Loading...
HomeMy WebLinkAbout032078 RES - 03/31/2020 Resolution authorizing a 12-month extension of a Wastewater Trunk Main Line Construction and Reimbursement Agreement for installation of a Wastewater Trunk Main Line and Lift Station with Braselton Custom Homes LTD for a planned residential development called London Towne located on CR-33 WHEREAS, a Wastewater Trunk Main Line Construction and Reimbursement Agreement expires on April 30, 2020. BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF CORPUS CHRISTI, TEXAS: SECTION 1. The City Manager or designee is authorized to execute a 12 month extension of the Wastewater Trunk Main Line Construction and Reimbursement Agreement for $4,266,283.53 expiring on April 16,2020 with Braselton Custom Homes LTD. 032078 SCANNED PASSED AND APPROVED on the ..745+ day of 1`1\C th , 2020: Joe McComb Roland Barrera14Y-- Rudy Garza 4-11Q Paulette M. Guajardo . Gil Hernandez Michael Hunter Ben Molina Q Everett Roy C Greg Smith ATTEST: CITY OF CORPUS CHRISTI Re ecca Huerta o- McComb City Secretary a or Page 1 of 1 032078 AMENDMENT OF WASTEWATER TRUNK MAIN LINE CONSTRUCTION AND REIMBURSEMENT AGREEMENT This is an amendment to the Wastewater Trunk Main Line Construction and Reimbursement Agreement, attached hereto as Exhibit A and made a part hereof, originally dated May 8 ,2018, by and between: Braselton Custom Homes, LTD and the City of Corpus Christi. NOW, THEREFORE, in consideration of the mutual covenants herein, the Parties agree to amend Wastewater Trunk Main Line Extension Construction and Reimbursement Agreement, Section 5 and Exhibit 3 as follows: 5. DEVELOPER AWARD CONTRACT FOR IMPROVEMENTS Developer shall award a contract and complete the Wastewater Extension, under the approved plans and specifications, by April 30, 2021. Exhibit 3. An update to the plans for the 18-inch gravity main and lift station access road have been provided and an update to the quantities of material required of the installation of the 18-inch gravity main line and lift station access road have been provided. All other terms and conditions of the original agreement remain effective end in full force. EXECUTED IN ONE ORIGINAL and made effective this_da f , 2020. CITY OF CORPUS CHRISTI BRA, ON CUS,i2 ' • ' , , TD 1# A, Al Raymond III Bar':raselton, Director of Development Services President APPROVED AS TO FORM: Buck Brice (date) Assistant City Attorney for the City Attorney .►�� SUZANNEHaNEA t'�^ Notary IO C30560604 716 My Commission Expires ?ori. February 29,2024 STATE OF TEXASp § COUNTY OF t v L ceS § Alf1 / fiThis instrument was acknowledged before me on day of i , 2020, by Bart Braselton, President, Braselton Custom omes,�LTD, A Texas • • ration, on behalf of Braselton Custom Homes, LTD. mr •tary •ublic's Signa re ' 1 • D EL'- ---- n 1 ' It • I a ani ', I O Li ' _�Y�r' �I. I :. ( ■ i' ,HAh W..Mom) I ! I ■ k MilI 1 f Y O ' 1 ' i 140«7 ' ,� If � II 11 w / JI ce; 1_�:: �� . .�..,. D- n...4 11 7 I jr �fw�l 70'1'11. ` in._ _ I 1 1 1 T ;„ � - wf Y.-'� •. I .i N -....."—:111-__ wrr —1111 �_ .-1 . . , -. .: �'*'Q�a. - 211 � '._ .s—r _ s�rr— arf _11=1 _ .P1�' ..., � '�iii � .. UM■ iliII II —r 1 I wpl .g...• a fT1+T1 114.111.011 — 080013 1 '1 III -I I I I I. .I 1s 1. 13 ,: II 10 I ■ ■ 01001 4 7 ■ III �•. . ... I 1 M _j 0 www -�- - .3 I • i i11- II• 1i t 1 ti I C `t f W !I ot II. �- I MIS 0 1 ..ar. • ..Di W r. 1 0:01- 1 _ w��1 fM1 r r 1a > r r"— r--aj r r +. 1� 1 1 1i Ir r- tari% .OLYA .,J.1 4 I E I) . .._^. H aat mos '. :�" Svt3 Itidb snuim an'-I:1e: i L mI 1 �n :A1-1. IR (iN�L1p�4f 13N1833NIaN3 31 142 ei. ,,, ,� '',;01C".3.;" �L�, JADAY11131Y M ON 1YM NV@� H •-4 .44.61. ■N V I I:,5. 1..-3r 3 4€4 11 t- I , ■ ■ . ■ ■ �n I n ■ im� ■I* n� ■ ■ si , t I I I 1 IIs 11111 1 s i ii i'' 1 11 i _rwa : Filli 11 h FJ-- . II 1• .14,,,, VI irc. 11 15 1 111 , RP I n a itiu i n_ t. -1,.......„ a d uuww ' i iol,,,, I1 rit Q t -- ' 1: /- . • , \ ! . / —%1e. 4•,,r3-- ',..,„.,4 :, ' 1 f •1 i •P' .) i dir a, :Ai .1 4 'WI- 1J/ ii } r ii lIIa- , ll ' _Ts ' r -f-„ ,.1 • N , _ - ......________ in,-....•....-,-.-1,--'i'4.- '''•• '4r 2 7 .& «NH..,_ t- J it Ognaly signed by Pablo G Martinez.P.C..C P M. •Pablo G. OV:(n•PabOG.M..".• '�.*:[7��� PE,CPM. 15 Martinez o.O d°Prnents"'"e` - a a1-land Derctopncnt. + _ J, email.PaMOMspc<teaas. 1 1 P.E., C.P.M•Date219 Oats 10,9 n1i,aala9 1} (_ wk,m4.._ _ n .u, KEY MAP i i 41 • cinDsi — t (ti� a t •I [111 a.gint•.4..4.I.441 I,. — —• -----0114).