEE
BEACH
.-
~
.~.,..
-
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE,
C)
;<
q
o
:0
w
o
'"
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO,: 1075
SCALE: N,T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1016 - MAGEE BEACH
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
CORPUS OIRISI'I, IX. (3fH) 992-2284
n PASO. TX (915) 5,J4-t110
SAlT lAKE CITY. UT. (1101) 261-14~
ENGINEERING CORPORATION
~
- ...
-
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1016 - MAGEE BEACH
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
PUMP CONTROL
PANEL
BOOSTER
TRANSFORMERS
o DISCONNECT POWER, ANTENNA AND ALARM WIRING, REMOVE RTU PANEL.
(3) DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
/3\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\::..J ENCLOSURE RATING.
()
il:
o
...
o
,.
~
o
..
o
I'll Ii II CORPuS CHRISTJ, TX. (J611 "'-"84
II n PASO. TX (915) 534-9110
SAlT I.AKf CITY. UT. (B01) 2&1-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N,T.S.
.
SERVICE
DISC.
RTU
PANEL
ALARM
RELAY
PANEL
PROJECT NO. 7100
-
FLOAT SWITCH
TERMINAL STRIP
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
~
ri
o
"
w
C
'"
;:;
-
1:11 Ii II
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1016 - MAGEE BEACH
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
[L PASO. TX (915) 534-9110
ENGINEERING CORPORATION SAlT lAKE CITY, 01. (801) 261-1455
.
II
TT
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
....
.....
....
....
STATION NO.
.-
1017
....
STUDEBAKER
LIFT STATION
~-
~ I' I ~
TIT
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1017
STUDEBAKER
.,....
....
,
! STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps :
,. -"~_.__.,."--_._--~-___._____.___".."."_.___.___.__._J
! ADDRESS: 300 Kinney Ave i LOCALE: Kinney & Chaparral (East of Water) !
~.---.-....._.--._--_.-..--....---.-------....-.-..--.--------i
i WASTEWATER PLANT: Broadway i
, ,
-,.____...__._'___,._'_'_.__"_..__~_~____..m______._..___~______.__...............__._.__._._____,
! LONGITUDE: W97023.736' !
t _ " __ ",,!
1 ___......._..._.......__.____________n.._______ ._-_.._-_._-_..__.__.__....~
! SERVICE VOLTAGE: 208Y/120V, 3PH, 4W
I ___..__._____._____.___.__._._.........________._...._._______--1
! FORCE MAIN: 8" CIP i
, ,
,_____"_"___._..___..__._.__.__________._.___._____.~_._________.___.__.___...-1
i SUBDIVISION: South End of Shoreline(City Hall)
L__.
I LATITUDE: N27047.440'
;
....
i!,UMPS: (2) 15HP
I INFLUENT PIPE(S):
....
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well and dry well structure. Lift
pumps are located in the dry well and the top of the structure is flush with grade. The station is located
adjacent to the street and does not have a service driveway or security fence. Vehicle access to the
station is possible from all sides.
Electrical service to the lift station is routed underground from the distribution system. The electric
meter and service disconnect are located on a short pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on metal strut support
brackets. All control devices, including pump motor starters, are located in the Pump Control Panel.
Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 25 ft. - Azimuth: 202"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1017-1 Wetwell High Level
1017-2 Main Power Failure
1017-3 Motor #1 Failure
1017-4 Motor #2 Failure
1017-5 Drywell High Level
1017-6 Motor Control Power Failure
1017-7 Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
I
II
11'11
STATION NO: 1017
STUDEBAKER
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS; 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1017X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1017Y Pump CIrI Pwr Failure NEW Control Relay (24 VAC Pump Control DI
coil) Panel
JS-1017Z RTU CIrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1017A 1st Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS-1017B 2nd Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LSH-1017 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSHH-1017 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1017 Wet Well Low Level EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
XS-1017A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1017B Pump #2 Run Status NEW Molar Starter N.O. Aux Pump Control DI
Contact Panel
YS-1017A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1017B Pump #2 Overload DEMO Control Relay Pump Control
Panel
Station Instrument Index Report
08113/2001 05:43 PM
_ n
,...
.
....
DIRECTIONAL
ANTENNA
.-
....
.....
CHAPARRAL
STREET WET
WELL
ACCESS
"'- DRY WELL
ACCESS
....
....
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
'"
q
o
"
w
C
~
o
11111i II ClIRP\lS 0<",,, TX. (J6ll 992-""
II I n PASO, TX (915) ~-glI0
SAlT I..AK[ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM-
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1017 - STUDEBAKER
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
L
PUMP L
CONTROL
PANEL RTU L
PANEL
UTILITY CO. L
METER
ALARM
RELAY L
PANEL
L
L
L
WETWELL
HIGH LEVEL
FLOAT SW, CONDUIT L
DRYWELL
HIGH LEVEL
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
~ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1017 - STUDEBAKER
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
11
c
N
o
"
w
C
~
C
I, II Ii II CORPUS CHRIST, T~ (361) 992-'28'
II I n PASO, TX (915) 534-9110
SAlT lAIC[ CITY, lIT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY Of' CORPUS CHRISTl
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
1
11
PROJECT NO. 7100
L
L
T1r
r-
1017
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
'"
c
.-;
o
"
w
C
~
;:;
I, II Ii II CORPUS CHlOSlI. TX. (361) "'-"84
II I [L PASO. TX (915) 534-9110
~T LAKE CITY, lIT. (801) 2fil-1-4M
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1017 - STUDEBAKER
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
~
11
I"
,
,
-
Wastewater Department
_ Microwave Communication System
City of Corpus Christ;
Project No. 7100
....
-
-
.....
-
STATION NO.
1018
-
NUECES BAY
LIFT STATION
.----.r ~. ,
~ '_. ,
!T
....
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1018
NUECES BAY
-
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: 2100 Nueces Bay Blvd. LOCALE: Nueces Bay Blvd. and Summer Street
SUBDIVISION: WASTEWATER PLANT: Broadway
LATITUDE: N27"48.522' LONGITUDE: W97025.151'
PUMPS: (2)3HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN:
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well and dry well structure. Lift
pumps are located in the dry well and the top of the structure is flush with grade. The station is located
adjacent to the street and does not have a service driveway or security fence. Vehicle access to the
station is limited due to road barrier wall on one side.
Electrical service to the lift station is routed underground from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1830
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1018-1 Wetwell High Level
1018-2 Main Power Failure
1018-3 Motor #1 Failure
1018-4 Motor #2 Failure
1018-5 Drywell High Level
1018-6 Motor Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- -
STATION NO: 1018
NUECES BAY
STATION INSTRUMENT INDEX:
OIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE OESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
OIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
- - - -------~-:-- -- --
JS-1018X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-1018Y Pump Gtrl Pwr Failure NEW Control Relay (120 V AC Pump Control 01
coil) Panel
JS-1018Z RTU etrl Pwr Failure NEW 120VAC Oigitallnput RTU Panel 01
LS-1018A 1st Pump Start FUTURE Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1018B 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-1018 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LsHH:'018 ~- ._- EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay -
Dry Well High Level
required
LSL-1018 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-1018A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
XS-1018B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
YS-1018A Pump #1 Overload OEMO Control Relay Pump Control
Panel
YS-1018B Pump #2 Overload OEMO Control Relay Pump Control
Panel
, -- ,._~ - -
Station Instrument Index Report
08/13/2001 05:43 PM
--.
.
n1
11
SERVICE
DISC.
SERVICE
~
,...
DIRECTIONAL
ANTENNA
,...
....
UTILITY CO.
METER
NUECES BAY
BLVD.
DRY WELL
ACCESS
WET WELL
ACCESS
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"'
'"
"
o
:>
w
C
m
;:;
1:111i11
CITY OF" CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1018 - NUECES BAY
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI. TX. (J61) 992-22~
[l PASO, 1X (915) 534-9110
WTl.AI<ECITY,UT. (&11)261-1455
ENGINEERING CORPORATION
..
I"
-~
J
PUMP
CONTROL
PANEL
1
1
1
1
1
1
1
1
1
RTU
PANEL
WET WELL
HIGH LEVEL
FLOAT SW.
CONDUIT
ALARM
RELAY
PANEL
DRY WELL
HIGH LEVEL
FLOAT SW.
CONDUIT
J
1
J
O DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
1 ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
r:\_ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
AND
J
J
J
J
~
c
N
o
"
w
C
'"
o
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7101
I. II Ii II CORPUS C",<SIC T. I''') 992-"84
II I [L PASO. Tl (915) 5.}4-9110
SAl.T LN<E CITY, UT. (801) 261-'''55
ENGINEERING CORPORATION
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1018 - NUECES BAY
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
-
~
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
;0
c
..;
o
"
w
a
'"
o
1:111i11
ENGINEERING CORPORATION
CITY Of' CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
COfU>US CHRISTI, TX. (J61) 992-2284
EL PASO. TIC (gIS) 534-9110
SAlTl.AI([CJTY,UT. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1018 - NUECES BAY
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
... r
rI
nr
Wastewater Department
.... Microwave Communication System
City of Corpus Christi
Project No. 7100
....
STATION NO.
1019
WOOD RIVER
LIFT STATION
",. _ ~ _ r ~ _" 'I' ,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1019
WOOD RIVER
STATION TYPE: Lift Station: Wet well, (3) submersible pumps ,
ADDRESS: 4601 Spring Creek Drive LOCALE: River Hills Country Club
SUBDIVISION: Wood River #5 WASTEWATER PLANT: Allison
LATITUDE: N27052.060' LONGITUDE: W97039.1 01'
PUMPS: (3) 88HP SERVICE VOLTAGE: 480V, 3PH, 3W i
INFLUENT PIPE(S): 16" DIP FORCE MAIN: 8"PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility with a walk-in type MCC enclosure housing the electrical
equipment. The station is accessed from a service driveway and is surrounded by a wooden security
fence. Vehicle access to the station is possible from one side.
Electrical service to the lift station is routed underground from a local pad mounted transformer. The
electric meter is located on transformer housing exterior. Control equipment consists of a Motor
Control Center (MCC), Pump Control Panel, RTU panel, and alarm relay panel. RTU panel is
mounted on interior door of MCC. Pump Control Panel and alarm relay panel are located in the MCC.
Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Wood, 45 ft, Class 5 (New)
Antenna Mounting Elevation: 40 ft. - Azimuth: 125"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1019-1 High Level
1019-2 Main Power Failure
1019-3 Motor #1 & #2 Failure
1019-4 Motor #3 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
.
II
Tl
STATION NO: 1019
WOOD RIVER
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 11
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
EXISTING Phase Failure Monitor -------
JS-1019X Main Power Failure Pump Control DI
Relay Panel
JS-1019Y Pump Ctrl Pwr Failure NEW Control Relay (120 VAC Pump Control DI
coil) Panel
JS-1019Z RTU Ctrl Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-1019A 15t Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-10198 2nd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-1019C 3rd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSH-1019 Wet Well High Level EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay --
required
LSL-1019 Wet Well Low Level EXISTING Float Switch New Junction Box Di Intrinsically safe barrier relay
required
XS-1019A Pump #1 Run Status EXISTING Motor Starter N.D. Aux Pump Control DI Soft Starter not connected
Contact Panel
XS-10198 Pump #2 Run Status EXiSTING Motor Starter N.D. Aux Pump Control DI Soft Starter not connected
Contact Panel
XS-1019C Pump #3 Run Status EXISTING Motor Starter N.D. Aux Pump Control DI Soft Starter not connected
Contact Panel
YS-1019A Pump #1 Overload DEMO Control Relay Pump Control
Panel
- DEMO-- -------,-- ----=-- .-- -------- ..--
YS-10198 Pump #2 Dver10ad Control Relay Pump Control
Panel
YS-1019C Pump #3 Over1oad DEMO Control Relay Pump Control
Panel
d_ --_.--- --
Station Instrument Index Report
08/13/200105:43 PM
.
T"
v
~
TRANSFORMER
ENCLOSURE
DIRECTIONAL
ANTENNA
MOTOR CONTROL
CENTER CABINET
~
~
G REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
<.>
"
'"
o
"
w
C
m
C
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1019 - WOOD RIVER
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, IX. (361) 992-2284
El PASO. TX (915) 5.34-8110
SAlT l.N([ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
.
I
, ........
,.~
SOFT START
MOTOR
STARTERS
(TYP 3)
(NOT USED)
PUMP CONTROL
PANEL
1
1
1
L
1
L
1
1
1
L
L
L
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2..J REPAIR MOUNTING HOLES IN CABINET.
(3) DISCONNECT ALARM WIRING AND REMOVE ALARM RELAYS FROM CUBICLE.
L
L
"
~
c
...
o
"
w
C
m
;:;
L
L
It II Ii II CORI'VS CH""". "'. (J6') 992-228'
I t I tl PASO. TX (915) ~-9110
SAlT LAKE CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1019 - WOOD RIVER
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
L
I
r
1"
....
1. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
2. INSTALL NEW CONDUCTORS FROM EXISTING PHASE FAILURE
MONITOR TO NEW RTU.
"
;0
c
..;
c
"
w
c
go
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N_T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1019 - WOOD RIVER
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI. IX. (361) 992-2284
El PASO, IX (915) 534-9110
SAtT lAKE CITY, Uf. (801) 261-1.(55
ENGINEERING CORPORATION
DR: DAILEY
I ..
11
ll'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
STATION NO.
1020
RIVER CANYON
LIFT STATION
'I ,. I II ,~ -",
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1020
RIVER CANYON
-
STATION TYPE: Lift Station: Wet well, (2) submersible pumps ,
ADDRESS: 13842 River Ridge Dr. LOCALE: North of Five Points Center
SUBDIVISION: River Canyon #2 WASTEWATER PLANT: Allison
LATITUDE: N27051.971' LONGITUDE: W97038.134'
PUMPS: (2) 20HP SERVICE VOLTAGE: 240/120V, 3PH, 4W !
INFLUENT PIPE(S): 8"VCP FORCE MAIN: 8"PVC I
....
-
PHYSICAL DESCRIPTION:
....
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from one side.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, manual transfer switch, RTU panel, soft starters, and alarm relay panel. All enclosures
are mounted against the masonry wall on metal strut support brackets. All control devices, excluding
pump motor starters, are located in the Pump Control Panel. Conduits are rigid or fiexible PVC.
Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type fioat switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Wood, 45 ft, Class 5 (New)
Antenna Mounting Elevation: 40 ft. - Azimuth: 126"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1020-1 High Level
1020-2 Main Power Failure
1020-3 Motor #1 Failure
1020-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
.
I
fl
STATION NO: 1020
RIVER CANYON
STATION INSTRUMENT INDEX:
TAG NO. SERVICE DESCRIPTION STATUS
~-
JS-1020X Main Power Failure
JS-1020Y Pump ClrI Pwr Failure
JS-102QZ RTU Gtrl Pwr Failure
LS-1020A 1st Pump Start
LS-1020B 2nd Pump Start
LSH-1020 Wet Well High Level
I - --
LSL-1020 I Wet Well Low Level
XS-1020A
XS-1020B
Pump #1 Run Status
Pump #2 Run Status
Station Instrument Index Report
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
FIELD DEVICE
TIE-IN LOCATION
NEW Phase Failure Monitor Pump Control
Relay Panel
NEW Control Relay (24 VAC Pump Control
coil) Panel
NEW 120VAC Digital Input RTU Panel
EXISTING Float Switch New Junction Box
EXISTING Float Switch New Junction Box
EXISTING Float Switch New Junction Box
EXISTING Float Switch New Junction Box
NEW
NEW
Motor Starter N.D. Aux
Contact
Motor Starter N.O. Aux
Contact
Pump Control
Panel
Pump Control
Panel
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
DI
- -
DI
DI
DI
Intrinsically safe barrier relay
required
Intrinsically safe barrier relay
required
Intrinsically safe barrier relay
required
Intrinsically safe barrier relay
required
DI
DI
DI
DI
DI
08/13/200105:43 PM
-
DIRECTIONAL
ANTENNA
ELECTRIC SERVICE
POLE
VALLEY DR. &
RIDGE DR.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
'"
"
"
"
w
"
"
N
"
II II Ii II CORPUS CHRlSTI. lX. ('51) 99'-2284
II I El PASO, TX (915) ~-9110
SALTLAK(CrrY.UT. (801)261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1020 - RIVER CANYON
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
-
-
SOFT START
MOTOR
STARTER
TRANSFER
SWITCH
1
1
1
1
1
1
1
1
1
1
ALARM
RELAY
PANEL
ANTENNA
POLE
WET WELL
ACCESS
DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
1
1
1
1
o
o
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
'-'
'"
c
N
o
"
w
c
'-'
N
C
1
1:111i11
ENGINEERING CORPORATION
CflY OF CORPUS CHRISTI
WASTEWATER DEPT.
1
PROJECT NO. 7100
L
CORPuS CHRIST'. TX. (J61) 992-2284
EL PASO. TX (915) 534-11110
SAlT LAKE CITY, uT. (801) 251-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1020 - RIVER CANYON
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
-
-
~
....
....
....
....
1. TRACE OUT AND REMOVF <&L.EXJSIJ,NG ALAR~__V'lI_f3.ING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
o
~
C
,.-;
o
~
w
C
o
N
o
1:111i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PRQUECT NO. 7100
CORPUS CHRISTl. TX. (J61) 992-2284
(l PASO, TX (915) 534~9110
SAlT lAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1020 - RIVER CANYON
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
.
I
fT
Wastewater Department
.- Microwave Communication System
City of Corpus Christi
Project No. 7100
-
....
....
STATION NO.
1021
UP RIVER ROAD
LIFT STATION
--, " : I r""
Ii
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 021
UP RIVER ROAD
-
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: 12451 Up River Road LOCALE: North of Magee Lane
SUBDIVISION: Calallen Area WASTEWATER PLANT: Allison
LATITUDE: N27051.702' LONGITUDE: W97036.499'
PUMPS: (2) 25HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN:
....
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station
has a service driveway. Lift pumps are located in the dry well and the top of the structure is located 3
feet above grade. Vehicle access to the station is possible from all sides.
Electrical service to the lift station is routed from an overhead service pole. The electric meter and
service disconnect are located on the building exterior. Control equipment consists of a Switchboard
with starters, Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on
the masonry wall. All control devices, except level control relays and pump sequencing controller. are
located in the Switchboard. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1290
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1021-1 Wetwell High Level
1021-2 Main Power Failure
1021-3 Motor #1 & #2 Failure
1021-4 Drywell High Level
08/13/01 5:12 PM
Station Data Sheet.doc
- ,.
-
STATION NO: 1021
UP RIVER ROAD
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
JS.1021X Main Power Failure NEW Phase Failure Monitor Switchboard DI I
Relay
JS-1021Y Pump Ctrl Pwr Failure NEW Control Relay (120 VAC Pump Control DI
coil) Panel
JS-1021Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1021A 15t Pump Start EXISTING Mechanical Float Switch Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS-1021B 2nd Pump Start EXISTING Mechanical Float Switch Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LSH-1021 Wet Well High Level EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
----.._."
LSHH-1021 Dry Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-1021 Wet Well Low Level EXISTING Mechanical Sensor Sensor J-Box 01 Provide intrinsically safe barrier
relay for future float switch
XS-1021A Pump #1 Run Status NEW Motor Starter N.O. Aux Switchboard DI
Contact
XS-1021B Pump #2 Run Status NEW Motor Starter N.D. Aux Switchboard DI
Contact
YS-1021A Pump #1 Overload DEMO Control Relay Switchboard i
YS-1021B Pump #2 Overload DEMO Control Relay Switchboard
. _._-~
StaUon Instrument Index Report
OB/13f2001 05:43 PM
-
-
~
....
PUMP BLDG
UP RIVER RD.
....
-
....
....
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
~
o
"
w
C
N
C
1:11 Ii II
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTL, lx. (361) 992-2284
n PASO, tx (915) 534-9110
SALT lJd([ CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1021 -UP RIVER ROAD
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
- ..
-
1
1
1
1
MANUAL 1
TRANSFER
SWITCH
1
1
1
i
1
i
1
PANEL.
L
L
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1021 -up RIVER ROAD
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
RTU
PANEL
LIGHTING
PANEL
ALARM
RELAY
PANEL
HIGH LEVEL
FLOAT SWITCH
CABLE (DRY /
WET WELL)
~
c
'"
o
"
w
C
N
C
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
(2) INSTALL NEW PHASE FAILURE MONITOR RELAY.
o ROUTE EXISTING FLOAT SWITCHES TO RTU.
II-Iii II COAP\JS 0"."". lX_ (361) 992-228'
It I I [l PASO, lx (915) S34-9ltO
!W.TlAKE CiTY,UT. (801)261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
-
-
L
PROJECT NO. 7100
L
L
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1021 -UP RIVER ROAD
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
....
~
....
....
.-
....
....
1. TRACE OUT MECHANICAL LEVEL SWITCHES AND
ROUTE STATUS TO RTU.
"
'"
c
ri
o
"
w
C
N
o
1:11 Ii II
CITY OF CORPUS CHRISTI
WASTEwATER DEPT.
CORPuS CHRISTI, lX. (J6I) 992-2284
[L PASO, TX (915) 5,}4-9110
SALT LAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
SCALE: N.T.S.
I ..
11
MECHANICAL
LEVEL SENSOR
PUMP CONTROL
PANEL
PROJECT NO. 7100
m
~
Wastewater Department
..... Microwave Communication System
City of Corpus Christi
Project No. 7100
.....
....
....
.....
....
STATION NO.
1022
.....
.....
....
NUECES ACRES
LIFT STATION
~ I' I 11 r .-.
m
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1022
NUECES ACRES
....
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
.....
ADDRESS: 11501 Haven Drive LOCALE: South of Starlite Lane
SUBDIVISION: Nueces Acres WASTEWATER PLANT: Allison
LATITUDE: N27049.631, LONGITUDE: W97035.528'
PUMPS: (2)5HP SERVICE VOLTAGE: 240V, 1 PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 6"PVC
....
.-
....
PHYSICAL DESCRIPTION:
-
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street and
has a service drive. Vehicle access to the station is possible from all sides.
....
NOTE: Lift station currently under construction. Actual site conditions may vary.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1240
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1022-1 High Level
1022-2 Main Power Failure
1022-3 Motor #1 Failure
1022-4 Motor #2 Failure
1022-5 Motor Control Power Failure
1022-6 Float Control Failure
08/14/01 10:38 AM
Station Data Sheet.doc
I
If"
1"1
STATION NO: 1022
NUECES ACRES
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
-....
JS-1022X Main Power Failure NEW Phase Failure Monitor Pump Control DI New station to be constr
Relay Panel
JS-1022Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1022Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1022A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10226 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1022 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1022 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1022A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10226 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1022A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10226 Pump #2 Overload DEMO Control Relay Pump Control, J
Panel
- - u__
Station Instrument Index Report
08/13/200105:43 PM
I
11
nr
~
....
.-
....
PICTURE NOT AVAILABLE
UFT STATION UNDER CONSTRUCTION
"
'"
"
;:;
~
C
N
N
"
11.11i II CORM CH"sn, " (J"l "2-2'"
II I EL PASO, 1)1 (915) 534-9110
SAlTLAKECJTY,UT. (801)161-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
I SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1022 - NUECES ACRES
I DR: DAILEY I DATE: 03/2000 I SHEET 1 OF 1
. --.-r
~
n
Wastewater Department
..... Microwave Communication System
City of Corpus Christi
Project No. 7100
-
....
~
"-
....
STATION NO.
1023
-
SOLAR ESTATES
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 023
SOLAR ESTATES
~
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 9201 Moonlight Street LOCALE: Rand Morgan and IH37
SUBDIVISION: Solar Estates WASTEWATER PLANT: Allison
LATITUDE: N27"49.945' LONGITUDE: W97032.674'
PUMPS: (2)5HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN: 6"PVC
....
....
-
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or fiexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type fioat switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1340
EXISTING STATION ALARMS:
.-
ALARM NO DESCRIPTION
1023-1 High Level
1023-2 Main Power Failure
1023-3 Motor #1 Failure
1023-4 Motor #2 Failure
1023-5 Motor Control Power Failure
1023-6 Float Control Failure
....
08/14/01 10:39 AM
Station Data Sheet.doc
III
rr
,
. 'I'
n
STATION NO: 1023
SOLAR ESTATES
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-l023X Main Power Failure NEW Phase Failure Monitor Pump Control DI ------
Relay Panel
JS-1023Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-l023Z RTU Ctrl Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-1023A 1st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1023B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1023 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1023 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1023A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-1023B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1023A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1023B Pump #2 Overload DEMO Control Relay Pump Control
Panel
-._--
Station Instrument Index Report
08/13/200105:43 PM
,.-
-
....
ELECTRIC
SERVICE
POLE
....
,....
.....
-
....
UTILITY CO.
METER AND
SERVICE DISC.
MOON
LIGHT DR.
~
,...
1-37 ACCESS RD.
-'-"
~
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
,-
-
11
"
o
"
w
C
..,
N
o
~
.-
1:111i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
.....
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH.
LIFT STA. 1023 - SOLAR ESTATES
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, TX. (361) 992-22114
El PASO, IX (915) ~-9110
ENGINEERING CORPORATION SAlT I.JJ([ CIlY, UT. (801) 261-1455
1
1
1
RTU
PANEL 1
ALARM
RELAY
PANEL 1
1
1
1
1
1
1
1
AND
1
1
1
PUMP CONTROL
PANEL
r:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
V ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\!...J ASSOCIATED UNISTRUT SUPPORTS.
r:;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
"
~
o
N
o
"
w
C
'"
N
o
It II Ii II CORPIIS CHOSTO. lX. (36') 992-"84
t I I n PASO. IX (915) 534-9110
SAlT LAKE CITY, UT. (BOI) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1023 - SOLAR ESTATES
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
-
J
PROJEct NO. 7100
1
r'-~
~
-
,....
,.....
,.....
,.....
1""
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
"'
c
ri
o
"
w
C
~
N
o
1::11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1023 - SOLAR ESTATES
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
El PASO, TX (915) 534-9110
5'LT lAKE CRY. UT. (SOl) 261-1455
ENGINEERING CORPORATION
.
"
11'"'
Wastewater Department
.... Microwave Communication System
City of Corpus Christi
Project No. 7100
....
.....
.....
....
....
STATION NO.
1024
~
-
CLARKWOOD NORTH
LIFT STATION
--, . 1
" .
"fj"
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 024
CLARKWOOD NORTH
....
STATION TYPE: Lifl Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: 2000 Clarkwood Road LOCALE: South of Leopard Street
SUBDIVISION: Sam Kane WASTEWATER PLANT: Allison
LATITUDE: N27049.148' LONGITUDE: W97032.163'
PUMPS: (2) 60HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN:
-
PHYSICAL DESCRIPTION:
The 11ft station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is not surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from all sides.
Electrical service to the 11ft station is routed overhead from pole mounted transformers. The electric
meter and main service disconnect are mounted on building exterior. Control equipment consists of
individual starters, Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are
mounted on the masonry wall. All control devices and pump sequencing controller are located in the
pump control panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with a pressure transducer sensor interfaced through control relays and
a pump sequencing controller. Trouble alarms are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1330
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1024-1 Drywell High Level
1024-2 Main Power Failure
1024-3 Motor #1 Failure
1024-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1024
CLARKWOOD NORTH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: g
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
--
JS-1024X Main Power Failure NEW Phase Failure Monitor Electrical Service DI
Relay Disc.
JS-1024Y Pump Ctrt Pwr Failure NEW Control Relay Pump Control DI
Panel
JS-l024Z RTU Ctrt Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1024A 1st Pump Start EXISTING Current Alarm Relay Level Control DI Pump control and RTU input
Panel
LS-10248 2nd Pump Start EXISTING Current Alarm Relay Level Control DI Pump control and RTU input
Panel
LSH-1024 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
..-----
LSHH-1024 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
YS-1024A Pump #1 Trouble EXISTING Soft Starter Alarm Contact Pump Control DI
Panel
YS-l0248 Pump #2 Trouble EXISTING Soft Starter Alarm Contact Pump Control DI
Panel
I --.- ----- -----
Station Instrument Index Report
08/13/200105:43 PM
-
.....
AVE W
DIRECTIONAL
ANTENNA
ELECTRIC SERVICE
WEATHERHEAD
....
CELANESE
TECH
CENTER
-
~
CHEMICAL
TANK
....
-
....
~
CLARKWOOD RD.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
\1
"l
o
"
w
o
..
N
o
1:111i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPuS CHRISTI, IX. (J61) 992-2284
E:L PASO. TX (91~) 534-9110
SAlT LAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1024 - CLARKWOOD NORTH
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
~--n
II'
11
RTU
PANEL
PUMP
CONTROL
PANEL
LTG.
PANEL
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
(3;) REWIRE EXISTING DRY AND WET WELL HIGH LEVEL FLOAT SWITCHES.
"
"
c
N
o
"
w
o
.
N
C
It II Ii II CORPIJS CHRISTI. TX. (361) 992-2184
II I n PASO. TX (915) S34-9ItO
SALT I.N<E CITY, UT. (BOI) 261-'455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1024 - CLARKWOOD NORTH
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
-
-
1
L
1
1
l
l
I
L.
1
1
L
1
I
....
1
J
1
1
ALARM
RELAYS
POWER FAiLURE ALARM
TRANSFORMER
~
....
~
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING AND RELAYS.
2. REWIRE EXISTING FLOAT SWITCHES.
3. REMOVE 480/120V AC TRANSFORMER (MAIN POWER FAILURE) AND
ASSOCIATED WIRING.
"
'"
o
ri
o
:>
w
c
V
N
C
1:111i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1024 - CLARKWOOD NORTH
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPvS CHRISTI, IX. (361) 992-2284
E1 PASO. TlI (915) 5304-9110
SAlTlAKECITY.UT. (801)261-1455
ENGINEERING CORPORATION
Wastewater Department
... Microwave Communication System
City of Corpus Christi
Project No. 7100
...
...
....
....
STATION NO.
1025
CLARKWOOD SOUTH
LIFT STATION
,-
- I r 11" [1"
n
~
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 025
CLARKWOOD SOUTH
STATION TYPE: Lift Station: Wet well, (2) submersible pumps [
ADDRESS: 1025 Clarkwood South LOCALE: South of SH 44
SUBDIVISION: Clarkwood Townsite WASTEWATER PLANT: Allison
LATITUDE: N27"46.684' LONGITUDE: W97032.360'
PUMPS: (2) 35HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 12"VCP FORCE MAIN: 10"VCP
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1160
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1025-1 High Level
1025-2 Main Power Failure
1025-3 Motor #1 Failure
1025-4 Motor #2 Failure
1025-5 Motor Control Power Failure
1025-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheel.doc
STATION NO: 1025
CLARKWOOD SOUTH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
--
JS-1025X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1025Y Pump Ctr1 Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1025Z RTU Clrl Pwr Failure NEW 120VAC Digilallnpul RTU Panel DI
LS-1025A 1st Pump Start EXISTING Float Switch New Junction Box DI l~ntrinsicallY safe barrier relay
required
LS-1025B 2nd Pump Slarl EXISTING Float Switch New Junction Box DI l~ntrinsicallY safe barrier relay
required
LSH-1025 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1025 Wet Well Low level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1025A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1025B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1025A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1025B Pump #2 Overload DEMO Control Relay Pump Control
Panel
--.
Station Instrument Index Report
08/13/200105:43 PM
-
-
ELECTRIC
SERVICE
POLE
-
DIRECTIONAL
ANTENNA
CLARKWOOD
SOUTH RD.
PAVED
DRIVE
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
L>
'"
o
o
"
w
C
on
N
C
CITY Of CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
.-
1:111i11
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1025 - CLARKWOOD SOUTH
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, lX. (J61) 992-2284
[l PASO, TX (915) 534-9110
SALT lAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
.
w
'I"T
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1025 - CLARKWOOD SOUTH
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
UTILITY CO.
DISC.
PUMP CONTROL
PANEL
RTU
PANEL
SERVICE
DISC.
WET WELL
ACCESS
r:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
~ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
"
~
N
o
"
w
C
on
N
o
It II Ii II COIlPUS CHRISTI. TX. ("") "2-228'
II I E1 PASO. IX (9\5) ~-9110
SAlT lAKE CITY, UT. (801) 261-1-4~
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
'"
I"W'
-
1
1
1
ALARM
RELAY i
PANEL
L
1
L
L
L
L
L
L
AND
L
L
l
L
PROJECT NO. 7100
L
....
....
FLOAT SWITCH
TERMINAL STRIP
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
~
,-;
o
"
w
o
"
N
o
~.
1::1 Ii II
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI. TX. (361) 992-2284
EL PASO. TIC (915) 534-9110
SAlT tAKE CITY. UT. (801) 261-1<455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1025 - CLARKWOOD SOUTH
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
-
....
Wastewater Department
- Microwave Communication System
City of Corpus Christi
Project No. 7100
~
--
....
~
STATION NO.
1026
INTERNATIONAL AIRPORT
LIFT STATION
- ~
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 026
INTERNATIONAL AIRPORT
....
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: International Airport LOCALE: International Drive, South of SH 44
SUBDIVISION: International Airport WASTEWATER PLANT: Greenwood
LATITUDE: N27046.479' LONGITUDE: W97030.036'
PUMPS: (2) 40HP SERVICE VOLTAGE: 20SV, 3PH, 4W
INFLUENT PIPE(S): S"VCP FORCE MAIN: 10"VCP
....
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street.
Vehicle access to the station is possible from all sides.
....
NOTE: Lift station currently under construction. Actual site conditions may vary.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 125"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1026-1 WetwelJ High Level
1026-2 Main Power Failure
1026-3 Motor #1 & #2 Failure
1 026-4 Drywell High Level
08/13/01 5:12 PM
Station Data Sheet.doc
.
.
STATION NO: 1026
INTERNATIONAL AIRPORT
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
- Phase Failure Monitor
JS-1026X Main Power Failure NEW Pump Control DI
Relay Panel
JS-1026Y Pump Ctn Pwr Failure NEW Control Relay (120 VAC Pump Contro{ DI
coil) Panel
JS-1026Z RTU CIrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
- Float Switch New Junction Box DI
LS-1026A 1 st Pump Start EXISTING Intrinsically safe barrier relay
required
LS-1026B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1026 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSHH-1026 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1026 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1026A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1026B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1026A Pump #1 Over1oad DEMO Control Relay Pump Control
Panel
~S-102:l Pump #2 Overload DEMO Control Relay Pump Control
Panel
--
Station Instrument Index Report
08/13/2001 05:43 PM
11 r
111'
1
-
~
....
~
PICTURE NOT AVAILABLE
UFT STAnON UNDER CONSTRUCTION
"
"
c
o
"
w
o
~
N
o
It .1 Ii II CORM ,,",n. " (3") 992-228'
II I [L PASO. lX (915) 5J4-9110
SAlT WE CITY, Ul. (801) 261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
I SCALE: N.T.S.
11
II'
r
-.... "
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1026 - INTERNATIONAL AIRPORT
I DR: DAILEY I DATE: 03/2000 I SHEET 1 OF 1
nr
Wastewater Department
.... Microwave Communication System
City of Corpus Christi
Project No. 7100
....
....
~
STATION NO.
1027
STILLWELL
LIFT STATION
,. ,. ","' ~~ . .", , '
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 027
STILLWELL
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: 8100 Stillwell Lane LOCALE: South of SH 9 & Tuloso Road
SUBDIVISION: Main Dr. & Gulley's Trailer Park WASTEWATER PLANT: Allison
LATITUDE: N27"48.90T LONGITUDE: W97"31.43T
..-.---
PUMPS: (2) 25HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN: 12"CIP
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from two sides.
Electrical service to the lift station is routed overhead from pole mounted transformers. The electric
meter is mounted on service pole and main service disconnect is located in building interior. Control
equipment consists of a Switchboard wi starters, Pump Control Panel, RTU panel, and alarm relay
panel. All enclosures are mounted on the masonry wall. All controi devices, except level control
relays and pump sequencing controller are located in the Switchboard. Conduits are rigid or flexible
PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 135"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1027-1 Wet I Drywell Level
1027-2 Main Power Failure
1027-3 Motor #1 Failure
1027-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet. doc
I r
II
1r
STATION NO: 1027
STILLWELL
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
-.-----
JS-1027X Main Power Failure NEW Phase Failure Monitor Switchboard DI
Relay
JS-1027Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1027Z RTU Ctrl Pwr Failure NEW 120V AC Digital Input RTU Panel 01
LS-1027A 1 st Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS-10278 2nd Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LSH-1027 Wet Well High Level EXISTING Float Switch Switchboard DI Intrinsically safe barrier relay
required
'LsHH-"1027 1--- - EXISTING Float Switch Switchboard 01 Intrinsically safe barrier relay
Dry Well High Level
required
LSL-1027 Wet Well Low Level EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
XS-1027A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-10278 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1 027 A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10278 Pump #2 Overload DEMO Control Relay Pump Control
Panel
------- L--____ ---------~---
Station Instrument Index Report
08/13/200105:43 PM
-
.
STILLWELL LN.
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
'"
"!
;:;
"
w
C
~
N
C
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1027 - STillWEll
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, IX. (J61) 992-2284
El PASO. Tx (915) 5J4-9110
SAlT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
- ~
WET WELL HIGH 1
LEVEL FLOAT
SWITCH CABLE
1
NEW PHASE
FAILURE 1
MONITOR
RELAY
1
1
1
1
1
1
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1027 - STillWEll
DATE: 03/2000 SHEET 2 OF 3
PUMP
CONTROL
PANEL
SWITCHBOARD
RTU
PANEL
ALARM
RELAY
PANEL
PUMP
MOTOR
DRY WELL HIGH LEVEL
FLOAT SWITCH CONDUIT
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
"
15
N
o
"
w
C
~
N
o
CD
G
INSTALL NEW PHASE FAILURE MONITOR RELAY.
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
1:111i11
ENGINEERING CORPORATION
CITY OF" CORPUS CHRISTI
WASTEWATER DEPT.
CORPUS CHRISTI, IX. (361) 992-2284
(l PASO. 1X (915) 5J.4-9110
SAlT l.Al([ CITY, UT. (BOI) 261-1455
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
PUMP
MOTOR
1
1
L
L
L
L
L
PROJECT NO. 7100
L
-
C>
~
c
.-;
o
"
w
C
~
N
o
1:111i11
ENCINEERING CORPORATION
JOB NO.: 1075
.
I'
"'-,
/02.?
"'l ...
1. TRACE OUT MECHANICAL LEVEL SWITCHES AND
ROUTE STATUS TO RTU.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISTI
WASTEWATER D[PT.
PROJECT NO. 7100
CORPUS CHRISTI. lX. (361) 992-2284
Et PASO. 1X (915) 5~-9110
SAlT lAKE CITY. UT. (801)251-1-455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1027 - STillWEll
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
. .--
1'"
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1028
LEVI/COUNTY JAIL
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1028
LEVI/COUNTY JAIL
STATION TYPE: Lift Station: Wet well, (2) sul:lmersil:lle pumps
ADDRESS: 745 North Padre Island Dr. LOCALE: South of SH 44 & Forrest Lane
SUBDIVISION: Levi Strauss WASTEWATER PLANT: Greenwood
LATITUDE: N27046.595' LONGITUDE: W9J028.174'
PUMPS: (2)3HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 8"VCP FORCE MAIN: 6"CIP
PHYSICAL DESCRIPTION:
-
The lift station is an open air facility consisting of a I:lelow grade wet well with sul:lmersil:lle pumps. The
wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street and
has a service driveway. Vehicle access to the station is possil:lle from all sides. Lift station is situated
underneath overhead electrical.
Electrical service is routed from an overhead service pole. The electric meter and service disconnect
are located on the service pole. Control equipment consists of a Pump Control Panel, RTU panel, and
alarm relay panel. All enclosures are mounted on service pole. All control devices, including pump
motor starters, are located in the Pump Control Panel. Conduits are rigid or flexil:lle PVC. Enclosures
and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Troul:lle alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1410
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1028-1 High Level
1028-2 Main Power Failure
1028-3 Motor #1 Failure
1028-4 Motor #2 Failure
1028-5 Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1028
LEVIICOUNTY JAIL
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FJELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
! JS-1 028A --_.- -
Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-1028B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1028X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1028Y Pump Gtrl Pwr Failure NEW Control Relay (24 VAC Pump Control DI
coil) Panel
JS-1028Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1028A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
---~-_.- -- - ~,_._-
LS-1028B 2nd Pump Start EXISTING Float Switch New Junction Box DJ Intrinsically safe barrier relay
required
LSH-1028 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1028 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1028A Pump #1 Run Status NEW Motor Starter N.Q. Aux Pump Control DI
Contact Panel
- NEW Motor Starter N.O. Aux Pump Control DI
XS-1028B Pump #2 Run Status
Contact Panel
YS-1028A Pump #1 Overload DEMO Control Relay Pump Control
Panel
._--~--_.. .~ ...---..
YS-1028B Pump #2 Overload DEMO Control Relay Pump Control
Panel
--.-
Station Instrument Index Report
08/13/200105:43 PM
.
II
'"rl
....
....
DIRECTIONAL
ANTENNA
ELECTRIC SERVICE
POLE
-
WET WELL
ACCESS
-
PADRE ISLAND
DRIVE
FRONTAGE
ROAD
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
!;":
c
o
"
w
C
'"
N
o
I, .1 Ii II CORPUS CH"'. lX. ("'J 992-2284
El PASO, TX (915) 534-9110
II I SAlT lAKE CrTY,UT. (801)261-1455
ENGINEERINC CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1028 - LEVI/COUNTY JAIL
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.
I
r
RTU
PANEL
J
1
J
PUMP CONTROL 1
PANEL
ALARM
RELAY
PANEL
r:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
1e
c
N
o
"
w
C
'"
N
o
I, II Ii II CORPuS CHRISTI. ". (>61) 99'-228'
Ilt t EL PASO. TX (915) 534-9110
ENGINEERING CORPORATION ~T l.AltE CITY. Uf. (801) 261-1455
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
1
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1028 - LEVI/COUNTY JAIL
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
I .
II
1'1
1
1
1
1
J
1
1
1
1
1
1
1
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
co
,.
c
..;
o
"
w
C
'"
N
C
1:111i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1028 - LEVI/COUNTY JAIL
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, lX. (J61) 992-2284
El PASO, TX (915) 5J4-9110
SAlTlAKECrTY,UT. (801)261-1455
ENGINEERING CORPORATION
- ..
I.
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
STATION NO.
1029
CIMMARON
LIFT STATION
... ... I 1'1 , ... ' ,
'1"1
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1029
CIMMARON
~
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 7501 Cimmaron LOCALE: Cimarron and Yorktown
SUBDIVISION: King's Crossing WASTEWATER PLANT: Greenwood
LATITUDE: N2J039.553' LONGITUDE: W97022.970'
PUMPS: (2) 20HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN: 12"ACP
~
....
....
PHYSICAL DESCRIPTION:
....
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street with a service driveway. Vehicle access to the
station is possible from two side. Lift station is situated near overhead electrical.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in 900d
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 332"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1029-1 High Level
1029-2 Main Power Failure
1029-3 Motor #1 Failure
1029-4 Motor #2 Failure
1029-5 Motor Control Power Failure
1029-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
....'
.
-
STATION NO: 1029
CIMMARON
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
-- ...-.-.-- ~.- - -. --
JS-1029A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-10298 Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1029X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-1029Y Pump Girl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-1029Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-1029A 151 Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
-L:S-1029B 2nd Pump Start EXISTiNG Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-1029 Wet Well High level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-1029 I Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-1029A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-10298 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-1029A Pump #1 Overtoad DEMO Control Relay Pump Control
Panel
-_.-- -.-- u--i
YS-10298 Pump #2 Overload DEMO Control Relay Pump Control I
Panel
-. -- ~----,_._- ~--_._- - --
Station Instrument Index Report
08/13/200105:43 PM
---,
n
r:
.....
CHEMICAL
TANK
SUBSTATION
-
....
ELECTRIC
SERViCE
POLE
CIMMARON
BLVD.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"'
~
'"
o
"
w
o
'"
N
o
1:111i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1029 - CIMMARON
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTl. TX. (361) 992-2284
EL PASO. TX (915) 534-9110
SAlT LAKE CITY, UT. (BOI) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
-
r'II'
-"1
RTU
PANEL
ALARM
RELAY
PANEL
SPLICE
BOX
"
;0
o
N
o
"
w
C
'"
N
C
PUMP CONTROL
PANEL
/--:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
V ASSOCIATED UNISTRUT SUPPORTS.
;';\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
;-;\, REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
CITY Of CORPUS CHRISTl
WASlEWATER DEPT.
11111i II CORPllS CH'OT, lX. (361) "2-228'
tiEL PASO. IX (915) 534-9110
SALT lAKE CITY, UT. (801) 261-1"55
ENGINEERING CORPORATION
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1029 - CIMMARON
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
I
SCALE: N.T.S.
DR: DAILEY
11
fl
1
1
1
1
1
1
1
1
1
1
1
1
AND
1
1
J
1
PRQUECT NO. 7100
1
~
1. TRACE OUT AND REMOVE ALL EXISTlNG- ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
~
c
ri
o
"
w
C
co
N
o
1::11i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1029 - CIMMARON
DATE: 03/2000 SHEET 3 OF 3
CORPuS CHRISTI, TX. (J61) 992-2284
EL PASO. 1X (915) 534-9110
SALTl..AKECllY.UT. (801)261-1455
ENGINEERING CORPORATION
DR: DAILEY
_ r
-,
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~.
~
~
~
~
STATION NO.
1030
MCBRIDE
LIFT STATION
- 1 r 11'
." "q., ,
If
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 030
MCBRIDE
STATION TYPE: Lift Station: Wet well, Dry well, (3) vertical pumps
ADDRESS: 1200 McBride Lane LOCALE: South of Up River Road
SUBDIVISION: Ebony Acres & Country Club WASTEWATER PLANT: Broadway
LATITUDE: N27048.584' LONGITUDE: W97027.633'
PUMPS: (2) 30HP & (1) 100HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 24" VCP FORCE MAIN: 16"CIP
PHYSICAL DESCRIPTION:
The lift station Is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from one side.
Electrical service to the lift station is routed overhead from pole mounted transformers. The electric
meter is mounted on building exterior and main service disconnect is located in building interior.
Control equipment consists of individual starters, Pump Control Panel, RTU panel, and alarm relay
panel. All enclosures are mounted on the masonry wall. All control devices and pump sequencing
controller are located in the pump control panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Wood, 45 ft, Class 5 (New)
Antenna Mounting Elevation: 40 fl. - Azimuth: 1590
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1030-1 Wetwell High Level
1030-2 Main Power Failure
1030-3 Motor #1, #2, & #3 Failure
1030-4 Drywell High Level
08/13/01 5:12 PM
Station Data Sheet. doc
-
STATION NO: 1030
MCBRIDE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 12
ANALOG INPUTS, 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS, 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
I ,,-- Phase Failure Monitor Pump Control DI
JS-1030X Main Power Failure NEW
Relay Panel
JS-1030Y Pump Ctrl Pwr Failure NEW Control Relay (120 VAC Pump Control DI I
coil) Panel
JS-1030Z RTU Gtrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-103DA 1st Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS-10308 2nd Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS-1030C 3rd Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
- --~-_.- .-.
LSH-1030 Wet Well High Level EXISTING Float Switch Wireway DI Intrinsically safe barrier relay
required
LSHH-1030 Dry Well High Level EXISTING Float Switch Wireway DI Intrinsically safe barrier relay
required
LSL-1030 Wet Well Low Level EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
XS-1030A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10308 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-1030C Pump #3 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
~- Pump Control - .._-~
YS-1030A Pump #1 Overload DEMO Control Relay
Panel
YS-10308 Pump #2 Overload DEMO Control Relay Pump Control
Panel
YS-1030C Pump #3 Overload DEMO Control Relay Pump Control
I Panel
- -.
Station Instrument Index Report
08/13/200105:43 PM
.
I
1"1
DIRECTIONAL ANTENNA
MOUNTED ON BACK
OF PUMP BLDG.
..
....
-
CHEMICAL
TANK
.-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
~
o
"
w
C
o
'"
o
1:11 Ii II
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, lX. (361) 992-2284
[L PASO, TX (915) 534-9110
SALT lAKE CITY, uf. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1030 - McBRIDE
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
I
r
- ._-
,..
TRANSFORMER
LIGHTING
PANEL
PUMP
STARTERS
PUMP
MOTORS
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
(3) DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
'-'
~
N
o
"
w
C
'-'
n
'-'
II-Iii II CORPIJS CH.,;n. TX. ("') 99'-2284
n PASO. TX (915) 534-9110
II I SALT lAK[ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1030 - McBRIDE
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
.
I
r
1
i
L
ANTENNA 1
CABLE
t
RTU
PANEL 1
ALARM 1
RELAY
PANEL
L
L
1
L
1
1
L
L
L
L
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. TRACE OUT MECHANICAL LEVEL SWITCHES AND ROUTE STATUS
TO RTU.
"
"
c
ri
o
"
w
C
C
'"
o
1:111i11
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1030 - McBRIDE
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, TX. (J61) ~2-2284
[l PASO. 1X (1115) 534-9110
SAlT I.AI(( CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
- ...
-"
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1031
HIGHWAY 9
LIFT STATION
~.. _.. I ,. I -,
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1031
HIGHWAY 9
....
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 6724 Leopard Street : LOCALE: Leopard Street and Diamond Cut
SUBDIVISION: Alleh & Cameron Industrial Area WASTEWATER PLANT: Broadway
LATITUDE: N27048.288' LONGITUDE: W97029.70T
PUMPS: (2) 20HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): 10"VCP FORCE MAIN: 8"VCP
-
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and has a service driveway. Vehicle access to
the station is possible from three sides.
Electrical service is routed to the lift station from an overhead service pole. The electric meter and
service disconnect are located on the service pole. Control equipment consists of a Pump Control
Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry wall on
metal strut support brackets. All control devices, including pump motor starters, are located in the
Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1410
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1031-1 Hi9h Level
1031-2 Main Power Failure
1031-3 Motor #1 Failure
1031-4 Motor #2 Failure
1031-5 Motor Control Power Failure
1031-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1031
HIGHWAY 9
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
JS-1031A I -- I I
Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-1031B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1031X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1031Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1031Z RTU Gtrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1031A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
I required
I Newji.mction Box ,-.-
LS.1031B 2nd Pump Start EXISTING Float Switch DI Intrinsically safe barrier relay
required
LSH-1031 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1031 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1031A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1031B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1031A Pump #1 Overload DEMO Control Relay Pump Control
Panel
-
YS-1031B Pump #2 Overload DEMO Control Relay Pump Control
Panel
- -- -
Station Instrument Index Report
08/13/200105:43 PM
.
I.
-
ELECTRIC SERVICE
POLE
VALVE BOX
ACCESS
-
-
UTILITY CO.
METER AND
SERVICE DISC.
MANHOLE
-
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
"
"!
o
"
w
C
'"
C
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (361) 992-2284
[l PASO, TX (915) 5~-91l0
SAlT lAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1031 - HIGHWAY 9
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
RTU
PANEL
ALAR M
RELAY
PANEL
G
(3)
o
J
1
1.
PUMP CONTROL 1.
PANEL
1
1
1
1
1
1
1
l
DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1031 - HIGHWAY 9
DATE: 03/2000 SHEET 2 OF 3
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
"
'"
c
N
o
"
w
c
n
o
1:11 Ii II
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
CORPUS CHRISTI, IX. (J61) 992-2284
U PASO. IX (915) S.}4-9110
SAlT tAKE CITY, UT. (801) 261-1455
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
I
:1
" ...-
1.
J
1
L
PROJECT NO. 7100
1
J"1
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'-'
;0
'"
.0
o
"
w
C
..,
o
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (J61) 992-2284
(L PASO, tx (915) ~-91IO
S1.LTlAKE CrTY,UT. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1031 - HIGHWAY 9
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
~ ,.
~
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
....
....
STATION NO.
1032
MORGAN
LIFT STATION
- .. r 11 .
~ ,.-.. "., ,
If
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1032
MORGAN
....
STATION TYPE: Lift Station: Wet well, Dry well, (3) vertical pumps
ADDRESS: 1400 12th Street LOCALE: South of Morgan Avenue
SUBDIVISION: WASTEWATER PLANT: Broadway
...-
LATITUDE: N27046.645' LONGITUDE: W97024.294'
PUMPS: (3) 20HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 24" VCP FORCE MAIN: 24"CIP
~
....
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. Lift pumps
are located in the dry well and the top of the structure is flush with grade. Vehicle access to the station
is possible from all sides.
Electrical service to the lift station is routed overhead from pole mounted transformers. The electric
meter is mounted on service pole and main service disconnect is located on building exterior. Control
equipment consists of individual starters, Pump Control Panel, RTU panel, and alarm relay panel. All
enclosures are mounted on the masonry wall. All control devices and pump sequencing controller are
iocated in the pump control panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in
good cond ition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1990
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1032-1 Drywell High Level
1032-2 Main Power Failure
1032-3 Motor #1, #2, & #3 Failure
1032-4 Drywell High Level
08113/01 5:12 PM
Station Data Sheet.doc
.
I
f'
STATION NO: 1032
MORGAN
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 12
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
':!S:1032X Main Power Failure NEW Phase Failure Monitor Circuit Breaker DI
Relay Ene!.
JS-l032Y Pump Ctrl Pwr Failure NEW Control Relay (120 VAC Pump Control DI
coil) Panel
JS-l032Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1032A 1st Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS-1032B 2nd Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS- 1 032C 3rd Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LSH-1032 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSHH-1032 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1032 Wet Well low Level EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
XS-1032A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-1032B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1032C Pump #3 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1032A ------
Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1032B Pump #2 Over1oad DEMO Control Relay Pump Control
Panel
YS-1032C Pump #3 Over1oad DEMO ~Control Relay Pump Control
Panel
L--. .__ -,_. ._ .n.. "___ ____.____ - --
Station Instrument Index Report
08/13/200105:43 PM
.
I
.,..
~
....
ELECTRIC
SERVICE
POLE
....
CHEMICAL
TANK
~
UTILITY CO.
METER AND
SERVICE
DISC.
12TH ST.
CHEMICAL INJECTION
PUMP ENCL.
WET WELL
ACCESS
11TH ST.
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
~
c
o
"
w
C
N
,.,
o
1:111i11
ENGINEERING CORPORATION
JOB NO.: 1075
-
CORPUS CHRISTI, lX. (361) 992-2284
[l PASO, IX (915) 5l4-91l0
SAlT lAKE CITY, UT. (801) 261-1455
SCALE: N.T.S.
CITY OF" CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1032 - MORGAN
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
L
ALARM
RELAY
PANEL
WET WELL HIGH LEVEL
FLOAT SWITCH CABLE
LIGHTING PANEL
1
1
1
RTU
PANEL
TRANSFORMERl
1
J
J
1
1
1
1
CIRCUIT BREAKER DRY WELL HIGH LEVEL
AND MOTOR STARTER FLOAT SWITCH CABLE
(3 TYP.)
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
L
L
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
l
~
c
N
o
'"
w
C
N
'"
o
JOB NO.: 1 075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1032 - MORGAN
DATE: 03/2000 SHEET 2 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
[l PASO, IX (illS) 534-9110
SAlT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
.
,.
~ .~"
.."
"
"
o
..;
o
"
w
C
N
n
C
1:111i11
ENGINEERING CORPORATION
JOB NO.: 1075
-
-
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1032 - MORGAN
DATE: 03/2000 SHEET 3 OF 3
It> ~z.
1. TRACE OUT MECHANICAL LEVEL SWITCHES AND
ROUTE STATUS TO RTU.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
CORPUS CHRISTI, IX. (361) 992-2284
[l PASO, TK (!lIS) 5l4-9110
SAl.llA1([ CITY. UL (801) 261-1455
SCALE: N.T.S.
DR: DAILEY
FLOAT SWITCH
TERMINAL STRIP
PROVECT NO. 7100
Wastewater Department
.... Microwave Communication System
City of Corpus Christi
Project No. 7100
~
STATION NO.
1033
BROWNLEE
LIFT STATION
. -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1033
BROWNLEE
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
I ADDRESS: 810 N. Brownlee LOCALE: West of Staples
i SUBDIVISION: Crossgate WASTEWATER PLANT: Broadway
LATITUDE: N27"47.841, LONGITUDE: W97"24.506'
PUMPS: (2)3HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN:
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well and dry well structure. Lift
pumps are located in the dry well and the top of the structure is flush with grade. The station is located
adjacent to the street and has a service driveway. Vehicle access to the station is possible from all
sides.
Electrical service to the lift station is routed underground from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on metal support
brackets. All control devices, including pump motor starters, are located in the Pump Control Panel.
Conduits are rigid or flexible PVC. Enclosures and conduits are in poor condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 30 ft. - Azimuth: 1920
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1033-1 Wetwell High Level
1033-2 Main Power Failure
1033-3 Motor #1 Failure
1033-4 Motor #2 Failure
1033-5 Drywell High Level
1033-6 Motor Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
.
I
T
STATION NO: 1033
BROWNLEE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
~-- -
JS-1033A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-10338 Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1033X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1033Y Pump CtrI Pwr Failure NEW Control Relay (120 V AC Pump Control DI
coil) Panel
JS-1033Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1033A 1st Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
-~'_.-_. -
LS-10338 2nd Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LSH-1033 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSHH-1033 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1033 Wet Well Low Level EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
XS-1033A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10338 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
---
YS-1033A Pump #1 Overload DEMO Control Relay Pump Control !
Panel
YS-10338 Pump #2 Overload DEMO Control Relay Pump Control
Panel
----~-- _.-._-- -------
Station Instrument Index Report
08/13/200105:43 PM
---.,
r
I
~'
. _..
11'
LOVENSKIOLD
PARK
DIRECTIONAL
ANTENNA
-
ELECTRIC
SERVICE
POLE
,
CROSSTOWN
EXPWY.
BROWNLEE
BLVD.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
o
"
w
C
....
....
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER OEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1033 - BROWNLEE
DATE; 03/2000 SHEET 1 OF 3
CORPUS CHRISlI, lX. (J61) 992-2284
[L PASO. TX (915) 534-9110
SAl.Tl.Al<[ClTY.UT. (1101)261-1455
ENGINEERING CORPORATION
DR: DAILEY
--,
r
- ..",,"
T
l
r-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
AND
L
L
L
L
L
L
1
L
l
L
L
L
L
DRY WELL
ACCESS
~
RTU
PANEL
li'. 11"
:-131
PUMP
CONTROL
PANEL
ALAR M
RELAY
PANEL
MECHANICAL
LEVEL SWITCH
ENCLOSURE
WET WELL
HIGH LEVEL
FLOAT SWITCH
CONDUIT
WET WELL
ACCESS
'"
'"
c
N
o
"
w
C
....
....
o
~
11111i II CORPUS 0<0"". TX. '''') 99'-228'
I tiEl PASO, TX (915) 534-9110
ENGINEERING CORPORATION SAlT lAK[ CllY, UT. (801) 261-1455
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1033 - BROWNLEE
DATE: 03/2000 SHEET 2 OF 3
DR: DAILEY
1 r
11
Jr
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
~
,.;
o
"
w
C
'"
'"
o
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (361) 992-2284
F;L PASO. TX (915) 534-9110
5.l.LTlAXECllY,UT. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1033 - BROWNLEE
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
-
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1034
TROJAN
LIFT 5T A TION
..- _ r
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1034
TROJAN
~
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 1901 Trojan Avenue LOCALE: West of SH 286
SUBDIVISION: Teachers' Credit Union WASTEWATER PLANT: Greenwood
LATITUDE: N27044.533' LONGITUDE: W97025.945'
PUMPS: (2)3HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 8"CIP FORCE MAIN: 4"CIP
-
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed to the lift station from an overhead service pole. The electric meter and
service disconnect are located on the service pole. Control equipment consists of a Pump Control
Panel, RTU panel, and alarm relay panel. All enclosures are mounted on service pole. All control
devices, including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1540
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1034-1 High Level
1034-2 Main Power Failure
1034-3 Motor #1 Failure
1034-4 Motor #2 Failure
1034-5 Motor Control Power Failure
1034-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1034
TROJAN
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
'JS~f034A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-l034B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-l034X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-l034Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-l034Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-l034A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
I LS-l034B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-l034 Wet Well High level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-l034 Wet Well low level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-l034A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control Di
Contact Panel
XS-l034B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-l034A Pump #1 Overtoad DEMO Control Relay Pump Control
Panel
,.-... Pump Control
YS-l034B Pump #2 Overtoad DEMO Control Relay
Panel
---.... -~
Station Instrument Index Report
08/13/2001 05:43 PM
----,--r
It
TT
TROJAN
DRIVE
PRESCOTT
STREET
DIRECTIONAL
ANTENNA
-
-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
,.
"
o
:>
w
o
v
'"
o
1==11111
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1034 - TROJAN
DATE: 03/2000 SHEET 1 OF 3
CORPuS CHRISTl, IX. (361) 992-2284
[l PASO, TX (91~) 534-9110
ENGINEERING CORPORATION SALT I..AJ([ CITY, UT. (801) 261-'455
DR: DAILEY
DIRECTIONAL
ANTENNA
RTU
PANEL
ELECTRiC
SERVICE
POLE
J
1
1
PUMP CONTROL 1
PANEL
ALARM
RELAY
PANEL
r-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
~ ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
o
0)
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
"
,.
o
N
o
:>
w
o
~
..,
o
It II Ii II CORPUS CHOS1l. TX. (J6I) 99'-"8'
II El PASO. TX (915) ~-g110
SAlT LAIC[ CllY, UT. (801) 261-US5
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1034 - TROJAN
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
1
11
Tr
J
J
J
J
1
J
J
1
J
1
1
1
1
~
-
-
-
-
-
'"
,.
"
.-;
"
"
w
"
v
..,
"
1::11i11
ENGINEERING CORPORATION
JOB NO.: 1075
-
I.
fO?'..,
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRiNG.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, IX. (361) 992-2284
[l PASO. Tx (915) 5~-9110
So\lTlAKE CITY, uT. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1034 - TROJAN
DATE: 03/2000
SCALE: N.T.S.
DR: DAILEY
SHEET 3
OF 3
-.
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
-
STATION NO.
1035
-
-
-
MISSION
LIFT STATION
- ~ -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1035
MISSION
, STATION TYPE: Lift Station: Wet well, (2) submersible pumps
!-_....._--~-- -~._.........._---._......._._-- .....---- .........._---.
I ADDRESS: 4931 Ayers Street I LOCALE: East of SH 286
I SUBDIVISION: Mission Shopping Ctr. (Off--j-~~S~E~~;E~PLANT: Greenwood .----
: Cross~l?""n J\~cess Rd~___________________---i .......... .....u _ ...... ....... .__
I LATITUDE: N27044.419' : LONGITUDE: W97"25.685'
L___.__.___."____~~___________.__...,._________.__..____--------..--....----f--. ..m _ ...... .._n___ ......... ..__m__ .... ....... __ _ __ ___ .._.... ....,
i '
PUMPS: (2) 5HP ! SERVICE VOLTAGE: 240/120V, 3PH, 4W
, ,
,..-.------~.._---_.---.-~----.-.--~--___._.....,_,._.____m_m__""_""_'__ _ ,___.............,.......___._________ __m..... __ ___
: INFLUENT PIPE(S): B" VCP
FORCE MAIN: 4" CIP
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a concrete wall. The
station is located adjacent to a parking lot and does not have a service driveway or security fence.
Vehicle access to the station is possible from three sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1660
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1035-1 High Level
1035-2 Main Power Failure
1035-3 Motor #1 Failure
1035-4 Motor #2 Failure
1035-5 Motor Control Power Failure
1035-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
I ~
II
1'1
STATION NO: 1035
MISSION
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
~ --
JS-l035A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-l035B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-l035X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l035Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-l035Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-1035A 1st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
---"-_._-
LS-l035B 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-l035 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-l035 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l035A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l035B Pump #2. Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-l035A Pump #1 Overload DEMO Control Relay Pump Control
Panel
e------. --~._-- Pump Control
YS-l035B Pump #2 Over1oad DEMO Control Relay
Panel
Station Instrument Index Report
08/13/200105:43 PM
1
I
r
....
ELECTRIC
SERVICE
POLE
....
....
.... ENTRANCE
TO MISSION
SHOPPING
CENTER
....
CROSSTOWN EXPWY.
FRONTAGE ROAD
UTILITY CO. METER
AND SERVICE DISC.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
o
"
w
o
'"
..,
o
11111i II CORPuS CH~S". TX. (J"> '92-228'
II I n PASO, 1X (915) 5J4-9110
SAlT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1035 - MISSION
DATE: 03/2000 SHEET 1 OF 3
OR: DAILEY
. ..
I.
'1"1
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1035 - MISSION
DATE: 03/2000 SHEET 2 OF 3
ALARM
RELAY
PANEL
PUMP CONTROL
PANEL
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
"
,.
"
'"
o
"
~
"
"'
..,
"
It II Ii II CORPUS CH~S1]. 1~ (361) 992-"84
I tin PASO. IX (1115) ~-9110
ENGINEERING CORPORATION SAlT lAJ([ CITY, Uf. (SOl) 261-'4~
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
1
J
J
1
1
J
1
1
1
1
1
1
AND
L
L
L
PROJECT NO. 7100
L
l
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
co
~
o
.-;
o
~
w
o
"'
n
o
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
ENGINEERING CORPORATION
CORPuS CHRISTl, TX (361) 992-228.
El PASO. TX (915) 534-9110
SAl.llAKE CITY, UT. (801) 261-1<455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1035 - MISSION
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1036
ARCADIA
LIFT STATION
..- . r ..-_. I" r , --,
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1036
ARCADIA
STATION TYPE: Lift Station: Wet well, (4) submersible pumps
ADDRESS: 2221 South Staples LOCALE: Kosar & York (East of Del Mar Campus)
SUBDIVISION: Arcadia WASTEWATER PLANT: Oso
LATITUDE: N27045.836' LONGITUDE: W97024.221,
PUMPS: (1) 20HP, (4) 40HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 12"CIP
PHYSICAL DESCRIPTION:
The lift station is a prefabricated metal building housing the electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Vehicle access to
the station is possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is located on building exterior. Control equipment consists of a Motor Control Center
(MCC), Pump Control Panel, RTU panel, and alarm relay panel. RTU panel is mounted on interior
wall. Pump Control Panel and alarm relay panel are located in the MCC. Conduits are rigid or flexible
PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 20r
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1036-1 High Level
1036-2 Main Power Failure
1036-3 Motor #1 & #2 Failure
1036-4 Motor #3 & #4 Failure
08/13/01 5:12 PM
Station Data Sheet. doc
.
I
r
STATION NO: 1036
ARCADIA
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 15
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
r JS-l036X Main Power Failure EXISTING Phase Failure Monitor - --
MCC 01
i Relay
JS-l036Y Pump Gtrl Pwr Failure NEW Control Relay (120 VAC Pump Control 01
coil) Panel
JS-l036Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l036A 1st Pump Start EXISTING Float Switch MCC 01 Intrinsically safe barrier relay
required
LS-l036B 2nd Pump Start EXISTING Float Switch MCC 01 Intrinsically safe barrier relay
required
LS-l036C 3rd Pump Start EXISTING Float Switch , MCC 01 Intrinsically safe barrier relay
required
--
LS-l036D 4th Pump Start EXISTING Float Switch MCC 01 Intrinsically safe barrier relay
required
LS-l036E 5th Pump Start EXISTING Float Switch MCC 01 l~ntrinsicallY safe barrier relay
required
LSH-l036 Wet Well High Level EXISTING Float Switch MCC 01 l~ntrinsicaUY safe barrier relay
required
LSL-l036 Wet Well Low Level EXISTING Float Switch MCC 01 Intrinsically safe barrier relay
required
XS-l036A Pump #1 Run Status NEW Motor Starter N.D. Aux MCC Starter 01
Contact Cubicle
XS-l036B Pump #2 Run Status NEW Motor Starter N.D. Aux MCC Starter 01
Contact Cubicle
- --.-----
XS-l036C Pump #3 Run Status NEW Motor Starter N.D. Aux MCC Starter 01
Contact Cubicle
XS-l036D Pump #4 Run Status NEW Motor Starter N.C. Aux MCC Starter 01
Contact Cubicle
XS-l036E Pump #5 Run Status NEW Motor Starter N.D. Aux MCC Starter 01
Contact Cubicle
YS-l036A Pump #1 Overload DEMO Control Relay MCC Starter
Cubicle
YS-l036B Pump #2 Overload DEMO Control Relay MCC Starter
Cubicle
YS-l036C Pump #3 Overload DEMO Control Relay MCC Starter
, Cubicle I
, .- -----
I YS-l036D Pump #4 Overload DEMO Control Relay MCC Starter i
Cubicle
YS-l036E Pump #5 Overload DEMO Control Relay I MCC Starter I
I Cubicle
-_.----- i ,
Station Instrument Index Report
08/13/200105:43 PM
- .
-
CHEMICAL
TANK
WET WELL/
VALVE BOXES
WET WELL
VENT
-
MCC
BLDG
-
-
XFMR.
KOSAR STREET
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
<>
"
~
o
"
w
o
ID
'"
o
II II Ii II CORPIJS CHOS". IX. (J6I> 99'-'28'
II I [l PASO. TI (gIS) 534-9110
SAlT lAKE CI1Y, UT. (801) 261-14S!l
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1036 - ARCADIA
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
. .
I
r
ALARM
RELAY
CUBICLE
PUMP
CONTROL
PANEL
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAYS IN CUBICLE.
!i
<>
N
o
'"
~
o
"'
..,
o
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
1:111i11
CORPUS CHRISTI. 111. (361) 992-2284
[l PASO, Tll (915) 534-9'10
SAlT lAKE CITY, UT. (801) 261-14~
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1036 - ARCADIA
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
ENGINEERING CORPORATION
SCALE: N.T.S.
DR: DAILEY
_ r
1
1
J
RTU i
PANEL
1
L
1
1
L
I
L
I
L
L
I
L
PROJECT NO. 7100
-
<.:>
'"
<.:>
..;
<.:>
"
w
<.:>
'"
..,
<.:>
-
1:111i11
CORPUS CHRISTI, TX. (J61) 992-1284
[L PASO. TX (915) 5:l4-9110
SAlT lAKE CITY, UT. (801) 161-1455
ENGINEERING CORPORATION
JOB NO.: 1075
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
FLOAT SWITCH
TERMINAL BLOCKS
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1036 - ARCADIA
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1037
LEXINGTON
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
STATION NO. 1037
LEXINGTON
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
i ADDRESS: 5233 Lear Street
i'SUBDIVISION: Lexington Ctr. (SPID @ Crosstown
'Access Rd.)
r-----.---.-.-,..-~
. LATITUDE: N27044.097'
I LOCALE: West of SH 286 and SH 358
I'_""""_''''___"'''~______._mm....'..'..___________________m.n__n__...__________.......
I WASTEWATER PLANT: Greenwood
____...u,
,
I LONGITUDE: W97026.058'
iSERI/ICE-VOLTAG-E:-~2;;oi120V,3PH, 4W
i .....--~..-.-........-.-.~.-.....--..-.....
i FORCE MAIN: 6" CIP
...........____n_ "--1
~. ,
i PUMPS: (2) 7.5HP
INFLUENT PIPE(S): 8" VCP
-.-..........................-,
PHYSICAL DESCRIPTION:
The lift station is a wooden building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from one side.
Electrical service to the lift station is routed overhead from pole mounted transformers. The electric
meter is mounted on building exterior and main service disconnect is located in building interior.
Control equipment consists of individual starters, Pump Control Panel, RTU panel, and alarm relay
panel. All enclosures are mounted on the interior wall. All control devices and pump sequencing
controller are located in the pump control panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1300
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1037-1 Wetwell High Level
1037-2 Main Power Failure
1037-3 Motor #1 Failure
1037-4 Motor #2 Failure
1037-5 Drywell High Level
1037-6 Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
II
,I
~~,
STATION NO: 1037
LEXINGTON
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
JS-l037X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l037Y Pump Ctrt Pwr Failure NEW Control Relay (120 VAC Pump Control 01
coil) Panel
JS-l037Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l037A 1 st Pump Start EXISTING Mechanical Sensor Pump Control 01 Provide intrinsically safe barrier
Panel relay for future float switch
LS-1037B 2nd Pump Start EXISTING Mechanical Sensor Pump Control 01 Provide intrinsically safe barrier
Panel relay for future float switch
LSH-l037 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
- ---,_..._-_..,---~ .-.. ~----- ..- -_._-
LSHH-l037 Dry Well High level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-l037 Wet Well Low Level EXiSTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l037A Pump #1 Run Status NEW Motor Starter N.Q. Aux Pump Control 01
Contact Panel
XS-l037B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
.- Pump Control
YS-l037A Pump #1 Overtoad DEMO Control Relay
Panel
YS-l037B Pump #2 Overload DEMO Control Relay Pump Control
I Panel
Station Instrument Index Report
08113/2001 05:43 PM
'I r
11'
rr
~
DIRECTIONAL
ANTENNA
PUMP
BLDG.
~
.-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
,.
o
o
:>
w
o
~
n
o
I, II Ii II CORPUS CHRIST' lX. (361) 992-2'"
n PASO. IX (915) 534-9110
II I SALT l.Al([ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1037 - LEXINGTON
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
-
1
RTU
PANEL
PUMP CONTROL
PANEL
LIGHTING PANEL
L
1
1
I
L
1.
ALARM
RELAY
PANEL
1
1
L
EXISTING CONDUIT TO
DRY WELL HIGH LEVEL
FLOAT SWITCH
EXISTING CONDUIT TO
WET WELL HIGH LEVEL
FLOAT SWITCH
L
I
L
L
L
L
G DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\::../ ENCLOSURE RATING.
'-'
;t
o
,.;
o
'"
w
o
<-
..,
o
I. II Ii II Cl,/lPIIS CHROSTI. lX. (36') 99'-'23<
t I I [L PASO. Tx (915) S34-9110
SAlTlAKECITY,UT. (801)261-1"~
ENGINEERING CORPORATION
CITY or CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
I
l
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1037 - LEXINGTON
DATE: 03/2000 SHEET 2 OF 3
DR: DAILEY
-
MECHANICAL SWITCH
TERMINAL STRIP
-
-
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. TRACE OUT MECHANICAL LEVEL SWITCHES AND ROUTE STATUS
TO RTU.
11111i II CORPIJS CHIl1STI. TX. ('51) 992-2284
II I EL PASO. IX (gIS) S34-9'10
SALT lAKE CIlY, UT. (801) 261-1455
ENGINEERING CORPORATiON
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1037 - LEXINGTON
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
.
I
1"'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
~
...
~ STATION NO.
1038
SACKY
LIFT STATION
. p .
,.,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 038
SACKY
STATION TYPE: Lift Station: Wet well, Dry well, (3) vertical pumps
ADDRESS: 3200 Sacky Drive i LOCALE: East of Kostoryz Road
SUBDIVISION: Lynnwood PI. WASTEWATER PLANT: Oso
LATITUDE: N27043.519' LONGITUDE: W97024.872'
PUMPS: (3) 25HP SERVICE VOLTAGE: 480V, 3PH, 4W
INFLUENT PIPE(S): 18"VCP FORCE MAIN: 16"CIP
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is not surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from one side.
Electrical service to the lift station is routed from an overhead service pole from pole mounted
transformers. The electric meter is mounted on the service pole and main service disconnect is
located in building interior. Control equipment consists of an MCC wi starters, PLC based Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on the masonry wall.
All control devices and pump controller are located in the MCC. Conduits are rigid or flexible PVC.
Enclosures and conduits are in good condition.
Pumps are controlled from PLC control panel with a pressure transducer level sensor. Trouble alarms
are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2840
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1038-1 Drywell High Level
1038-2 Main Power Failure
1038-3 Motor #1 & #2 Failure
1038-4 Motor #3 Failure
08/13/01 5:12 PM
Station Data Sheet. doc
STATION NO: 1038
SACKY
STATION INSTRUMENT INDEX:
DIGITAL iNPUTS: 2
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
JS-l038X Main Power Failure NEW Phase Failure Monitor PLC Control Panel COMM Alarm status obtained from
Relay existing PlC via comm link
JS-l038Y Pump PLC Ctrl Pwr EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
Failure existing PLC via comm link
JS-l038Z RTU Ctrl Pwr Failure NEW 120V AC Digital input RTU Panel 01
LSH-l038 Wet Well High Level EXISTING Float Switch MCC 01 Intrinsically safe barrier relay
required
LSHH-l038 Dry Well High Level EXISTING Float Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
L T-l038 Wet Well Transmitter EXISTING Level Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
e--.. Valve Limit Switch PLC Control Panel COMM
YS-l038A Pump #1 Failure EXISTING Alarm status obtained from
existing PLC via comm link
YS-l038B Pump #2 Failure EXISTING Valve Limit Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-l038C Pump #3 Failure EXISTING Valve Limit Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-l038D Pump #1 Out of Service EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-l038E Pump #2 Out of Service EXISTING Control Relay PLC Control Panel COMM Alann status obtained from
existing PLC via comm link
YS-l038F Pump #3 Out of Service EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
Station Instrument Index Report
08/13/200105:43 PM
UTILITY CO.
METER
SERVICE
DIRECTIONAL
ANTENNA
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
~
5
:>
w
"
'"
..,
"
1==11i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI. TX. (J61) 992-2284
[L PASO. TIC (915) 534-9110
SAlT lAKE CITY, UT. (80!) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1038 - SACKY
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
--.......--
!I
11
TRANSFORMER
LIGHTiNG
PANEL
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
()
il:
o
N
o
"
~
o
'"
..,
o
II II Ii II CORPUS CHlOST'. ". (J6'1 "2-2,8<
[l PASO. TX (IllS) 534-9110
t I I SAlT lAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPuS CHRISTI
WASTEWATER DEPT.
PROuECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1038 - SACKY
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
_ r
1
1
1
RTU 1
PANEL
1
MCC
1
1
ALARM
RELAY 1
PANEL -
1
1
1
L
L
L
L
L
L
-
-
-
-
"
;t
o
..;
o
:>
w
o
'"
n
o
1==11i11
ENGINEERING CORPORATION
JOB NO.: 1075
ALLEN BRADLEY
SLC500 PLC
1. PROVIDE COMMUNICATIONS INTERFACE BETWEEN
EXISTING ALLEN BRADLEY SLC500 PLC AND NEW
RADIO TELEMETRY SYSTEM.
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, IX. (J61) 992-2284
[L PASO. IX (915) 5.14-9110
SAlT lAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1038 - SACKY
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1041
SCHANEN
LIFT STATION
. . 11
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1041
SCHANEN
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: 6102 Del Starr Drive LOCALE: East of Weber
SUBDIVISION: Schanen Estates WASTEWATER PLANT: Oso
LATITUDE: N27042.175' LONGITUDE: W97024.178'
PUMPS: (2) 7.5HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 12"VCP FORCE MAIN: 8"CIP
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station
has a service driveway. Lift pumps are located in the dry well and the top of the structure is flush with
grade. Vehicle access to the station is possible from two sides.
Electrical service to the lift station is routed from an overhead service pole. The electric meter and
service disconnect are located on the building exterior. Control equipment consists of a Switchboard,
Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on masonry wall
and on side of Switchboard. All control devices, except level control relays and pump sequencing
controller. are located in the Switchboard. Conduits are rigid or flexible PVC. Enclosures and conduits
are in good condition.
Pumps are controlled directly with mechanical level sensor interfaced through control relays and a
pump sequencing controller. Trouble alarms are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3220
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1041-1 Drywell High Level
1041-2 Main Power Failure
1041-3 Motor #1 Failure
1041-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
.
I
. .,"
r
STATION NO: 1041
SCHANEN
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
JS-l041A Pump #1 Power Failure DEMO Control Relay Exist RTU
JS-l041B Pump #2 Power Failure DEMO Control Relay Exist RTU
JS-l041X Main Power Failure NEW Phase Failure Monitor Switchboard Di
Relay
JS-l041Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-l041Z RTU CtrI Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l041A 1 st Pump Start EXISTING Mechanical Sensor Pump Control 01 Provide intrinsically safe barrier
Panel relay for future float switch
LS-l041B 2nd Pump Start EXISTING Mechanical Sensor Pump Control 01 Provide intrinsically safe barrier..--
Panel relay for future float switch
LSH-l041 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSHH-l041 Dry Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-l041 Wet Well Low level EXISTING Mechanical Sensor Pump Control 01 Provide intrinsically safe barrier
Panel relay for future float switch
XS-1041A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l041B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
-
YS-l041A Pump #1 Overfoad DEMO Control Relay Exist RTU
YS-l041B Pump #2 Overfoad DEMO Control Relay Exist RTU
Station Instrument Index Report
08/13/200105:43 PM
-
DIRECTIONAL
ANTENNA
PUMP BLDG.
UTILITY CO.
METER
DEL STARR DR.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
<>
'"
"!
o
~
w
o
.
o
1==11i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, IX. (J61) 992-2284
[l PASO, Tx (915) ~-gllO
SAlT lAK[ CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1041 - SCHANEN
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
----,------1"
~ ..-
r
ALARM
RELAY
PANEL
SWITCHBOARD
L
L
1
RTU
PANEL
1
PUMP 0
CONTROL 3
PANEL
1
1
LIGHTING
PANEL
PUMP
MOTOR
1
1
1
J
1
1
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
13\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\::...J ENCLOSURE RATING.
1
1
'-'
~
N
o
:>
w
o
..
o
1
1
11111i II CORPUS C><lOSIl. TX. (361) 99'-'20'
II I [l PASO. TI (915) 534-9110
SALT LAKE: CI1Y. UT. (801) 261-14~
ENGINEERING CORPORATION
CITY Of CORPUS CHRtSTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1041 - SCHANEN
DATE: 03/2000 SHEET 2 OF 3
1
DR: DAILEY
-
-
'-'
;t
o
.0
o
"
w
o
~
o
1==11i11
ENGINEERING CORPORATION
JOB NO.: 1075
.
I
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. TRACE OUT MECHANICAL LEVEL SWITCHES AND ROUTE STATUS
TO RTU.
.3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, lX, (361) 992-228.
[l PASO. !X (915) 5J4~9110
SAlllAKECITY,UT. (BOI) 261-1455
MICROWAVE COMMUNICAllON SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1041 - SCHANEN
DATE: 0.3/2000 SHEET.3 OF.3
SCALE: N.T.S.
DR: DAILEY
~ ...~
T"
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1042
THE LAKES
LIFT STATION
---, . I ,--
T
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 042
THE LAKES
I STATION TYPE: Lift Station: Wet well, (3) submersible pumps
. ADDRESS: 7335 Everhart ILOCALE~S;;-uth-~f'c-~;;;r-pas~-D;i~~----------"
! SUBDIVISION: Creekway and Sugar Ridge ! WASTEWAT-ER- PLAN-T:'O~~-- -- ................ ........ . ..u_
,
I PUMPS: (3) 20HP
I ~_."._-"._..,._-_._._-"~----------_.....-
1 LONGITUDE: W97024.471,
I ---.----.-.-.,.-,..----~---..-..-..-
I SERVICE VOLTAGE: 240/120V, 3PH, 4W
.............i
I LATITUDE: N27040.628'
_____i
INFLUENT PIPE(S): 12" VCP
PHYSICAL DESCRIPTION:
i FORCE MAIN: 10" PVC
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a cast-in-place concrete cap with no wall or fence. The station is located
adjacent to the street and does not have a service driveway or security fence. Vehicle access to the
station is possible from all sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on rack. All control
devices, including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3440
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1042-1 High Level
1042-2 Main Power Failure
1042-3 Motor #1 Failure
1042-4 Motor #2 & #3 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
I r
II
f!1
STATION NO: 1042
THE LAKES
STATION INSTRUMENT INDEX:
DIGiTAL INPUTS: 11
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
----..--- ~-~-- --
JS-l042X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l042Y Pump Ctrt Pwr Failure NEW Control Relay (120 V AC Pump Control 01
coil) Panel
JS-l042Z RTU Ctrt Pwr Failure NEW 120VAC Digital Input RTU Panei 01
LS-l042A 1st Pump Start EXISTING Float Switch New Junction Box 01 1~~trinsicaIlY safe barrier relay
required
LS-l042B 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-l042C 3rd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
--"------ 01 Intrinsically safe barrier relay
LSH-l042 Wet Well High Level EXISTING Float Switch New Junction Box
required
LSL-l042 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l042A Pump #1 Run Status NEW Motor Starter N.Q. Aux Pump Control 01
Contact Panel
XS-l042B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l042C Pump #3 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-l042A Pump #1 Overload DEMO Control Relay Pump Control
Panel
~---- - ._,--, ---.-
YS-l042B Pump #2 Overload DEMO Control Relay Pump Control
Panel
YS-l042C Pump #3 Overload DEMO Control Relay Pump Control
Panel
------ -- -.---
o
Station Instrument Index Report
08/13/2001 05:43 PM
WET WELL
ACCESS
EVERHART
ROAD
UTILITY CO. METER
AND SERVICE DISC.