- Z z BLOCK 17 I Q CL q� ♦J J -`- 4 �...„„- `--tea -.,..4__ 15V.t.(Doc. No. o. '.t+a. 0 1 k 19 7 L - f lltili .="yr r'�a—_ss ss�=--mss--�- la 9"2"412M �—_ss -a=-_ss -. � .....___..i pp $ pa _.�___ _�_�-� . .«« urn -T R`�. , ] _ �.n-" ~_ ' �-at ,, . , Wit`_ -- 4 -� hr — ♦ IV.L I MdG�'�WW1 i]IfYA ef'AW 1111119 0.`^"1� 1-4:M) - AWN..�� .aa:+ `{Sd) 1 Cl�-- - ) — — �Q� r IW 110 Fif AS iR StIAM aCCtS q MO --V- -- , Q - 5 N , I 1 Mil �: a . BLOCK l0 ( 1 o"'" __ €�a_ s== - ------ -- --- - -- - ------------ I # — -- Z ta lit ii t Z ids (7 s�, i ' . Z :r- w ,; 5 ,a CF 4 O a r.r�K •..• •!WO 19 G5 Wastewater Trunk Main Line Extension Construction and Reimbursement Agreement amendment to Exhibit 3. Additional quantities added to origional agreement. E. MISCELLANEOUS ITEMS 6 1"Water Service to Lift Station CO#2 55 LF 7 3/4 Inch Hose Bib CO#2 1 EA 8 Pump Storage CO#2 12 MO 9 Re-Mobilize CO#2 1 LS F. LONDON TOWNE UNIT 1 SANITARY SEWER 1 18" PVC SDR 26 (24'to 26' Cut) 498 LF 2 18" PVC SDR 26 (22'to 24' Cut) 885 LF 3 18" PVC SDR 26 (20' to 22' Cut) 386 LF 4 OSHA Trench Protection 1,769 LF 5 Embedment 1,769 LF 6 De-Watering 1,769 LF 7 5' Diameter Drop Manhole (20'to 22' Deep) 1 EA 8 5' Diameter Drop Manhole (22' to 24' Deep) 3 EA 9 5' Diameter Manhole (24' to 26' Deep) 1 EA 10 18" Sewer Cap 1 EA 11 Tie to Ex. 18" SDR-26 stub-out 1 EA Doc40 2018021586 WASTEWATER TRUNK MAIN LINE EXTENSION CONSTRUCTION AND REIMBURSEMENT AGREEMENT STATE OF TEXAS § § COUNTY OF NUECES § This Wastewater Collection Line Extension Construction and Reimbursement Agreement ("Agreement") is entered into between the City of Corpus Christi ("City"), a Texas home-rule municipality, and Braselton Custom Homes, Ltd. ("Developer"), a Texas Limited Partnership. WHEREAS, the Developer, in lieu of submitting a plat, has submitted a Land plan which is to be platted and developed in the future, to wit: 118 Acres existing outside the City Limits, as shown in the attached Exhibit 1, the content of such exhibit being incorporated by reference into this Agreement. WHEREAS, under the UDC, the Developer is responsible for construction of the wastewater collection line extension ("Wastewater Extension"); WHEREAS, under the UDC, the Developer is eligible for reimbursement of the Developer's costs for the construction of Wastewater Extension; WHEREAS, it is to the best interest of the City that the Wastewater Extension be constructed to its ultimate capacity under the City's applicable Master Plan; WHEREAS, Section 8.5.2.E.2 of the UDC authorizes the acceptance of applications to be eligible for reimbursement in the future when funds become fully available in the Wastewater Trunk System Trust Fund and are appropriated by the City Council; and WHEREAS, the Developer has submitted an application for reimbursement of the costs from the Wastewater Trunk System Trust Fund for installing the Wastewater Extension, as shown in Exhibit 2, the content of such exhibit being incorporated by reference into this Agreement. NOW, THEREFORE, in consideration of the mutual promises and covenants contained in this Agreement, the parties do covenant and agree as follows: 1. REQUIRED CONSTRUCTION. Developer shall construct the Wastewater Extension in compliance with the City's UDC and under the plans and specifications approved by the City's Development Services Engineer. 2. PLANS AND SPECIFICATIONS. a. Developer shall contract with a professional engineer, acceptable to the City's Development Services Engineer, to prepare plans and specifications for the Wastewater Extension, as shown in the design memorandum Exhibit 3, the content of such exhibit being incorporated by reference into this Agreement, with the following basic design: 1. Install 8896 linear feet 16-inch PVC force main; (2-6 feet deep) Page 1 of 8 2. Install 1351 linear feet 18" PVC gravity sewer 30 feet deep; 3. Install five (5) 5-foot diameter manholes (28-30 feet depth); 4. Install one (1) 8-foot diameter wet well (30 feet depth); 5. Install lift station pump assembly 6. Install diesel stand by generator 7. Install approximately 1384' of 16" directional bore; 8. Install approximately 10,188 feet of OSHA trench protection 9. Dewatering; 10. Connect to existing waste water treatment plant and; 11. Traffic control; b. The Wastewater Plan indicates a lift station to be located on City property near Oso Creek to take advantage of the natural ground slope and help with extending gravity collection system to the service area boundaries. Exhibit 4 c. The plans and specifications must comply with the City's Wastewater Standards Detail Sheets and Standard Specifications. d. Before the Developer starts construction, the plans and specifications must be approved by the City's Development Services Engineer. e. The wastewater extension plans and specifications must be submitted for review by the City within 45 days of approval of this Agreement by the City Council. 