DIRECTIONAL
ANTENNA
SERVICE
VALVE BOX
ACCESS
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
,.
q
;:;
"
w
o
N
V
o
I, II Ii II CORPIJS CHRISTI. TX. (361) 99'-22"
II I n PASO. IX (915) 534-9110
SAlT tAXt: CITY, UT. (B01) 261-14~
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
P~ECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1042 - THE LAKES
OATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
----rr-
I
m
DIRECTiONAL
ANTENNA
1
1
1
ALARM
RELAY
PANEL
1
1
PUMP CONTROL
PANEL 1
RTU
PANEL
1
1
WET WELL
ACCESS
J
J
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
~ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
AND
J
1
1
1
~
N
o
"
w
o
N
..
o
t
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
l
l
JOB NO.: 1075
SCALE: N.T.S..
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1042 - THE LAKES
DATE: 03/2000 SHEET 2 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
rL PASO. TX (915) 534-9110
Sot.lT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
<>
"
"
..;
"
'"
w
"
N
..
"
It II Ii II CORPUS CHRISTI. TX. (36') "'-'284
I tiEL PASO, Tx (915) 534-9110
SAlT tAKE CITY, UT. (801) 261-14~
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1042 - THE LAKES
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
-
-
-
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1044
EVERHART/STAPLES
LIFT STATION
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1044
EVERHART/STAPLES
STATION TYPE: Lift Station: Wet well, Dry well, (3) vertical pumps
ADDRESS: 780 Everhart Road LOCALE: East of South Staples on Everhart
SUBDIVISION: WASTEWATER PLANT: Oso
LATITUDE: N27043.469' LONGITUDE: W97022.643'
PUMPS: (2) 150HP, (1) 20HP SERVICE VOLTAGE: 480V, 3PH
INFLUENT PIPE(S): 27" VCP,36" VCP FORCE MAIN: 24"CIP
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway with no security fence. Lift pumps are located in the dry well and the
top of the structure is flush with grade. Vehicle access to the station is possible from two sides.
Electrical service to the lift station is routed overhead from pole mounted transformers. The electric
meter is mounted on service pole and main service disconnect is located in building interior. Control
equipment consists of an MCC wi soft starters, VFDs, Pump Control Panel and RTU panel. All
enclosures are mounted on the wall. All control devices and relays are located in the pump control
panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system. VFDs are the normal method of pump control with speeds set manually. NOTE: Pump
controls indicated are temporary and may differ from actual site conditions.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2740
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1044-1 Wetwell High Level
1044-2 Drywell High Level
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1044
EVERHART I STAPLES
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 12
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
-- ,--~
JS-l044X Main Power Failure NEW Phase Failure Monitor MCC Di
Retay
JS-l044Y Pump Girl Pwr Failure NEW Control Relay (120 VAC Pump Control 01
coil) Panel
JS-l044Z RTU Clrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l044A 1 st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-l0448 2nd Pump Start EXISTING Float Switch New JuncUon Box 01 Intrinsically safe barrier relay
required
LS-l044C 3rd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
Wet Well High Level ---
LSH-l044 EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSHH-1044 Dry Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-l044 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required I
XS-l044A Pump #1 Run Status NEW Motor Starter N.D. Aux MCC Starter 01
Contact Cubicle
XS-l044B Pump #2 Run Status NEW Motor Starter N.D. Aux MCC Starter 01
Contact Cubicle
XS-l044C Pump #3 Run Status NEW Motor Starter N.Q. Aux MCC Starter 01
Contact Cubicle ,
~_..- ~
Station Instrument Index Report
08/13/200105:43 PM
_ r
-
-
EVERHART
ROAD
DIRECTIONAL
ANTENNA
-
-
JEWISH COMMUNITY
CENTER PARKING LOT
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
;0
~
o
'"
w
o
..
..
o
11111i II CORPuS CHRISTI. TX. (361) 99'-"84
I tin PASO. IX (915) 534-9110
S41.T LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1044 - EVERHART/STAPLES
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
---,
I
T
1
TEMPORARY
RTU
PANEL
PUMP CONTROL
PANEL (PLC)
(ABANDONED)
1
1.
1
1
1
L
L
L
1
L
1
1
,
L
o
DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE TEMPORARY RTU
PANEL.
"
it
"
N
o
"
w
"
.
.
"
L
,
,
L
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100 t
ENGINEERING CORPORATION
CORPUS CHRISTI. lX. (J61) 992-2184
[l PASO. TX (915) 5J4-9110
SAlT LAJ([ CITY, Uf. (801) 261-H55
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1044 - EVERHART/STAPLES
DR: DAiLEY DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
- ,.
.
-
-
-
DRY WELL
VENT
TEMPORARY PUMP
CONTROL PANEL
-
-
-
STAIRS DOWN
TO DRY WELL
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. DEMO TEMPORARY PUMP CONTROL PANEL.
3. REROUTE WIRING FOR EXISTING FLOAT SWiTCHES.
'-'
'"
'-'
.-;
'-'
~
w
'-'
v
v
'-'
1==11i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (361) 992-2284
(l PASO, Tx (915) 534-9110
SAlTLAK(ClTY,UT, (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1044 - EVERHART/STAPLES
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
c-
.....
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
.-
,.....
.....
,.....
.....
STATION NO.
1046
,.....
US 77
LIFT STATION
- ~ -
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1046
usn
-
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 3386 County Road 52 LOCALE: U.S. 77 and County Road 52
SUBDIVISION: South of Calallen WASTEWATER PLANT: Allison
LATITUDE: N27050.839' LONGITUDE: W97038.088'
PUMPS: (2)3HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 6" FORCE MAIN:
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street
and has a service driveway and security fence. Vehicle access to the station is possible from one
side.
Electrical service is routed to the lift station from an overhead service pole. The electric meter and
service disconnect are located on a plywood rack. Control equipment consists of a Pump Control
Panel, RTU panel, and alarm relay panel. All enclosures are mounted on the rack. All control devices,
including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible
PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1230
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1046-1 High Level
1046-2 Main Power Failure
1046-3 Motor #1 Failure
1046-4 Motor #2 Failure
1046-5 Motor Control Power Failure
1046-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet. doc
-
-
STATION NO: 1046
usn
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-l046A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-l046B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-l046X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l046Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-l046Z RTU ClrI Pwr Failure NEW 120V AC Digital Input RTU Panel 01
LS-l046A 1 st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-l046B 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-l046 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-l046 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l046A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l046B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-1046A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-l046B Pump #2 Overload DEMO Control Relay Pump Control
Panel
L-~._ - ----~--_._---
Station Instrument Index Report
08/13/200105:43 PM
-
-
5 POINTS
STORAGE
ELECTRIC SERVICE
POLE
DIRECTIONAL
ANTENNA
-
COUNTY ROAD 52
ACCESS
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCiATED HARDWARE.
"
'"
"!
o
"
w
o
'"
.
o
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1046 - US 77
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
El PASO. lX (915) 534-9110
SAlT lAKE CITY, Uf. (801) 261-14~
ENGINEERING CORPORATION
DR: DAILEY
.
.
-
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1046 - US 77
DATE: 03/2000 SHEET 2 OF 3
ELECTRiC SERVICE
POLE
SERVICE
DISC.
UTILITY CO.
METER
RTU
PANEL
ALARM
RELAY
PANEL
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
;-;:\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
'U ENCLOSURE RATING.
<>
;0
o
'"
o
"
w
o
<0
V
o
II II Ii II CORPUS CHRISTI. IX. (,,,, 99'-"84
I tiEL PASO. IX (SUS) 5J4-!l110
SAlT I.Al([ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF" CORPuS CHRISTI
WASTEWATER OEPT.
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
.
. .~-
1
1
1
DIRECTIONAL
ANTENNA J
1
PUMP CONTROLl
PANEL
PLYWOOD
SUPPORT
PANEL
1
1
J
J
J
J
L
i
PROJECT NO. 7100
I
1
l
I
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"'
3:
o
..;
o
"
w
o
'"
..
o
I, II Ii II COIlf'\JS '"".." IX. (J6Il 99'-'28'
II I El PASO. IX (915) 534-9110
~TLAKEClTY.UT. (801)261-1455
ENGlNEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1046 - US 77
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1047
GREENFIELDS BY THE BAY
LIFT STATION
- I' r 1 --
r
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1047
GREEN FIELDS BY THE BAY
: STATION TYPE: Lift Station: Wet well, (2) submersible pumps
!~;;ESS: -;;2-~-~~~ad;;;~~-~;~;~=--=~=-~1~~C~~E:-_~a;~~~;;~~~i.:1~~~:&-~:~thof
: SUBDIVISION: Greenfield By the Bay ! WASTEWATER PLANT: Oso
. ,
. .
,...._.......____.__.....___.....__......_______.____....._____________~______.___...__ .....n. ......................__.___..__..._____.______________......_
'LATITUDE: N27040.184'
'LONGITUDE: W97021.00T
r.--.--....................--......---.................--....-----...----......------------. .. .................. . ... .........--.-
i SERVICE VOLTAGE: 480V, 3PH, 3W
: PUMPS: (2) 20HP
+..-.--...........-.............--.--....-.......--.....--.......-----------.-,-.......-
! INFLUENT PIPE(S):
FORCE MAIN: 6" PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lift station from a pad mounted transformer. The
electric meter and service disconnect are located on the masonry block wall. Control equipment
consists of a Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted
against the masonry wall on metal strut support brackets. All control devices, including pump motor
starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3110
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1047-1 High Level
1047-2 Main Power Failure
1047-3 Motor #1 Failure
1047-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet. doc
.. r
,1'
II'
STATION NO: 1047
GREEN FIELDS BY THE BAY
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FiELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
--- - --
JS-l047X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l047Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-l047Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l047A 1st Pump Start EXISTING Float Switch Exist Junction Box 01 1~~trinsicaIlY safe barrier relay
required
LS-l047B 2nd Pump Start EXISTING Float Switch Exist Junction Box 01 1~~trinsicaIlY safe barrier relay
required
LSH-l047 Wet Well High level EXISTiNG Float Switch Exist Junction Box 01 1~~trinsicaIlY safe barrier relay
required
-i.SC:l047 Wet Well Low Level EXISTiNG Float Switch ~-- Exist Junction Box 01 Intrinsically safe barrier relay
required
XS-l047A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l047B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
! YS-l047A Pump #1 Ovenoad DEMO Control Relay Pump Control
Panel
YS-l047B Pump #2 Overload DEMO Control Relay Pump Control
Panel
- -..-.
Station Instrument Index Report
08113/2001 05:43 PM
DIRECTIONAL
ANTENNA
TRANSFORMER
CANADIAN DR.
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
C>
"
"
o
"
w
"
~
~
"
It lllill CORPIJS DiRISTI. TX. ('OIl 99'-'28'
II I EL PASO, TX (915) 5J.4-9110
ENGINEERING CORPORATION SALT LAKE CITY, UT. (801) 261-145:1
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1047 - GREENFJELDS BY THE
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
BAY
-
,..'
--.-..~-~
L
L
ALARM 1
RELAY
PANEL
1
RTU
PANEL 1
1
1
1
1
1
1
AND 1
1
1
1
1
PROJECT NO. 7100
PUMP CONTROL
PANEL
TRANSFORMER
TERMINAL BOX
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
~ ASSOCiATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
'-'
;<
o
N
o
"
w
o
~
~
o
II II Ii II CORPUS CHRISTI. IX. (36') 99'-'28'
I t I [l PASO, IX (915) >>4-9110
ENGINEERING CORPORATION SAlT lAKE CITY. UT. (801) 261-1455
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1047 - GREENFIELDS BY THE
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
-
,.
-
1
BAY
-
-
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
..;
o
'"
w
o
~
~
o
11111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTl, lX. (J61) 992-2284
n PASO. IX (915) 534-9110
5.\1.1 tAKf: CIlY, UT. (801) 261-'4~
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1047 - GREEN FIELDS BY THE
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
BAY
JOB NO.: 1075
SCALE: N.T.S.
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
.-
STATION NO.
1048
-
WILLIAMS
LIFT STATION
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 048
WILLIAMS
-
STATION TYPE: Lift Station: Wet well, Dry well, (4) vertical pumps
ADDRESS: 6602 Williams Drive LOCALE: East of Daly
SUBDIVISION: Major WASTEWATER PLANT: Oso
LATITUDE: N27041.750' LONGITUDE: W97021.240'
PUMPS: (1) 60HP, (4) 500HP SERVICE VOLTAGE: 480V&4160V 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 36" DIP
PHYSICAL DESCRIPTION:
-
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway with no security fence. Lift pumps are located in the dry well and the
top of the structure is flush with grade. Vehicle access to the station is possible from three sides.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is mounted on building exterior and main service disconnect is located in building
interior. Control equipment consists of an MCC w/ starters, PLC based Pump Control Panel, RTU
panel, and alarm relay panel. All enclosures are mounted on the masonry wall. All control devices,
except ievel control relays, are located in the MCC. Conduits are rigid or flexible PVC. Enclosures
and conduits are in good condition.
Pumps are controlled by PLC control panel with a pressure transducer level sensor. Trouble alarms
are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 29r
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1048-1 Wetwell High Level
1048-2 Power Failure #1
1048-3 Power Failure #2
104B-4 Motor Failure #1A
1048-5 Motor #1 Failure
1048-6 Motor #2 Failure
1048-7 Motor #3 Failure
1048-8 Motor #4 Failure
1048-9 Bubbler Failure
1048-10 Drywell High Level
08113/0] 5:12 PM
Station Data Sheet.doc
!I
II
IT"
STATION NO: 1048
WILLIAMS
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 2
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
IT-l048A Lift Pump 1 A Motor EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
Current PLC via oomm link
IT-l 0488 Lift Pump 1 Motor Current EXISTING 4.20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via oomm link
IT-l048C Lift Pump 2 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via oomm link
IT-l 0480 Lift Pump 3 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-l048E Lift Pump 4 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
JS-l048X Main Power F ailura EXISTING Phase Failure Monitor PLC Control Panel COMM Alarm status obtained from
Relay existing PLC via comrn link
---- _.~
JS-l048Y Pump PLC Ctri Pwr EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
Failure existing PLC via comm link
JS-l048Z RTU Clrl Pwr Failure EXISTING 120V AC Digital Input RTU Panel 01
LSH-l048 Wet Well High Level EXISTING Float Switch PLC Control Panel Di Intrinsically safe barrier relay
required
LSHH-l048 Dry Well High Level EXISTING Float Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
LT-l048 Wet Well Level EXISTING Level Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
XS-1048A Lift Pump 1A H-O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Status obtained from exist Pump
Position Control PLC via comm link
~~-
XS-l048B LiftPump1 H-O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Status obtained from exist Pump
Position Control PLC via comm link
XS-l048C Lift Pump 2 H-O-A EXISTING H-O~A Aux Contact PLC Control Panel COMM Status obtained from exist Pump
Position Control PLC via comm link
XS-l048D LIft Pump 3 H-O-A EXiSTING H-O-A Aux Contact PLC Control Panel COMM Status obtained from exist Pump
Position Control PLC via comm link
XS-l048E Lift Pump 4 H-O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Status obtained from exist Pump
Position Control PLC via comm link
XS-1048F Lift Pump 1A Run Status EXISTING Motor Starter N.O. Aux PLC Control Panel COMM Run status obtained from exist
Contact Pump Control PLC via comm link
XS-l048G Lift Pump 1 Run Status EXISTING Motor Starter N.O. Aux PLC Control Panel COMM Run status obtained from exist
Contact Pump Control PLC via comm link
.- Motor Starter N.O. Aux PLC Control Panel COMM Run status obtained from exist
XS-l048H Lift Pump 2 Run Status EXISTING
Contact Pump Control PLC via comm link
XS-l0481 Lift Pump 3 Run Status EXISTING Motor Starter N.D. Aux PLC Control Panel COMM Run status obtained from exist
Contact Pump Control PLC via CQmm link
XS-l048J Lift Pump 4 Run Status EXISTING Motor Starter N.O. Aux PLC Control Panel COMM Run status obtained from exist
Contact Pump Control PLC via CQmm link
YS-1048A Lift Pump 1 Motor Fail EXISTING Motor Starter Aux Contact PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-l048B Lift Pump 1 A Motor Fail EXISTING Motor Starter Aux Contact PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-l048C Lift Pump 2 Motor Fail EXISTING Motor Starter Aux Contact PLC Control Panel COMM Alarm status obtained from
existing PLC via CQmm link
d~~
YS-l048D Lift Pump 3 Motor Fail EXISTING Motor Starter Aux Contact PLC Control Panel I COMM Alarm status obtained from
existing PLC via comm link
YS-l048E Lift Pump 4 Motor Fail EXISTING Motor Starter Aux Contact PLC Control Panei COMM Alarm status obtained from
existing PLC via comm link
- - ~ - ~- -
Station Instrument Index Report
08/13/2001 05:43 PM
-
DIRECTIONAL
ANTENNA
G REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
"
o
o
:>
w
o
'"
..
o
-
1:111i11
CITY OF CORPUS CHRISTI
wASTEWATER DEPT.
PROJECT NO. 7100
ENGINEERING CORPORATION
CORPUS CHRISTI, TX. (361) 992-2284
n PASO. Tll (915) 534-9110
SAlT LAKE ClTY,UT. (801)161-1455
MICROWAVE COMMUNlCA1l0N SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1048 - WilLIAMS
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
I
11
11"
RTU
PANEL
JUNCTION BOX
1
LIGHTING PANEL 1
1
1
1
l.
J
1
ANNUNCIATOR
PANEL
PUMP CONTROL
PANEL (PLC)
1
1
L
1
1
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
L
"
~
o
N
o
2
w
o
.,
~
o
L
II II Ii II CORPUS CHRISTl. IX. ("'J 99'-""
t t I [L PASO. TI (915) 534-9110
SALTLAKECfTY,UT. (1101)261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHR~n
WASTEWATER DEPT.
PROJECT NO. 7100
L
1
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1048 - WilLIAMS
DATE: 03/2000 SHEET 2 OF 3
DR: DAILEY
- -
-
-
'-'
~
.-;
o
"
w
o
m
~
o
~
1==11i11
ENGINEERING CORPORATION
JOB NO.: 1075
1. PROVIDE COMMUNICATIONS INTERFACE BETWEEN
EXISTING MODICON QUANTUM PLC AND NEW RADIO
TELEMETRY SYSTEM
crTY Of CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (J61) 992-2284
EL PASO. III (915) 5J4-9110
SAlT lAKE CITY, UT. (801) 261-'''55
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1048 - WILLIAMS
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
STATION NO.
~.
1049
WOOLDRIDGE
LIFT STATION
- . r I
T'"
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1049
WOOLDRIDGE
-
STATION TYPE: Lift Station: Wet well, Dry well, (4) vertical pumps
ADDRESS: 6610 Wooldridge Road LOCALE: East of Airline
SUBDIVISION: Major WASTEWATER PLANT: Oso
LATITUDE: N27041.003' LONGITUDE: W97021.748'
PUMPS: (1) 75HP, (3) 250HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): (2) 36" VCP FORCE MAIN: 30"DIP
....
-
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway with no security fence. Lift pumps are located in the dry well and the
top of the structure is flush with grade. Vehicle access to the station is possible from three sides.
Electrical service to the lift station is routed underground from two pad mounted transformers. The
electric meter is mounted on building exterior and main service disconnect is located in building
interior. Control equipment consists of two MCCs wi starters, Bubbler based Pump Control Panel,
RTU panel, and alarm relay panel. All enclosures are mounted on the masonry wall. All control
devices, except level control relays and pump sequencing controller are located in the MCC. Conduits
are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with a bubbler level sensor interfaced through control relays and a pump
sequencing controller. Trouble alarms are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 309"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1049-1 MCC #2 Power Failure
1049-2 MCC #1 Power Failure
1049-3 Motor Failure LP-1A
1049-4 Pump Failure #1A
1049-5 Motor Failure LP-1
1049-6 Pump Failure #1
1049-7 Motor Failure LP-2
1049-8 Pump Failure #2
1049-9 Motor Failure LP-3
1049-10 Wetwell High Level
1049-11 Drywell High Level
1049-12 Bubbler Failure
08/13/01 5:12 PM
Station Data Sheet.doc
. r
II'
1T
STATION NO: 1049
WOOLDRIDGE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 14
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
JS-l049X MCC-l& MCC-2 Power NEW Phase Failure Monitor MCC 01
Failure Relay
JS-l049Y Pump Ctrl Pwr Failure NEW Control Relay RTU 01
JS-l049Z RTU CtrI Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l049A 1st Pump Start EXISTING Bubbler Controls Pump Control 01
Panel
LS-l0498 2nd Pump Start EXISTING Bubbler Controls Pump Control 01
Panel
LS-l049C 3rd Pump Start EXISTING Bubbler Controls Pump Control 01
Panel
- -~.
LS-l049D 4th Pump Start EXISTING Bubbler Controls Pump Control 01
Panel
LSH-l049 Wet Well High Level EXISTING Float Switch MCC 01 Intrinsically safe barrier relay
required
LSHH-l049 Dry Well High level EXISTING Float Switch MCC 01 Intrinsically safe barrier relay
required
LSL-l049 Wet Well Low Level EXISTING Bubbler Controls Pump Control 01
Panel
XS-l049A lift Pump 1 Run Status NEW Motor Starter N.O. Aux MCC 01
Contact
, XS-l049B lift Pump 2 Run Status NEW Motor Starter N.D. Aux MCC 01
, Contact
~ --~-_.~ - --.
XS-l049C Lift Pump 3 Run Status NEW Motor Starter N.O. Aux MCC 01
Contact
XS-l049D Lift Pump 4 Run Status NEW Motor Starter N.O. Aux MCC 01
Contact
, YS-l049A Motor Lp.1A Failure DEMO Control Relay Alarm Relay Panel Annun. 1-1
YS-l049B Pump LP-1A Failure DEMO Control Relay :Alarm Relay Panel Annun. 1-2
YS-l049C Motor LP-1 Failure DEMO Control Relay Alarm Relay Panel Annun. 1-3
YS-l049D Pump Lp.1 Failure DEMO Control Relay Alarm Relay Panel Annun. 1-4 I
YS-l049E Motor LP-2 Failure DEMO Control Relay Alarm Relay Panel Annun.2-1
YS-l049F Pump LP-2 Failure DEMO Control Relay Alarm Relay Panel Annun.2-2
YS-1049G Motor LP-3 Failure DEMO Control Relay Alarm Relay Panel Annun.2-3
YS-l049H Pump LP-3 Failure DEMO Control Relay Alarm Relay Panel Annun.2-4
YS-l049J Pump LP-4 Failure DEMO Control Relay Alarm Relay Panel Annun.3-1
YS-l049K Motor LP-4 Failure DEMO Control Relay Alarm Relay Panel Annun.3-2
--
YS-l049L Wet Well High Level DEMO Control Relay Alarm Relay Panel Annun.3-3
YS-l049M Bubbler Failure DEMO Control Relay Alarm Relay Panel Annun.3-4
I ----- - ._---~~-- -- ----
Station Instrument Index Report
08/13/2001 05:43 PM
-
-
DIRECTIONAL
ANTENNA
WOOLDRIDGE RD.
-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
'"
"
o
"
w
o
0>
.
o
1=111i11
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTl. IX. (361) 992-2284
[L PASO, ,. (gIS) 5~-g110
SAlT tAJ(ECITY,UT. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1049 - WOOLDRIDGE
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
JOB NO.: 1075
SCALE: N.T.S.
I
II'
r
,
11'
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1049 - WOOLDRIDGE
DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
JUNCTION BOX
LIGHTING
PANEL
CIRCUIT
BREAKER
o DISCONNECT
o DISCONNECT
POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
ALARM WIRING AND REMOVE ALARM RELAY PANEL.
"
~
....
o
"
w
"
'"
~
o
II II Ii II CORPUS CHRISTI. TX. (J"I99'-"84
II I El PASO. IX (915) 534-9110
SALT lAKE CITY, UT. (801) 261-1455
ENGINEERINC CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
-
-
1
ANNUNCIATOR L
PANEL
1
RTU
PANEL
1
L
1
L
L
L
ALARM
RELAY
PANEL
L
l
I
L
,
I
PROJECT NO. 7100
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
-
STATION NO.
1050
COLE PARK
LIFT STATION
. ... If r ~ ,,---"-- rT
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 050
COLE PARK
-
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
..nn
ADDRESS: 1500 Ocean Drive LOCALE: East of Shoreline Blvd. at Cole Park
SUBDIVISION: Cole Park WASTEWATER PLANT: Broadway
LATITUDE: N2?D46.448' LONGITUDE: W9?D23.424'
PUMPS: (2)5HP SERVICE VOLTAGE: 240V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 4"CIP
-.
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap that is flush with grade. The station is accessed
through Cole park and is surrounded by a chain link security fence. The Pump Control Panel is
housed in expanded metal cage type security enclosure mounted on the amphitheatre masonry wall.
Vehicle access to the station is possible from two sides.
Electrical power is obtained from the amphitheatre electrical panel through a phase adder. Control
equipment consists of a Pump Control Panel, RTU panel, and alarm relay panel. All control devices,
including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible
PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2130
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1050-1 High Level
1050-2 Main Power Failure
1050-3 Motor #1 Failure
1050-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1050
COLE PARK
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
-. .-
JS-l050A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-l050B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-l050X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l050Y Pump Ctrt Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-l050Z RTU Ctrl Pwr Failure NEW 120V AC Digital I nput RTU Panel 01
, LS-l050A 1 st Pump Start EXiSTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
, required
- 2nd Pump Start EXISTING Float Switch New Junction Box Intrinsically safe barrier relay
LS-l050B 01
required
LSH-l050 Wet Well Hi9h Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-l050 Wet Well Low level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
requIred
XS-l050A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l050B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-l050A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-l050B Pump #2 Overload DEMO Control Relay Pump Control
Panel _-.J
.--.-" --
Station Instrument Index Report
08/13/2001 05:43 PM
.
I
T'1
EXPANDED
METAL CAGE
DIRECTiONAL
ANTENNA
AMPHITHEATER
-
-
-
WET WELL
COLE PARK
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
<>
;0
"l
o
:>
w
o
o
'"
o
11111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1050 - COLE PARK
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, lX. (361) 992-2284
[l PASO, TX (915) 534-9110
ENGINEERING CORPORATION SAlT I.Al(( CITY, UT. (801) 261-14~
DR: DAILEY
.
I.
,.,
PUMP CONTROL
PANEL
(2)
o
o
~
"
N
o
"
w
"
o
'"
o
oi
\ ,H
\\ ,t
l ,l
t' ..
-/_' _ .fl.
Pi d tt
0HffH
tlNiN,
I"~ II I II
I II tI"l
flllll..
WN.II
1I1!!,H
II "iN.
I tI I I"
""',,,,
NN.'t'/1
," ".,
, '....'''1
"WII'i.
N, I Ii"'.
.'V..tV
!)'{ttt,.t, '
EXPANDED METAL CAGE
DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRiNG AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1050 - COLE PARK
DATE: 03/2000 SHEET 2 OF 3
1:111i11
CORPUS CHRISTl, TX. (J61) 992-2284
0. PASO, Tll (915) ~-9110
SAlT lAK[ CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
DR: DAILEY
1
1
1
1
RTU 1
PANEL
1
ALARM 1
RELAY
PANEL
1
1
1
1
1
1
1
l
L
L
~
FLOAT SWITCH
TERMINAL STRIP
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
'"
c
..;
o
"
w
c
c
'"
o
1::11i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1050 - COLE PARK
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTl, lX. (361) 992-2284
tL PASO, 1X (915) 534-9110
So\LT L.AJ([ CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
.
I
T
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
STATION NO.
1051
PEARY PLACE
LIFT STATION
. ,.. . I -..
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 051
PEARY PLACE
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: Thompson Road LOCALE: East of Lexington Road i
SUBDIVISION: Peary Place WASTEWATER PLANT: Oso
LATITUDE: N2?D41.116' LONGITUDE: W97020.056'
PUMPS: (2) 10/7.5HP (2-SPEED) SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 15"VCP FORCE MAIN: 10"CIP
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from two sides.
Electrical service to the lift station is routed overhead from pole mounted transformers. The electric
meter is mounted on building exterior and main service disconnect is located in building interior.
Control equipment consists of a Switchboard wi starters, Pump Control Panel, RTU panel, and alarm
relay panel. All enclosures are mounted on the masonry wall. All control devices, except level control
relays and pump sequencing controller are located in the Switchboard. Conduits are rigid or flexible
PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2980
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1051-1 Wetwell High Level
1051-2 Main Power Failure
1051-3 Motor #1 Failure
1051-4 Motor #2 Failure
1051-5 Drywell High Level
1051-6 Motor Control Power Failure
08/13/01 5: 12 PM
Station Data Sheet.doc
STATION NO: 1051
PEARY PLACE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
- .._~
JS-1051A Pump #1 Power Failure DEMO Control Relay Switchboard
JS-l051B Pump #2 Power Failure DEMO Control Relay Switchboard
JS-l051X Main Power Failure EXISTING Phase Failure Monitor Switchboard 01
Relay
JS-l051Y Pump Gtrl Pwr Failure NEW Control Relay (120 V AC Switchboard 01
coil)
JS-l051Z RTU Ctrl Pwr Failure NEW 120VAC Digitallnpul RTU Panel 01
LS-l051A 1 st Pump Start EXISTING Mechanical Sensor Switchboard 01 Provide intrinsically safe barrier
relay for future float switch
'~..n_
LS-l051B 2nd Pump Start EXISTING Mechanical Sensor Switchboard 01 Provide intrinsically safe barrier
relay for future float switch
LSH-l051 Wet Well High Level EXISTING Float Switch Switchboard 01 1~~trinsicaItY safe barrier relay
required
LSHH-l051 Dry Well High Level EXISTING Float Switch Switchboard 01 Intrinsically safe barrier relay
required
LSL-l051 Wet Well Low Level EXISTING Mechanical Sensor Switchboard 01 Provide intrinsically safe barrier
relay for future float switch
XS-l051A Pump #1 Run Status NEW Motor Starter N.D. Aux Switchboard 01
Contact
XS-l051B Pump #2 Run Status NEW Motor Starter N.D. Aux Switchboard 01
Contact
----
YS-1051A Pump #1 Overload DEMO Control Relay Switchboard
YS-l051B Pump #2 Overload DEMO Control Relay Switchboard
..--- ----~
Station Instrument Index Report
08/13/200105:43 PM
.
I
.
r
DIRECTIONAL
ANTENNA
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
<.:>
,.
"!
o
:>
w
"
~
o
1==11i11
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
ENGINEERING CORPORATION
CORPUS CHRISTI, TX. (361) 992-2284
[L PASO, TX (915) ~-gIlO
SAlT lAKE enY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SVSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1051 - PEARY PLACE
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
- ..
-
.
PUMP CONTROL
PANEL
J
RTU
PANEL
1
1
ALARM
RELAY
PANEL
1
1
1
SWITCHBOARD
l.
SERVICE DISC. l.
l.
l
1
l
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
L
L
"
~
N
o
"
w
o
'"
o
L
II II Ii II CORPUS '""S". TX. (36'> 99,.,'"
II I [L PASO. tx (915) 5J.4-9110
SAlT l.AI([ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1051 - PEARY PLACE
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
-
<:J
"
o
..;
o
"
w
o
~
o
1:111i11
ENGINEERING CORPORATION
JOB NO.: 1075
1. TRACE OUT MECHANICAL LEVEL SWITCHES AND
ROUTE STATUS TO RTU.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPuS CHRISTl, TX. (361) 992-2284
(t PASO, IX (915) 53<4-9110
SAlT lAKE CITY,UT. (6(11)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1051 - PEARY PLACE
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
~
STATION NO.
1052
STATION NO.5
LIFT STATION
. ~ I
T"
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 052
STATION NO.5
STATION TYPE: Lift Station: Wet well, (3) submersible pumps
ADDRESS: 6528 S. Staples LOCALE: South Staples and Saratoga
SUBDIVISION: Major WASTEWATER PLANT: Oso
LATITUDE: N27041.050' LONGITUDE: W97023.049'
PUMPS: (3) 45HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN:
PHYSICAL DESCRIPTION:
The lift station is a prefabricated metal building housing the electrical equipment. The station is
accessed from a service driveway and is not surrounded by a chain link security fence. Vehicle
access to the station is possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is located on building exterior. Control equipment consists of a Motor Control Center
(MCC), PLC based Pump Control Panel, RTU panel, and alarm relay panel. RTU panel is mounted on
interior wall. Pump Control Panel and alarm relay panel are mounted on wall. Conduits are rigid or
flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled by PLC control panel with a pressure transducer level sensor. Trouble alarms
are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 320"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1052-1 High Level
1052-2 Main Power Failure
1052-3 Motor #2 Failure
1052-4 Motor #1 & #3 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- ~
STATION NO: 1052
STATION NO.5
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 2
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
-
FT-l055 Effluent Flow FUTURE Flow Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
-- EXISTING 4-20mA Current Sensor
IT-l055A Lift Pump 1 Motor Current PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-l055B Lift Pump 2 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-1055C Lift Pump 3 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
JS-1055X Main Power Failure EXISTING Phase Failure Monitor PLC Control Panel COMM Alarm status obtained from
Relay existing PLC via comm link
JS-1055Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LSH-l055 Wet Well High Level EXISTING Float Switch PLC Control Panel 01 Intrinsically safe barrier relay
required
L T-l055 Wet Well Level EXISTING Level Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
XS-l055A Lift Pump 1 H-O-A EXISTING H-Q-A Aux Contact PlC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link
XS-10558 Lift Pump 2 H-Q-A EXISTING H-O-A Aux Contact PLC Control Panel COMM AJann status obtained from
Position existing PLC via comm link
XS-l055C Lift Pump 3 H-O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link
YS-l055A Lift Pump 1 Motor Fail EXISTING Valve Limit Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
----... PLC Control Panel
YS-l055C Lift Pump 2 Motor Fail EXISTING Valve Limit Switch COMM Alarm status obtained from
existing PLC via comm link
YS-l055E Lift Pump 3 Motor Fail EXISTING Valve Limit Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
~ - -- -~
Station Instrument Index Report
08/13/200105:43 PM
. ...
11
r"l
CHEMICAL
TANK
ELECTRICAL
BLDG.
DIRECTIONAL
ANTENNA
-
-
-
1
-
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
"
Q
o
'"
w
o
N
on
Q
1=111i11
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI. Tx. (J61) 992-2284
[L PASO. IX (915) 534-9110
SAlT lAKE CITY. U1. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1052 - STATION #5
DATE: 03/2000 SHEET 1 OF 2
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
J
MOTOR CONTROL
CENTER
RTU PANEL
1.
1
1.
1.
PUMP
CONTROL
PANEL (PLC)
1.
1
1
1.
L
1
1
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\J ASSOCIATED UNISTRUT SUPPORTS.
;-;\ PROVIDE COMMUNICATIONS INTERFACE BETWEEN EXISTING MODICON QUANTUM
~ PLC AND NEW RADIO TELEMETRY SYSTEM
I
L
\1
o
N
o
:>
w
o
N
on
o
1
II lllill CORPUS "OSll.1'. 1'61> 99'-2284
I tiEL PASO. TX (915) 534-9110
ENGINEERING CORPORATION SALT lAKE CITY, UT. (801) 261-1455
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1052 - STATION #5
DATE: 03/2000 SHEET 2 OF 2
DR: DAILEY
I
11
111
Wastewater Department
~ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1053
COUNTRY CLUB ESTATES
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1053
COUNTRY CLUB ESTATES
-
STATION TYPE: Lift Station: Wet well, Dry well, (3) vertical pumps
ADDRESS: 6300 Everhart Road LOCALE: North of Saratoga
SUBDIVISION: Country Club Estates WASTEWATER PLANT: Oso
LATITUDE: N27041.652' LONGITUDE: W97023.805'
PUMPS: (3) 75HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 24" DIP
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway with no security fence. Lift pumps are located in the dry well and the
top of the structure is flush with grade. Vehicle access to the station is possible from two sides.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is mounted on building exterior and main service disconnect is located in building
interior. Control equipment consists of an MCC w/ soft starters, PLC based Pump Control Panel, RTU
panel, and alarm relay panel. All enclosures are mounted on the masonry wall. All control devices,
except level control relays and pump sequencing controller are located in the MCC. Conduits are rigid
or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled by PLC control panel with a pressure transducer level sensor. Trouble alarms
are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3230
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1053-1 Main Power Failure
1053-2 Motor Control Power Failure
1053-3 Bubbler Failure
1053-4 Wetwell High Level
1053-5 Drywell High Level
1053-6 Motor #1 Failure
1053-7 Motor #2 Failure
1053-8 Motor #3 Failure
08/13/01 5:12 PM
Station Data Sheet. doc
STATION NO: 1053
COUNTRY CLUB ESTATES
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 2
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
,-------- PLC Control Panel COMM
IT-l053A Lift Pump 1 Motor Current EXISTING 4-20mA Current Sensor Analog data obtained from exist
PLC via comm link
IT-l053B Lift Pump 2 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-l053C Lift Pump 3 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained trom exist
PLC via comm link
JS-l053 Control Power Failure EXISTING Phase Failure Monitor PLC Control Panel COMM Alarm status obtained from
Relay existing PLC via comm link
, JS-1053X Main Power Failure EXISTING Phase Failure Monitor PLC Control Panel COMM Alarm status obtained from
Relay existing PLC via comm link
JS-1053Y Pump PLC Ct~ Pwr EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
Failure existing PLC via comm link
- ----- - .-
JS-l053Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LSH-l053 Wet Well High Level EXISTING Float Switch RTU Panel 01 Intrinsically safe barrier relay
required
LSHH-l053 Dry Well High Level EXISTING Float Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
L T-l053 Wet Well Level EXISTING level Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
XS-l053A LiftPump1 H-O-A EXISTING H-Q-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link
XS-l053B Lift Pump 2 H-O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link
XS-l053C Lift Pump 3 H-O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link
XS-l053D Lift Pump 1 Run Status EXISTING Motor Starter Aux Contact PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
XS-l053E Lift Pump 2 Run Status EXISTING Motor Starter Aux Contact PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
XS-l053F Lift Pump 3 Run Status EXISTING Molor Starter Aux Contact PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-l053A Lift Pump 1 Starter EXISTING Motor Starter Fail Contact PLC Control Panel COMM Alarm status obtained from
Failure (Fault) existing PLC via comm link
YS-l053B Lift Pump 2 Starter EXISTING Motor Starter Fail Contact PLC Control Panel COMM Alarm status obtained from
Failure (Fault) existing PLC via comm link
YS-l053C Lift Pump 3 Starter EXISTING Motor Starter Fail Contact PLC Control Panel COMM Alarm status obtained from
Failure (Fault) , existing PLC via comm link
--. --. I
Station Instrument Index Report
08/13/200105:43 PM
I
II
!r1
DiRECTIONAL
ANTENNA
(ON OUTSIDE OF
BLDG. WALL)
EVERHART RD.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
;0
o
o
"
w
o
..,
'"
o
II II Ii II CORP\JS CHRISTI. TX. (361) 99'-"84
II I (L PASO. IX (915) 534-9110
SALT WE CI1Y. Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1053 - COUNTRY CLUB ESTATES
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
--,
~
II
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1053 - COUNTRY CLUB ESTATES
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
ALARM
RELAY
PANEL
LIGHTING
PANEL
TRANSFORMER
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
(I) DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
~
o
N
o
"
w
o
n
'"
o
II II Ii II CORPUS CHRIST'. IX. (61) 992-228'
It I I n PASO. 11 (915) 534-9110
SAlT LAK[CJTY.UT. (801)261-14~
ENGINEERING CORPORATION
ell)' or CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
1
1
1
1
1
PUMP
CONTROL 1
PANEL
1
1
1
1
1
UPS
L
L
L
L
PROJECT NO. 7100
L
L
"
'"
o
.;
o
"
w
o
n
'"
o
1:111i11
ENGINEERING CORPORATiON
JOB NO.: 1075
_ r
1. PROVIDE COMMUNICATIONS INTERFACE BETWEEN EXISTING
MODICON QUANTUM PLC AND NEW RADIO TELEMETRY SYSTEM.
erTY Of CORPUS CHRISTI
WASTEWATER OEPT.
PROUECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1053 - COUNTRY CLUB ESTATES
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, IX. (361) 992-2284
El PASO, TX (915) 5J4-9110
SAlT 1..Al([ CITY, UT. (801) 261-1455
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1054
-'
BUCKINGHAM
LIFT STATION
.. r 11 r" -".. ,
rr'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1054
BUCKINGHAM
~
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 7501 South Staples LOCALE: Staples and Yorktown
SUBDIVISION: Buckingham Estates WASTEWATER PLANT: Oso
LATITUDE: N27037.988' LONGITUDE: W97"23.785'
PUMPS: (2) 20HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN:
-
-
-
PHYSICAL DESCRIPTION:
-
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and has a service driveway and security fence.
Vehicle access to the station is possible from two sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3450
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1054-1 High Level
1054-2 Main Power Failure
1054-3 Motor #1 Failure
1054-4 Motor #2 Failure
1054-5 Motor Control Power Failure
1054-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- ..
-
STATION NO: 1054
BUCKINGHAM
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
--_.-- -~- .~--- I
JS-l054X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l054Y Pump Ctrl Pwr Failure NEW Control Relay (24 VAC Pump Control 01 !
coil) Panel
JS-l054Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l054A 1 st Pump Start EXISTING Float Switch New Junction Box 01 1~~trinsicaIlY safe barrier relay !
required
LS-l054B 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-l054 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
~. --_.--
LSL-l054 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l054A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
XS-l054B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
YS-l054A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-l054B Pump #2 Overload DEMO Control Relay Pump Control
Panel
-- ------ -
Station Instrument Index Report
08/13/200105:43 PM
- ,..
-
.0.
ELECTRIC SERVICE
POLE
DIRECTIONAL
ANTENNA
-
-
-
-
-
UTILITY CO.
METER AND
SERVICE DISC.
YORKTOWN BLVD.
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
o
o
"
w
o
~
'"
o
II II Ii II COOI'US "''''''. lX. ('OIl 992-228.
II I (l PASO, IX (91!1) ~-9110
SAlT UJ([ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROU[CT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1054 - BUCKINGHAM
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
.
II
1"'1
WET WELL
VENT
J
1
ALARM RELAY 1
PANEL
1
1
1
1
1
i
1
1
L
AND
TRANSFORMER
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
;-:;\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
L
~
...
o
:>
~
o
~
'"
o
L
11111i II CORPUS CHR'STO. n. (36') 99'-"8<
t I I EL PASO. lX (915) 534-9110
ENGINEERING CORPORATION SAlT l.JJ(E CITY, UT. (801) 261-1455
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1054 - BUCKINGHAM
DATE: 03/2000 SHEET 2 OF 3
DR: DAILEY
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
;t
o
ri
o
"
w
o
..
"'
o
1::11i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
ENGINEERING CORPORATION
CORPUS CHRISTI, TX. (J61) 992-2284
EL PASO, TX (915) >>4-9110
SAlT lAKE" CITY, lIT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1054 - BUCKINGHAM
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
- ,.
-
Wastewater Department
~ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1055
KOSTORYZ
LIFT STATION
"u _. r..... , .~..,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 055
KOSTORYZ
STATION TYPE: Lift Station: Wet well, (3) submersible pumps
ADDRESS: 6261 Kostoryz LOCALE: North of Saratoga
SUBDIVISION: Crestmont #6 WASTEWATER PLANT: Greenwood
LATITUDE: N27042.598' LONGITUDE: W97025.501'
PUMPS: (3) 20HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN:
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the electrical equipment. The station is accessed
from a service driveway with a security fence. Lift pumps are located in the wet well and the top of the
structure is flush with grade. Vehicle access to the station is possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is mounted on building exterior and main service disconnect is located in building
interior. Control equipment consists of an MCC wi soft starters, PLC based Pump Control Panel, RTU
panel, and alarm relay panel. All enclosures are mounted on the masonry wall. All control devices,
except level control relays and pump sequencing controller are located in the MCC. Conduits are rigid
or flexible PVC. Pumps are controlled by a PLC control panel with a pressure transducer level sensor.
Trouble alarms are currently reported through the UHF radio system.
NOTE: Lift station currently under construction. Actual site conditions may vary.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 20
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1055-1 High Level
1055-2 Main Power Failure
1055-3 Motor #1 Failure
1055-4 Motor #2 & #3 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
-
STATION NO: 1055
KOSTORYZ
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 2
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
FT-1055 Effluent Flow FUTURE Flow Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-1055A Lift Pump 1 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-1055B Lift Pump 2 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-1055C Lift Pump 3 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
I PLC via comm link
i
JS-1055X Main Power Failure EXISTING Phase Failure Monitor PLC Control Panel COMM Alarm status obtained from
Relay existing PLC via comm link
JS-1055Z RTU Ctrl Pwr Failure NEW 120VAC Digilallnput RTU Panel DI
---- -._".0 .---
LSH-1055 Wet Well High Level EXISTING Float Switch PLC Control Panel DI Intrinsically safe barrier relay
required
L T-1055 Wet Well Level EXISTING Level Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
XS-1055A Lift Pump 1 H-O-A EXISTING H-Q-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link
XS-1055B Lift Pump 2 H-O-A EXISTING H-Q-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link !
XS-1055C Lift Pump 3 H-O-A EXISTING H-Q-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position existing PLC via comm link
YS-1055A Lift Pump 1 Motor Fail EXISTING Valve Limit Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-1055C Lift Pump 2 Motor Fail EXISTING Valve Limit Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
YS-1055E Lift Pump 3 Motor Fail EXISTING Valve Limit Switch PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
_u_ -------.---
Station Instrument Index Report
08/13/2001 05:43 PM
- ...
-
-
;.
-
PICTURE NOT AVAILABLE
UFT STATION UNDER CONSTRUCTION
C>
;t
o
o
"
w
o
"'
"'
o
II II Ii II co."" C"'''''. ". (361) 992-228'
II I [L PASO, lX (915) 534-9110
SALllAJ(ECITY,Ul. (801)261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
PROJECT NO. 7100
WASTEWATER DEPT.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1055 - KOSTORYZ
I DATE: 03/2000 I SHEET 1 OF 1
JOB NO.: 1075
1 SCALE: NT.S.
T DR: DAILEY
.
I.
~
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1056
PELICAN BAY
LIFT STATION
. ~ !I
1"'1
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1056
PELICAN BAY
~
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 1418 Ennis Joslin Road LOCALE: North of McArdle
SUBDIVISION: Pelican Bay WASTEWATER-PLANT: Oso
LATITUDE: N27041.925' LONGITUDE: W97020.004'
PUMPS: (2)2HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 8"VCP FORCE MAIN: 4"PVC
~
~
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and has a service driveway and no security
fence. Vehicle access to the station is possible from two sides.
Electrical service is routed to the lift station from an overhead service pole. The electric meter and
service disconnect are located on the service pole. Control equipment consists of a Pump Control
Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry wall on
metal strut support brackets. All control devices, including pump motor starters, are located in the
Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 290"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1056-1 High Level
1056-2 Main Power Failure
1056-3 Motor #1 Failure
1056-4 Motor #2 Failure
1056-5 Motor Control Power Failure
1056-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1056
PELICAN SAY
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TiE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
-jS-1056A I -. - -~
Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-1056B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1056X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1056Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1056Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1056A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
.~_._.-
LS-1056B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1056 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1056 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1056A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1056B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1056A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1056B Pump #2 Overload DEMO Control Relay Pump Control
Panel
Station Instrument Index Report
08/13/200105:43 PM
ELECTRIC
DIRECTIONAL
ANTENNA
~
~
"
~
~
UTI L1TY CO.
METER AND
SERVICE DISC.
ENNIS JOSLIN
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
o
:>
w
o
'"
"'
o
1&111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1056 - PELICAN BAY
DATE; 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, lX. (J61) 992-2284
[L PASO, IX (9IS) 534-9110
Sot.t.T lAKE CITY, UT. (801) 261-'''55
ENGINEERING CORPORATION
DR: DAILEY
.
.
,.,
1
SERVICE
DISC.
L
1
1
1
ELECTRIC
SERVICE
POLE
RTU r;\
PANEL ~
UTILITY CO.
METER
PUMP CONTROL 1
PANEL
1
1
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\..2J' ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
;-:;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
AND
1
1
1
L
1
ALARM
RELAY
PANEL
I, II Ii II CORPIJS CltRtSTl. TX. (361) 992-228'
II I n PASO. TX (915) 534-9110
SAlT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
i
L
I
~
N
o
"
w
o
w
"'
o
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1056 - PELICAN BAY
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
-
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
\E
o
ri
o
"
w
o
'"
"'
o
1::11i11
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1056 - PELICAN BAY
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, lX. (361) 992-2284
[l PASO, Tx (915) 534-9110
SALT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
~
~
~
STATION NO.
1057
~
-
~
ANCHOR HARBOR
LIFT STATION
- -,. -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 057
ANCHOR HARBOR
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 8102 South Padre Island Dr. LOCALE: West of Sealane
SUBDIVISION: Anchor Harbor WASTEWATER PLANT: Oso
LATITUDE: N27041.282' LONGITUDE: W97019.326'
PUMPS: (2) 10HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): FORCE MAIN:
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap that is 42-inches above grade. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Vehicle access
around the wet well structure is limited.
Electrical power is obtained from an overhead electrical service. Control equipment consists of a
Pump Control Panel, RTU panel, and alarm reiay panel. All enclosures, including electric meter and
service disconnect, are mounted on the service pole. All control devices, including pump motor
starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2930
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1057-1 High Level
1057-2 Main Power Faiiure
1057-3 Motor #1 Failure
1057-4 Motor #2 Failure
1057-5 Control Power Failure
08/13/01 5:12 PM
Station Data Sheet. doc
-
-
STATION NO: 1057
ANCHOR HARBOR
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1057X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1057Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1057Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1057A 1 st Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-1057B 2nd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSH-1057 Wet Well High Level EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSL-1057 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1057A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1057B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1 057 A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1057B Pump #2 Overload DEMO Control Relay Pump Control
I Panel
--..--. ,~-- ----------
Station Instrument Index Report
08/13/200105:43 PM
-
-
DIRECTIONAL
ANTENNA
SERVICE
UTILITY CO.
METER AND
SERVICE
DISC.
(0 REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
~
o
"
w
o
~
"'
o
II -Iii II CORPUS CHRISTI. TL ('OIl 99'-"84
II I n PASO. TX (915) 534-9110
ENGINEERING CORPORATION SAlT lAKE CITY, UT. (801) 261-1455
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1057 - ANCHOR HARBOR
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.
I.
~
DIRECTIONAL
ANTENNA
SERVICE
J
1
RTU
PANEL
1
1
PUMP CONTROLl
PANEL
ALARM
RELAY
PANEL
1
UTI L1TY CO.
METER
SERVICE
DISC.
1
1
WET WELL
ACCESS
1
J
J
J
1-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.2.; ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
AND
1
1
'"
"
o
N
o
"
w
o
...
'"
o
1
1
I'll Ii II CORP1JS CliRISTI. lX. (361) "'-'28'
II I (l PASO, lX (glS) 534-9110
SAlT LAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHR5TI
WASTEWATER DEPT.
PROJECT NO.-nOO
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1057 - ANCHOR HARBOR
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
J
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'-'
"
o
ri
o
"
w
c
~
"'
o
1=11 Ii II
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1057 - ANCHOR HARBOR
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, IX. (361) 992-2284
EL PAS/). TX (915) 5J4-9110
SAlTL.AK[ClTY,UT. (801)261-1455
ENGINEERING CORPORATION
I r
II
m
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
STATION NO.
1058
TRAVEL TRAILER
LIFT STATION
- I r 11 I' . .
r1'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1058
TRAVEL TRAILER
-
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 9441 South Padre Island Dr. LOCALE: South of SH 358
SUBDIVISION: Lexington Center WASTEWATER PLANT: Laguna Madre
..-
LATITUDE: N27040.411' LONGITUDE: W97018.025'
PUMPS: (2) 10HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 8"CIP
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is remotely located and does not have a security fence. Vehicle access to the
station is possible from one side behind golf driving range.
Electrical service is routed to the lift station from an overhead service pole. The electric meter and
service disconnect are located on the service pole. Control equipment consists of a Pump Control
Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry wall on
metal strut support brackets. All control devices, including pump motor starters, are located in the
Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Wood (Exist)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2960
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1058-1 High Level
1058-2 Main Power Failure
1058-3 Motor #1 Failure
1058-4 Motor #2 Failure
1058-5 Motor Control Power Failure
1058-6 Float Control Failure
08/13101 5:12 PM
Station Data Sheet.doc
.
.
-
STATION NO: 1058
TRAVEL TRAILER
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS; 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
-- _.~~
JS-1058X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1058Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1058Z RTU ClrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1058A 1st Pump Start EXISTiNG Float Switch New Junction Box DI 1~~trinSiCaIlY safe barrier relay
required
LS-10588 2nd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSH-1058 Wet Well High Level EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSL-1058 Wet Welt Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1058A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10588 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-105SA Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10588 Pump #2 Overload OEMO Control Relay Pump Control
Panel
.- -
Station Instrument Index Report
08/13/200105:43 PM
_ r
-
-
DIRECTIONAL
ANTENNA
-
-
ELECTRIC
SERVICE
POLE
-
UTILITY CO.
METER AND
SERVICE
DISC.
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
;t
"!
o
:>
w
o
m
"'
o
I' -Iii II CORJ>uS CHRIST'. Tx. ('OIl 992-2'8<
I tiEL PASO. TX (915) 534-9110
SAlTLAKtClTY UT. (801)261-1455
ENGINEERING CORPORATION .
CITY Of" CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1058 - TRAVEL TRAILER
DR; DAILEY DATE: 03/2000 SHEET 1 OF 3
PUMP CONTROL
PANEL
RTU
PANEL
J
1
1
ELECTRIC
SERVICE 1
POLE
UTILITY CO. 1
METER
O DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
1 ASSOCIATED UNISTRUT SUPPORTS.
~ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
"
'"
o
N
o
"
w
o
"'
"'
o
11111i11 C<lRPUSCHRr.'fCn. (361)99'-'28'
EL PASO. IX (915) 534-9110
II I So\LT lAKE CRY, uT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of' CORPUS CHRISn
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1058 - TRAVEL TRAILER
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
-
-
1
1
1
1
1
1
1
L
L
L
L
L
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
;t
o
ri
o
"
w
o
'"
"'
o
1:11 Ii II
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1058 - TRAVEL TRAILER
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, IX. (361) 992-2284
EL PASO. IX (915) >>4-9110
s.\LT LAK[ CITY, UT. (801) 261-14~
ENGINEERING CORPORATION
- ~
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
...
...
- STATION NO.
1059
TURTLE COVE
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 059
TURTLE COVE
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
I ADDRESS: 9547 Blue Jay Street
I SUBDIVISION: Turtle Cove
I LOCALE: North of SH 358
---'--~--'-'-j
........---.--!
I LATITUDE: N27"40.748'
i WASTEWATER PLANT: Laguna Madre
........----~_____r---..--.-...........-.~-.-...--.....-......-.----.-~-
i LONGITUDE: W97017.811'
,
i
-............................-1
I
-
, ; I
r----.-.--.....--------.-~-------.--.....'..-----.-.--------..,----.-..,..-..,.-.-..----------.--..--.-.----.~-------....-......--.---1
I PUMPS: (2) 20HP I SERVICE VOLTAGE: 240/120V, 3PH, 4W
i FORCE MAIN: 8" ACP
,
_______i.. .....n...____........___._____________,_._.,___........,......__..._._..._____________m__n.....____...__________n____'__________
I INFLUENT PIPE(S):
-
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a brick wall inside a
wooden security fence. The station is located adjacent to the street with a service driveway. Vehicle
access to the station is possible from one side.
Electrical service is routed underground to the lift station from local pad mounted transformers. The
eiectric meter and service disconnect are located on brick wall. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the brick wall.
All control devices, including pump motor starters, are located in the Pump Control Panel. Conduits
are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2930
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1059-1 High Level
1059-2 Main Power Failure
1059-3 Motor #1 Failure
1059-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
-
STATION NO: 1059
TURTLE COVE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1059X Main Power Failure NEW Phase Failure Monitor Pump Control DI ----~~_.._-
Relay Panel
JS-1059Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1059Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1059A 151 Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10598 2nd Pump Slart EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1059 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1059 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1059A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10598 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1059A Pump #1 Overload DEMO Control Relay Pump Control I
Panel
YS-10598 Pump #2 Overload DEMO Control Relay Pump Control
Panel
L -.-
Station Instrument Index Report
08/13/200105:43 PM
- ,.
,..
~'"
-
DIRECTIONAL
ANTENNA
BLUE JAY ST.
-
-
-
-
-
-
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
;t
'"
;;
'"
w
o
m
"'
o
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASlEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (361) 992-228.
EL PASO, TX (915) ~-9110
SALT LAKE ClTY,UT. (1501)261-1.55
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1059 - TURTLE COVE
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
.
I'
1""
CHEMICAL TANK
TRANSFORMER
PUMP CONTROL
PANEL
SERVICE
DISC.
G DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU
(;) DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
o REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE
\J ENCLOSURE RATING.
PANEL.
NEMA
"
~
N
o
"
w
o
m
"'
o
II II Ii II C<JRPUS CHRIST'. TX. (361l 992-""
II I n PASO. TX (915) 534-9110
SfIlT lAKE CITY, UT. (801) 261-1"~
ENGINEERING CORPORATION
CITY Of' CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
L
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1059 - TURTLE COVE
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
- ..
-
J
RTU
PANEL
J
J
J
J
1
1
ALARM 1
RELAY
PANEL .
1
1
1
1
i
1
L
L
~
-
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
;t
o
ri
o
"
w
o
m
"'
o
1:11 Ii II
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1059 - TURTLE COVE
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPuS CHRISTI, IX. (J61) 992-2284
EL PASO, TX (915) 534-9110
SAlT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
Wastewater Department
.._ Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
~
~
-
STATION NO.
1060
MILITARY & JESTER
LIFT STATION
- . ~ 'I
T
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 060
MILITARY & JESTER
-
STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
ADDRESS: 722 Jester Street LOCALE: Intersection of Military Drive and Jester
SUBDIVISION: Naval Center WASTEWATER PLANT: Laguna Madre
LATITUDE: N27040.619' LONGITUDE: W97016.925'
PUMPS: (2) 50HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 10"CIP
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway with no security fence. Lift pumps are located in the dry well and the
top of the structure is flush with grade. Vehicle access to the station is possible from three sides.
Electrical service to the iift station is routed from pole mounted transformers. The electric meter is
mounted on building exterior and main service disconnect is located in building interior. Control
equipment consists of an MCC wi starters, Pump Control Panel, RTU panel, and alarm relay panel.
All enclosures are mounted on the masonry wall. All control devices, level control relays, and pump
sequencing controller are located in the MCC. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with a pressure transducer level sensor interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2920
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1060-1 Wetwell High Level
1060-2 Main Power Failure
1060-3 Motor #1 & #2 Failure
1060-4 Dryweil High Level
08113/01 5:12 PM
Station Data Sheet.doc
- ,.
I"
" -.,
STATION NO: 1060
MILITARY & JESTER
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1060X Main Power Failure NEW Phase Failure Monitor MCC DI
Relay
JS-1060Y Pump Ctr1 Pwr Failure NEW Control Relay (120 VAC MCC DI
coil)
JS-1060Z RTU Clri Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1060A 1st Pump Start EXISTING Current Relay Pump Control DI Absolute Process Relay
Panel
LS-1060B 2nd Pump Start EXISTING Current Relay Pump Control 01 Absolute Process Relay
Panel
LSH-1060 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
-- -~
LSHH-1060 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1060A Pump #1 Run Status NEW Motor Starter N.D. Aux MCC DI
Contact
XS-1060B Pump #2 Run Status NEW Motor Starter N.O. Aux MCC DI
Contact
YS-1060A Pump #1 Overload DEMO Control Relay MCC
YS-1060B Pump #2 Overload DEMO Control Relay MCC
----- ..
Station Instrument Index Report
08/13/200105:43 PM
.
r
-
rr
PUMP
BLDG.
69KV POWER
POLES
.'
-
,
~
-
JESTER
MILITARY DR.
DIRECTIONAL ANTENNA
(UNDER CARPORT)
o REMOVE ANTENNA, ANTENNA SUPPORT PiPE AND ALL ASSOCIATED HARDWARE.
'-'
~
o
o
:>
w
o
o
w
o
1=111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI. lX. (361) 992-2284
[L PASO. TX (915) 534-9110
$.\LTLAKECIlY,Ul. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1060 - MILITARY & JESTER
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
_ r
-
LIFT
PUMP
PUMP CONTROL
PANEL
MOTOR CONTROL
CENTER
,\".~
(2) DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
o REPAIR ALL HOLES iN MOTOR CONTROL CENTER.
"
;t
o
'"
o
"
w
o
o
~
o
It II Ii II CORPUS CHRoSn. lX. (J6.> 99'-""
[L PASO, TX (915) 534-9110
II I SAlT lAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTl
WASTEWATER DEPT.
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1060 - MILITARY & JESTER
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
. -
r
-
TT
1
L
L
L
L
1
RTU
PANEL
L
1
LIFT
PUMP
L
1
1
L
I
1
1
PROJECT NO. 7100
L
-
-
-
-
-
-
"
'"
o
ri
o
"
w
o
o
'"
o
1=111i11
ENGINEERING CORPORATION
JOB NO.: 1075
.
..
1. TRACE OUT LEVEL CONTROLS AND ROUTE TO NEW
RTU.
CITY Of CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1060 - MILITARY & JESTER
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
[L PASO. IX (915) 534-9110
SAlT tAl([ CITY, UT. (801) 161-1455
".,
,-
~
~
...
~
-
~
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1061
S.P.A.30
LIFT STATION
.
I
T'1
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1061
s.P.A.30
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
~-~--------
____._.____...._.__.._....._.__....__.__....._..___...___________ .m.. ..m..... ..n m.. _____._______-1
i ADDRESS: Airline Rd.
I LOCALE: South of Saratoga
!---
i SUBDIVISION: Greenwood
!LATITUDE: N27040.144'
I WASTEWATER PLANT: Oso
---------------1
! LONGITUDE: W97021.829'
;
: _____~_______._____._...___._..,._.._._...__._._._ ....__..__________mn__
i SERVICE VOLTAGE: 480V, 3PH, 3W
------j--..---------....----------.---..---..-...-......
i FORCE MAIN:
_--1..___....".......... n. ..................u......._......___.___....._...____m________________~...___.._..
------;
i PUMPS: (2) 20HP
-----
I INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the electrical equipment. The station is accessed
from a service driveway with a security fence. Lift pumps are located in the wet well and the top of the
structure is flush with grade. Vehicle access to the station is possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is mounted on building exterior and main service disconnect is located in building
interior. Control equipment consists of an MCC wi soft starters, PLC based Pump Control Panel, RTU
panel, and alarm relay panel. All enclosures are mounted on the masonry wall. All control devices,
except level control relays and pump sequencing controller are located in the MCC. Conduits are rigid
or flexible PVC. Pumps are controlled by PLC control panel with a pressure transducer level sensor.
Trouble alarms are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3220
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1061-1 High Level
1061-2 Main Power Failure
1061-3 Motor #1 Failure
1061-4 Motor #2 Failure
1061-5 Motor Control Power Failure
08/14/01 5:03 PM
Station Data Sheet.doc
-
-
STATION NO: 1061
S.P.A.30
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 2
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
FT-1053 Effluent Flow EXISTING Flow Transmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-1061A Lift Pump 1 Molor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-1061B Lift Pump 2 Motor Current EXISTING 4-20mA Current Sensor PlC Control Panel COMM Analog data obtained from exist
PLC via comm link
JS-1061 Main Power Fail EXISTING Phase Failure Monitor PLC Control Panel COMM Alarm status obtained from
Relay existing PLC via comm link
JS-1061X Main Power Failure EXISTING MCB Aux Contacts PLC Control Panel COMM Alarm status obtained from exist
Pump Control PLC via comm link
JS-1061Y Pump PLC Ct~ Pwr EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from exist
Failure Pump Control PLC via comm link
.-
JS-1061Z RTU CtrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LSH-1061 Wet Well High Level EXISTING Float Switch PLC Control Panel DI Intrinsically safe barrier relay
required
LT-1061 Wet Well level EXISTING level Transmitter PlC Control Panel COMM Analog data obtained from exist
PlC via comm link
XS-1061A lift Pump 1 H-O-A , EXISTING H-O-A Aux Contact PLC Control Panel COMM Status obtained from exist Pump
Position Control PlC via comm link
XS-1061B Lift Pump 2 H-O-A EXISTING H-O-A Aux Contact PlC Control Panel COMM Status obtained from exist Pump
Position Control PlC via comm link
XS-1061C Lift Pump 1 Run Status EXISTING Motor Starter N.D. Aux PlC Control Panel COMM Status obtained from exist Pump
Contact Control PlC via comm link
XS-1061D lift Pump 2 Run Status EXISTING Motor Starter N.D. Aux I PlC Control ~~nel COMM Status obtained from exist Pump
! Contact Control PlC via comm link
I.. --^._~ -
Station Instrument Index Report
08/13/200105:43 PM
-
-
ELECTRICAL
BUILDING
DIRECTIONAL
ANTENNA
-
-
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
~
'"
o
"
w
o
"'
o
1=111i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (J61) 992-2284
[L PASO. TX (915) 534-9110
SAlT LAJ(ECllY,ul. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1061 - S.P.A. 30
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
1
FLOW
METER
PUMP CONTROL
PANEL (PLC)
1
1
1
i
1
1
1
1
1
1
L
L
L
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU ENCLOSURE.
"
;t
q
N
o
:>
w
o
<0
o
L
II II Ii II CORP\lS '"'''''. " I'''> 992-""
II I EL PASO. 1X (915) 5J4-9110
SALTI.Al((CITY,UT. (801)261-1455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1061 - S.P.A. 30
DATE: 03/2000 SHEET 2 OF 3
DR: DAILEY
-
-
"
;t
o
N
o
"
w
o
w
o
1=111i11
ENGINEERING CORPORATION
JOB NO.: 1075
1. PROVIDE COMMUNICATIONS INTERFACE BETWEEN
EXISTING MODICON QUANTUM PLC AND NEW RADIO
TELEMETRY SYSTEM
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPuS CHRISTI, TX. (J61) 992-2284
[l PASO. IX (915) 534-9110
SALT lAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1061 - S.P.A. 30
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
,-
-
STATION NO.
1062
WALDRON ROAD
LIFT STATION
---, " I I" ._-
T
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 062
WALDRON ROAD
-
STATION TYPE: Lift Station: Wet well, (3) submersible pumps
ADDRESS: 1350 Waldron Road LOCALE: West of Waldron RoadlNorth of Graham
SUBDIVISION: Flour Bluff Gardens WASTEWATER PLANT: Laguna Madre
LATITUDE: N27039.818' LONGITUDE: W97"17.133'
PUMPS: (3)5HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 12" PVC
-
-
PHYSICAL DESCRIPTION:
The lift station is a prefabricated metal building housing the electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Vehicle access to
the station is possible from one side.
Electrical service to the lift station is routed underground from pole mounted transformers. The electric
meter is located on building exterior. Control equipment consists of a Motor Control Center (MCC),
Pump Control Panel, RTU panel, and alarm relay panel. Pump Control Panel, RTU panel, and alarm
relay panel are located in the MCC. Conduits are rigid or flexible PVC. Enclosures and conduits are
in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2970
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1062-1 High Level
1062-2 Main Power Failure
1062-3 Motor #1 Failure
1062-4 Motor #2 Failure
1062-5 Motor #3 Failure
1062-6 Control Power #1 Failure
1062-7 Control Power #2 Failure
1062-8 24V Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1062
WALDRON ROAD
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 15
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1062X Main Power Failure NEW Phase Failure Monitor MCC DI
Relay
JS-1062Y Pump Ctr1 Pwr Failure NEW Control Relay Pump Control DI
Panel
JS-1062Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1062A 1st Pump Start EXISTING Float Switch Pump Control DI 1~~trinSjcaIlY safe barrier relay
Panel required
LS-1062B 2nd Pump Start EXISTING Float Switch Pump Control DI 1~~trinsicaIlY safe barrier relay
Panel required
LS-1062C 3rd Pump Start EXISTING Float Switch Pump Control DI 1~~trinsicaHY safe barrier relay
Panel required
..----- -- _nO
LS-1062D 4th Pump Start FUTURE Float Switch Pump Control DI 1~~trinsicaIlY safe barrier relay
Panel required
LS-1062E 5th Pump Start FUTURE Float Switch Pump Control DI 1~~trinsicaIlY safe barrier relay
Panel required
LSH-1062 Wet Well High level EXISTING Float Switch Pump Control DI l~ntrinsicallY safe barrier relay
Panel required
LSL-1062 Wet Well Low Level EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
I Panel required
XS-1062A Pump #1 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
XS-1062B Pump #2 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
--~ ~.~.- --_.._----~-
XS-1062C Pump #3 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
XS-1062D Pump #4 Run Status FUTURE Motor Starter N.O. Aux MCC Motor DI
Contact Starter
XS-1062E Pump #5 Run Status FUTURE Motor Starter N.D. Aux MCC Motor DI
Contact Starter
YS-1062A Pump #1 Overload DEMO Control Relay MCC Aux. Cubide
YS-1062B Pump #2 Overload DEMO Control Relay MCC Aux. Cubide
YS-1062C Pump #3 Dver10ad DEMO Control Relay MCC Aux. Cubicle I
i
- ___0 .._-;
Station Instrument Index Report
08/13/200105:43 PM
-
-
....
....
....
DIRECTIONAL
ANTENNA
MOTOR CONTROL
CENTER BLDG.
....
....
....
....
WALDRON
ROAD
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
;t
~
o
"
w
o
N
'"
o
,,:,.
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1062 - WALDRON ROAD
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI. lX. (J61) 992-2284
(L PASO, TX (915) 5J4-!iI110
SALT lAKE CITY, UT. (BOI) 261-1455
ENGINEERING CORPORATION
~
;~
1
1
RTU AND 1
ALARM RELAYS
CUBICLE
1
I
.....
PUMP CONTROL
CUBICLE
1
1
MCC
BLDG.
1
1
1
1
I
....
/-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU AND ALARM
\.2.J RELAYS FROM CUBICLE.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1062 - WALDRON ROAD
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
"
'"
o
N
o
"
w
o
N
~
o
11.11i II CORPuS CM'"'' lX. 1361) 992-228'
II I [L PASO. TX (915) 534-9110
SALT lAKE CITY, uT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF" CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
1
L
PROJECT NO. 7100
L
L
I
-
RTU
-
["
,"~. .::,
" "
;<~t
PUMP
CONTROL
CUBICLE
"
;t
o
ri
o
"
w
o
N
'"
o
1. REMOVE RTU AND ALL ASSOCIATED WIRING AND HARDWARE.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
1=111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
ENGINEERING CORPORATION
CORPUS CHRISTI. lX. (361) 992-2284
[l PASO, TX (915) 5)4-9110
WT LAK[ CITY. UT. (BOI) 261 ~ 1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1062 - WALDRON ROAD
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
,...
STATION NO.
1063
~
-
PURDUE
LIFT STATION
----,. t. I ". .~ Jl
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 063
PURDUE
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 630 Purdue Road LOCALE: West of Waldron Road
SUBDIVISION: Stoddart Smith WASTEWATER PLANT: Laguna Madre
LATITUDE: N27039.034' LONGITUDE: W97"17.719'
PUMPS: (2) 7.5HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 6"CIP
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap that is flush with grade. The station is accessed
from a service driveway and is surrounded by a chain link security fence. Vehicle access around the
wet well structure is limited.
Electrical service to the lift station is routed underground from pole mounted transformers. Control
equipment consists of a Pump Control Panel, RTU panel, and alarm reiay panel. All enclosures are
mounted on a metal pipe rack. Electric meter and service disconnect, are mounted on the service
pole. All control devices, including pump motor starters, are located in the Pump Control Panel.
Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3040
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1063-1 High Level
1063-2 Main Power Failure
1063-3 Motor #1 & #2 Failure
1063-4 Motor Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- ~
'.
STATION NO: 1063
PURDUE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
JS-1063X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1063Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1063Z RTU Ctrf Pwr Failure NEW 120VAC Digitallnpul RTU Panel DI
LS-1063A 1 sl Pump Start EXISTING Float Switch New Junction Box DI 1~~trjnsicaIlY safe barrier relay
required
LS-10638 2nd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicallY safe barrier relay
required
LSH-1063 Wet Well High Level EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSL-1063 Wet Well Low Level EXISTING Floal Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1063A Pump #1 Run Stalus NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10638 Pump #2 Run Stalus NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1063A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10638 Pump #2 Overload DEMO Control Relay Pump Control
Panel
YS-1063C Pump #3 Overload DEMO Control Relay Pump Control
Panel
~---- ~----
Station Instrument Index Report
08/13/2001 05:43 PM
ELECTRIC SERVICE POLE
DIRECTIONAL
ANTENNA
-
-
UTiliTY CO.
METER AND
SERViCE DISC.
PURDUE RD.
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
;t
o
o
:>
w
o
..,
~
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PRCWECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1063 - PURDUE
DATE: 03/2000 SHEET 1 OF 3
CORPuS CHRISTI, TX. (J61) 992-2284
tL PASO, lX (91~) ~-9ItO
SAlT LN([ CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
. ..
I.
-
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1063 - PURDUE
DATE: 03/2000 SHEET 2 OF 3
DIRECTIONAL
ANTENNA
RTU
PANEL
XFMR.
PUMP
CONTROL
PANEL
VALVE BOX
ACCESS
r:\ DISCONNECT POWER, ANTENNA AND ALARM WIRiNG. REMOVE RTU PANEL
V ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3.../ ASSOCIATED UNISTRUT SUPPORTS.
/";\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
'-'
~
N
o
"
w
o
..,
<0
o
II -Iii II CORPuS CHRlSTI. lX. (361) 992-"84
I t I ~~:[T~rrY. UT. ~:~~ :~=~~:
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER OEPT.
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
.
1
1
1
1
1
ALARM 1
RELAY
PANEL 1
WET WELL
ACCESS 1
VENT
1
1
1
1
AND
I
~
1
1
1
1
PROJECT NO. 710C.
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
;t
o
ri
o
"
w
o
'"
'"
o
1=111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1063 - PURDUE
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTl, Tlt (361) 992-2284
[L PASO, TX (915) 5.}4-9110
SAlT LAKE CITY, UT. (801) 261-14~
ENGINEERING CORPORATION
DR: DAILEY
.
II
r
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1064
RETT A PLACE
LIFT STATION
---. . ~
r
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 064
RETIA PLACE
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
--rCOCACE:-'EasfotFJoursluffDr.andSoulhof
: Purdue Rd
_._~-_.._-----+-----.""---_..,.._-_._----_._._-,._.~---------_._._.._..._--------~--_._._..,.._._---- ...-........ ... ....----
ADDRESS: 2443 Vialoux Drive
: SUBDIVISION: Retia Place
I WASTEWATER PLANT: Laguna Madre
,L..__....__________....__..._
I LATITUDE: N27039.144'
...------;---------..................------------.............--.---------.................---.-
,
~---._-_... -
,
! LONGITUDE: W97"18.486'
1........-------...........-----..-............--.---.....----.-.-...
I SERVICE VOLTAGE: 240/120V, 3PH, 4W
I PUMPS: (2) 5HP
r--------......
1 INFLUENT PIPE(S):
L__
I FORCE MAIN: 6" PVC
,
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by what used to be a
decorative masonry block wall. The station is located adjacent to the street and does not have a
service driveway or security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on a metal pipe support
rack. All control devices, including pump motor starters, are located in the Pump Control Panel.
Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 306"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1064-1 High Level
1064-2 Main Power Failure
1064-3 Motor #1 Failure
1064-4 Motor #2 Failure
1064-5 Motor Control Power Failure
1064-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet. doc
-
STATION NO: 1064
RETTA PLACE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-1064A Pump #1 Power Failure DEMO Control Relay Pump Control . -------,
Panel
JS-10646 Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1064X Main Power Failure EXISTING Phase Failure Monitor Pump Control DI
Relay Panel
JS-1064Y Pump Ctrt Pwr Failure NEW Control Relay (120 VAC Pump Control DI
coil) Panel
JS-1064Z RTU Ctri Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1064A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10646 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1064 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1064 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1064A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
XS-10646 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1064A Pump #1 Overload DEMO Control Relay Pump Control
Panel
---- ..~ ,--.
YS-10646 Pump #2 Overload DEMO Control Relay Pump Control
Panel
Station Instrument Index Report
08/13/200105:43 PM
~
ELECTRIC
SERVICE
POLE
WET WELL
ACCESS
UTILITY CO.
METER AND
SERVICE DISC.
VALVE BOX
ACCESS
RETTA PARK
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
;t
q
o
"
w
o
..
'"
o
It II Ii II CORPUS CHOSTI. rx. (J6IJ 99'-22"
t 41 I [L PASO, TX (915) 534-9110
SAlT lAKE CITY, UT. (801) 261-145!1
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROuECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1064 - RETIA PLACE
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
- ~
-
DIRECTIONAL
ANTENNA
RTU
PANEL
ALARM
RELAY
PANEL
1
1
1
1
1
RETTA PARK
1
PUMP CONTROL 1
PANEL
WET WELL
ACCESS
1
1
1
1
L
L
L
~
;-;\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2..J ASSOCIATED UNISTRUT SUPPORTS. .
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2.; ENCLOSURE RATING.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1064 - RETIA PLACE
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
~
N
o
"
w
o
..
'"
o
II II Ii II CORPUS CHRISTI. Tx. ,,.,) 99'-228'
I t I [l PASO. TX (915) 534-9110
SAlT l..AIC[ CI1Y, UT. (801) U1-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
PROJECT NO. 7100
-
,
g"J
..
.., i
\i
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
ri
o
"
w
o
..
U>
o
1111 Ii II CORP\lS CH.S1l. lX. ('''> 99'-"84
El PASO. TX (91S) 534-9110
II I SAlT LAK[ CfJY, Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1064 - RETIA PLACE
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
. .
II
T'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1065
RIVIERA
LIFT STATION
I . II
Ii
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1065
RIVIERA
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
~. __.""...n.
ADDRESS: 138 Riviera Road LOCALE:
East of Laguna Shores Road
i SUBDIVISION: Laguna Vista Shores
r LATITUDE: N27037.365'
I WASTEWATER PLANT: Laguna Madre
I ...-,...-,..".."--.-.-------~----.-...-..-.--~----.-----......--......----------m-_........-...---.--.--'1
I LONGITUDE: W97017.724'
-----------------j
! PUMPS: (2) 10HP
[INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
i SERVICE VOLTAGE: 480V, 3PH, 3W
__._m._....___.....____,___.__ ......__........_____,___....__........._ .. _._______________........;
i FORCE MAIN: 6"
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and has a service driveway without a security
fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, circuit panel, RTU panel, and alarm relay panel. All enclosures are mounted against
the masonry wall on metal strut support brackets. All control devices, including pump motor starters,
are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits
are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3120
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1065-1 High Level
1065-2 Main Power Failure
1065-3 Molor #1 Failure
1065-4 Motor #2 Failure
1065-5 Motor Control Power Failure
1065-6 Float Control Failure
08/13/01 5: 12 PM
Station Data Sheet. doc
.
If
r
STATION NO: 1065
RIVIERA
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
~_~M ...---
JS-1065X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1065Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil> Panel
JS-1065Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1065A 1 sl Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10658 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1065 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1065 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1065A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10658 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1065A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10658 Pump #2 Overload DEMO Control Relay Pump Control
Panel
----
Station Instrument Index Report
08/13/200105:43 PM
-
-
~
LAGUNA
SHORES DR.
-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
!i
o
o
"
w
o
'"
w
o
It .1 Ii II CORPUS CH"-ilI. lX. (361) "2-2284
II I [L PASO. TX (915) ~-9110
SAlT LAKE CITY, UT. (801) 261-14~
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1065 - RIVIERA
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
-
-
DIRECTIONAL L
ANTENNA
L
L
PUMP L
CONTROL
PANEL
L
120V
PANELBOARD
L
TRANSFORMER
1
1
L
1
1
1
RTU
PANEL
ALARM
RELAY
PANEL
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
/'::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
r-:\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
"
~
'"
o
"
w
o
"'
'"
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
CORPuS O1R1STI. TX. (Jil) 992-2284
(L PASO. TX (91~) 5.}4-9110
SAlT LAK[ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1065 - RIVIERA
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
-
J
j
1
1
PROJECT NO. 7100
1
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'-'
~
,-;
o
"
w
o
"'
<0
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1065 - RIVIERA
DATE; 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, 1X. (361) 992-2284
[l PASO. 1X (915) 534-9110
SALT I.N([ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
.
II
11'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
STATION NO.
1066
REX
LIFT STATION
. r
[I
11'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1066
REX
-.--.-
,
,
! STATION TYPE: Lift Station: Wet well, (2) submersible pumps
! ADDRESS: 4046 Whitely Drive
LOCALE: Intersection of Carp Drive and Whitely
.___......____................____.__________.___.n__.._.............."..__'..._________________..............._.._.,__._____....m__._
...._.__.__._----------~
i SUBDIVISION: Yorktown Estates
I WASTEWATER PLANT: Laguna Madre
-.-.---~-~---_t..-m---..".-
I LONGITUDE: W97018.090'
i___.__.....__...__...._____________._...__.__..n_______._.__n________________.....__..!
I SERVICE VOLTAGE: 240/120V, 3PH, 4W I
I.~~~._.~...~...........-.---~~~~..-~.--..~~-~~.~....~..........-...--~.J
i FORCE MAIN: 8" PVC !
i .____n_______._______________.___._____.__..__.______....__.J
LATITUDE: N27036.944'
i
"
1.~~_~PS: (2) 5HP
I INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and does not have a service driveway or
security fence. Vehicle access to the station is possible from three sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
cond ition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole ~ Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. ~ Azimuth: 3160
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1066-1 High Level
1066-2 Main Power Failure
1066-3 Motor #1 Failure
1066-4 Motor #2 Failure
1 066~5 Motor Control Power Failure
1 066~6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
_ r
,.
STATION NO: 1066
REX
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-1066X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1066Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1066Z RTU Ctrl Pwr Failure NEW 120VAC Digitallnpul RTU Panel DI
LS-1066A 1st Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-10666 2nd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSH-1066 Wet Well High Level EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
-~.,._---,---~- ---_._-_._~-- EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay --
LSL-1066 Wet Well Low Level
required
XS-1066A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10666 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1066A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10666 Pump #2 Overload DEMO Control Relay Pump Control
Panel
-. -----
Station Instrument Index Report
08/13/200105:43 PM
-
-
-
DIRECTIONAL
ANTENNA
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
'"
o
"
w
o
<0
<0
o
1:111i11
CITY OF CORPUS CHRISTl
WASTEWATER OEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1066 - REX
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTl. lX. (J61) 992-2284
n. PASO, TX (9IS) S34-9110
SAlT lAKE CITY. Uf. (801) 2451-1455
ENGINEERING CORPORATION
DR: DAILEY
-
-
1
1
1
1
PUMP
CONTROL
PANEL
1
ALARM
RELAY
PANEL
1
1
RTU
PANEL
1
1
1
L
L
o
(3)
(2)
DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
L
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
L
"
~
N
o
"
w
o
'"
'"
o
L
L
1:111i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100 '
CORPuS CHRISTl, TX. (361) 992-2284
[L PASO, 1X (915) S34-9110
SALT LAKE CITY, Uf. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1066 - REX
DATE: 03/2000 SHEET 2 OF 3
L
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
-
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
,.
o
ri
o
"
w
o
"'
"'
o
1:11 Ii II
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
CORPvS CHRISTI, IX. (361) 992-2284
tL PASO. IX (5115) 534-9110
SAlT LAKE CIlY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1066 - REX
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
-
-
STATION NO.
1067
KENNEDY CAUSEWAY
LIFT STATION
-" -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1067
KENNEDY CAUSEWAY
-----------_._-----"_._~
i ,
i STATION TYPE: Lift Station: Wet well, (2) submersible pumps ,
, ,
r ADDRESS: 13301 Padre Island Drive i L6cA[E:~Easisiaeiiiterc(iasfafcariaf-AtPubnc~...-"1
! i Restroom
~_._-_. ------.-i----------..-.......--------.....-.......------------__.......m..___..._____n__.'__m.n__________.......u.n.-----,-.
f SUBDIVISION: Kennedy Causeway
,- ---
I LATITUDE: N27038.052'
~_.- .
i.."'!~~TE~~~~~~~~~~~~"'!~iteca~
- ___m'_.
i LONGITUDE: W97014.316'
......-.-------.-.--...---------.---.-.------__._.__.__.~__..u__..________n......___l
I SERVICE VOLTAGE: 240/120V, 3PH, 4W .