3. SITE IMPROVEMENTS. Prior to the start of construction of the Wastewater Extension, Developer shall acquire and dedicate to the City the required additional public utility easements (Easements"), if any, necessary for the completion of the Wastewater Extension. Where portions of the proposed Wastewater Extension reside on City land, easements necessary for the Wastewater Extension will be granted by the City upon agreement of the metes and bounds. 4. PLATTING REQUIRED. Within 45 days of execution of this agreement, Developer shall submit a master preliminary plat application for future consideration by the Corpus Christi Planning Commission for the area in the Land plan attached in Exhibit 1. 5. DEVELOPER TO AWARD CONTRACT FOR IMPROVEMENTS. Developer shall award a contract and complete the Wastewater Extension, under the approved plans and specifications, within 18 months from the date of the approval of the Wastewater extension plans by the City. 6. TIME IS OF THE ESSENCE. Time is of the essence in the performance of this contract. 7. PROMPT AND GOOD FAITH ACTIONS. The parties shall act promptly and in good faith in performing their duties and obligations under this Agreement. If this Agreement calls for review Page 2 of 8 or inspections by the City, then the City's reviews or inspections must be completed thoroughly and promptly per published timelines. 8. DEFAULT. The following events shall constitute default: a. Developer fails to engage a professional engineer for the preparation of plans and specifications by the 10th calendar day after the date of approval of this Agreement by the City Council. b. Developer's professional engineer fails to submit the plans and specifications to the City's Director of Engineering Services and to the Development Services Engineer by the 45th calendar day after the date of approval of this Agreement by the City Council. c. Developer fails to award a contract for the construction of the Wastewater Extension, according to the approved plans and specifications, within 9 months after the date of approval of this Agreement by the City Council. d. Developer's contractor does not reasonably pursue construction of the Wastewater Extension under the approved plans and specifications. e. Developer's contractor fails to complete construction of the Wastewater Extension, under the approved plans and specifications, within the later of 18 months from the date of City Council approval of this agreement or 18 months from the approval of wastewater extension plans by the City. f. Either the City or the Developer otherwise fails to comply with its duties or obligations under this Agreement. 9. NOTICE AND CURE OF DEFAULT. a. In the event of a default by either party under this Agreement, the non-defaulting party shall deliver notice of the default, in writing, to the defaulting party stating, in sufficient detail, the nature of the default and the requirements to cure such default. b. After delivery of the default notice, the defaulting party has 15 business days from the delivery of the default notice ("Cure Period")to cure the default. c. In the event the default is not cured by the defaulting party within the Cure Period, then the non-defaulting party may pursue its remedies in this section. d. Should the Developer fail to perform any obligation or duty of this Agreement, the City shall give notice to the Developer, at the address stated in section 11,•of the need to perform the obligation or duty and, should the Developer fail to perform the required obligation or duty within 15 business days of receipt of the notice, the City may perform the obligation or duty, charging the cost of such performance to the Developer by reducing the reimbursement amount due to the Developer. e. In the event of an uncured default by the Developer, after the appropriate notice and Cure Period, the City has all its common law remedies and the City may: Page 3 of 8 