I ....---..--.---_.__._._._____._...______._..._.____.__...----.-...-------------....-------1
I FORCE MAIN: 4" CIP ,
f PUMPS: (2) 5HP
ilNFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. A masonry brick public restroom building houses
the electrical equipment. The station is accessed from a service driveway. Lift pumps are located in
the wet well and the top of the structure is flush with grade. Vehicle access to the station is possible
from all sides.
Electrical service to the lift station is routed overhead from a pole mounted transformer. The electric
meter and main service disconnect is mounted on building exterior. Control equipment consists of
Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on the masonry
wall. All control devices are located in the Pump Control Panel. Conduits are rigid or flexible PVC.
Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2990
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1067-1 High Level
1067-2 Main Power Failure
1067-3 Motor #1 Failure
1067-4 Motor #2 Failure
1067-5 Motor Control Power Failure
1067-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
_ r
-
STATION NO: 1067
KENNEDY CAUSEWAY
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1067X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1067Y Pump Ctr1 Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1067Z RTU ClrI Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1067A 1 sl Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1067B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1067 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe banier relay
required
LSL-1067 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1067A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-1067B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1067A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1067B Pump #2 Overload DEMO Control Relay Pump Control
Panel
'-------
Station Instrument Index Report
08/13/2001 05:43 PM
.
II
,.,
-
BRIDGE
PILE
UTILITY CO.
METER AND
SERVICE DISC.
-
-
-
-
WET WELL
JUNCTION
BOX
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
"
o
"
w
o
~
'"
o
II II Ii II CORPUS "'.STf. lX. (361) 99'-'28'
II . [L PASO. TX (915) 534-9110
SAlT lAKE CITY. Uf. (BOI) 261-1455
ENGINEERING CORPORATION
CITY OF CORPuS CHRISTl
WASTEWATER DEPT.
PROU[CT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1067 - KENNEDY CAUSEWAY
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
. r I"
RTU
PANEL
1
1
ALARM
RELAY
PANEL
LIGHTING
PANEL
1
1
1
1
1
1
1
1
i
1
L
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
f3\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAiNTAIN THE NEMA
~ ENCLOSURE RATING.
L
f;l
o
N
o
"
w
o
~
'"
o
L
1:111i11
CITY or CORPUS CHRlSn
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1067 - KENNEDY CAUSEWAY
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
CORPUS CHRlSIl. TX. (361) 992-2284
[l PASO. TI (IU!I) 534-9110
ENGINEERING CORPORATION SALT LAKE: CITY, Uf. (SOl) 261-1455
- ~
-
"
~
ri
o
"
w
o
...
~
o
1:11 Ii II
ENGINEERING CORPORATION
JOB NO.: 1075
.
f
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REWIRE EXiSTING FLOAT SWITCHES.
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1067 - KENNEDY CAUSEWAY
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, IX. (361) 992-2284
El PASO, TX (91!J) 534-9110
SAlT lAKE CIlY, Uf. (801) 261-1455
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1068
SEA HORSE
LIFT STATION
- I I
..
r
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1068
SEA HORSE
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
I ADDRESS: 14300 Dorsal Street
i SUBDIVISION: Padre Island Section 2
i LOCALE: Sea Horse and Dorsal
---_._.._..,.._.,.._._._.__._~
~-_.
-t.---.--.,--.,..-.--------~- ....n ....m___._______,......_ .......___...._____n___.__
i WASTEWATER PLANT: Whitecap
....._._~
i LATITUDE: N27037.647'
! LONGITUDE: W97013.742'
c
i PUMPS: (2) 5HP
~
! INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
,
_______._._.,..,._._______~___.m_.'.._..,.._.________._____......
I SERVICE VOLTAGE: 240V, 1PH, 3W
___________._....m...._____j
_...___....u__n___ .. __ ~_.,._._._._._.__._.________..__..,._....._.__._.__________._.........._..
i FORCE MAIN: 6" CIP
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street and
does not have a service driveway or security fence. Vehicle access to the station is possible from all
sides.
Electrical service is routed underground to the lift station from pad mount transformers. The electric
meter is mounted behind Pump Control Panel. Control equipment consists of a Pump Control Panel,
RTU panel, and alarm relay panel. Pump Control Panel enclosure and electric meter are mounted on
a rack inside a fiberglass housing, and alarm relay panel and RTU are mounted on a metal pipe with
strut support brackets. All control devices, including pump motor starters, are located in the Pump
Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3000
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1068-1 High Level
1068-2 Main Power Failure
1068-3 Motor #1 Failure
1068-4 Motor #2 Failure
1068-5 Motor Control Power Failure
1068-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1068
SEA HORSE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-1068X Phase Failure Monitor Pump Control .--.-
Main Power Failure NEW DI
Relay Panel
JS-1068Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1068Z RTU Ctrl Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-1068A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10686 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1068 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1068 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1068A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10686 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-106SA Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10686 Pump #2 Overload DEMO Control Relay Pump Control
Panel
-~_._"_.-
Station InstnJment Index Report
08/13/2001 05:43 PM
.
II
r
-.
DORSAL ST.
WET WELL
ACCESS
PUMP CONTROL
PANEL ENCL.
SEA HORSE
AVE.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
;t
o
;:;
"
w
o
'"
<D
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1068 - SEA HORSE
DATE: 03/2000 SHEET 1 OF 3
CORPuS CHRISTI, TX. (361) 992-2284
El PASO. TX (915) 5)4-9110
SAlT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
DIRECTIONAL
ANTENNA
PUMP
CONTROL
PANEL ENCL.
WET WELL
ACCESS
RTU
PANEL
ALARM
RELAY
PANEL
VENT
r-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WiRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
AND
(3)
0)
REPAIR ALL HOLES IN PUMP CONTROL PANEL ENCLOSURE AND PUMP
CONTROL PANEL
'"
~
o
N
o
:>
w
o
'"
'"
o
L
L
l
L
L
L
L
L
L
I
~
L
1
1
1
L
1
II .1 Ii II CORP\JS CH.srl. IX. (36') 992-""
II I El PASO. TX (1115) ~-9t10
ENGINEERING CORPORATION SAlT WE CITY, UT. (801) 261-1455
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1068 - SEA HORSE
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
1
.
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'-'
;t
o
ri
o
"
w
o
"'
"'
o
I, II Ii II CORPUS CHOSTl. rx. (36'1 99'-'28'
II I El PASO. TX (915) SJ.$-9110
SAlT LAK[ CITY, UT. (801) 2eil-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1068 - SEA HORSE
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
Wastewater Department
._ Microwave Communication System
City of Corpus Christi
Project No. 7100
~
-
,,,-
STATION NO.
1069
JACKFISH
LIFT STATION
.. _ TT _ r
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1069
JACKFlsH
.-
i STATION TYPE: Lift Station: Wet well, (2) submersible pumps
-ADDRESS: -14124 Jackfish Street !LOCALE; --E~~i-~i-;~di~~-si~;~t--'---
,
---...........-----------.--...-\
-
SUBDIVISION: Padre Island Section 1 and 3
I LATITUDE: N27037.413'
I PUMPS: (2) 20HP
I INFLUENT PIPE(S): 15" VCP
,--.-------.-.--........--.----____....._________.__.___.... m.._..__________.._.__._.,.._______~
, i
L~~STE~~ TER_P~~.~~:_~hit=~~~_____.______,
I LONGITUDE: W97013.513' !
~-____..,."....---~-_--_-__m.-....'----_-_-------,.._--_---____......_____..__________....j
I SERVICE VOLTAGE: 240/120V, 3PH, 4W
i---.............---...--------..---."'.......-----....,.-...--.---___._._________........__.__.____J
I FORCE MAIN: 10" CIP I
, ,
~
'-.m
'----.--.----------.-.............--____________......__._.__.____......u..___.________.,
,...
PHYSICAL DESCRIPTION:
~
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap that is flush with grade. The station is located
adjacent to the street and is surrounded by a wooden security fence. Vehicle access around the wet
well structure is limited.
~
Electrical service is routed underground to the lift station from pad mount transformers. Control
equipment consists of a Pump Control Panel, RTU panel, and alarm relay panel. All enclosures,
including electric meter and service disconnect, are rack mounted. All control devices, including pump
motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures
and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 300.
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1069-1 High Level
1069-2 Main Power Failure
1069-3 Motor #1 Failure
1069-4 Motor #2 Failure
1069-5 Motor Control Power Failure
1069-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1069
JACKFISH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
------..-.
JS-1069X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1069Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1069Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1069A 15t Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10696 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1069 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1069 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1069A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10696 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1069A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10696 Pump #2 Overload DEMO Control Relay Pump Control
Panel
-- -._- -,," .-
Station Instrument Index Report
08/13/200105:43 PM
-
-
~
CHEMICAL
TANK
DIRECTIONAL
ANTENNA
~
.-
~
PARK
MANHOLE
<
JACKFISH AVE.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
C>
;t
o
o
"
w
o
m
w
o
~
1=111i11
CITY OF CORPuS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1069 - JACKFISH
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, TX. (Jtil) 992-2284
[l PASO. TIC (glS) 5.}4-9110
ENGINEERING CORPORATION SAlT I..AK[ CITY, UT. (801) 261-1455
DR: DAILEY
-
-
CHEMICAL
TANK
CHEMICAL
INJECTION
PUMP ENCL.
SERVICE DISC.
TRANSFORMER
WET WELL
ACCESS
RTU
PANEL
ALARM
RELAY
PANEL
PUMP
CONTROL
PANEL
O DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
1 ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
~
o
N
o
"
w
o
0>
"'
o
1:111i11
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1069 - JACKFISH
DATE: 03/2000 SHEET 2 OF 3
CORPUS CHRISTI. IX. (361) 992-2284
n PASO, IX (1115) 534-91 to
SAlT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
-
-
DR: DAILEY
1
1
1
1
1
1
1
J
j
J
1
1
1
L
i
-
FLOAT SWITCH
TERMiNAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. iNSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'-'
;t
o
ri
o
"
w
o
m
~
o
1=111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
CORPUS CHRISTI. TX. (361) 992-2284
EL PASO, Tx (915) 5J4-9110
s.LT LAKt CITY, Uf. (SOl) 261-1'155
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTlN PHOTOGRAPH
LIFT STA. 1069 - JACKFISH
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
.
11
J'!'T
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1070
SWORDFISH
LIFT STATION
.. - ~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 070
SWORDFISH
l.~TA~?_N TYPE:_ Lift Station: Wet well, (2) submersible pu_lllps__
;
! ADDRESS: 14500 Swordfish Street
I LOCALE: South of Cabana North
I PUMPS: (2) 5HP
~
i INFLUENT PIPE(S):
8"VCP
--~._.,._-,._..,..,-_..__.,.._...,..._.._._..._,...__..__._........---~--------_._..._..__._._._.._._...,....._.._,.._...--..._.-
! FORCE MAIN: 4" PVC
,
-------------------1
,
. .
_____--A................__................___............................___.____~______.__.....,_...._.,._.._._.__..,........_____.____.__________________~
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a cast-in-place concrete cap with no wall or fence. The station is located
adjacent to the street and has a service driveway without a security fence. Vehicle access to the
station is possible from all sides.
Electrical service is routed underground to the lift station from pad mount transformers. The electric
meter and service disconnect are located on a rack. Control equipment consists of a Pump Control
Panel, RTU panel, and alarm relay panel. All enclosures are rack mounted. The electricai service
equipment are mounted on a separate rack. All control devices, including pump motor starters, are
located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in
good cond ition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3010
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1070-1 High Level
1070-2 Main Power Failure
1070-3 Motor #1 Failure
1070-4 Motor #2 Failure
1070-5 Motor Control Power Failure
1070-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1070
SWORDFISH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-1070X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1070Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS- 1 070Z RTU CtrI Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-1070A 1 sl Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10706 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1070 Wel Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
--
LSL-1070 Wet Well Low Level EXISTING Floal Swilch New Junction Box DI Intrinsically safe barrier relay
required
XS-1070A Pump #1 Run Stalus NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-10706 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1070A Pump #1 OveMoad DEMO Control Relay Pump Control
Panel
YS-10706 Pump #2 Overload DEMO Control Relay Pump Control
Panel
-
Station Instrument Index Report
08/13/200105:43 PM
.
r
.
r
TRANSFORMER
ENCL.
WET WELL
ACCESS
VALVE BOX
ACCESS
SWORDFISH ST.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
\1
'"
o
"
w
o
o
~
o
1:111i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1070 - SWORDFISH
DATE: 03/2000 SHEET 1 OF 3
CORPVS CJ1RISTI, TX. (361) 992-2284
EL PASO. TX (915) >>4-9110
SALT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
DIRECTIONAL
ANTENNA
RTU
PANEL
ALARM
RELAY
PANEL
1
1
1
1
1
PUMP CONTROL .,
PANEL ~
WET WELL 1
ACCESS
VALVE BOX 1
ACCESS
J
J
I
~.
r-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
~ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
r:\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1070 - SWORDFISH
DATE: 03/2000 SHEET 2 OF 3
"
;t
o
N
o
"
w
o
o
~
o
IIII Ii II C<lRPUS ""lSTl. lx. (361) 992-228.
II I [L PASO. lx (91!l) 534-9110
WTlAKECIlY,UT. (1101)261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
.
I
1
1
J
PROJECT NO. 7100
1.
..
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'-'
;t
o
ri
o
"
w
o
o
~
o
1=111i11
CITY Of CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1070 - SWORDFISH
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
[L PASO, Tx (915) 534-9110
SAlT LAKE CITY, uT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
I r
II
IT'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1071
TESORO
LIFT STATION
- I r II
m
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1071
TESORO
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 13618 Port Royal Court LOCALE: North end of Tesoro Drive
SUBDIVISION: Point Tesoro 1, 2, and 3 WASTEWATER PLANT: Whitecap
LATITUDE: N27036.568' LONGITUDE: W97014.434'
PUMPS: (2)5HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 12" FORCE MAIN: 6"
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a cast-in-place concrete cap with no wall or fence. The station is located
adjacent to the street with a service driveway and no security fence. Vehicle access to the station is
possible from all sides.
Electrical service is routed underground to the lift station from local pad mounted transformers. The
electric meter and service disconnect are located on the rack. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures, including meter and main
disconnect, are mounted on rack. All control devices, including pump motor starters, are located in the
Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 306"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1071-1 High Level
1071-2 Main Power Failure
1071-3 Motor #1 Failure
1071-4 Motor #2 Failure
1071-5 Motor Control Power Failure
1071-6 Float Control Failure
08/13101 5:12 PM
Station Data Sheet. doc
STATION NO: 1071
TESORO
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
NEW Phase Failure Monitor Pump Control .-._-.~
JS-1071X Main Power Failure DI
Relay Panel
JS-1071Y Pump Gtrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1071Z RTU Ctr1 Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1071A 1st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-1071B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1071 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
e----- --~-_.._-~-~--
LSL-1071 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1071A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-1071B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1071A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1071B Pump #2 Overload DEMO Control Relay Pump Control
Panel
-. -----~_.
Station Instrument Index Report
08/13/2001 05:43 PM
-
-
PARK
DIRECTIONAL
ANTENNA
TRANSFORMER
WET WELL
ACCESS
PORT ROYAL COURT
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"'
;t
~
o
"
w
o
"-
o
1=111i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTl, TX. (361) 992-2284
El PASO, TX (915) 534-9110
SAlT LAKE CIlY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1071 - TESORO
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
-
1
DIRECTIONAL
ANTENNA
L
1
1
PUMP CONTROL 1,
PANEL
1
1
1
L
1
L
L
RTU
PANEL
ALARM
RELAY
PANEL
WET WELL
ACCESS
VENT
TRANSFORMER
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.2J ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
AND
1
L
'"
~
o
N
o
"
w
o
~
o
L
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
It II Ii II CORPUS '"RISTO. TX. (3<') 992-228.
It I El PASO. TIC (915) 534-9110
~TLAK[CITY,UT. (BOI) 261-145!1
ENGINEERING CORPORATION
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1071 - TESORO
DATE: 03/2000 SHEET 2 OF 3
1
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
-
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
~
o
1==1 Ii II
CITY OF CORPUS CHRlsn
WASTEwATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1071 - TESORO
DATE: 03/2000 SHEET 3 OF 3
CORPuS CHRISTI, TX. (361) 992-2284
[l PASO, TX (915) 534-9110
SALT lAIC[ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
I r
II
IT
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1072
AQUARIUS
LIFT STATION
- .. r I. W -.-., ,
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 072
AQUARIUS
i STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
I ADDRESS: 15000 Aquarius Street i.'LOcALE;-North-;;fWh;t~capBI~d~---"'---'-"
. i
--+---~_..._..._.,.._------~..___.____.~___._.____~_____.___.._.'m________._____.~
,
i SUBDIVISION: Barataria Bay
I WASTEWATER PLANT: Whitecap
i. __..".__.__._______,_,..,..,....__~__.._____.,.____~___._.._._.._._~_
I LONGITUDE: W97014.15T
i LATITUDE: N27036.448'
f------.--
i PUMPS: (2) 30HP
c-----____._.___
i INFLUENT PIPE(S): 24"
.._-~"----_......_...._--~---_...._.._..._~~--_.__._---,,_..__..- '''-'--'~---j
i SERVICE VOLTAGE: 240/120V, 3PH, 4W .
-...---~---~~_____J____....._.........__._____________.._,..___~______.__._._____...._._._.__._________......_......_._.;
I FORCE MAIN: 12" i
_.__.__~_.___1____________.__._.__._.~_~~____...__......_._._.~~______._________.._._...._._._.__.~._._.~~_"'_j
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is mounted in transformer interior and main service disconnect is located in building
interior. Control equipment consists of a Switchboard wi starters, Pump Control Panel, RTU panel,
and alarm relay panel. All enclosures are mounted on the masonry wall. All control devices, except
level control relays and pump sequencing controller are located in the Switchboard. Conduits are rigid
or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole. Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 306"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1072.1 Wetwell High Level
1072-2 Main Power Failure
1072-3 Motor #1 Failure
1072.4 Motor #2 Failure
1072-5 Drywell High Level
1072-6 Motor Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
..
..
STATION NO: 1072
AQUARIUS
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1072A Pump #1 Power Failure DEMO Control Relay Switchboard
JS-1072B Pump #2 Power Failure DEMO Control Relay Switchboard
JS-1072X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1072Y Pump Ctrl Pwr Failure NEW Control Relay (120 VAC Switchboard DI
coli)
JS-1072Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1072A 1 st Pump Start EXISTING Mechanical Sensor Switchboard DI Provide intrinsically safe barrier
relay for future float switch
LS- 1 072B 2nd Pump Start EXISTING Mechanical Sensor Switchboard DI Provide intrinsically safe barrier
relay for future float switch
LSH-1072 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSHH-1072 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1072 Wet Well Low Level EXISTING Mechanical Sensor Switchboard DI Provide intrinsically safe barrier
relay for future float switch
XS-1072A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1072B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
-.-.
YS-1072A Pump #1 Overload DEMO Controf Relay Switchboard
YS-1072B Pump #2 Overload DEMO Control Relay Switchboard
------ --..
Station Instrument Index Report
08/13/200105:43 PM
- -
DIRECTIONAL
ANTENNA
AQUARIUS ST.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
~
o
"
w
o
N
~
o
1==11i11
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1072 - AQUARIUS
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTl. TX. (361) 992-2284
E:l PASO. TX (915) 534-9110
SALT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
-
.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1072 - AQUARIUS
DATE: 03/2000 SHEET 2 OF 3
LIGHTING PANEL
RTU
PANEL
ALARM
RELAY
PANEL
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
'"
~
o
N
o
"
w
o
N
~
o
It II Ii II CORPUS ,"RISTo. n. (3<'1 992'228'
I t I 0. PASO. IX (915) 534-9110
ENGINEERING CORPORATION SAlT WE CITY, UT. (801) 261-1455
CITY Of' CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
- ~
1
1
SWITCHBOARD 1
i
i
SERVICE DISC. i
1
1
PUMP MOTOR
L
1
L
L
1
L
L
PROJECT NO. 7100
L
L
RTU
PANEL
ALARM
RELAY
PANEL
'"
~
o
..;
o
"
w
o
N
~
o
1. TRACE OUT MECHANICAL LEVEL SWITCHES AND
ROUTE STATUS TO RTU.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
It II Ii II CORPuS '""ST'. ". (36')"2-228'
II I EL PASO, Tx (915) 534-9110
SALT LAKE CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
I
SWITCHBOARD
PUMP CONTROL
PANEL
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1072 - AQUARIUS
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
r
., -
r
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1073
PADRE ISLAND SECTION
NO.4
LIFT STATION
t I r ..
r
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1073
PADRE ISLAND SECTION NO.4
i STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps
>...,---.....--.-- .__."_.".____n_____m.___....._........___.___________...,._..,.__..____~_~..._..___ ......__________............
ADDRESS: 14201 Whitecap Blvd. i LOCALE: East of Cruiser Street
.----------.--
__.__m_m'_.._._____..______~_..__.__.".._._______~__.._._.......__._m_mm__..............__.___....______ ...........____.___.
i WASTEWATER PLANT: Whitecap
i SUBDIVISION: Tradewinds #4
........_._______..___+____..n__...... ..... ..________._._........ ...______................_..______................_____ ._m_...._'..........._'
i LATITUDE: N27036.123'
i PUMPS: (2) 10HP
f-~-----
!INFLUENT PIPE(S): 24", 12"
~.
i LONGITUDE: W97013.463'
!
!
i SERVICE VOLTAGE: 480V, 3PH, 3W !
---+_._--_.__._.._._._-~_._-_._._._-----_...._.__._---_._.-........--....---------.............j
i FORCE MAIN: 14" DIP
I
PHYSICAL DESCRIPTION:
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. Vehicle access to the station is
possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is mounted on building exterior and main service disconnect is located in building
interior. Control equipment consists of a Switchboard wi starters, Pump Control Panel, RTU panel,
and alarm relay panel. All enclosures are mounted on the masonry wall. All control devices, except
level control relays and pump sequencing controller, are located in the Switchboard. Conduits are
rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 305"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1073-1 Drywell High Level
1073-2 Main Power Failure
1073-3 Motor #1 & #2 Failure
1073-4 Wetwell High Level
08/13/01 5:12 PM
Station Data Sheet.doc
-
-
STATION NO: 1073
PADRE ISLAND SECTION NO.4
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
.." roo . ..
JS-1073X Main Power Failure NEW Phase Failure Monitor Switchboard DI
Relay
JS-1073Y Pump Ctrt Pwr Failure NEW Control Relay Switchboard DI
JS-1073Z RTU Ctrt Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1073A 15t Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LS-10736 2nd Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LSH-1073 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
----
LSHH-1073 Dry Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1073 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1073A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10736 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1073A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10736 Pump #2 Overload DEMO Control Relay Pump Control
Panel
.. --_.._--
Station Instrument Index Report
08113/200105:43 PM
-
-
..
DIRECTIONAL
ANTENNA
..
..
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
'"
;:;
"
w
C>
....
~
o
1==11i11
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1073 - PADRE ISLAND SECT.
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
#4
CORPUS CHRISTl. IX. (361) 992-2284
[L PASO, III (915) 534-9110
SAlT lAKE CITY, UT. (1101) 261-1455
ENGINEERING CORPORATION
.
.
n
SWITCHBOARD
i
i
MOTOR
1
i
1
1
1
1
1
1
1
1
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL.
1
L
'"
~
o
N
o
"
w
o
..,
~
o
L
It II Ii II CORPUS CHRISTI. IX. ("') 99'-220'
Et PASO, TX (915) ~-gI10
It I SALTlAKECITY,UT. (801)261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1073 - PADRE ISLAND SECT.
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
#4
-
-
-
'"
~
o
..;
o
"
w
o
n
~
o
1==11i11
ENGINEERING CORPORATION
JOB NO.: 1075
1. TRACE OUT LEVEL CONTROLS AND ROUTE TO NEW
RTU.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1073 - PADRE ISLAND SECT.
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
#4
CORPUS CHRISTI, lX. (J61) 992-2284
EL PASO, Tx (915) 534-9110
SAlTl.AI([ CfIY, lIT. (801) 261-1<455
Wastewater Department City of Corpus Christi
Microwave Communication System Project No. 7100
-
-
STATION NO.
1074
GYPSY
LIFT STATION
- ~ -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1074
GYPSY
i STATION TYPE: Lift Station: Wet well, (2) submersible pumps
--,-'"-~----------' ---_._--_._-_.__...__._..__..,._~----~----_._--
ADDRESS: 15601 Gypsy Street I LOCALE: Gypsy and Whaler
! _____..____.........._........_............__......_______________moo..__.
SUBDIVISION: Tradewinds #4 ! WASTEWATER PLANT: Whitecap
I" ........-....................--....,.....-...-...--..------__________._._.__m.._......_...______
i LONGITUDE: W97013.803'
i
i LATITUDE: N27035.695'
i PUMPS: (2) 5HP
i INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
I SERVICE VOLTAGE: 240/120V, 3PH, 4W
i ......___......__n_____n__________. ........_..n....u.......__
! FORCE MAIN: 10"
,
-----....--.-{
The Iill station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a precast concrete cap with no wall or fence. The station is located
adjacent to the street with a service driveway. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lill station from a pad mounted transformer. The
electric meter and service disconnect are located on the rack. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on rack. All control
devices, including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC. Enclosures and conduits are in poor condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 II. - Azimuth: 3070
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1074-1 High Level
1074-2 Main Power Failure
1074-3 Motor #1 Failure
1074-4 Motor #2 Failure
1074-5 Motor Control Power Failure
1074-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
_ r
I"
STATION NO: 1074
GYPSY
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
--.-.--..- Phase Failure Monitor Pump Control
JS-1074X Main Power Failure NEW DI
Relay Panel
JS-1074Y Pump CtrI Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1074Z RTU Ctrl Pwr Failure NEW 120V AC Digital Input RTU Panel DI
r LS-1074A 1st Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicallY safe barrier relay
, required
L:S=1074B 2nd Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LSH-1074 Wet Well High Level EXISTING Float Switch New Junction Box DI I~~trinsica"y safe barrier relay
required
LSL-1074 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1 074A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-1074B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1074A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1074B Pump #2 Overload DEMO Control Relay Pump Control
Panel
----.-.-----.-.- .. ...
Station Instrument Index Report
08/13/2001 05:43 PM
.
I
T
DIRECTIONAL
ANTENNA
TRANSFORMER
ENCLOSURE
-
PAD MTD. SWITCHGEAR
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
o
;:;
"
w
o
.
~
o
1=111i11
ENGINEERING CORPORATION
CITY Of' CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (361) 992-2284
[l PASO, IX (915) 534-9110
SAlT LAKE CItY, Uf. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1074 - GYPSY
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
- ~
ALARM
RELAY
PANEL
L
L
L
RTU
PANEL
l
PUMP CONTROLl
PANEL
1
l
1
WET WELL
ACCESS
1
1
1
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.2..J ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
AND
1
o
o
1
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
J
'"
~
o
N
o
"
w
o
~
~
o
1
1.
1==11i11
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
ENGINEERING CORPORATION
CORPUS CHRISTI, lX. (J61) 992-2284
n PASO, TX (gl~) 5l4-9110
SAlT lAKE CITY. UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1074 - GYPSY
DATE: 03/2000 SHEET 2 OF 3
1
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
-
-
-
-
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
~
~
o
JOB NO.: 1075
SCALE: N.T.S.
CITY OF CORPUS CHRISTI
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1074 - GYPSY
DATE: 03/2000 SHEET 3 OF 3
WASTEWATER DEPT.
PROJECT NO. 7100
1==1 Ii II
CORPUS CHRISTI, TX. (J61) 992-2284
El PASO, lx (915) 530$-9110
SAlT lAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
.
F
"
"
Wastewater Department City of Corpus Christi
_. Microwave Communication System Project No. 7100
-
-
STATION NO.
1075
CUMANA
LIFT STATION
- -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1075
CUMANA
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
"---r----------------...--.--.. .....------__._......___.......______m.__._________m_..._.......-...........---..;
-
I ADDRESS: 15600 Cumana Street
I SUBDIVISION: Port 0' Calls
,
i LOCALE: Cumana and Cayo Can tiles
I WASTEWATER PLANT: Whitecap
-
I LATITUDE: N27035.724'
i PUMPS: (2) 5HP
LONGITUDE: Wgr14.251'
__m..__."....__..____._____________....____...__..____n____.........u__________..._._m......._.._____--<
I SERVICE VOLTAGE: 240V, 1 PH, 3W ,
---,'._---~-_._-_._._._.._.._-----_..,...,._._-~._.__.__.._-.-.----------j
: FORCE MAIN: 6" ACP
--_..____._.__._________..._.__.________....n__.___.____.............
i"'--'.
I INFLUENT PIPE(S): (2) a" PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap with no wall or fence. The station is located
adjacent to the street and does not have a service driveway or security fence. Vehicle access to the
station is limited due area landscaping.
Electrical service is routed underground to the lift station from a local pad mounted transformer.
Electric service includes a phase adder. The electric meter and service disconnect are located on the
rack. Control equipment consists of a Pump Control Panel, RTU panel, and alarm relay panel. Pump
Control Panel enclosure and electric meter are mounted on a rack inside a fiberglass housing with a
separate panel for HOAs and Run Time Meters, and alarm relay panel and RTU are mounted on a
metal pipe with strut support brackets. All control devices, including pump motor starters, are located
in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 30ao
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1075-1 High Level
1075-2 Main Power Failure
1075-3 Motor #1 Failure
1075-4 Motor #2 Failure
1075-5 Motor Control Power Failure
1075-6 Float Control Failure
08/13/01 5: 12 PM
Station Data Sheet.doc
.
I.
STATION NO: 1075
CUMANA
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
JS-1075X Main Power Failure NEW Phase Failure Monitor Pump Control ---^--
DI
Relay Panel
JS-1075Y Pump ClrI Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1075Z RTU Ctrt Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1075A 151 Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1075B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1075 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1075 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1075A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1075B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1075A Pump #1 Overtoad DEMO Control Relay Pump Control
Panel
YS-1075B Pump #2 Overload DEMO Control Relay Pump Control
Panel
--.--.....--- --
Station Instrument Index Report
08/131200105:43 PM
-
r..'
~
.-
PHASE
CONVERTER
~
-
~
PUMP
CONTROL
PANEL
ENCLOSURE
VALVE BOX
ACCESS
.-
DIRECTIONAL
ANTENNA
WET WELL
ACCESS
CUMANA
DR.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
~
o
"
w
o
"'
~
o
CITY Of" CORPUS CHRlsn
WASTEWATER DEPT.
1==11i11
ENGINEERING CORPORATION
JOB NO.: 1075
-
,.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1075 - CUMANA
DATE: 03/2000 SHEET 1 OF 3
CORPuS CHRISTI, IX. (361) 992-2284
[l PASO. TX (915) 534-9110
SAlT lAKE CITY,uT. (801)261-1455
SCALE: N.T.S.
DR: DAILEY
PROJECT NO. 7100
1
PUMP
CONTROL
PANEL
ENCLOSURE
L
1
1
1
1
RTU 1
PANEL
1
ALARM
RELAY
PANEL
1
1
HOA & TIMER 1
ENCLOSURE
J
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.2J ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
AND
o
o
1
REPAIR ALL HOLES IN PUMP CONTROL PANEL ENCLOSURE AND PUMP
CONTROL PANEL.
1
'"
~
o
N
o
"
w
o
~
~
o
1
1
1==11i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, TX. (361) 992-2284
n PASO, IX (gI5) 534-9110
SAlT LAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1075 - CUMANA
DATE: 03/2000 SHEET 2 OF 3
1
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
- -
It II Ii II C"",,"S ,"RISTO. T>. ('''1992-''84
II I Cl PASO, TIC (91!l) 534-9110
SALT LAKt CITY, UT. (1101) 261-1455
ENGINEERING CORPORATION
SERVICE
DISC.
'"
~
o
..;
o
"
w
o
"
~
o
JOB NO.: 1075
.
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISn
PROJECT NO. 7100
WASTEWATER OEPT.
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1075 - CUMANA
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
If
-
"f'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
STATION NO.
1077
SHARPSBURG
LIFT STATION
.. -, -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 077
SHARPSBURG
-
STATION TYPE: Lift Station: Wet well, (3) submersible pumps
ADDRESS: Up River Road / Sharpsburg Rd. LOCALE: North side of IH-37
SUBDIVISION: Calallen Area WASTEWATER PLANT: Allison
LATITUDE: N27051.695' LONGITUDE: W97036.777'
, PUMPS: (3) 50HP SERVICE VOLTAGE: 480V, 3PH, 3W
i INFLUENT PIPE(S): FORCE MAIN: 24" PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility with a walk-in type MCC enclosure housing the electrical
equipment. The station is accessed from a service driveway and is surrounded by a chain link security
fence. Vehicle access to the station is possible from one side.
Electrical service to the lift station is routed underground from an overhead service pole. The electric
meter is located on the MCC enclosure exterior. Control equipment consists of a Motor Control Center
(MCC), Pump Control Panel, RTU panel, and alarm relay panel. RTU panel is mounted on exterior of
MCC enclosure. Pump Control Panel and alarm relay panel are located in the MCC. Conduits are
rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with a pressure transducer level sensor interfaced through control relays
and a pump sequencing controller. Displacement type float switches are used as backup. Trouble
alarms are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 fl. - Azimuth: 129"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1077-1 High Level
1077-2 Main Power Failure
1077-3 Motor #1 & #2 Failure
1077-4 Motor #3 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- "
-
STATION NO: 1077
SHARPSBURG
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 13
ANALOG INPUTS: 1
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
JS-1077A Pump #1 Power Failure EXISTING Phase Failure Monitor Starter Cubicle DI ...~
Relay
JS-10778 Pump #2 Power Failure EXISTING Phase Failure Monitor Starter Cubicle DI
Relay
JS-1077C Pump #3 Power Failure EXISTING Phase Failure Monitor Starter Cubicle DI
Relay
JS-1077X Main Power Failure NEW Phase Failure Monitor MCC DI
Relay
JS-1077Y Pump CtrI Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coli) Panel
JS-1077Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1077A 1st Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LS-10778 2nd Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LS-1077C 3rd Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LSH-1077 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1077 Wet Well Low Level EXISTING Float Switch Pump Control AI Intrinsically safe barrier relay
Panel required
XS-1077A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
.
XS-10778 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-1077C Pump #3 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1077A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10778 Pump #2 Overtoad DEMO Control Relay Pump Control
Panel
YS-1077C Pump #3 Overtoad DEMO Control Relay Pump Control
Panel
. .
Station Instrument Index Report
08/13/200105:43 PM
.
I
T
DIRECTIONAL
ANTENNA
MOTOR
CONTROL
CENTER
WET WELL
AND VALVE
BOX ACCESS
AREA LIGHT
~
~
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
q
o
"
w
o
~
~
o
It II Ii II CORPuS CHRIST, TX. ('51) 99'-"84
'I I El PASO, TX (SlIS) 5l4-9110
So\lT WE CITY, UT. (801) 261-14~
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1077 - SHARPSBURG
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.
11
'"
UTILITY CO.
METER
1
MOTOR CONTROL
CENTER
1.
RTU
PANEL
1
1
1
J
1
.L
l
1
1
1
L
l
L
L
L
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
;-:;\ REPAIR ALL HOLES IN MOTOR CONTROL CENTER TO MAINTAIN THE NEMA
\J ENCLOSURE RATING.
It II Ii II CORPUS ""5", TX. (3<') 992-2'"
I tiEl PASO. TX (915) 534-9110
~T LAKE CITY, UT. (801) 261-14!l5
ENGINEERING CORPORATION
'"
~
o
N
o
"
w
o
~
~
o
JOB NO.: 1075
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1077 - SHARPSBURG
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
~
I'....
PUMP CONTROL
PANEL
~--^
.-
~
-
ALARM
RELAYS
-
~.
-
-
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAYS.
r-;\ REPAIR ALL HOLES IN MOTOR CONTROL CENTER TO MAINTAIN THE NEMA
~ ENCLOSURE RATING.
'"
~
o
..;
o
"
w
o
~
~
o
1==11i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI. TX. (361) !J92-2284
EL PASO. IX (915) 5.34-9110
SALT I..AK[ CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1077 - SHARPSBURG
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
~
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
....
....
,-
....
~
STATION NO.
1078
....
~
RAMOS
LIFT STATION
... -,.. -
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1078
RAMOS
-
~_.
i SUBDIVISION: Calallen Area
i LATITUDE: N27052.119'
-
I PUMPS: (2) 2HP
~-
I INFLUENT PIPE(S): 8"
i SERVICE VOLTAGE: 240/120V, 1 PH, 3W
I
i FO'RCiMAiN~4" PVC..---.....-----.
._______n________.J
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a cast-in.place concrete cap with no wall or fence. The station is located
adjacent to the street and does not have a service driveway or security fence. Vehicle access to the
station is possible from three sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on a plywood rack. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on the rack. All control
devices, including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Wood, 45 ft, Class 5 (New)
Antenna Mounting Elevation: 40 ft. - Azimuth: 1290
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1078-1 High Level
1078-2 Main Power Failure
1078-3 Motor #1 Failure
1078-4 Motor #2 Failure
1078-5 Motor Control Power Failure
1078-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet. doc
- ..
-
STATION NO: 1078
RAMOS
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
JS-1078X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1078Y Pump Ctri Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1078Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1078A 1 sl Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-10788 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1078 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSC:W78 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1078A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10788 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1078A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10788 Pump #2 Overload DEMO Control Relay Pump Control
Panel
.. . ~---"-
Station Instrument Index Report
08/13/2001 05:43 PM
-
-
-
-
PUMP UTILITY CO.
CONTROL METER
PANEL
SERVICE DISC.
WET WELL
ACCESS
It II Ii II CORPUS "RlSTI. TX. (361) "'-"84
II a PASO. TX (g15) 5J4-9110
SAlT LAK[ CI1Y, UT. (801) 261-1~55
ENGINEERING CORPORATION
o
o
'"
~
'"
o
"
w
o
'"
~
o
JOB NO.: 1075
- ..
STREET
REFLECTORS
RAMOS DR.
REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
CITY OF CORPUS CHRISn
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1078 - RAMOS
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
-
RTU
PANEL
1
1
1
ALARM
RELAY
PANEL
1
1
1
1
1
1
i
"
I
...
I
..L.
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2J ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
1
'"
~
N
o
"
w
o
'"
~
o
L
It lllill CORPUS CHRISTI, TX. ('&I) 992-"84
EL PASO. TX (91~) ~-9110
I t I SAlT LAKE ClJY, lIT. (801) 2&1-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
1
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1078 -'- RAMOS
DATE: 03/2000 SHEET 2 OF 3
DR: DAILEY
-
.....
.....
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
00
~
o
It II Ii II CORPUS ".STI. " (3<,) 99'."84
I t I [l PASO. TX (915) ~-9110
SAlT LAKE CITY, Uf. (801) 261-1..55
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1078 - RAMOS
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
I r
11
,~'
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
STATION NO.
1080
RESACA I BROADWAY
WWTP
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1080
RESACA I BROADWAY WWTP
I STATION TYPE: Lift Station: Wet well, Dry well, (2) vertical pumps ;
~ iLOCALE: Southeast of Resaca and Sam Ran'kin ..--.~
! ADDRESS: Broadway WWTP ; Streets
-".".__.__.._._.__._.,---~-~"--".__.__.__.._-_._._.__._---.----.-----;
, ,
I WASTEWATER PLANT: Broadway !
i SUBDIVISION: Broadway Treatment Plant
-
i LATITUDE: N27048.331,
~_.
I PUMPS: (2) 7.5HP
i-------.----
LINFLU~NT PIPE(S):
PHYSICAL DESCRIPTION:
_._.,.._._....._._-_._--~--_._._._.__._-_._.__._-----..,
J.:~.~~~TU~E:'!!.970~~~~~5' __.______._____...j
I SERVICE VOLTAGE: 480V, 3PH, 3W i
i- --.-.-.-.--.-.-...-..-.-.-.---.-----------------..-----~--------1
i FORCE MAIN:
.__._____._.____________L____.__._____.______________~_..u..............n...n__.._______...._______.......m......................................!
~
The lift station is an open air facility consisting of a below grade wet well and dry well structure. Lift
pumps are located in the dry well and the top of the structure is 2.5 feet above grade. The station is
located inside the Broadway WWTP. Vehicle access to the station Is possible from all sides.
Electrical service to the lift station is routed underground from an adjacent building. Control equipment
consists of a Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on
metal channel supports. All control devices, including pump motor starters, are located in the Pump
Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with a mechanical mercury switch level sensor interfaced through control
relays and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF
radio system.
ANTENNA SUPPORT:
Pole - Wood, 45 ft, Class 5 (New)
Antenna Mounting Elevation: 40 ft. - Azimuth: 1950
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1080-1 Wetwell High Level
1080-2 Main Power Failure
1080-3 Motor #1 Failure
1080-4 Motor #2 Failure
1080-5 Drywell High Level
1080-6 Motor Control Power Failure
1080-7 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1080
RESACA I BROADWAY WWTP
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 10
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
JS-1080X Main Power Failure NEW Phase Failure Monitor Pump Control 01 - ~.~.~.-
Relay Panel
JS-1080Y Pump Ctrl Pvvr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-1080Z RTU ClrI Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-1080A 1st Pump Start EXISTING Mechanical Sensor Pump Control DI Provide intrinsically safe barrier
Panel relay for future float switch
LS-10808 2nd Pump Start EXISTING Mechanical Sensor Pump Control 01 Provide intrinsically safe barrier
Panel relay for future float switch
LSH-1080 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSHH-1080 Dry Well High level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-1080 Wet Well Low Level EXISTING Mechanical Sensor Pump Control 01 Provide intrinsically safe barrier
Panel relay for future float switch
XS-1080A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10808 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1080A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10808 Pump #2 Overload DEMO Control Relay Pump Control
Panel
L.. -, .------- ._.-.-.----
Station Instrument Index Report
08/13/200105:43 PM
rr
~
rn
DRY WELL
ACCESS
WET WELL
ACCESS
-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
'"
o
"
w
o
o
'"
o
It II Ii II CORPUS ".ST'. TX. (361) 992-2'84
II I [l PASO, TX (915) 5J4-9110
~TlAK[Cl1Y.UT. (801)261-1455
ENGINEERING CORPORATION
CITY OF' CORPUS CHRISTI
WASTEWATER OEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1080 - RESACA BROADWAY WWTP
DR: DAILEY DATE: 03/2000 OF 3
RTU
PANEL
WET WELL
ACCESS
1
1
1
1
PUMP CONTROL
PANEL L
L
L
L
L
ALARM
RELAY
PANEL
L
I
I
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.2J ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
AND
l
It II Ii II CllRPVS ".S1< TX. ('51) 992-2'84
II I (L PASO, IX (915) 5~-91'O
SALT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
L
'"
~
o
N
o
"
w
o
o
'"
o
JOB NO.: 1 075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1080 - RESACA/SROADWAY WWTP
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
_ r _
~
IbBo
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
o
.,
o
1==11i11
ENGINEERING CORPORATION
CITY or CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRlST~ lX. (J61) 992-2284
rL PASO. IX (9'~) 5.)4-9110
SAlT lAKE CItY, uT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCITON PHOTOGRAPH
LIFT STA. 1080 - RESACA/BROADWAY WWfP
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
.
II
T'
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1081
TAMUCC
LIFT STATION
- - ~ .
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 081
TAMUCC
~
STATION TYPE: lift Station: Wet well, (2) submersible pumps
ADDRESS: 6300 Ocean Drive LOCALE: University Island (TAMUCC)
SUBDIVISION: Texas A&M CC WASTEWATER PLANT: Oso
LATITUDE: N27042.85T LONGITUDE: W97019.759'
PUMPS: (2) 20HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 12"PVC
~
PHYSICAL DESCRIPTION:
~
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap and is surrounded by a chain link security fence.
The station is accessed from a service driveway and is surrounded by a chain link security fence.
Vehicle access to the station is possible from one side.
Electrical service is routed from a pad mounted transformer. The electric meter and service
disconnect are located on the service pole. Control equipment consists of a Pump Control Panel, RTU
panel, and alarm relay panel. All enclosures are on service pole. All control devices, including pump
motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures
and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2790
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1081-1 High Level
1081-2 Main Power Failure
1081-3 Motor #1 Failure
1081-4 Motor #2 Failure
1081-5 Motor Control Power Failure
1081-6 24V Control Power Failure
1081-7 Minicas #1 Fail
1081-8 Minicas #2 Fail
08/13/01 5: 12 PM
Station Data Sheet.doc
.
.
STATION NO: 1081
TAMUCC
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 11
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
I/O
TYP COMMENTS
o
o
Pump Control .
JS-1081X Main Power Failure EX(STING Phase Failure Monitor DI
Relay Panel
JS-1081Y Pump Ctr1 Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1081Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1081A 1st Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-10818 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1081 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
-. New Junction Box Intrinsically safe barrier relay
LSL-1081 Wet Well Low level EXISTING Float Switch DI
required
XS-1081A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10818 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1081A Pump #1 Trouble EXISTING Mini CAS Unit Pump Control DI
Panel
YS-10818 Pump #2 Trouble EXISTING Mini CAS Unit Pump Control DI
Panel
YS-1081C Pump #1 Overload DEMO Control Relay Pump Control
Panel
------- -.
YS-1081D Pump #2 Overload DEMO Control Relay Pump Control
Panel
~._- L.....-_. I
Station Instrument Index Report
08/13/2001 05:43 PM
.
II'
T'
~
~
.-
WET WELL
ACCESS
DIRECTIONAL
ANTENNA
ELECTRIC SERVICE POLE
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
j;1
q
o
"
w
o
'"
o
1==11i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
PROJECT NO. 7100
WASTEWATER DEPT.
CORPUS CHRISTI, TX. (361) 992-2284
(L PASO, IX (91~) 534-9110
SAlT l.Al([ CllY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1081 - TAMUCC
DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
\.
.
.
j
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.2J ASSOCIATED SUPPORT HARDWARE.
r::\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
AND
1
1
1
J
1
1
1
1
1
1
1
1
i
PUMP
CONTROL
PANEL
ELECTRIC
SERVICE
POLE
UTILITY CO.
METER
RTU
PANEL
'"
~
o
N
o
"
w
o
'"
o
L
It II Ii II CORPUS "RlST>. TX. (3") "2-228'
II I El PASO, TX (915) ~-SIl10
SALT lAK[ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
1
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1081 - TAMUCC
DATE: 03/2000 SHEET 2 OF 3
DR: DAILEY
-
-
-
-
'"
~
o
..;
o
"
w
o
'"
o
1==11i11
ENGINEERING CORPORATION
JOB NO.: 1075
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2 REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CtTY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTl, IX. (J61) 992-2284
EL PASO, 1X (91:i) 5J4-91l0
SAlT lAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1081 - TAMUCC
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
~
~
STATION NO.
~
1082
CYNTHIA
LIFT STATION
--, -... -
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 082
CYNTHIA
STATION TYPE: Lift Station: Wet well, (2) submersible pumps I
ADDRESS: 5110 Cynthia LOCALE: Cynthia and River Lane
SUBDIVISION: Calallen Area WASTEWATER PLANT: Allison
LATITUDE: N27052.48T LONGITUDE: W97037.030'
PUMPS: (2)2HP SERVICE VOLTAGE: 240V, 1 PH, 3W
INFLUENT PIPE(S): (2) 8" FORCE MAIN: 4"PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a cast-in-place concrete cap with no wall or fence. The station is located
adjacent to the street and does not have a service driveway or security fence. Vehicle access to the
station is possible from one side.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on a plywood rack. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on the rack. All control
devices, including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC. Enclosures and conduits are In good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1310
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1082-1 High Level
1082-2 Main Power Failure
1082-3 Motor #1 Failure
1082-4 Motor #2 Failure
1082-5 Motor Control Power Failure
1082-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- ..
,.
-
STATION NO: 1082
CYNTHIA
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
JS-1082X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1082Y Pump Girl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1082Z RTU Gtrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS-1082A 1 st Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-10828 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1082 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
! LSL-1082 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1082A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10828 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1082A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10828 Pump #2 Overload DEMO Control Relay Pump Control
Panel
...
Station Instrument Index Report
08/13/200105:43 PM
-
-
SERVICE
DISC.
PUMP CONTROL
PANEL
UTILITY CO.
METER
WET WELL
ACCESS
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
r-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
~ ENCLOSURE RATING.
!e
o
o
"
w
o
N
<Xl
o
It lllill CORPUS <"RISTO. no. (361) 992-2'84
II I EL PASO. TX (915) 534-9110
SAlT LAKE CfTY. Ul. (SOl) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1082 - CYNTHIA
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
RTU
PANEL
ALARM
RELAY
PANEL
1
1
1
1
CYNTHIA DR. 1
1
1
1
1
1
1
1
(2) DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
1 ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1082 - CYNTHIA
DATE: 03/2000 SHEET 2 OF 3
'"
~
N
o
"
w
o
N
'"
o
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
CORPUS CttRlST1. TX. (361) 992-2284
[L PASO. IX (!lIS) 534-9110
SAlT lAKE erN, UT. (B01) 261-14~
ENGINEERING CORPORATION
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
1
1
1
L
PROJECT NO. 7100
L
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
!E
o
..;
o
"
w
o
N
.,
o
1=11 Ii II
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO, 7100
CORPuS CHRISTI, Tll (361) 992-2284
EL PASO. IX (iUS) 5J4-9110
SAlT lAK[ CllY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1082 - CYNTHIA
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
~
Wastewater Department
,.- Microwave Communication System
City of Corpus Christi
Project No. 7100
,.-
...
...
...
...
STATION NO.
1083
...
...
SUGAR TREE
LIFT STATION
- -"
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1083
SUGAR TREE
-
! STATION TYPE: Lift Station: Wet well, (2) submersible pumps
I LOCALE: West of Paul Jones Street
-_._---_._---_.._-~~--_._.._-_..__.._----_.._._._._._------
--J W~ST:~~~~R ~:~.~~..()so__.________
I LONGITUDE: W97019.463'
.._-,~._,._-----___.._..__._,__._._._._..__~_~___._._.._.__.__.____._...._..u_
i.~~_RVICE_~~:~~~.::_~40~1~~~:_3~~:.~!"._._.....,
I FORCE MAIN: i
_L____...__......._______...__..._....................._._...._.j
ADDRESS: 8050 South Padre Island Dr.
I SUBDIVISION: Hubler Tract
}.--..---....
-
LATITUDE: N27041.334'
i------.--
I PUMPS: (2) 20HP
i INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast.in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located inside the Sugar Tree apartment complex adjacent to the street and
does not have a service driveway or security fence. Vehicle access to the station is possible from two
sides.
Electrical service is routed underground to the lift station from local pad mounted transformers. The
electric meter and service disconnect are located on masonry wall. Control equipment consists of a
Pump Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the
masonry wall on metal strut support brackets. All control devices, including pump motor starters, are
located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in
good cond ition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole. Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. . Azimuth: 2930
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1083-1 High Level
1083-2 Main Power Failure
1083-3 Motor #1 Failure
1083-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
. r
I.
-
STATION NO: 1083
SUGAR TREE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
I/O
TYP COMMENTS
JS-1083X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-1083Y Pump Gtrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coli) Panel
JS-10832 RTU CtrI Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-1083A 1 st Pump Start EXISTING Float Switch New Junction Box DI 1~~trinsicaIlY safe barrier relay
required
LS-1083B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1083 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1083 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1083A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-1083B Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1083A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1083B Pump #2 Overload DEMO Control Relay Pump Control
Panel
----". ,__~~_______~L. .-
Station Instrument Index Report
08/13/2001 05:43 PM
-
~
OSO BAY
DIRECTIONAL
ANTENNA
VALVE BOX
ACCESS
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
o
"
w
o
'"
'"
o
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1083 - SUGAR TREE
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTl. TX. (361) 992-2284
EL PASO, TX (915) 534-9110
SAlT LAKE CITY, uT. (801) 261-1455
ENGINEERING CORPORATION
. r
111
f"'!
PUMP
CONTROL
PANEL
1
1
ALARM 1
PANEL
RELAY
1
RTU
PANEL
1
1
1
SERVICE
DISC.
1
J
WET WELL
ACCESS 1
1
1.
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2J ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
1
1
1;1
o
N
o
"
w
o
n
.,
o
1
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1083 - SUGAR TREE
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
1
CORPuS CHRISTI, TX. (361) 992-2284
n PASO, TX (915) 534-9110
SALT LAKE CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
- ,...
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
;0
o
..;
o
"
w
o
'"
~
1==1 Ii II
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPVS CHRISTI, TX. (361) 992-2284
[L PASO, TX (!illS) 534-9110
SALT lAKE CITY, UT. (801) 251-14~
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1083 - SUGAR TREE
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
.
f
..
~
Wastewater Department
._. Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
STATION NO.
1084
PARK ROAD 53
LIFT STATION
- . .~ '..0'...."
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1084
PARK ROAD 53
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
,
.-.-.---.---....
I ADDRESS: 11125 Park Road 53
i SUBDIVISION: Padre Island #1
i LOCALE: Park Road 53
~___m.___.___..__________.,___.__m_._._._m._._
I WASTEWATER PLANT: Whitecap
!
-
I LATITUDE: N27037.090' LONGITUDE: W97013.205'
._-----_._._-------~_._--_._-~----------_._-----------...-----..--,-........
i PUMPS: (2) 2HP I SERVICE VOLTAGE: 240/120V, 3PH, 4W
I I
[INFLUENT PIPE(S):""~8" pvc,4-"----lFORCE M~~N: 6" PV~.=~~~~~~=~~:~:
PHYSICAL DESCRIPTION:
_._......_....__-.J
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street and
does does not have a service driveway or security fence. Vehicle access to the station is limited due
to area landscaping, and other obstructions.
Electrical service is routed from an overhead service pole. The electric meter and service disconnect
are located on the service pole. Control equipment consists of a Pump Control Panel, RTU panel, and
alarm relay panel. All enclosures are on service pole. All control devices, including pump motor
starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3010
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1084-1 High Level
1084-2 Main Power Failure
1084-3 Motor #1 Failure
1084-4 Motor #2 Failure
1084-5 Motor Control Power Failure
1084-6 Float Control Failure
08/13101 5:12 PM
Station Data Sheet.doc
-
-
STATION NO: 1084
PARK ROAD 53
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1084X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-l084Y Pump Gtrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-1084Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS.l084A 1st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-l0848 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1084 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1084 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1084A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10848 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-1084A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10848 Pump #2 Overload DEMO Control Relay Pump Control
Panel
.- -_.__.~. -----_.._._-~----
Station Instrument Index Report
08/13/2001 05:43 PM
- ..
-
,....
DIRECTIONAL
ANTENNA
ELECTRIC SERVICE
POLE
-
-
-
VALVE BOX
ACCESS
-
MANHOLE
ROCK
GARDEN
WET WELL
ACCESS
PARK RD. 53
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
o
"
w
o
..
~
It lllill CORPUS CH""n. TX. (JOI) 99'."8<
II . [l PASO. TX (915) 534-9110
SAlT I..Al(E CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1084 - PARK ROAD 53
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
-
DIRECTIONAL
ANTENNA
RTU
PANEL
VENT
ELECTRIC
SERVICE
POLE
PUMP
CONTROL
PANEL
ALARM
RELAY
PANEL
WET WELL
ACCESS
o
o
DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
r:\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
'"
~
o
N
o
"
w
o
~
.,
o
1
1
i
L
i
1
1
1
1
1
1
1
1
1
1
1
It II Ii II CORPUS CHRIST'. lX. (361) 99'-'28'
II I n PASO, TX (915) 534-9110
SALT LAKE CITY, UT. (801) 261-145!1
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1084 - PARK ROAD 53
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
- -
L
-
FLOAT SWITCH
TERMINAL STRIP
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
~
'"
o
1==1 Ii II
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1084 - PARK ROAD 53
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRlSlI. lX. (361) 992-2284
[l PASO, TX (915) 534-9110
$.\1.T I.AlCE CITY, UT. (BOI) 261-1455
ENGINEERING CORPORATION
I
II
r
~
Wastewater Department
~ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
STATION NO.
1085
-'
LEEWARD
LIFT STATION
.. -.. - . -.....,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1085
LEEWARD
,
I STATION TYPE: Lift Station: Wet well. (2) submersible pumps
!
I ADDRESS: 14865 Running Light Street
,
I
i SUBDIVISION:
;
r-
i LATITUDE: N27036.456'
I LOCALE: Running Light and Leeward
i WASTEWATER PLANT: Whitecap
! ----.-....-............................. ..._.".,..__."-~-----~------_._."._..-
i LONGITUDE: W97012.668'
--"'-"'--'---.-.---'.'-""'1
,
I PUMPS: (2) 20HP
I
I INFLUENT PIPE(S): 24"
PHYSICAL DESCRIPTION:
SERVICE VOLTAGE: 240/120V, 3PH. 4W
....m.......__.____..___...;
I FORCE MAIN: 8"
I
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a cast-in-place concrete cap with no wall or fence. The station is located
adjacent to the street and is accessed from a service driveway. Vehicle access to the station is
possible from all sides.
Electrical service is routed underground to the lift station from local pad mounted transformers. The
electric meter and service disconnect are located on the rack. Control equipment consists of a Pump
Control Panel, RTU panel. and alarm relay panel. All enclosures are mounted on rack. All control
devices. including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Wood (Exist)
Antenna Mounting Elevation: 20 ft. - Azimuth: 302"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1085-1 High Level
1085-2 Main Power Failure
1085-3 Motor #1 Failure
1085-4 Motor #2 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
- ..
-
STATION NO: 1085
LEEWARD
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
..
JS-10B5X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
JS-10B5Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-10B5Z RTU ClrI Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-10B5A 1st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-l0B5B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-10B5 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
---_..------- --.- --
LSL-10B5 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-10B5A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
XS-10B5B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-10B5A Pump #1 Overload DEMO Control Relay Pump Control
Panel
I YS-10B5B Pump #2 Overload DEMO Control Relay Pump Control
Panel
.- - .-.
Station Instrument Index Report
08/1312001 05:43 PM
.
..
".
~
-
DIRECTIONAL
ANTENNA
UTILITY CO.
METER AND
SERVICE
DISC.
-
-
-
CHEMICAL
INJECTION
PUMP ENCL.
TRANSFORMER
WET WELL
ACCESS
VALVE BOX
ACCESS
RUNNING LIGHT DR.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
11
q
o
"
w
o
"'
'"
o
It II Ii II CORPUS "RISTO. TX. (3<'1992-228.
t 41 I EL PASO. TX (915) 5J4-91l0
SAlT LAKE CfIY, UT. (BOI) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1085 - LEEWARD
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
- ..
-
ALARM
RELAY
PANEL
LIGHT
POLE
DIRECTIONAL
ANTENNA
L
L
L
L
L
VALVE BOX
ACCESS
WET WELL
ACCESS
L
L
L
RTU
PANEL
PUMP CONTROL
PANEL
L
1
L
o
(3)
o
DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
I
....
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
L
1
'"
~
'"
N
o
"
w
o
~
'"
o
1
L
It II Ii II CORPUS C._SIl. IX. (3<1) 992-228'
II I [l PASO. IX (915) 534-9110
SAlT tAl((ClTY.UT. (801)261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1085 - LEEWARD
DATE: 03/2000 SHEET 2 OF 3
1
DR: DAILEY
.
I
".
F
-
FLOAT SWITCH
TERMINAL STRIP
-
-
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
'"
'"
o
1==1 Ii II
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1085 - LEEWARD
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, rx. (J61) 992-2284
EL PASO. TX (915) 534-9110
SAlT LAKE ClTY.UT. (801)261-1.55
ENGINEERING CORPORATION
DR: DAILEY
.
I
n
Wastewater Department
._ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
~.
STATION NO.
1086
FLOUR BLUFF
LIFT STATION
- . ~ .
r ~
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 086
FLOUR BLUFF
r'
I STATION TYPE: Lift Station: Wet well, (3) submersible pumps
I'ADDRESS: 1720 Flour Bluff Drive I LOCAl.:i~'~-S~~t;'-';-iPurd-~;----"-
-,--------+-----"-----~._."_._"--"-"----,-----"-"-----_._--_.-."-...---- .-- ~--------------------_.-
I WASTEWATER PLANT: Laguna Madre
- ---------------j
i SUBDIVISION: Major
'LATITUDE: N27039.305'
i LONGITUDE: W97018.528'
. .
. ,
, .
f-~----'-~---"-------------~---~---"----'----------'__...____m____...._....._._........__...__.....m__......."....---.-.------
i PUMPS: (3) 50HP I SERVICE VOLTAGE: 480V, 3PH, 3W
-
I INFLUENT PIPE(S):
i___~~_.___.____
i FORCE MAIN:
PHYSICAL DESCRIPTION:
The lift station is an open air facility with a walk-in type MCC enclosure housing the electrical
equipment. The station is accessed from a service driveway and is surrounded by a decorative
masonry wall and a chain link security fence. Vehicle access to the station is possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is located on enclosure exterior. Control equipment consists of a Motor Control Center
(MCC), Pump Control Panel, RTU panel, and alarm relay panel. RTU panel is mounted on exterior
wall inside an expanded metal cage type security enclosure. Pump Control Panel and alarm relay
panel are located in the MCC. Conduits are rigid or flexible PVC. Enclosures and conduits are in
good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3050
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1086-1 High Level
1086-2 Main Power Failure
1086-3 Motor #1 & #2 Failure
1086-4 Motor #3 Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1086
FLOUR BLUFF
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 11
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
JS-1086X Main Power Failure NEW Phase Failure Monitor MCC DI --
Relay
JS-1086Y Pump Ctrl Pwr Failure NEW Control Relay (120 VAC MCC DI
coil)
JS-1086Z RTU Ctrl Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-1086A 1st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1086B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1086C 3rd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1086 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1086 Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
XS-1086A Pump #1 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
XS-1086B Pump #2 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
XS-1086C Pump #3 Run Status NEW Motor Starter N.D. Aux MCC Motor DI
Contact Starter
YS-1086A Pump #1 Overload DEMO Control Relay MCC Motor
Starter
r' .- ~~...- r--~
YS-1086B Pump #2 Overload DEMO Control Relay MCC Motor
Starter
YS-1086C Pump #3 Overload DEMO Control Relay MCC Motor
Starter I
_n_..___.. .".~-
Station Instrument Index Report
08/13/200105:43 PM
DIRECTIONAL
ANTENNA
FLOUR BLUFF DR.
-
-
MCC
ENCL.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
~
o
"
w
o
'"
"'
o
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1086 - FLOUR BLUFF
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
[L PASO, lX (91:i) 5)4-9110
SALT l.AI([ CflY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
J
RTU
PANEL
MCC ENCLOSURE
1
1
1
PUMP
CONTROL
PANEL
I
-
1
XFMR.
1
1
ALARM
RELAY
PANEL
.1
1
J
J
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
o DISCONNECT ALARM WIRING AND REMOVE ALARM RELAYS.
1
'"
~
o
N
o
"
w
o
'"
'"
o
1
It II Ii II CORPUS "RISTO. TX. (3<,) 992-228'
II I [L PASO, IX (915) ~-9110
WT LAKE CITY UT. (801) 261-14~
ENGINEERING CORPORATION .
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
1.
1.
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1086 - FLOUR BLUFF
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
~
~
~
ALARM
RELAYS
'"
~
o
..;
o
"
w
o
'"
"'
o
1==11i11
ENGINEERING CORPORATION
JOB NO.: 1075
. "
I
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI, IX. (J61) 992-2284
n PASO, TX (915) 534-9110
SAlTL.AKEClTY,UT. (801)261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1086 - FLOUR BLUFF
DATE: 03/2000 SHEET 3 OF 3
SCALE: N.T.S.
DR: DAILEY
1"'
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
~
STATION NO.
1087
KING'S CROSSING
LIFT STATION
-.~ . I "_.
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 087
KING'S CROSSING
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
____.....___m.............__..._.______________.___._._.__.______.___ _________._______._._<
! LOCALE: Cimarron and Lens Dr.
i
! ADDRESS: 8201 Cimmaron Blvd.
I SUBDIVISION: King's Crossing
f-.
l';:;/;'STEWA TERPLANT~..O~~..-.-
..--1.................... .----....-.---.-..-- .....................
i LONGITUDE: W97023.473'
i
i LATITUDE: N27038.755'
------_..__._-_._._.._--_.__.__._.._._..,._._._.__._-~---..-.-.....- .............--...........--........--.
i SERVICE VOLTAGE: 240/120V, 3PH, 4W
__.____.__.-+____________________~_._____..____._._..__..,u....u..___n___
i FORCE MAIN:
i PUMPS: (2) 7.5 HP
i INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street with a service driveway and no security fence.
Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the iift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. . Azimuth: 3400
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1087-1 High Level
1087-2 Main Power Failure
1087-3 Motor #1 Failure
1087-4 Motor #2 Failure
1087-5 Motor Control Power Failure
1087-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet doc
-
-
STATION NO: 1087
KING'S CROSSING
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
.
JS-1087A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-1087B Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-1087X Main Power Failure NEW Phase Failure Monitor Pump Control DI
Relay Panel
- Pump Gtrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
JS-10B7Y
coli) Panel
JS-1087Z RTU Gtrl Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-1087A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-1087B 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay --
required
LSH-1087 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSL-1087 Wet Welf Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
. Motor Starter N.D. Aux Pump Control DI
XS-1087A Pump #1 Run Status NEW
Contact Panel
XS-1087B I Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
I Contact Panel
YS-1087A 1_ Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10878 . _.-._--- ---~----
Pump #2 Overload DEMO Control Relay Pump Control ...J
Panel
------, ...
Station Instrument Index Report
08/13/200105:43 PM
.
r
r
~
DIRECTIONAL
ANTENNA
SERVICE
~
UTILITY CO.
METER AND
SERVICE DISC.
LENS DR.
CIMMARON BLVD.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
~
o
"
w
o
~
.,
o
It II Ii II CORPUS ".511. T~ (J6IJ 99'-228'
II I n PASO, TX (915) 534-9110
$.\1.1 LAKE CITY, Uf. (801' 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1087 - KING'S CROSSING
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.
.
-
J
RTU
PANEL
PUMP CONTROL
PANEL
1
1
1
1
1
1
1
1
J
1
J
J
J
ALARM
RELAY
PANEL
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2J ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3..; ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
~
N
o
"
w
o
~
'"
o
1
L
It II Ii II CORPUS CH'.". TX. (3<') 992-2'84
II I [L PASO. tx (915) 5)4-9110
WT lAKE CITY. Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRlSn
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1087 - KING'S CROSSING
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
J
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1087 - KING'S CROSSING
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
!i
'"
..;
o
"
w
o
~
"'
o
It II Ii II CORl'VS "RIST'. TX. (J6I) 99'-"84
I tiEL PASO, TX (915) 534-9110
SAlT LAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
.
I'
FLOAT SWITCH
TERMINAL STRIP
PROJECT NO. 7100
"
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1088
GATEWAY PARK
LIFT STATION
.. . ~ .., ,~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 088
GATEWAY PARK
I STATION TYPE: lift Station: Wet well, (2) submersible pumps
i ADDRESS: 1143 Laguna Shores
i LOCALE: Next to Flour Bluff Fire Station
SUBDIVISION:
I LATITUDE: N27039.80T
i WASTEWATER PLANT: Laguna Madre
..--"-.."_._.._._..__.._.._______.~_._._.._.,...,._.___.__~__________.__._...._n.."..__.__._____..__-;
i LONGITUDE: W97016.560'
;_______.___.__n_________._
, .
. .
.....--.".............-----.--------....................-.-----------_._"._-_.__..,.~_._._----------_._-~
. .
!PU~PS: (2) 2HP
i INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
i SERVICE VOLTAGE: 240/120V, 1PH, 3W
---.--.-~-----------___,--.-.-.--.,.-._.._-_-_-__-_-_--__..__.......n__..._.________...__n___...__.....n..".__...j
,
i FORCE MAIN:
i____________'_..'_m.'.."._._..__,___~______.__.__.._.__.___~__._.__..__...__._.,..._,__._._._.._...._.._J
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-In-place concrete cap which is surrounded by a decorative masonry
block wall. The station is accessed from a service drive. Vehicle access to the station is possible
from one side.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on a metal strut rack.
All control devices, including pump motor starters, are located in the Pump Control Panel. Conduits
are rigid or flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 2960
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1088-1 High Level
1088-2 Main Power Failure
1088-3 Motor #1 Failure
1088-4 Motor #2 Failure
1088-5 Motor Control Power Failure
1088-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet. doc
.
.
STATION NO: 1088
GATEWAY PARK
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
.-.-...- - -_.
JS-1088X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-1088Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-1088Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-1088A 1st Pump Start EXISTING Float Switch New Junction Box 01 1~~trinsicaIlY safe barrier relay
required
LS-10888 2nd Pump Start EXISTING Float Switch New Junction Box 01 1~~trinsicallY safe barrier relay
required
LSH-1088 Wet Well High Level EXISTING Float Switch New Junction Box 01 1~~trinsicaIlY safe banier relay
required
. EXISTiNG -.-~----~- _. -_.,-
LSL-1088 Wet Well Low Level Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-1088A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
XS-10888 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
YS-1088A Pump #1 Overload DEMO Control Relay Pump Control !
Panel
YS-10888 Pump #2 Overload DEMO Control Relay Pump Control ,
Panel ,
---~ ~._.._-~ ~~ _._~ ,
Station Instrument Index Report
08/13/2001 05:43 PM
-
-
"
69KV OVERHEAD
POWER POLES
ELECTRIC
SERVICE
POLE
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
"!
o
"
w
o
"'
1l
It II Ii II CORPUS CH.SIl. TX. (JOI) 992-228.
t I I [L PASO, TX (91~) 534-9110
SAlT tAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PRauECl NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1088 - GATEWAY PARK
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
-
-
""
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1088 - GATEWAY PARK
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
ALARM
RELAY
PANEL
RTU
PANEL
WET WELL
ACCESS
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\2.; ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
'"
~
o
N
o
"
w
o
m
m
o
1==1 Ii II
CITY or CORPUS CHRISTl
WASTEWATER DEPT.
CORPUS CHRISTI. TX. (361) ~2-22B4
El PASO. TlI (915) ~-9110
SAlT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
SCALE: N.T.S.
L
1
1
1
1
PUMP CONTROL
PANEL i
1
1
L
1
1
1
AND
1
1
1
1
PROJECT NO. 7100
1
~
~
~
~
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
"
"
o
1==11i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPlIS CHRISTl. TX. (J61) 992-2284
tL PASO. lX (915) 534-9110
s.\L.T lAKf CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1088 - GATEWAY PARK
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
-
Wastewater Department
._ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
STATION NO.
1089
LAKE PADRE-SOUTH
LIFT STATION
... ..... I
..,.
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 089
LAKE PADRE-SOUTH
~
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 14501 Whitecap Blvd. LOCALE: East of Park Road 53
SUBDIVISION: WASTEWATER PLANT: Whitecap
LATITUDE: N27036.09T LONGITUDE: W97013.213'
PUMPS: (2) 20HP SERVICE VOLTAGE: 480V, 3PH, 3W
INFLUENT PIPE(S): FORCE MAIN: 8"PVC
-
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a masonry block wall. The
station is located adjacent to the street is accessed from a service driveway. Vehicle access to the
station is possible from one side.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter is located on the service pole and service disconnect is mounted on the lift station masonry wall.
Control equipment consists of a Pump Control Panel, RTU panel, and alarm relay panel. All
enclosures are mounted against the masonry wall on metal strut support brackets. All control devices,
including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible
PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 305"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1089-1 High Level
1089-2 Main Power Failure
1089-3 Motor #1 Failure
1089-4 Motor #2 Failure
1089-5 Motor #3 Failure
1089-6 Motor Control Power Failure
1089-7 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet. doc
. r
II
~
STATION NO: 1089
LAKE PADRE-SOUTH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
JS-1089X Main Power Failure NEW Phase Failure Monitor Pump Control .-...-
01
Relay Panel
JS-1089Y Pump Ctrt Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-1089Z RTU CtrI Pwr Failure NEW 120V AC Digital Input RTU Panel 01
LS-1089A 1st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-10898 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-1089 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL-1089 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-1089A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-10898 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-1089A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-1089B Pump #2 Overload DEMO Control Relay Pump Control
Panel
._-
Station Instrument Index Report
08/13/2001 05:43 PM
. r
II
r"'1
DIRECTIONAL
ANTENNA
WET WELL
ACCESS
~.
~,
-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
o
"
w
o
0>
.,
o
It II Ii II CORI'\JS CHRIST'. TX. (J") 992-228'
II I El PASO. TX (915) 534-9110
SAlT lAKE CITY, Uf. (801) 261-1455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER OEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1089 - LAKE PADRE SOUTH
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.
1"1
-
J
RTU
PANEL
SERVICE
DISC.
PUMP
CONTROL
PANEL
J
XFMR.
J
J
J
J
ALARM
RELAY
PANEL
WET WELL J
ACCESS
1
1
1
1
1
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2J ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
1
1
'"
~
o
N
o
"
w
o
'"
~
J
It II Ii II CORPUS "RISTI. lX. C3<') 992-"84
II I El PASO, TX (915) 534-9110
SAlT tAl([ CITY, LfT. (801) 251-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
J
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1089 - LAKE PADRE SOUTH
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
~
FLOAT SWITCH
TERMINAL STRIP
~
~
~
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
'"
~
o
..;
o
"
w
o
m
.,
o
It II Ii II CORPUS CHRIST'. TX. (J6\) 99'-'28'
II I n PASO, TX (915) 5~-9110
SAlT tAl([ CITY, UT. (a01) 261-14~
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1089 - LAKE PADRE SOUTH
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
-
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
-
STATION NO.
1090
-
-
PORT & PEARSE
LIFT STATION
. ~ .
,..
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1090
PORT & PEARSE
, STATION TYPE: Lift Station: Wet well, (6) submersible pumps
i ADDRESS: Pearse Street
... .._--~
! LOCALE: Port Ave. and Pearse Street
--------------------------- .._........._m__......._."...._ "-"" ." -,.- - - - -- - ------,.".'1
! WASTEWATER PLANT: Oso
.._.............._~"._"--------;
, SUBDIVISION:
LATITUDE: N27045.259'
i LONGITUDE: W97025.152'
!
,
,--
,
I SERVICE ~~':.~AG_E:..~~~~:~~~.:.~~____.._____.
i PUMPS: (2) 25HP, (4) 77HP
i INFLUENT PIPE(S):
I FORCE MAIN: 14" DIP
-------------j
PHYSICAL DESCRIPTION:
The lift station is a prefabricated metal building housing the electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Vehicle access to
the station is possible from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. The
electric meter is located on building exterior. Control equipment consists of a Motor Control Center
(MCC), Pump Control Panel, RTU panel, and alarm relay panel. PLC based Pump Control Panel,
RTU panel, and alarm relay panel are located in the MCC. Conduits are rigid or flexible PVC.
Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through a PLC. Trouble
alarms are currently reported through the UHF radio system. NOTE: Existing PLC is not to be
communicated with.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 190"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1090-1 High Level
1090-2 Main Power Failure
1090-3 Motor #1 Failure
1090-4 Motor #2 Failure
1090-5 Motor #3 Failure
1090.6 Motor #4 Failure
1090-7 Motor #5 Failure
1090-8 Motor #6 Failure
1090.9 Motor Control Power Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1090
PORT & PEARSE
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 17
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
JS.l090A Pump #1 CtrI Pwr Failure DEMO Control Relay ...
Alarm Relay Panel
JS.1090B Pump #2 Ctrt Pwr Failure DEMO Control Relay Alano Relay Panel
JS.1090C Pump #3 Ctrl Pwr Failure DEMO Control Relay Alarm Relay Panel
JS-l090D Pump #4 CtrI Pwr Failure DEMO Control Relay Alarm Relay Panel
JS-l090E Pump #5 Ctrl Pwr Failure DEMO Control Relay Alarm Relay Panel
JS.1090F Pump #6 Ctrl Pwr Failure DEMO Control Relay Alarm Relay Panel
JS-l090X Main Power Failure EXISTING Phase Failure Monitor MCC Di ~-
Relay
JS-l090Y Pump PLC ClrI Pwr EXISTING Control Relay PLC Control Panel DI
Failure
JS-l090Z RTU Ctrl Pwr Failure NEW 120VAC Di9itallnput RTU Panel DI
LS-l090A 1 st Pump Start EXISTING Float Switch I Pump Control DI Intrinsically safe barrier relay
Panel required
LS-l090B 2nd Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required i
LS-l090C 3rd Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay ~
Panel required
LS.1090D 4th Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LS-l090E I 5th Pump Start EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
I ! Panel required
LS-1090F 6th Pump Start EXISTING I Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LSH-l090 Wet Well High Level EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
LSL-l090 Wet Well Low Level EXISTING Float Switch Pump Control DI Intrinsically safe barrier relay
Panel required
XS-l090A Pump #1 Run Status NEW Motor Starter N.Q. Aux MCC Starter DI
Contact Cubicle
XS-l090B Pump #2 Run Status NEW Motor Starter N.O. Aux MCC Starter DI
Contact Cubicle
XS.1090C Pump #3 Run Status NEW Motor Starter N.O. Aux MCC Starter DI
Contact Cubicle
XS-1090D Pump #4 Run Status NEW Motor Starter N.O. Aux MCC Starter DI
Contact Cubicle
XS-l090E Pump #5 Run Status NEW Motor Starter N.D. Aux MCC Starter DI
Contact Cubicle
XS-l090F. Pump #6 Run Status NEW Motor Starter N.D. Aux MCC Starter DI
___L L. Contact Cubicle
. ----
Station Instrument Index Report
08/13/2001 05:43 PM
.
.
.,.
WET WELL
ACCESS
DIRECTIONAL
ANTENNA
CHEMICAL
TANK
G REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
L>
,.
~
o
:>
w
o
o
'"
o
1:111i11
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1090 - PORT & PEARSE
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, TX. (J6I) 992-2284
[l PASO. TX (915) 534-9110
SAlT lAKE CITY, UT. (SOl) 261-'455
ENGINEERING CORPORATION
JOB NO.: 1075
SCALE: N.T.S.
MCC
.
L
L
L
L
L
L
L
L
L
L
L
L
L
L
0-0
...
RTU AND .
ALARM
RELAYS iii
10 DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
~ ALARM RELAYS FROM CUBICLE.
It II Ii II CORP\JS CHlo,n. ". (361) 992-228'
II I EL PASO, TX (915) 534-9110
SAlT l..Al([ CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
1
L
PROJECT NO. 7100 I
1
!
"
~
o
....
o
:0
w
o
o
..
o
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1090 - PORT & PEARSE
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
~
~
1. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
C>
"
<:>
n
<:>
~
w
<:>
<:>
m
<:>
1:11 Ii II
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPIJS CHRISTI, IX. (361) 992-2284
n PASO. 1X (915) 5;}t-9110
SALT LAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1090 - PORT & PEARSE
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
-
~
STATION NO.
1091
SEA PINES
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 091
SEA PINES
-
i PUMPS: (2) 10HP
~~~--
ll~~LUENT PIPE(S): 8"
PHYSICAL DESCRIPTION:
i
,
;
iLoCALI~~ W~~~l ofP;~kR~;d'2-2 ...........1
;----.-.--.-..-..-...-..--.-.------.--~----------.--.-----------------------------1
I WASTEWATER PLANT: Whitecap I
--.--f---~-----~------,.._----.,.-._.-.-.--.,.-..---.-.--........--.......----....----...---.--.----...---j
i LONGITUDE: W97013.924' ,
.. I
i------------.-----n..-.-.....-n--.----.-----.-----....-.---.--.-----~----~l
i SERVICE VOLTAGE: 240/120V, 3PH, 4W i
,..............---...----.....-...--...-....................................... ................_._.._~
I FORCE MAIN: 6" PVC I
!......................__..___._..~...~..~..~_....._.. ...........................J
-
i STATION TYPE: Lift Station: Wet well, (2) submersible pumps
[---.
-
i ADDRESS: 14192 Sea Pines Dr.
I SUBDIVISION:
LATITUDE: N27035.075'
-
-
The lift station is an open air facility consisting of a below grade wet well with submersible pumps.
The wet well is topped with a precast concrete cap. The station is accessed from a service driveway
and does not have a security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground to the lift station from local pad mounted transformers. The
electric meter and service disconnect are located on the rack. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted on rack. All control
devices, including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
-
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. . Azimuth: 310"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1091-1 High Level
1091.2 Main Power Failure
1091-3 Motor #1 Failure
1091-4 Motor #2 Failure
1091-5 Motor Control Power Failure
1091-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1091
SEA PINES
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS; 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
JS.l091X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l091Y Pump Ctrt Pwr Failure NEW Control Relay (120 VAC Pump Control DI
coil) Panel
JS.1091Z RTU Ctrt Pwr Failure NEW 120VAC Digital Input RTU Panel DI
LS.l091A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS.l0918 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH.l091 Wet Well Hi9h Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
------ -......--- EXISTING ._~-~._..- . -- -'DI
LSL.l091 Wet Well Low Level Float Switch New Junction Box Intrinsically safe barrier relay
required
XS-1 091 A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
XS-10918 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control DI
Contact Panel
YS-1 091 A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-l0918 Pump #2 Overload DEMO Control Relay Pump Control
I Panel
---.-.---- -.- -. ----,--_.-
Station Instrument Index Report
08/13/200105:43 PM
t
f
r
-
-
DIRECTIONAL
ANTENNA
WET WELLL
ACCESS
-
-
-
TRANSFORMER
VALVE
BOX
ACCESS
-
~
SEA PINES
DRIVE
MANHOLE
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
,.
"
o
:>
w
c
'"
c
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1091 - SEA PINES
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI. Tx. (361) 992-2284
[L PASO, tx (91!l) 534-9110
SALT lAJ(( CItY, UT. (801) UI-1455
ENGINEERING CORPORATION
DR: DAILEY
.
I.
-
RTU
PANEL
J
1
1
1
1
1
PUMP CONTROLl
PANEL
TRANSFORMER
WET WELL
ACCESS
ALARM
RELAY
PANEL
/""":\ DiSCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
0)
o
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
"'
"'
"
'"
"
"
~
"
0>
"
11111i II C<IOPUS CHRJSTI. TX. (J6I) 992-228'
II I ELPASO,TX (915)534-9110
SAlT lAKE CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1091 - SEA PINES
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
I
r
.,
IT
1
1
J
1
1
1
1
1
1
1
-
,-
FLOAT SWITCH
TERMINAL STRIP
~.
-
-
-
-
-
<.
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
<>
;0
"
..;
"
"
w
c
'"
"
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI. Tx. (361) 992-2284
EL PASO, TIC (915) 534-9110
WT lAKE CI1Y, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1091 - SEA PINES
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
..
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~
-
-
-
-
STATION NO.
1092
COQUINA BAY
LIFT STATION
- ~ - . -" , ,.,...,-.'-~'-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 092
COQUINA SAY
.---
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
t ..-.--.-..-.-.----~-------~--~-~--.-.-.--...,.-.--..,..-.,.....--..--.--
I ADDRESS: 13921 Sea Pines Blvd. I LOCALE: West of Park Road 22
i I_.___,.._..,.__________________~____._._._.._._..__.._._...... ....n__n_...........__..... ..........._._.___n_
~UBDIVISION: Coquina Bay 1~~.~~_~~~!E~_~'=~N~~~hi~e~~p..........___m)
I LATITUDE: N27035.248' I LONGITUDE: W97014.226'
I ,
r---'--'-'.- ---.
i PUMPS: (2) 5HP
L_
! INFLUENT PIPE(S):
I SERVICE VOLTAGE: 480V, 3PH, 3W
,
_....__'.........__."........_............................................ ______._.__.________n__
I FORCE MAIN: 6" PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. The station is accessed from a service driveway
and does not have a security fence. Vehicle access to the station is possible from all sides.
Electrical service is routed underground. The electric meter and service disconnect are located on the
service pole. Control equipment consists of a Pump Control Panel, RTU panel, and alarm relay panel.
All enclosures are on service pole. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and conduits are in good
condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. . Azimuth: 310"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1092-1 High Level
1092-2 Main Power Failure
1092-3 Motor #1 Failure
1092-4 Motor #2 Failure
1092-5 Motor Control Power Failure
1092-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet. doc
STATION NO: 1092
COQUINA BAY
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
Phase failure Monitor Pump Control -~,~
JS-l092X Main Power Failure NEW DI
Relay Panel
JS.l092Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control DI
coil) Panel
JS-l092Z RTU Ctrt Pwr Failure NEW 120V AC Digital Input RTU Panel DI
LS-l092A 1 st Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LS-l0928 2nd Pump Start EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
LSH-1092 Wet Well High Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay
required
Wet Well Low Level EXISTING Float Switch New Junction Box DI Intrinsically safe barrier relay --
LSL-l092
required
XS-l092A Pump #1 Run Status NEW Molor Starter N.O. Aux Pump Control DI
Contact Panel
XS-l0928 Pump #2 Run Status NEW Motor Starter N.O. Aux Pump Control DI
Contact Panel
YS-l092A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-l0928 Pump #2 Ove~oad DEMO Control Relay Pump Control
Panel
-
Station Instrument Index Report
08/13/2001 05:43 PM
.
I
T
-
DIRECTIONAL
ANTENNA
WET WELL
ACCESS
-
SEA PINES DR.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
~
"
"
w
"
N
'"
"
II II Ii II COR!'US CHRISTI. TX. (361) 99""84
II I n PASO. TX (915) 534-9110
~T lAJ(( CItY Uf. (801) 261-1455
ENGINEERING CORPORATION '
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE; N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1092 - COQUINA BAY
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
-
..
..
DIRECTIONAL
ANTENNA
RTU
PANEL
ALARM
RELAY
PANEL
1
L
L
L
L
L
PUMP CONTROL
PANEL L
L
l
l
L
L
AND
L
I
~
L
L
PROJECT NO. 7100 '
!":\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
~ ASSOCIATED UNISTRUT SUPPORTS.
DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
ASSOCIATED UNISTRUT SUPPORTS.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1092 - COQUINA BAY
DATE: 03/2000 SHEET 2 OF 3
(3)
o
REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
ENCLOSURE RATING.
'-'
'"
o
'"
o
:>
w
o
N
'"
o
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
CORPuS CHRISTI. lX. (361) 992-2284
n PASO. TX (gIS) 534-9110
SAlT lAK[ erN, UT. (801) 261-1455
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
.
r
l
T
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTiNG ALARM WIRiNG.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
~
o
..;
o
:>
w
o
N
'"
o
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7tOO
CORPUS CHRISTI. TX. (361) 992-2284
EL PASO. TX (915) ~-9110
SAlT lAKE CITY. UT. (801) 261-1<455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1092 - COQUINA BAY
DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
-
.
..
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
STATION NO.
1093
COASTAL MEADOWS
LIFT STATION
. . f ., ... ". .,. "".,..,
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1093
COASTAL MEADOWS
! STATION TYPE: Lift Station: Wet well, (2) submersible pumps
!ADDRESS: 6868 Old Brownsville Road i LOCALE:"" North of Sarat~~~'BI~d:-.._m
i. ____.,_.,._.__,._.___.~__~__._."..__._.___.,._.._...._..__. .mm........................
;
[ WASTEWATER PLANT: Greenwood
i _ _ ..__..._............_. .............__.._..________
i LONGITUDE: W97029.111'
, ..__._...._.._....._...._-_.._._~-_.-......
I
--t~~~~~.~~.~~~:~~~c~OV, ~~~~.~~ ....... ... ..........
SUBDIVISION:
! LATITUDE: N27044.222'
i PUMPS: (2) 10HP
i INFLUENT PIPE(S): 10"
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast.in-place concrete cap that is 18-inches above grade. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Vehicle access
around the wet well structure is limited.
Electrical power is obtained from an overhead electrical service. Control equipment consists of a
Pump Control Panel, RTU panel, and alarm relay panel. All enclosures, including electric meter and
service disconnect, are mounted on the service pole. All control devices, including pump motor
starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole. Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 100"
EXISTING STATION ALARMS:
.-
ALARM NO DESCRIPTION
1093-1 High Level
1093-2 Main Power Failure
1093.3 Motor #1 Failure
1093-4 Motor #2 Failure
1093-5 Motor Control Power Failure
1093-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
-
STATION NO: 1093
COASTAL MEADOWS
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
--,.------- -~. --.-
JS-l093X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-1093Y Pump Girl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS.1093Z RTU CtrI Pwr Failure NEW 120V AC 019ital Input RTU Panel 01
LS-l093A 1st Pump Start EXISTiNG Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-l0938 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH.l093 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
------
LSL-l093 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l093A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l093B Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-l093A Pump #1 Overload DEMO Control Relay i Pump Control
Panel
YS-l0938 Pump #2 Overload DEMO Control Relay I Pump Control
Panel
_n___ _ __ __ -----~-- --------------.-.-._-,-._-----.
Station Instrument Index Report
08/13/200105:43 PM
-
.
-
ELECTRIC
SERVICE
POLE
DIRECTIONAL
ANTENNA
-
=~,*
UTiLITY CO.
METER
OLD
BROWNSVILLE
ROAD
SERVICE DISC.
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
<>
,.
q
o
"
w
o
'"
m
o
I, II Ii II CORPUS CHOST.. T<. ('61) 992-2'"
II tiEL PASO, TIC (915) ~-gI10
SAlT LAKE CITY, lIT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY OF CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1093 - COASTAL MEADOWS
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
-
-
"
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1093 - COASTAL MEADOWS
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
TRANSFORMER
WET WELL
ACCESS
r:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3../ ASSOCIATED UNISTRUT SUPPORTS.
(;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
"
'"
o
N
o
:>
~
o
,..,
'"
o
It II Ii II CORP\JS CHRISTI. TX. (361) 992.228.
[l PASO, IX (gIS) 5)4-Qll0
It I SAlTLAK[CITYUT.(801)261-1455
ENGINEERING CORPORATION .
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.T.S.
1
1
1
RTU
PANEL
1
1
1
PUMP
CONTROL
PANEL
1
1
ALARM
PANEL
RELAY
1
J
L
AND
1
1
I
L
L
PROJECT NO. 7100
l
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
"
~
"
n
"
:0
w
"
n
'"
"
1::11i11
ENGINEERING CORPORATION
CITY Of" CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTl, lX. (J61) 992-2284
(L PASO. TX (915) 5J4-9110
SALT I..AKf CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1093 - COASTAL MEADOWS
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
JOB NO.: 1075
SCALE: N.T.S.
Wastewater Department
__ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1094
DEDIETRICH
LIFT STATION
. I r ~
"
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1094
DEDIETRICH
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 150 McKinzie Road LOCALE: North of State Hwy. 44
SUBDIVISION: WASTEWATER PLANT: Allison
LATITUDE: N27047.145' LONGITUDE: W97034.297'
PUMPS: (2) 10HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 10" FORCE MAIN: 8"PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street and
is accessed from a service driveway. Vehicle access to the station is possible from all sides.
Electrical service is routed from an overhead service pole. The electric meter and service disconnect
are located on the service pole. Control equipment consists of a Pump Control Panel, RTU panel, and
alarm relay panel. All enclosures are on service pole. All control devices, including pump motor
starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 114"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1094.1 High Level
1094-2 Main Power Failure
1094.3 Motor #1 Failure
1094.4 Motor #2 Failure
1094-5 Motor Control Power Failure
1094-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1094
DEDIETRICH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS.l094X Main Power Failure NEW Phase Failure Monitor Pump Control 01 I
Relay Panel
JS-l094Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS.1094Z RTU Ctrt Pwr Failure NEW 120V AC Oigilallnput RTU Panel 01
LS-l094A 1st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-l0948 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-l094 Wet Well High level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
.'.'-.'- _.---- ----
LSL-l094 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS.1094A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-10948 Pump #2 Run Status NEW Motor Starter N.Q. Aux Pump Control 01
Contact Panel
YS.l094A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-10948 Pump #2 Overload DEMO Control Relay Pump Control
Panel
---
Station Instrument Index Report
08/13/200105:43 PM
. !"
I.
-
DIRECTIONAL
ANTENNA
SERVICE
VALVE BOX
ACCESS
WET WELL
ACCESS
McKiNZIE
ROAD
ROAD TO DeDIETRiCH
FABRiCATION FACILITY
G REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
o
:I
w
o
..
'"
o
1==1 Ii II
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1094 - DEDIETRICH
DATE: 03/2000 SHEET 1 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
[l PASO, TX (915) 534-9110
SALT LAKE CItY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
.
.
"
PUMP
CONTROL
PANEL
ALARM
PANEL
RELAY
RTU
PANEL
WET WELL
ACCESS
~ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WiRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
0\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
AND
"
~
N
o
::I
w
o
..
m
o
II II Ii II COAPUS C>iRISTI. lX. ('61l 992-228<
It [l PASO. IX (!US) 534-9110
ENGINEERING CORPORATION SAlT L.AJ([ CITY, UT. (801) 251-1455
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
- MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1094 - DEDIETRICH
DATE: 03/2000 SHEET 2 OF 3
JOB NO.: 1075
SCALE: N.T.S.
DR: DAILEY
I
II
r'
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.
1
1
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WiRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
"
,.;
"
"
w
"
v
'"
"
1==11i11
CITY or CORPuS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1094 - DEDIETRICH
DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, TX. (361) 992-2284
n PASO, lX (915) 534-9110
WT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
DR: DAILEY
-
-
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1095
VERDE MAR
LIFT STATION
-, . ~ I
..,...
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1095
VERDE MAR
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: 14501 Verde Mar Dr. LOCALE: East of Park Road 22
SUBDIVISION: WASTEWATER PLANT: Whitecap
LATITUDE: N27037.40T LONGITUDE: W97013.193'
PUMPS: (2)5HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 12" PVC FORCE MAIN: 8"PVC
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is accessed from a service driveway. Vehicle access to the station is possible
from all sides.
Electrical service is routed to the lift station from an overhead service pole. The electric meter and
service disconnect are located on the service pole. Control equipment consists of a Pump Control
Panel, RTU panel, and alarm relay panel. All enclosures are mounted service pole. All control
devices, including pump motor starters, are located in the Pump Control Panel. Conduits are rigid or
flexible PVC. Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole. Wood (Exist)
Antenna Mounting Elevation: 20 ft. . Azimuth: 300"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1095-1 High Level
1095-2 Main Power Failure
1095-3 Motor #1 Failure
1095-4 Motor #2 Failure
1095-5 Motor Control Power Failure
1095-6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheel.doc
STATION NO: 1095
VERDE MAR
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS, 0
Main Power Failure NEW Phase Failure Monitor Pump Control 01 ~-~
JS-l095X
Relay Panel
JS.l095Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-l095Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-l095A 15t Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS.l0958 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-l095 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
---., Float Switch New Junction Box 01 Intrinsically safe barrier relay
LSL-l095 Wet Well Low Level EXISTING
required
XS-1095A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
XS-l0958 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS.l095A Pump #1 Overtoad DEMO Control Relay Pump Control
Panel
[S-10958 . Pump #2 Overload DEMO Control Relay Pump Control
Panel
---- .'~-
Station Instrument Index Report
08/13/200105:43 PM
-
DIRECTIONAL
ANTENNA
SERVICE
VERDE MAR
DRIVE
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
;<
"l
o
"
w
C
'"
'"
o
It II Ii II CORPUS CHOST'. lX. (36\) 99'-'28'
I tiEL PASO. TX (gls) 534-9110
ENGINEERING CORPORATION SAlT I.AKE CITY, Uf. (801) 261-1455
CITY Of CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1095 - VERDE MAR
DATE: 03/2000 SHEET 1 OF 3
DR: DAILEY
--,---
I
r
ELECTRIC SERVICE
POLE
O PUMP
3 CONTROL
PANEL
1
1
1
UTiliTY CO.
METER
J
RTU
PANEL
J
J
SERVICE DISC.
1
1
ALARM
PANEL 1
RELAY
J
J
1
1":\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL
\.2.; ASSOCIATED UNISTRUT SUPPORTS.
/-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
;-;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
\2; ENCLOSURE RATING.
AND
J
J
"
,.
o
'"
o
"
w
o
'"
'"
o
1
J
It II Ii II CORl'\JS CH',STI. ". (J") "'.2284
II I El PASO. IX (915) 5J4-9110
SALT UJ([ CITY. UT. (BOI) 261-'''~
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1095 - VERDE MAR
DATE: 03/2000 SHEET 2 OF 3
J
DR: DAILEY
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
~
.-;
o
"
w
o
'"
'"
o
It II Ii II CORPUS """", T<. (361) 99,.,28,
II I El PASO. TX (1115) 534-9110
SAlT LAKE CITY, UT. (801) 261-14~
ENCINEERINC CORPORATION
CITY OF CORPUS CHRlSn
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1095 - VERDE MAR
DATE: 03/2000 SHEET 3 OF 3
DR: DAILEY
.
f
T
"
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1096
WEBERS GLEN
LIFT STATION
.. ..
.
r TT
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1096
WEBERS GLEN
I STATION TYPE: Lift Station: Wet well, (2) submersible pumps
~- "~----_.,-------"._. "-"-~_._~--_._---_.__..,--"-".__._--"--------------- "~
i ADDRESS: 4051 Aaron St. ! LOCALE: Weber & Aaron i
! -----------.--...--.--....---.-----.-.------------------
I SUBDIVISION:
i WASTEWATER PLANT: 050
,
i LATITUDE: N27041.380'
: LONGITUDE: W97025.10T
. ,
_............."'....................___....."..__n....__......______.__.__________n____..__.____._.______
! SERVICE VOLTAGE: 240/120V, 3PH, 4W i
PUMPS: (2) 20HP
----.---------1--.--.---....--.--..--..---.......-...-......,n__..n__.__.u....___.________.__.___.__._.__.._....u__..___._.____..1
INFLUENT PIPE(S): 16",12"
;...---.------------.-..-----------
. .
I FORCE MAIN: 12" PVC i
I '
__________________.._____._..n........__...__....__._____________________.._____-.E
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap which is surrounded by a decorative masonry
block wall. The station is located adjacent to the street and is accessed from a service driveway.
Vehicle access to the station is possible from three sides.
Electrical service is routed underground to the lift station from an overhead service pole. The electric
meter and service disconnect are located on the service pole. Control equipment consists of a Pump
Control Panel, RTU panel, and alarm relay panel. All enclosures are mounted against the masonry
wall on metal strut support brackets. All control devices, including pump motor starters, are located in
the Pump Control Panel. Conduits are rigid or flexible PVC.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 3520
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1096-1 High Level
1096-2 Main Power Failure
1096-3 Motor #1 Failure
1096.4 Motor #2 Failure
1096-5 Motor Control Power Failure
1096.6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheel.doc
.
I"
r
STATION NO: 1096
WEBERS GLEN
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
JS-1096A Pump #1 Power Failure DEMO Control Relay Pump Control
Panel
JS-l0968 Pump #2 Power Failure DEMO Control Relay Pump Control
Panel
JS-l096X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS.l096Y Pump Ctr1 Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-1096Z RTU Ct~ Pwr Failure NEW 120V AC 019itallnput RTU Panel DI
LS-l096A 1 st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
--------~_.. Float Switch New Junction Box Intrinsically safe barrier relay
LS-10968 2nd Pump Start EXISTING 01
required
LSH.l096 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSL.l096 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l096A Pump #1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-10968 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS.l096A Pump #1 Overload DEMO Control Relay Pump Control
Panel
. f-- DEMO .-. -
YS.l0968 Pump #2 Overload Control Relay Pump Control
Panel
, _H -- - -
Station Instrument Index Report
08/13/2001 05:43 PM
-
.
-
VALVE BOX
ACCESS
ELECTRIC SERVICE
POLE
DIRECTiONAL
ANTENNA
CHEMICAL
TANK
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
,.
"l
o
"
w
C
ID
0>
o
1:111i11
CITY Of CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
ENGINEERING CORPORATION
CORPUS CHRISTI, TX. (J61) 992-2284
(l PASO. lX (915) 534-9110
SAlTlAJ(EClTY,UT. (801)261-1"~
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1096 - WEBERS GLEN
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
JOB NO.: 1075
SCALE: N.T.S.
-
-
-
CHEMICAL
INJECTION
PUMP ENCL.
UTILITY CO.
METER AND
SERVICE DISC.
J
DIRECTIONAL
ANTENNA
1
1
1
CHEMICAl
TANK 1
RTU
PANEL 1
1
1
ALARM
RELAY
PANEL
WET
WELL
ACCESS
1
1
1
1
(2) DISCONNECT POWER, ANTENNA AND ALARM WiRING. REMOVE RTU PANEL
1 ASSOCIATED UNISTRUT SUPPORTS.
r-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
~ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
I, II Ii II COIO'US CHRIST.. lX. ('51> 992-"04
I t I E:l PASO. TX (gIS) 534-9110
SAlT lAKE CITY Uf. (801) 261-1455
ENGINEERING CORPORATION .
"
~
'"
'"
o
"
w
'"
'"
'"
o
JOB NO.: 1 075
AND
1
1
CITY Of CORPUS CHRISTI
1
1
1
WASTEWATER DEPT.
PROJECT NO. 7100
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1096 - WEBERS GLEN
DR; DAILEY DATE: 03/2000 SHEET 2 OF 3
FLOAT SWITCH
TERMINAL STRiP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
ff
o
.0
o
:>
w
o
w
'"
o
1::1 Ii II
CITY Of' CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1096 - WEBERS GLEN
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI. TX. (361) 992-22&4
[l PASO. Tx (9t5) 534-9110
SAlT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
-
Wastewater Department
~ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1097
RINCON NORTH
LIFT STATION
. .. f' .,. " .-".--
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1097
RINCON NORTH
STATION TYPE: Lift Station: Wet well, (2) submersible pumps
ADDRESS: Rincon Industrial Park LOCALE: West of Hwy. 181
SUBDIVISION: WASTEWATER PLANT: Broadway
LATITUDE: N27050.093' LONGITUDE: W97023.360'
PUMPS: (2) 3HP SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 10" FORCE MAIN: 4"
PHYSICAL DESCRIPTION:
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-in-place concrete cap. The station is located adjacent to the street and
does not have a service driveway or security fence. Vehicle access to the station is possible from
three sides.
Electrical service is routed from an overhead service pole. The electric meter and service disconnect
are located on the service pole. Control equipment consists of a Pump Control Panel, RTU panel, and
alarm relay panel. All enclosures are on service pole. All control devices, including pump motor
starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC. Enclosures and
conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. . Azimuth: 196"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1097-1 High Level
1097-2 Main Power Failure
1097.3 Motor #1 Failure
1097-4 Motor #2 Failure
1097-5 Motor Control Power Failure
1097-6 Float Control Failure
08/14/01 3:48 PM
Station Data Sheet.doc
STATION NO: 1097
RINCON NORTH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
1/0
TYP COMMENTS
o
o
- - - I
JS-l097X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS-l097Y Pump Ctrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS-1097Z RTU Ctrt Pwr Failure NEW 120VAC Oigitallnpul RTU Panel 01
LS-l097A 15t Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LS-10978 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-l097 Wet Well High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
-- -----
LSL-1097 Wet Well Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l097A Pump #1 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
XS.10978 Pump #2 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
YS-1097A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS-l0978 Pump #2 Overload DEMO Control Relay Pump Control
Panel
--------- -.
Station Instrument Index Report
08/13/200105:43 PM
t
I
"
r
ELECTRIC SERVICE
POLE
DIRECTIONAL
ANTENNA
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
~
o
'"
w
Q
~
'"
Q
II lllill CORPUS "'RlST.. TX. (361) 99"""
II I tl PASO. TX (915) 5J4-9110
SAlT I..Al(E CITY, UT. (801) 281-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER OEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1097 - RINCON NORTH
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
I "
:1
r
RTU
PANEL
WET WELL
ACCESS
1
.1
1
1
PUMP CONTROL
PANEL
ALARM
RELAY
PANEL
;-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
;-::\ DISCONNECT ALARM WIRING AND REMOVE ALARM RELAY PANEL AND
o ASSOCIATED UNISTRUT SUPPORTS.
~ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
'0 ENCLOSURE RATING.
~
o
N
o
"
w
o
~
m
o
1==11i11
CITY OF CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1097 - RINCON NORTH
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
CORPUS CHRISTI. TX. (361) 992-2284
EL PASO, TX (915) 534-9110
SAlT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
.
I
.
l"
J
1
1
J
1
J
J
J
1
.I
1.
1
1
-
-
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WiRING FOR EXiSTING FLOAT SWITCHES.
'"
"
o
..;
o
'"
~
o
~
'"
o
I, II Ii II CORPUS C""Sf'. lX. (J") 99"'28'
II I El PASO. tx (915) 534-9110
SALT I..AKE CITY, 01. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROUECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1097 - RINCON NORTH
DR: DAILEY DATE: 03/2000 SHEET 3 OF 3
-
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
-
STATION NO.
1098
ALLISON WWTP
LIFT STATION
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 098
ALLISON (LIFT STATION)
-_._~-------_..__._-~.__.~
I ADDRESS: 4101 Allison Drive
I STATION TYPE: Lift Station: Wet well, Dry well, (3) vertical pumps
i LOCALE';-NortheasiDrinlersection oflH:3n;
McKinzie
i SUBDIVISION: Allison Treatment Plant
i PUMPS: (3) 150HP
..- ..
INFLUENT PIPE(S):
PHYSICAL DESCRIPTION:
-1 WAS~:~~!E~~~~~!~..~!~~~~..._._.
I LONGITUDE: W97033.971,
....---1
LATITUDE: N27051.409'
-
I SERVICE VOLTAGE: 480V, 3PH, 3W
__m'.........u........_______..,
i
._~__~_.L~.~~~:~~I~:_..__._.._..__
The lift station is a masonry brick building housing the pumps and electrical equipment. The station is
accessed from a service driveway and is surrounded by a chain link security fence. Lift pumps are
located in the dry well and the top of the structure is flush with grade. The station is located inside the
Allison WWTP. Vehicle access to the station is possibie from one side.
Electrical service to the lift station is routed underground from a pad mounted transformer. Controi
equipment consists of an MCC wi starters, PLC based Pump Control Panel, and RTU panel. All
enclosures are mounted on the masonry wall. All control devices, except level control relays and
pump sequencing controller are located in the MCC. Conduits are rigid or flexible PVC. Enclosures
and conduits are in good condition.
Pumps are controlled by PLC control panel with a pressure transducer level sensor. Trouble alarms
are currently reported through the UHF radio system.
ANTENNA SUPPORT:
Wall Mounted Bracket (New)
Antenna Mounting Elevation: 12 ft. . Azimuth: 136"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1098-1 High Level
1098-2 Main Power Failure
1098-3 Motor I Bubbler Failure
1098.4 Compressor Failure
08/13/01 5:12 PM
Station Data Sheet.doc
STATION NO: 1098
ALLISON (LIFT STATION)
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 2
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
1/0
TYP COMMENTS
IT-1098A Lift Pump 1 Motor Current EXISTING 4~20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-10988 Lift Pump 2 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
IT-l098C Lift Pump 3 Motor Current EXISTING 4-20mA Current Sensor PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
JS.l098 Control Power Failure EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
JS-1098X Main Power Failure EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
JS.l098Y Pump PLC Ctrl Pwr EXISTING Control Relay PLC Control Panel COMM Alarm status obtained from
Failure existing PLC via CQmm link
----- --
JS.1098Z RTU Ctrl Pwr Failure NEW 120VAC Oigitallnpul RTU Panel 01
LSH-l098 Wet Well High level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSHH-l098 Dry Well High Level I EXISTING Float Switch PLC Control Panel COMM Alarm status obtained from
i existing PLC via comm link
LT.l098 Wet Well Level EXISTING Level Tranmitter PLC Control Panel COMM Analog data obtained from exist
PLC via comm link
XS-l098A LiftPump1 H-O-A EXISTING H-O.A Aux Contact PLC Control Panel COMM Alarm status obtained from I
Position" Auto" existing PLC via comm link
XS-10988 Lift Pump 2 H.O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position" Auto" existing PLC via comm link
--------.- -+ PLC Control Panel COMM
XS-l098C Lift Pump 3 H.O-A EXISTING H-O-A Aux Contact Alarm status obtained from
Position" Auto" existing PLC via comrn link
XS-10980 LiftPump1 H-O-A EXISTING H-O-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position "Hand" existing PLC via comm link
XS-1098E Lift Pump 2 H.O-A ! EXISTING H-O-A Aux Contact PLC Control Panel COMM Alarm status obtained from
Position "Hand" I existing PLC via comm link
- EXISTING H-O-A Aux Contact PLC Control Panel COMM Alarm status obtained from
XS-l098F Lift Pump 3 H.D-A
Position "Hand" existing PLC via comm link
XS-1098G Lift Pump 1 Run Status EXISTING Motor Starter N.D. Aux PLC Control Panel COMM Alarm status obtained from
Contact existing PLC via comm link
XS-l098H Lift Pump 2 Run Status EXISTING Motor Starter N.D. Aux PLC Control Panel COMM Alarm status obtained from
I Contact existing PLC via comm link
.-.-----
, XS-10981 Lift Pump 3 Run Status EXISTING Motor Starter N.D. Aux PLC Control Panel COMM Alarm status obtained from
Contact existing PLC via comm link
YS.l098A Lift Pump 1 Fail EXISTING PLC Control Panel COMM Alarm status obtained from
existing PLC via comm link
i YS.l0988 Lift Pump 2 Fail EXISTING PLC Control Panel COMM Alarm status obtained from
, existing PLC via comm link
I
I
r Y~1098C _ Lift Pump 3 Fail EXISTING PLC Control Panel COMM Alarm status obtained from
.__~J existing PLC via comm link
------------- ---"- .---.------ -- -- L-...__~.___.~____..___
Station Instrument Index Report
08/13/200105:43 PM
I
II
II"
~
DIRECTIONAL ANTENNA
(OTHER SIDE OF BLDG.)
~
"""
~
~
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"'
~
o
o
:>
w
o
w
m
o
1:111i11
CITY OF CORPUS CHRISTl
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1098 - ALLISON (LIFT STATION)
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
CORPUS CHRISTI. TX. (361) 992-2284
[L PASO, IX (915) 534-9110
SAlT lAKE CITY, UT. (801) 261-1~55
ENGINEERING CORPORATION
.
.
RTU
PANEL
l
l
L
PUMP CONTROL L
PANEL
L
1
1
1
L
L
1
I
I
I
o DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
;-:;\ PROVIDE COMMUNICATIONS INTERFACE BETWEEN EXISTING MODICON QUANTUM
\3:...; PLC AND NEW RADIO TELEMETRY SYSTEM.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1098 - ALLISON LIFT STATION
DR: DAILEY DATE: 03/2000 OF 2
11
o
,.;
o
'"
w
o
"'
'"
o
II II Ii II CORPUS CH""". TX. (361) 992'228'
II I El PASO, TIC (915) S)4-9110
SAlT LAK[ CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
JOB NO.: 1075
SCALE: N.TS
PRQUECT NO. 7100
L
1
L
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1099
RINCON SOUTH
LIFT STATION
-. . '" ~..
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.1 099
RINCON SOUTH
i STATION TYPE: Lift Station: Wet well, (2) submersible pumps
--"----.------.--.--..----..............---...-..-.....-............-'-"-'--""-~~-1
i LOCALE: West of Hwy. 181
;_.,_._._.,----~~~--_._.,_._-_..__.__.__.".,_.__...,.._.._............--.-..........--.----,
i WASTEWATER PLANT: Broadway
i ADDRESS: Rincon Industrial Park
i SUBDIVISION:
I LATITUDE: N27049.713'
I PUMPS: (2) 3HP
! LONGITUDE: W97023.550'
!
, .
. '
t"----.----.~--_._.--.---_.--_._-_.-._._-_._--.-.-_._..-_.._.,___.__._._.._._._._..__.__m.__________~
....-...-.-------~~---_._------_.-..,--.-..-.-.-.-.,.._.----1
! SERVICE VOLTAGE: 240/120V, 3PH, 4W
INFLUENT PIPE(S): 8"
PHYSICAL DESCRIPTION:
! FORCE MAIN: 4"
_._.__.............L_~___._.__._._.._._....__._____.____~___~________..__..._.......____l
The lift station is an open air facility consisting of a below grade wet well with submersible pumps. The
wet well is topped with a cast-In.place concrete cap. The station is located adjacent to the street and
does not have a service driveway or security fence. Vehicle access to the station is possible from
three sides.
Electrical service is routed from an overhead service pole. The electric meter and service disconnect
are located on the service pole. Control equipment consists of a Pump Control Panel, RTU panel, and
alarm relay panel. All enclosures are mounted on the service pole. All control devices, including
pump motor starters, are located in the Pump Control Panel. Conduits are rigid or flexible PVC.
Enclosures and conduits are in good condition.
Pumps are controlled directly with displacement type float switches interfaced through control relays
and a pump sequencing controller unit. Trouble alarms are currently reported through the UHF radio
system.
ANTENNA SUPPORT:
Pole - Round Alum. Tapered (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 1960
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1099-1 High Level
1099.2 Main Power Failure
1099-3 Motor #1 Failure
1099-4 Motor #2 Failure
1099-5 Motor Control Power Failure
1099.6 Float Control Failure
08/13/01 5:12 PM
Station Data Sheet. doc
-
STATION NO: 1099
RINCON SOUTH
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 9
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
JS-l099X Main Power Failure NEW Phase Failure Monitor Pump Control 01
Relay Panel
JS.l099Y Pump Gtrl Pwr Failure NEW Control Relay (24 V AC Pump Control 01
coil) Panel
JS.l099Z RTU CtrI Pwr Failure NEW 120VAC Digital Input RTU Panel 01
LS-1099A 1 st Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier retay
required
LS-l0998 2nd Pump Start EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
LSH-1099 Wet Wen High Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
- .-.. .~_.._-
LSL.1099 Wet Wen Low Level EXISTING Float Switch New Junction Box 01 Intrinsically safe barrier relay
required
XS-l099A Lift Pump 1 Run Status NEW Motor Starter N.D. Aux Pump Control 01
Contact Panel
XS-l0998 Lift Pump 2 Run Status NEW Motor Starter N.O. Aux Pump Control 01
Contact Panel
YS-1099A Pump #1 Overload DEMO Control Relay Pump Control
Panel
YS.l0998 Pump #2 Overload DEMO Control Relay Pump Control
Panel
-- - - ...
Station Instrument Index Report
08/13/200105:43 PM
.
"
"
~
RINCON
ELECTRIC
WET WELL
ACCESS
VALVE BOX
ACCESS
MANHOLE
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'"
~
o
"
w
o
'"
'"
o
II II Ii II CORPUS CH."'. TX. ("'j 992'''8<
It I I [L PASO. TX (915) 534-9110
SAlT LAKE CITY, UT. (SOl) 26'-14~
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1099 - RINCON SOUTH
DR: DAILEY DATE: 03/2000 SHEET 1 OF 3
.
.
-
ELECTRIC SERVICE
POLE
RTU
PANEL
WET WELL
ACCESS
1
1
1
1
PUMP CONTROL 1
PANEL
ALARM
RELAY
PANEL
r-:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL AND
\.2..; ASSOCIATED UNISTRUT SUPPORTS.
r::\ DISCONNECT ALARM WIRiNG AND REMOVE ALARM RELAY PANEL AND
\3...; ASSOCIATED UNISTRUT SUPPORTS.
r;\ REPAIR ALL HOLES IN PUMP CONTROL PANEL TO MAINTAIN THE NEMA
o ENCLOSURE RATING.
~
N
o
"
w
o
m
m
o
II II Ii II CORPUS CI<R1Sn. TX. (361) 99'."8<
I tiEL PASO. 1X (915) ~-9110
SALT l.AI([ CITY UT. (801) 261-1"~
ENGINEERING CORPORATION .
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1099 - RINCON SOUTH
DR: DAILEY DATE: 03/2000 SHEET 2 OF 3
SCALE: N.T.S.
-
.
"
1
1
J.
1
1
1
1
1
1
1
1
L
FLOAT SWITCH
TERMINAL STRIP
1. TRACE OUT AND REMOVE ALL EXISTING ALARM WIRING.
2. INSTALL NEW PHASE FAILURE MONITOR RELAY.
3. REROUTE WIRING FOR EXISTING FLOAT SWITCHES.
<>
'"
o
n
o
"
w
o
m
'"
o
1111 Ii II
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
LIFT STA. 1099 - RINCON SOUTH
OR: DAILEY DATE: 03/2000 SHEET 3 OF 3
CORPUS CHRISTI, IX. (361) 992-2284
rl PASO, TX (915) 534-9110
SAlT LAJ([ CITY, UT. (BOI) 261-145!1
ENGINEERING CORPORATION
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1101
BROADWAY WWTP
(OUTFALL)
. ~ ...
,-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1101
BROADWAY (OUTFALL)
! STATION TYPE: Wastewater Treatment Plant Outfall
i ADDRESS: 1402 West Broadway
!
i LOCALE: Southwest of Harbor Bridge
._."...~-------_.._-~ ....__.___....._______n___..__.._______....._.______ ..j
~
i SUBDIVISION: Broadway WWTP
.--.~_.,--t.------.-_."._-~~---.-~--_.._.,._~-___.....,..___.___ ...___n._......._.________..........._.._______.
I WASTEWATER PLANT:
~
i LATITUDE: N27048.277'
I
f--.
..--______-.--...f.....u........______.........._________n_.____.-...
'LONGITUDE: W97024.091'
--------------~----_.._-----~---
I PUMPS:
, SERVICE VOLTAGE:
,
i INFLUENT PIPE(S):
----t---------..u..---.--__..........________........____ .---
i FORCE MAIN:
i___...".____..__.___._______.______..n_n________....._....---_..._..._...__________...m._..._________..__.1
PHYSICAL DESCRIPTION:
The outfall analyzer building is a fiberglass building housing analyzer equipment. The site is located
inside the Broadway WWTP. Trouble alarms are currently reported through the UHF radio system.
(Note: This site currently under design/construction and may differ from actual site conditions. 110
listed is based on new PLC based design.)
ANTENNA SUPPORT:
1.1/4" 0.0. Antenna Mast (New)
Antenna Mounting Elevation: 10 ft. - Azimuth: 196"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1101.1 Low Chlorine
1101-2 High Sulfur Dioxide
1101-3 Low Sulfur Dioxide
08/13/01 5:12 PM
Station Data Sheet.doc
-
STATION NO: 1101
BROADWAY (OUTFALL)
STATION INSTRUMENT INDEX:
DIGiTAL INPUTS: 1
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
AIT-l004 Hypochlorite Residual EXISTING Analyzer COMM Alarm status obtained from exist
Analyzer Pump Control PLC via comm link
AIT-l007 Effluent to Outfall EXISTING Analyzer COMM Analog data obtained from exist
Bisulfite Residual A PlC via comm link
AS-ll01A Low Chlorine EXISTING COMM Alarm status obtained from exist
Pump Control PLC via comm link
AS-ll01B High Sulfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
AS-1101C Low Sulfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
JS.1101Z RTU CtrI Pwr Failure NEW 120VAC Oi9ilallnput RTU Panel DI
. -----
L1T.IOOO BHT-1 Hypochlorite Tank EXISTING Chlorine COMM Analog data obtained from exist
Level Treatment PLC PLC via comm link
L1T-1001 BHT-2 Hypochlorite Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
L1T-1002 BHT.3 Hypochlortte Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
L1T-1005 BBT-l Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
I L1T-l006 BBT~2 Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level I PLC via comm link
---.- ------
Station Instrument Index Report
08/13/2001 05:43 PM
.
..
-
~
~
ANALYZER
BLDG.
DIRECTIONAL
ANTENNA
~
~ PARSHALL
FLUME
~
(2) REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
'-'
'"
o
o
"
w
o
o
1::11i11
CITY OF CORPuS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
OUTFALL 1101 - BROADWAY (OUTFALL)
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
CORPUS CMRlSTI. lX. (J61) 992-2284
[1 PASO. lX (915) 5J4-9110
SALT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
-
-
1
1
1
1
1
1
1
1
1
1
L
L
RTU PANEL.
L
L
ANALYZER
BLDG.
r:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE
o REPAIR HOLES iN FIBERGLASS ANALYZER BUILDING.
"
~
o
N
o
"
w
o
o
L
It II Ii II CORPUS CH'''''. T>. (36') 992-2'84
II I n PASO, TX (915) 534-9110
SAlT lAKE CITY, UT. (801) 261-1<455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
L
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
OUTFALL 1101 - BROADWAY (OUTFALL)
DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
.
r
11
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
-
-
STATION NO.
1102
-
080 WWTP
(OUTFALL)
- ~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1102
OSO (OUTFALL)
-
! STATION TYPE: Wastewater Treatment Plant Outfall
~ . ....._...~........_..._....._._.......................--_......
i ADDRESS: 501 Nile r LOCALE: South of Del Oso Road
, .
i--
! SUBDIVISION: Oso WWTP
i
,.
i LATITUDE: N27042.592'
i--
I PUMPS:
I INFLUENT PIPE(S):
L
PHYSICAL DESCRIPTION:
,
........."-""------.-_.....
_..._-J\^JA~~:\f\I~!:~.I_'_LA~~:
i LONGITUDE: W97020.324'
. --1.------.............-.......................................... ..................... .........,
I SERVICE VOLTAGE:
j ......___._______..............__.____.__.___.m.............._.______....n..... .........._...___
I FORCE MAIN:
The outfall analyzer building is a fiberglass building housing analyzer equipment. The site is located
across Nile road from the Oso WWTP and is surrounded by a chain link security fence. Trouble
alarms are currently reported through the UHF radio system. (Note: This site currently under
design/construction and may differ from actual site conditions. I/O listed is based on new PLC based
design. Proposed PLC system to be installed inside Oso WWTP as indicated on drawings.)
ANTENNA SUPPORT:
1-1/4" 0.0. Antenna Mast (New)
Antenna Mounting Elevation: 10ft. - Azimuth: 283"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1102-1 Low Chlorine
1102-2 High Sulfur Dioxide
1102-3 Low Sulfur Dioxide
08/13/01 5:12 PM
Station Data Sheel.doc
- ~
.
STATION NO: 1102
OSO (OUTFALL)
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 1
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
AIC-2010 West Chlorine Contactor EXISTING Analyzer COMM Analog data obtained from exist
Residual Control PLC via comm link
AIC-2021 East Chlorine Contactor EXISTING Analyzer COMM Analog data obtained from exist
Residual Control PLC via comm link
AIC-2029 Effluent to Outfall EXISTING Analyzer COMM Analog data obtained from exist
Bisulfite Residual C PlC via comm link
AS.ll02A Low Chlorine EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via oomm link
AS-11028 High Sulfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via CQmrn link
AS.ll02C Low Sutfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via oomm link
..-
FSL-2008 Eductor Train-A EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL-2009 Eductor Train.B EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL-2019 Eductor Train~A EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL.2020 Eductor Train-B EXiSTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL.2027 Eductor Train~A Bisulfite EXISTING COMM Alarm status obtained from exist I
Flow Switch Lo Pump Control PLC via comm link
FSL-2028 Eductor Train-B Bisulfite EXISTING COMM Alarm status obtained from exist
Flow Switch Lo Pump Control PLC via comm link
'm .
JS-ll02Z RTU Ctrl Pwr Failure NEW 120VAC Oigllallnput RTU Panel 01
LIT -2000 OWHT-1 Hypochlorite EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T-2001 OWHT ~2 Hypochlorite EXiSTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T-2002 OWHT -3 Hypochlorite EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
LIT -2003 OWHT -4 Hypochlorite EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T-2011 OEHT-l Hypochlorite EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T-2012 OEHT-2 Hypochlortte EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T.2013 OEHT -3 Hypochlorite EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T-2014 OEHT -4 Hypochlorite EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T-2022 OBT.1 Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
LIT -2023 OBT-2 Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
PSL-2007 Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch Pump Control PLC via comm link
- -
PSL-2018 Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch Pump Control PLC via comm link
1--.
PSL.2026 l Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch I I Pump Control PLC via CQmm li_~~_J
- - ----
Station Instrument Index Report
08/131200105:43 PM
.
r
. .
1r
-
ANALYZER
BLDG.
-
o REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
~
"!
o
:>
w
o
N
o
11111i II CORl'IJS CliOS". ". (J61l99'-"M
I t I [l PASO. TX (915) 534-9110
SAlTl.AJ(EClTY,UT. (801)261-1455
ENGINEERING CORPORATION
CtTY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
OUTFALL 1102 - 050 (OUTFALL
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
.
I
-
ANALYZER
BLDG.
RTU
PANEL
1
1
1
1
1
1
1
1
SERVICE DROP
CONDUIT
L
1
1
L
L
L
L
I
L
r:\ DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
\..2J REPAIR HOLES IN FIBERGLASS ANALYZER BUILDING.
"
~
N
o
"
w
o
N
o
11111i II CORPUS CHROsn. ". (361) "'-"84
II I n. PASO, TX (gIS) 534-9110
SALT LAK[ CITY, uf. (801) 261-14!l5
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
OUTFALL 1102 - 050 (OUTFALL)
DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
-
-
Wastewater Department City of Corpus Christi
Microwave Communication System Project No. 7100
-
-
-
STATION NO.
1104
ALLISON WWTP
(OUTFALL)
. ~ I
11'"
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1104
ALLISON (OUTFALL)
I STATION TYPE: Wastewater Treatment Plant Outfall
-
f-
I LOCALE: Northeast of Ini"ersection'ofiH=3'tS.--
, McKinzie
!-----__..______........n__...____.__n__.__..._______n_
i WASTEWATER PLANT:
I __...___._______.___._...__.______...........__.______m_._.....--..----- .....................--.------1
I LONGITUDE: W97033.971,
ADDRESS: 4101 Allison Drive
i SUBDIVISION: Allison WWTP
I LATITUDE: N27"51.409'
_.,._.._--~_.._--------_._..__..._._---_.
i SERVICE VOLTAGE:
-~-+-_.._.-._-~_._._.__.____________..,..,..___.___.______..............__n_
I FORCE MAIN:
"'."'.'.'i
i PUMPS:
i INFLUENT PIPE(S):
.......;
PHYSICAL DESCRIPTION:
The outfall analyzer building is a fiberglass building housing analyzer equipment. The site is located
inside the Allison WWTP. Trouble alarms are currently reported through the UHF radio system.
(Note: This site currently under design/construction and may differ from actual site conditions. I/O
listed is based on new PLC based design.)
ANTENNA SUPPORT:
1-1/4" 0.0. Antenna Mast (New)
Antenna Mounting Elevation: 10 ft. - Azimuth: 274"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1104.1 Low Chlorine
1104-2 High Sulfur Dioxide
1104-3 Low Sulfur Dioxide
08/13/01 5:12 PM
Station Data Sheet.doc
---,
I
1""
STATION NO: 1104
ALLISON (OUTFALL)
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 1
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE.IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
AIC-4008 East Chlorine Contaetor EXISTING Analyzer COMM Analog data obtained from exist
Residual Control PLC via comm link
AIC-4012 West Chlorine Contactor EXISTING Analyzer COMM Analog data obtained from exist
Residual Control PLC via comm link
AIC-4020 Effluent to Outlall EXISTING Analyzer COMM Analog data obtained from exist
Bisulfite Residual C PLC via comm link
AS-1104A Low Chlorine EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
.
AS-l104B High Sulfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
AS-ll04C Low Sulfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
. ...
FSL-4006 Eductor Train-A EXISTING COMM Alarm status obtained from exist
I Hypochlorite Flow Switch Pump Control PLC via comm link
FSL-4007 Eductor Train-B EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL-4010 Eductor Train-A EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch I Pump Control PLC via comm link
FSL-4011 Eductor Train-B EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL.4018 Eductor Train-A Bisulfite EXISTING COMM Alarm status obtained from exist
Flow Switch La Pump Control PLC via comm link
FSL.4019 Eductor Train-B Bisulfite EXISTING : COMM Alarm status obtained from exist
Flow Switch Lo Pump Control PLC via comm link
---- - RTU Panel -
JS-l104Z RTU Ctrl Pwr Failure NEW 120VAC Digital Input 01
i
L1T.4000 AHT.l Hypochlorite Tank EXISTING COMM 'Analog data obtained from exist
level , PLC via comm link
LIT -4001 AHT-2 Hypochlorite Tank EXISTING COMM Analog data obtained from exist
I Level PLC via comm link
LIT -4013 ABT-1 Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
L1T-4014 ABT-2 Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level I PLC via comm link
PSL-4005 Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch Pump Control PLC via comm link
~. Alarm status obtained from exist
PSL -4009 Eductor Panel Effluent EXISTING COMM
Water PSI Switch Pump Control PLC via comm link
.
PSL-4017 Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch Pump Control PLC via comm link
------- ------
Station Instrument Index Report
08/13/200105:43 PM
.
.
.,
-
-
ANALYZER
BLDG.
FLOODLIGHT
POLE
...
...
-
TRANSFORMER
-
PARSHALL
FLUME
G REMOVE ANTENNA, ANTENNA SUPPORT PIPE AND ALL ASSOCIATED HARDWARE.
"
'"
'"
o
:>
w
o
v
o
II II Ii II CORP\lS CHOS". TX. (361) 992'228'
II I (l PASO. Tx (915) 5.34-9110
SALT I.Al(E CITY, UT. (SOl) 261-1455
ENGINEERING CORPORATION
CITY or CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
OUTFALL 1104 - ALLISON (OUTFALL
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
--,
:1
r
1
ANALYZER
BLDG.
1
1
1
1
1
1
1
J
L
1
G
DiSCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
REPAIR HOLES IN FIBERGLASS ANALYZER BUiLDING.
1
L
1
~
N
o
"
w
o
v
o
L
1==11i11
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
l
CORPUS CHRISTI, TX. (361) 992-2284
[l PASO, TX (915) ~-9ItO
S4LT LAKE CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
OUTFALL 1104 - ALLISON (OUTFALL)
DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
JOB NO.: 1075
SCALE: N.T.S.
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
-
STATION NO.
1105
LAGUNA MADRE WWTP
(OUTFALL)
- ~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1105
LAGUNA MADRE (OUTFALL)
STATION TYPE: Wastewater Treatment Plant Outfall
ADDRESS: 201 Jester Street LOCALE: East of Naval Air Station Drive
SUBDIVISION: Laguna Madre WWTP WASTEWATER PLANT:
LATITUDE: N27040.248' LONGITUDE: W97016.218'
PUMPS: SERVICE VOLTAGE:
INFLUENT PIPE(S): FORCE MAIN:
PHYSICAL DESCRIPTION:
The outfall analyzer building is a fiberglass building housing analyzer equipment. The site is located
inside the Laguna Madre WWTP. Trouble alarms are currently reported through the UHF radio
system. (Note: This site currently under design/construction and may differ from actual site conditions.
I/O listed is based on new PLC based design.)
ANTENNA SUPPORT:
1.1/4" 0.0. Antenna Mast (New)
Antenna Mounting Elevation: 10ft. . Azimuth: 292"
EXISTING STATION ALARMS:
ALARM NO DESCRIPTION
1105.1 Low Chlorine
1105-2 High Sulfur Dioxide
1105-3 Low Sulfur Dioxide
08/13/01 5:12 PM
Station Data Sheet.doc
.
r
,.
r
STATION NO: 1105
LAGUNA MADRE (OUTFALL)
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 1
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
o
o
AIC-5008 East Chlorine Contactor EXISTING Analyzer COMM Analog data obtained from exist
Residual Control PLC via comm link
AIC.5012 West Chlorine Contactor EXISTING Analyzer COMM Analog data obtained from exist
Residual Control PLC via comm link
AIC-5020 Effluent to Outfall EXISTING Analyzer , COMM Analog data obtained from exist
Bisulfite Residual C PLC via comm link
AS.l1 05A Low Chlorine EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
AS.11058 High Sulfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
AS-l105C Low Sulfur Dioxide EXISTING Analyzer COMM Alarm status obtained from exist
Pump Control PLC via comm link
... - ..--
FSL.5006 Eductor Train-A EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL-5007 Eductor Train-B EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL-5010 Eductor Train.A EXISTING COMM Alarm status obtained from exist
Hypochlorite Flow Switch Pump Control PLC via comm link
FSL.5011 Eductor Train-B EXISTING I COMM Alarm status obtained from exist
Hypochlorite Flow Switch , Pump Control PLC via comm link
FSL-5018 Eductor Train-A Bisulfite EXISTING COMM Alarm status obtained from exist
Flow Switch Lo Pump Control PLC via comm link
FSL-5019 Eductor Train.B Bisulfite EXISTING COMM Alarm status obtained from exist
Flow Switch Lo Pump Control PLC via comm link
-- .. ..--
JS-1105Z RTU Ctrl Pwr Failure NEW 120VAC Olgllallnput RTU Panel 01
LIT .5000 LMHT -1 Hypochlorite EXISTING COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T-5001 LMHT-2 Hypochlorite EXISTING , COMM Analog data obtained from exist
Tank Level PLC via comm link
L1T.5013 LMBT-1 Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
L1T-5014 LMBT.2 Bisulfite Tank EXISTING COMM Analog data obtained from exist
Level PLC via comm link
PSL-5005 Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch Pump Control PLC via comm link
PSL-5009 Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch Pump Control PLC via comm link
PSL-5017 Eductor Panel Effluent EXISTING COMM Alarm status obtained from exist
Water PSI Switch Pump Control PLC via comm link
L-._....___ --- --'-'- .
Station Instrument Index Report
08113/200105:43 PM
-
-
ANALYZER
BLDG.
DIRECTIONAL
ANTENNA
-
TRANSFORMER
PARSHALL
FLUME
o REMOVE ANTENNA, ANTENNA SUPPORT PiPE AND ALL ASSOCIATED HARDWARE.
co
~
o
o
:>
w
o
~
o
I, -Iii II CORPuS CHlloST'. " ("'J 99"228'
[l PASO. IX (915) 534-9110
II I SAlT lAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
OUTFALL 1105 - LAGUNA MADRE (OUTFALL)
DR: DAiLEY DATE: 03/2000 SHEET 1 OF 2
---, "
r
,.
r
ANALYZER
BLDG.
DIRECTIONAL
ANTENNA
PARSHALL
FLUME
O DISCONNECT POWER, ANTENNA AND ALARM WIRING. REMOVE RTU PANEL.
1 REPAIR HOLES IN FIBERGLASS ANALYZER BUILDING.
1
1
1
RTU
PANEL 1
1
1
1
1
1
1
L
L
L
L
L
L
CITY OF" CORPUS CHRISTI WASTEwATER DEPT. PROJECT NO. 7100
II II Ii II CORPuS CHRISTI. IX. (361) 992-2284 MICROWAVE COMMUNICATION SYSTEM L
.t I ~::ET~. lIT. ~:::~ :~:::;: CONSTRUCTION PHOTOGRAPH
ENGINEERING CORPORATION OUTFALL 1105 - LAGUNA MADRE (OUTFALL) I
JOB NO.: 1075 SCALE: N.T.S. DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
11
o
N
o
"
w
o
",
o
-
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
-
-
-
-
STATION NO.
1181
-
-
~
LICENSED REPEATER
. ~ 'IIf
,..
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
,.-
STATION NO. 1181
LICENSED REPEATER
,....
STATION TYPE: Repeater Radio Site
ADDRESS: Civitan Dr. LOCALE: City Service Center. Vehicle Main!. Bldg.
SUBDIVISION: WASTEWATER PLANT:
LATITUDE: N27043.650' LONGITUDE: W97025.470'
PUMPS: SERVICE VOLTAGE:
INFLUENT PIPE(S): FORCE MAIN:
,.-
,.-
PHYSICAL DESCRIPTION:
,.-
The existing radio tower is located adjacent to City vehicle maintenance building on Civitan street and
is surrounded by a chain link security fence. The existing radio equipment is located inside the
masonry brick building and is surrounded by a chain link fence. Vehicle access to the tower and
building is possible from two sides.
,...
ANTENNA SUPPORT:
Tower - Free standing Lattice (Exist)
Antenna Mounting Elevation: 160 ft. _ Azimuth: "
~
,...
,.-
08/13/01 5:12 PM
Station Data Sheet.doc
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
NO. 1181 - LICENSED REPEATER
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
....
....
....
....
....
.,
o
(3)
REMOVE ANTENNA, ALL ANTENNA SUPPORT HARDWARE,
COAX CABLE AND CABLE SUPPORT HARDWARE.
REPAIR COAX CABLE PENETRATION INTO BUILDiNG.
"
"
"
"
"
w
"
'"
.-
1==11i11
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
CORPUS CHRISTI, IX. (J61) 992-2284
[L PASO, lX (915) 534-9110
SAlT lAKE ClTY,UT. (801)261-1455
ENGINEERING CORPORATION
JOB NO.: 1075
SCALE: N.T.S.
.
'"
160 FT
ANTENNA
TOWER
COAX CABLE
ROOF
PENETRATION
VEHICLE
MAl NT. BLDG.
PROJECT NO. 7100
"1"'
1
SAVAGE LANE L
RECEIVER
L
L
1
L
1
HOLLY ROAD
RECEIVER
EQUIPMENT ENCLOSURE
1
1
L
L
0)
REMOVE EXISTING SAVAGE LANE AND HOLLY ROAD RADIO EQUIPMENT AND ALL
ASSOCIATED HARDWARE. COORDINATE DEMOLITION WITH DON NATINGER.
1
"
"
o
N
o
:>
w
o
'"
1
L
1
11111i II CORl'VS CHO".. lX. ('OIl 99'-'28'
I II I (l PASO. IX (915) 534-9110
SAlT l.Al([ CITY, uT. (801) 261-14~
ENGINEERING CORPORATION
CITY Of CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
NO. 1181 - LICENSED REPEATER
DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
L
.
r
OT
r
Wastewater Department
_ Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO.
1182
TAIL-END LINK
AT O.N. STEVENS WATER
TREATMENT PLAN
-. I r ~
~
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1182
TAIL-END LINK
.-----
,
i
,
i STATION TYPE: Repeater Radio Site
I
i LOCALE: ONSWTP
I "-~.."---_.".,.._-"-_."._._-_._---"-"---------------..-.- .. .... """"..--...--..-....--..ui
I WAS~:~~~:~~LAN~:____._ .............. .... ...........----1
I LONGITUDE: W97023.597'.................._..i
I SERViC-E-\lOLTAGE~-.....
!
-
i ADDRESS: 13101 Up River Road
! SUBDIVISION:
~
i LATITUDE: N27047.226'
-
i PUMPS:
i INFLUENT PIPE(S):
i
! FORCE MAIN:
!
---------..--.-...........--.......................-....,;
-
PHYSICAL DESCRIPTION:
-
The existing radio tower is located inside the O. N. Stevens Water Treatment Plant at the nortwest
corner. The entire plant is surrounded by a chain link security fence and must be entered through the
security guard shack. The existing radio equipment room is a portable sheet metal building located
adjacent to the tower. Vehicle access to the tower and building is possible from all sides.
ANTENNA SUPPORT:
Tower. Free standing Lattice (Exist)
Antenna Mounting Elevation: 160 ft. . Azimuth: "
.-
08/13/01 5:12 PM
Station Data Sheet.doc
.
.
T
STATION NO: 1182
TAIL.END LINK
STATION INSTRUMENT INDEX:
DIGITAL INPUTS:
ANALOG INPUTS:
1
o
TAG NO.
IJS:118~[
i___n
SERVICE DESCRIPTION STATUS FIELD DEVICE
RTU CtrI Pwr Failure_] - NEW J--i'20VAC Oigilallnpul
Station Instrument Index Report
. ..
I.
TIE-IN LOCATION
RTU pa~ I 01
DIGITAL OUTPUTS:
ANALOG OUTUTS:
110
TYP COMMENTS
I
o
o
08/13/2001 05:43 PM
COMMUNICATIONS
BUILDING
,-
~
~
1. THIS PICTURE is OF THE COMMUNICATiONS BLDG., RADIO TOWER AND IS FOR
INFORMATiON ONLY. THERE is NO DEMOLITION WORK AT THIS SiTE.
'-'
'<
c
;:;
:>
w
C
N
"'
1:11 Ii II
CITY OF CORPUS CHRISTI
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
NO. 1182 - TAIL-END LINK
DATE: 03/2000 SHEET 1 OF 2
WASTEWATER DEPT.
PROUECT NO. 7too
DR: DAiLEY
1"
I
- .--
J
L
J
l
L
1
1
L
1
I
~
I
~.
1
IS FOR INFORMATION
1
L
1
COMMUNICATIONS
BUILDING
1. THIS PICTURE is OF THE COMMUNICATiONS BLDG. AND
ONLY. THERE IS NO DEMOLITION WORK AT THIS SITE.
<>
~
N
o
:>
w
"
N
00
1
II II Ii II CORPUS C..ST>. TX. (J61) 992-228'
II I [l PASO. TX (915) 534-9110
SAlT LAKE CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
NO. 1182 - TAIL-END LINK
DATE: 03/2000 SHEET 2 OF 2
L
DR: DAILEY
. ..
I'"
n.
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
~.....
~
-
.....
STATION NO.
1183
DAYTIME DISPATCHER
. ~ I
.,..
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1183
DAYTIME DISPATCHER
i STATION TYPE: HMI Master Station
~-'--'~- _.,---~."._...__.,---,._._.._-_....._-_._._-_._---_._._---.--- ----.-.---.-----.--1
'ADDRESS: 2726 Holly Road 1 LOCALE: East of Ayers St. 1
i.-.--.--------...---_._~_____i__.,..____"..____..."._____..,------...----...---.--.-------.....-__.______.____..u_-_....____...._____m....__._1
i SUBDIVISION: 1 WASTEWATER PLANT: .
. .
' .
;-_.._-----_._-_.._--'-~---_._-------_.__._--_..,-
. .
i LATITUDE: N27043.444'
i LONGITUDE: W97025.630'
...n.. -......----...----_......______._.__..._____....___.....___...____..n____..______n..__....__-/
i PUMPS:
...-----...--_.".____m_._____m.........n___...n_____..._..__
I
...---......-----.....---.......-)
!
. .
;.,._-----------_._-----_.._---_._._,-_.~-~...,._---- -..... --......-.---........----......---.....,.----......- _...._-~_._.._-~~._.".- .....-----.....--.
i INFLUENT PIPE(S): i FORCE MAIN: i
L..... -.-.-.--.-.-___--'.._......._....._...._.....__...._.........................-............--._..._...._J
PHYSICAL DESCRIPTION:
i SERVICE VOLTAGE:
The City Service Centery Annex building is a masonry brick Office building. The existing Daytime
Dispatcher unit is located inside the City Water department offices.
ANTENNA SUPPORT:
Wall Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. _ Azimuth: 0
~
08/13/01 5:12 PM
Station Data Sheel.doc
.
.
STATION NO: 1183
DAYTIME DISPATCHER
DIGITAL INPUTS: 1 DIGITAL OUTPUTS: 0
STATION INSTRUMENT INDEX: ANALOG INPUTS: 0 ANALOG OUTUTS: 0
1/0
TAG NO. SERVICE DESCRIPTION STATUS FIELD DEVICE TIE-IN LOCATION TYP COMMENTS
I~S:iI83Z J RTU Ctrl Pwr F:IUr:..L:::..l~OVAC OiQi:llnput J .. RTU pa~OI 1- .... ...~
Station Instrument Index Report
08/1312001 05:43 PM
I ..
II
'f'!'!
-
-
SIGNAL CRAFTER
BASE UNIT
MONITOR
& CPU
...
-
-
'"
...
...
...
...
...
...
...
o
o
REMOVE EXISTING BASE UNIT AND ALL ASSOCIATED HARDWARE.
REMOVE EXISTING MONITOR, CPU AND ALL ASSOCIATED HARDWARE.
..
..
...
"
~
q
o
:>
w
o
~
'"
-
1:111i11
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
CORPUS CHRISTI. Tl(. (J61) 992-2284
EL PASO. TlI (915) 534-9110
$.f.LT lAK[CITY, UT. (801) 261-1455
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
NO. 1183 - DAYTIME DISPATCHER
DR: DAILEY DATE: 03/2000 SHEET 1 OF 1
P'
JOB NO.: 1075
SCALE: N.T.S.
,.
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
"
STATION NO.
1184
NIGHT DISPATCHER
_ r
Wastewater Department
Microwave Communication System
City of Corpus Christi
Project No. 7100
STATION NO. 1184
NIGHT DISPATCHER
STATION TYPE: HMI Master Station
ADDRESS: 1541 Saratoga Blvd. LOCALE: Greenwood WWTP
SUBDIVISION: WASTEWATER PLANT:
LATITUDE: N27"43.259' LONGITUDE: W97022.383'
PUMPS: SERVICE VOLTAGE:
INFLUENT PIPE(S): FORCE MAIN:
PHYSICAL DESCRIPTION:
The Greenwood WWTP Office/Control building is a masonry brick building. The new Night Dispatcher
unit is to be located inside the Plant SCADA room on 2nd floor.
ANTENNA SUPPORT:
Wail Mounting Bracket (New)
Antenna Mounting Elevation: 20 ft. - Azimuth: 77"
08/13/01 5:12 PM Station Data Sheet.doc
STATION NO: 1184
NIGHT DISPATCHER
STATION INSTRUMENT INDEX:
DIGITAL INPUTS: 1
ANALOG INPUTS: 0
TAG NO. SERVICE DESCRIPTION STATUS
FIELD DEVICE
TIE-IN LOCATION
DIGITAL OUTPUTS: 0
ANALOG OUTUTS: 0
110
TYP COMMENTS
AIT-l06 Effluent Structure EXISTING Analyzer Greenwood COMM Analog data obtained from exist
Dissolved Oxygen WWTP OCS DeS network via comm link
AIT-l09 Aeration Basin 1 C EXISTING Analyzer Greenwood COMM Analog data obtained from exist
Dissolved Oxygen WWTP OCS DeS network via comm link
AIT-ll0 Aeration Basin 2C EXISTING Analyzer Greenwood COMM Analog data obtained from exist
Dissolved Oxygen I WWTP OCS IDGS network via comm link
BA-281 Digester Heater No. 1 EXISTING Flame UV Scanner Greenwood COMM Alarm status obtained from exist
Flame Failure I WWTP OCS DeS network via comm link
BA-282 Digester Heater NO.2 EXISTING Flame UV Scanner Greenwood COMM Alarm status obtained from exist
Flame Failure WWTP OCS DeS network via comm link
EAL-255 Power Fail MCC-5 EXISTING Phase Failure Monitor Greenwood COMM Alarm status obtained from exist
Relay WWTP OCS DeS network via comm link
, ..- --
EAL .256 Power Fail MCC~6 EXISTING I Phase Failure Monitor Greenwood COMM Alarm status obtained from exist
Relay WWTP OCS DCS network via comm link
FAL-191 Sludge Pump S2 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DCS network via comm link
FAL.192 Sludge Pump S3 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DCS network via comm link
FAL.193 Sludge Pump S 1 0 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
FAL.I94 Sludge Pump S 1 1 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
FAL-224 Sludge Pump S4 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
-~---~~ ----- .--
FAL-225 Sludge Pump S5 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alann WWTP OCS DeS network via comm link
FAL-226 Sludge Pump S6 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm I WWTP OCS DeS network via comm link
FAL-227 Sludge Pump S7 Low EXISTING i Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
FAL-228 SIudge Pump S.7R Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
FAL-229 Sludge Pump S8 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
FAL-230 SIudge Pump S9 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DCS network via comm link
-~-----~- .----
FAL-231 Sludge Pump S-9R Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DCS network via comm link
FAL-234 Sludge Pump S12 Low i EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
FAL-235 Sludge Pump S13 Low 1 EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm ' WWTP OCS DeS network via comm link
FAL.236 Sludge Pump S15 Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Flow Alarm WWTP OCS DeS network via comm link
FT-101 Influent Flow EXISTING Flow Transmitter Greenwood COMM Analog data obtained from exist
WWTP OCS DeS network via comm link
FT.l02 Effluent Flow EXISTING Flow Transmitter Greenwood COMM Analog data obtained from exist
WWTP OCS DeS network via comm link
---- -,^ EXISTING --.--, "
FT-108 Effluent Screen Flow Flow Transmitter Greenwood COMM Analog data obtained from exist
WWTP OCS DeS network via comm link
FT-203 WAS. Sludge Out Flow EXISTING I Flow Transmitter Greenwood COMM Analog data obtained from exist
WWTP OCS DeS network via comm link
FT-204 OAF.T. Primary Sludge EXISTING Flow Transmitter Greenwood COMM Analog data obtained from exist
~OUtflow WWTP OCS DCS network via comm link
___ _____._____ 1-_ , --------
Station Instrument Index Report
OB/13/2001 05:43 PM
- ~
-
.0<__.
STATION NO: 1184
NIGHT DISPATCHER
FT-205kress NO.1 Sludge EXISTING Flow Transmitter! Greenwood "!COMM'AOalog data obtained from exist 1
, i
Inflow WWTP Des Des network via comm link
--- --- -------- Flow Transmitter i--GreenWOOd COMM Analog data obtained from exist
FT-206 Belt Press NO.2 Sludge EXISTING
Inflow WWTP DeS Des network via comm link
FT-207 Primary Digester No.2 EXISTING Flow Transmitter Greenwood COMM Analog data obtained from exist
Sludge Inflow WWTP OCS OCS network via comm link ~
FT-208 Primary Digester No. 3 EXISTING Flow Transmitter Greenwood COMM Analog data obtained from exist
Sludge Inflow i WWTP OCS DeS network via comm link
FT .209 Primary Digester NO.1 EXISTING Flow Transmitter I Greenwood COMM Analog data obtained from exist
Sludge Inflow WWTP OCS Des network via comm link
FT-21 0 Secondary Digester EXISTING Flow Transmitter Greenwood COMM Analog data obtained from exist
Sludge Inflow WWTP OCS DeS network via comm link
FT-211 Belt Press Back-Up EXISTING Flow Transmitter t Greenwood COMM Analog data obtained from exist
Sludge Inflow WWTP OCS DeS network via comm link
~~216 "'-- ._------~
Splitter Box No.2 Flow EXISTING Flow Transmitter Greenwood COMM Analog data obtained from exist
i WWTP OCS DCS network via comm link
IT.261 Blower No. 1 Motor EXISTING 4-20mA Current Sensor ! Greenwood COMM Analog data obtained from exist
Current WWTP OCS DCS network via comm fink
IT-262 Blower No.2 Motor EXISTING 4-20mA Current Sensor Greenwood COMM Analog data obtained from exist
Current WWTP OCS DCS network via comrn link
I
IT-263 Blower No.3 Motor EXISTING 4-20mA Current Sensor Greenwood COMM Analog data obtained from exist
Current WWTP OCS DCS network via comm link
IT-264 i Blower No.4 Motor EXISTING 4-20mA Current Sensor Greenwood COMM Analog data obtained from exist
Current WWTP OCS DCS network via comm link
JS.1184Z I RTU Ctr1 Pwr Failure NEW 120VAC Digital Input RTU Panel 01
--KI.174 I - EXISTiNG c-- --_.,- COMM Alarm status obtained from exist ---
Grit Washer Timer On Local Control Panel Timer Greenwood
WWTP OCS DCS network via comm link
LS-l11 Wet Well Low Level EXISTING Float Switch Greenwood COMM Status indication obtained from
WWTP DCS exist DCS network via comm link
~ Lift Station 1 st Pump Start EXISTING Float Switch I Greenwood COMM Status indication obtained from
WWTP OCS exist DCS network via comm fink
LS-113 Lift Station 2nd Pump EXISTING Float Switch I Greenwood COMM Status indication obtained from ,
,
Start WWTP OCS exist DCS network via comm link
LS-114 Lift Station 3rd Pump EXISTING Float Switch Greenwood COMM IStatUS indication obtained from
Start WWTP OCS exist DCS network via comm link
LS-115 ~ Lift Station 4th Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
Start WWTP OCS exist DeS network via comm link
---~-- . EXISTING-- -- Float S'witch --- ---o..-~ COMM - -.-
LS-116 Lift Station 5th Pump Greenwood Status indication obtained from
, Start WWTP OCS exist DCS network via comm link
LS-117 Lift Station 6th Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
Start i WWTP OCS exist DCS network via comm link
LS-118 Lift Station 7th Pump EXISTiNG Float Switch Greenwood COMM Status indication obtained from
Start WWTP DCS exist DCS network via comm link
LS.119 Lift Station 8th Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
Start WWTP OCS exist DeS network via comm link
LS.120 Lift Station 9th Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
, Start WWTP OCS exist DCS network via comm link i
LS-121 Lift Station 10th Pump EXISTING Float Switch Greenwood COMM Status indication obtained from I
Start WWTP OCS exist DCS network via comm link '
-- -----L-----___..___._ - -- . ---- -. -- J- Status indication obtained from ~
LS-123 RAS Restore Low Level EXISTING Float Switch Greenwood COMM
WWTP OCS exist DCS network via comm link i
LS.163 Non Potable Water Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
1 Restore WWTP OCS exist DCS network via comm link
LS-165 Non Potable Water Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
2 Restore WWTP OCS exist DCS network via comm link
Sludge Pump S6 & S8 .
LS-238 EXISTING Float Switch Greenwood COMM Status indication obtained from
Restore Level L WWTP OCS exist DCS network via comm link
L. _.__ _ -----.--- ----~ - - -- - -- - - -..----.-- ~~---
Station Instrument Index Report
08/13/2001 05:43 PM
II
.
STATION NO: 1184
NIGHT DISPATCHER
LSH-126 Bar Screen Wet Well EXISTING Float Switch Greenwood COMM Status indication obtained from ~
High Level Overide WWTP OCS exist DeS network via comm link
LSH-135 Effluent Screen High EXISTING Float Switch Greenwood COMM Status indication obtained from
Level WWTP OCS exist DeS network via comm link
LSH-237 Sludge Pump S6 & S8 EXISTING Float Switch Greenwood COMM Status indication obtained from
High Level WWTP OCS exist DeS network via comm link
LSH-280 Daft Pressurization Tank EXISTING Float Switch Greenwood COMM Status indication obtained from
Hi level WWTP OCS exist DeS network via CQmm link
LSL-124 Ras Low Level Float EXISTING Float Switch Greenwood COMM Status indication obtained from
Switch WWTP OCS exist DeS network via comm link
LSL-I64 Non Potable Water Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
1 Low Level WWTP OCS exist DeS network via comm link
LSL-166 Non Potable Water Pump EXISTING Float Switch Greenwood COMM Status indication obtained from
2 Low Level WWTP OCS exist DCS network via comm link
Sludge Pump S6 & S8 EXISTING __,_. __._..._ __..___H
LSL.239 Float Switch Greenwood COMM Status indication obtained from
low level WWTP OCS exist DCS network via comm link
LT.212 Primary Digester No. 1 EXISTING level Transmitter Greenwood COMM Analog data obtained from exist
Level WWTP OCS DCS network via comm link
LT-213 Primary Digester No.2 EXISTING level Transmitter Greenwood COMM Analog data obtained from exist
level WWTP OCS DCS network via comm link
LT-214 Primary Digester No.3 EXISTING level Transmitter Greenwood COMM Analog data obtained from exist
level WWTP OCS DCS network via comm link
LT-215 Secondary Digester level EXISTING level Transmitter Greenwood COMM Analog data obtained from exist
WWTP OCS DCS network via comm link
PAH-191 Sludge Pump S2 High EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Pressure Alarm WWTP OCS DCS network via comm link
---
PAH-192 Sludge Pump S3 High EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Pressure Alarm WWTP OCS DCS network via comm link
PAH-193 Sludge Pump S 1 0 High EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Pressure Alarm WWTP OCS DCS network via comm link
PAH-194 Sludge Pump S11 Hi9h EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Pressure Alarm WWTP OCS DCS network via comm link
PS-181 Effluent Structure Low EXISTING Pressure Switch Greenwood COMM Alarm status obtained from exist
Press WWTP OCS DCS network via comm link
PS-182 Effluent Structure Switch EXISTING Greenwood COMM Status indication obtained from
lead On WWTP OCS exist DCS network via comm link
PS-183 Effluent Structure Switch EXISTING Greenwood COMM Status indication obtained from
Valve Closed WWTP OCS exist DCS network via comrn link
PS-I64 Effluent Structureswitch EXISTING Greenwood COMM Status indication obtained from
Valve Open WWTP OCS exist DCS network via comm link
PS-185 Effluent Structure Switch EXISTING Greenwood COMM Status indication obtained from
Lag Off WWTP OCS exist DeS network via comm link
PS-186 Effluent Structure Switch EXISTING Greenwood COMM Status indication obtained from
lead Off WWTP OCS exist DCS network via comm link
PS-217 Blower NO.1 Filter EXISTING I Pressure Switch Greenwood COMM Status indication obtained from
Pressure WWTP DCS exist DeS network via comm link
PS.218 Blower NO.2 Filter EXISTING Pressure Switch Greenwood COMM Status indication obtained from
Pressure WWTP OCS exist DCS network via comm link
"""PS-219 Blower No.3 Filter EXISTING Pressure Switch Greenwood COMM Status indication obtained from
Pressure WWTP DCS exist DCS network via comm link
.- --_.- =-c-.-----.
PS-220 Blower No.4 Filter EXISTING Pressure Switch Greenwood COMM Status indication obtained from
Pressure WWTP OCS exist DCS network via comm link
PS.221 Blower System Low EXISTING Pressure Switch Greenwood COMM Status indication obtained from
Pressure WWTP OCS exist DCS network via comm link
-""XA.135 Effluent Screen Overload EXISTING Ammeter Relay Switch Greenwood COMM Alarm status obtained from exist
WWTP OCS DCS network via CQmm link
XA.136 Secondary Digester EXISTING PLC Output Greenwood [COMM Alarm status obtained from exist
Blowers Alarm WWTP DCS DeS network via comm link
---------- ------ j ---------
Station Instrument Index Report
08/13/2001 05:43 PM
-
.
..
-
STATION NO: 1184
NIGHT DISPATCHER
~.,. COMM Status indiCation obtained from
YI.133 Final Clarifier No.1 Run EXISTING Motor Starter N.D. Aux Greenwood
Status Contact WWTP OCS exist DeS network via comm link
Final Clarifier No.2 Run ----- ._-~
YI.134 EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
YI-135 Effluent Screen Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from I
Status Contact WWTP OCS exist DeS network via comm link
YI-141 Pump #1 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DeS network via comm link
YI-142 Pump #2 Run Status EXISTING I Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DeS network via comm link
YI-143 Pump #3 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DeS network via comm link
YI-144 Pump #4 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-145 Pump #5 Run Status EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-146 Pump #6 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-147 Pump #7 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-148 I Pump #8 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact , WWTP OCS exist DCS network via comm link
YI-149 Pump #9 Run Status EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI.150 Pump #10 Run Status i EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-151 RAS Pump 1 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from !
Contact WWTP OCS exist DCS network via comm link
YI-152 RAS Pump 2 Run Status EXISTING Motor Starter N.D. Aux Greenwood ,COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-153 RAS Pump 3 Run Status i EXISTING Motor Starter N.D. Aux Greenwood CDMM 'Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI.I54 RAS Pump 4 Run Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS I exist DCS network via comm link
YI-155 RAS Pump 5 Run Status EXISTING Motor Starter N.Q. Aux Greenwood COMM Status indication obtained from
I Contact WWTP OCS exist DCS network via comm link
I
YI-157 Recycle Timer Dn Status EXISTING i Greenwood COMM Status indication obtained from
WWTP OCS exist DCS network via comm link
~. COMM
YI-161 Non Potable Water Pump EXISTING Motor Starter N.D. Aux Greenwood Status indication obtained from
1 Run Status Contact WWTP OCS exist DCS network via comm link
YI-162 Non Potable Water Pump EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
2 Run Status Contact WWTP OCS exist DCS network via comm link
YI.171 Bar Screen No. 1 Run EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
YI-I72 Bar Screen NO.2 Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
YI-173 Bar Screen Conveyor EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Run Status Contact WWTP OCS exist DCS network via comm link
YI.174 Grit Washer Status EXISTING Greenwood COMM Status indication obtained from I
WWTP OCS exist DCS network via comm link
-. -
YI.175 Ddor Unit Blower NO.1 EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Run Status Contact WWTP OCS exist DCS network via comm link
YI-176 Ddor Unit Blower No.2 EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Run Status Contact WWTP OCS exist DCS network via comm link
YI-177 Primary Clarifier No.4 EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Run Status Contact WWTP OCS exist DCS network via comm link
YI-191 Sludge Pump S2 Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
L--_ _ __-------L-__ -- ----- -- u __L-__ . - ---- ----, ----
Station Instrument Index Report
08/13/200105:43 PM
STATION NO: 1184
NIGHT DISPATCHER
--..- .--
YI.192 SIudge Pump S3 Run EXISTiNG Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
YI-193 Sludge Pump S 1 0 Run EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
YI-194 Sludge Pump S 11 Run EXISTiNG Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via CQmm link
YI.224 Sludge Pump S4 Run EXISTiNG Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
YI-225 SIudge Pump S5 Run EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
Yi-226 Sludge Pump 86 Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
YI-227 Sludge Pump S7 Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP DCS exist DCS network via comm link
YI-228 SIudge Pump S-7R Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
YI-229 Sludge Pump S8 Run EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
YI-230 Sludge Pump S9 Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
YI-231 Sludge Pump S.9R Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
, Status Contact WWTP OCS exist DCS network via comm link
,
YI-234 Sludge Pump S 12 Run EXISTiNG Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
YI-235 Sludge Pump S 13 Run EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
; Status Contact WWTP OCS exist DCS network via comm link
i _._.~
YI-236 SIudge Pump S 15 Run EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DCS network via comm link
i YI-241 Sample Grinder Pump EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from ,
SG-1 Run Status Contact WWTP OCS exist DCS network via comm link
1._. YI-242 Sample Grinder Pump EXISTiNG Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
SG-2 Run Status Contact WWTP OCS exist DCS network via comm link
YI-243 Sample Grinder Pump EXISTiNG Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
SG-3 Run Status Contact WWTP OCS exist DCS network via comm link
YI.244 Sample Grinder Pump EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
SG-4 Run Status Contact WWTP OCS exist DCS network via comm link
YI-245 Sample Grinder Pump EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
SG-5 Run Status Contact WWTP OCS exist DCS network via comm link
YI.246 Sample Grinder Pump EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
SG.6 Run Status Contact WWTP OCS exist DCS network via comm link
YI-257 Pressurization Pump Pp- EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
1 Run Status Contact WWTP DCS exist DCS network via comm link
YI.258 Pressurization Pump Pp- EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
2 Run Status Contact WWTP OCS exist DCS network via comm link
YI.261 Blower No. 1 Status EXISTING Motor Starter N.Q. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-262 Blower No.2 Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
I-- Greenwood COMM Status indication obtained from
YI.263 Blower NO.3 Status EXISTING Motor Starter N.D. Aux
Contact WWTP OCS exist DCS network via comm link
c----
Yi-264 Blower No.4 Status EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-265 Settled Sludge Collector EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
I ST -2 Run Status Contact WWTP OCS exist DCS network via comm link
YI-266 T Daft Screw Conveyor EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from I
Run Status Contact WWTP OCS exist DCS network via comm link
_.
YI-267 Surface Skimmer ST-1 EXISTiNG Motor Starter N.D. Aux Greenwood COMM Status indication obtained from I
Run Status Contact WWTP OCS exist DeS network via comm link
---.----.- --.-- ----- '. --
Station Instrument Index Report
08/13/200105:43 PM
STATION NO: 1184
NIGHT DISPATCHER
YI.275 PC-1 Scum Pump Run EXISTING Motor Starter N.D. Aux . ,-,. - --
Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
--- ..-
YI-276 PC-2 Scum Pump Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
Yi-277 PC-3 Scum Pump Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS exist DeS network via comm link
Yi-278 PG-4 Scum Pump Run EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
,
Status Contact WWTP OCS exist DeS network via comm link
YI-292 Gas Compressor C-2 EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Run Status I Contact WWTP OCS exist DeS network via comm link
YI-293 Gas Compressor C-3 EXISTING Motor Starter N.D. Aux Greenwood COMM Status indication obtained from
Run Status Contact WWTP OCS exist DeS network via comm link
YI-301 Primary Clar NO.1 Status EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
_ .J____ .-
YI-302 Primary Clar NO.2 Status EXISTING Motor Starter N.O. Aux I Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-303 Primary Clar NO.3 Status EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Contact WWTP OCS exist DCS network via comm link
YI-304 Grit Pump No. 1 Run EXISTING Motor Starter N.O. Aux Greenwood COMM Status indication obtained from
Status Contact WWTP OCS :exist DCS network via comm link
YI-305 Grit Pump NO.2 Run EXISTING Motor Starter N.O. Aux , Greenwood COMM I~tatus indication obtained from
Status Contact i WWTP OCS !exist DCS network via comm link
YI-30e Gas Lift Compressor C-1 EXISTING Motor Starter N.O. Aux i Greenwood COMM Status indication obtained from
Run Staus Contact I WWTP OCS exist DCS network via comm link
ZA-177 Primary Clarifier No.4 EXISTING Motor Starter N.O. Aux Greenwood COMM Alarm status obtained from exist
Torque Overload , Contact WWTP OCS DCS network via comm link
---. --.--.----- - --- I ---- ---..-
ZA-301 Primary Clar NO.1 EXISTING : Torque Switch Greenwood COMM Alarm status obtained from exist I
Torque OIL WWTP OCS :DCS network via comm link I
I
ZA-302 Primary Clar NO.2 EXISTING Torque Switch Greenwood COMM !Alann status obtained from exist
Torque OIL I WWTP OCS !DCS network via comm link
ZA-303 Primary Clar No.3 EXISTING Torque Switch ! Greenwood COMM Alarm status obtained from exist
Torque OIL I WWTP OCS DCS network via comm link
ZS-127 Bar Screen Conveyor EXISTING Umit Switch I Greenwood COMM Status indication obtained from
Hatch Switch I WWTP OCS exist DCS network via comm link
ZS-128 Bar Screen Conveyor EXISTING Limit Switch Greenwood COMM Status indication obtained from
Hatch Switch WWTP OCS exist DCS network via comm link
ZS.129 Bar Screen Conveyor EXISTING Limit Switch Greenwood COMM Status indication obtained from
Hatch Switch WWTP OCS exist DCS network via comm link
- -----.- -. .-.-
ZS-130 Bar Screen Conveyor EXISTING Limit Switch Greenwood COMM Status indication obtained from
Hatch Switch WWTP OCS exist DCS network via comm link
ZS-133 Final Clarifier No. 1 EXISTING Torque Switch Greenwood COMM Status indication obtained from
Torque OIL WWTP DeS exist DCS network via comm link
ZS-134 I Final Clarifier No.2 EXISTING Torque Switch Greenwood COMM Status indication obtained from
Torque OIL WWTP DeS exist DCS network via oomm link
ZS-171 Bar Screen No. 1 Torque EXISTING Torque Switch Greenwood COMM Status indication obtained from
OIL WWTP OCS exist DCS network via oomm link
ZS.I72 Bar Screen No.2 Torque EXISTING Torque Switch Greenwood COMM Status indication obtained from
OIL WWTP OCS exist DeS network via comm link
ZS.173 Bar Screen Conveyor EXISTING Torque Switch Greenwood j COMM Status indication obtained from
Torque OIL i WWTP OCS exist DCS network via comm link
~-_._,-- -- --. --- ..-----------
Station Instrument Index Report
08/13/200105:43 PM
,-
-
-
-
-
1. THIS PICTURE IS OF THE OFFICE/CONTROL BUILDING AND IS FOR
INFORMATION ONLY. THERE IS NO DEMOLITION WORK AT THIS SITE.
"
'"
"!
o
:>
w
o
.
'"
II II Ii II CORPIJS CHRISTI. IX. (361) ",-,,,.
II I [l PASO. TX (915) 534-9110
SAlT l.AK[ CITY, UT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEwATER DEPT.
PROJECT NO. 7100
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
NO. 1184-NIGHT DISPATCHER (GREENWOOD)
DR: DAILEY DATE: 03/2000 SHEET 1 OF 2
.
.
~
1
1
L
1
L
L
L
J
L
L
1
1
L
1. THIS PICTURE IS OF THE OFFICE/CONTROL BUILDING AND IS FOR
INFORMATION ONLY. THERE IS NO DEMOLITION WORK AT THIS SITE.
j
~
o
N
"
:>
w
"
.
'"
L
II II Ii II CORPUS CHRISTI. IX. (361) ",-,,,.
II I n PASO. TX (915) 534-9110
SAlT lAKE CITY, uT. (801) 261-1455
ENGINEERING CORPORATION
CITY OF CORPUS CHRISTI
WASTEWATER DEPT.
PROJECT NO. 7100
L
I
JOB NO.: 1075
SCALE: N.T.S.
MICROWAVE COMMUNICATION SYSTEM
CONSTRUCTION PHOTOGRAPH
NO. 1184-NIGHT DISPATCHER (GREENWOOD)
DR: DAILEY DATE: 03/2000 SHEET 2 OF 2
.