1. Terminate this Agreement after the required notice and opportunity to cure the default; 2. Refuse to record a related plat or issue any certificate of occupancy for any structure to be served by the project; and/or 3. Perform any obligation or duty of the Developer under this Agreement and charge the cost of such performance to the Developer. The Developer shall pay to the City the reasonable and necessary cost of the performance within 30 days from the date the Developer receives notice of the cost of performance. In the event the Developer pays the City under the preceding sentence and is not otherwise in default under this Agreement, then the Agreement shall be considered in effect and no longer in default. f. In the event of an uncured default by the City after the appropriate notice and Cure Period, the Developer has all its remedies at law or in equity for such default. 10. FORCE MAJEURE. a. The term "force majeure" as employed in this Agreement means and refers to acts of God; strikes, lockouts, or other industrial disturbances; acts of public enemies; insurrections; riots; epidemics; landslides; lightning; earthquakes; fires; hurricanes; storms; floods; washouts; droughts; arrests; civiI disturbances; explosions; or other causes not reasonably within the control of the party claiming the inability. b. If, by reason of force majeure, either party is rendered wholly or partially unable to carry out its obligations under this Agreement, then the party claiming force majeure shall give written notice of the full particulars of the force majeure to the other party within ten (10) business days after the occurrence or waive the right to claim it as a justifiable reason for delay. The obligations of the party giving the required notice, to the extent affected by the force majeure, are suspended during the continuance of the inability claimed but for no longer period, and the party shall endeavor to remove or overcome such inability with all reasonable dispatch. 11. NOTICES. a. Any notice or other communication required or permitted to be given under this Agreement must be given to the other party in writing at the following address: 1. If to the Developer: • Braselton Custom Homes • 5537 Yorktown Corpus Christi, Texas 78413 2. If to the City: City of Corpus Christi Attn: Director, Development Services Department 2406 Leopard Street 78401 P. O. Box 9277 Page 4 of 8 Corpus Christi, Texas 78469-9277 with a copy to: City of Corpus Christi Attn: Assistant City Manager, Business Support Services 1201 Leopard Street 78401 P. O. Box 9277 Corpus Christi, Texas 78469-9277 b. Notice must be made by United States Postal Service, First Class mail, certified, return receipt requested, postage prepaid; by a commercial delivery service that provides proof of delivery, delivery prepaid; or by personal delivery. c. Either party may change the address for notices by giving notice of the change under the provisions of this section. 12. THIRD PARTY BENEFICIARY. Developer's contracts with the professional engineer for the preparation of the plans and specifications for the construction of the Wastewater Extension, contracts for testing services, and contracts with the contractor for the construction of the Wastewater Extension must provide that the City is a third party beneficiary of each contract. 13. PERFORMANCE AND PAYMENT BONDS. Developer shall, before beginning the work that is the subject of this Agreement, execute a performance bond if the contract is in excess of $100,000 and a payment bond if the contract is in excess of$25,000. The performance and payment bonds must comply with Texas Government Code, Chapter 2253. 14. WARRANTY. Developer shall fully warranty the workmanship of and function of the Wastewater Extension and the construction of the Wastewater Extension for a period of one year from and after the date of acceptance of the facilities by the City's Director of Engineering Services and Development Services Engineer. 15. PLATTING FEES. Upon platting, the actual wastewater system lot/acreage fees will be credited in accordance with Corpus Christi Texas Unified Development Code §8.5. 16. REIMBURSEMENT. a. Subject to the conditions for reimbursement from the Wastewater Trunk System Trust Fund, availability of funds, and the appropriation of funds, the City will reimburse the developer the reasonable actual cost of the Wastewater Extension in an amount not to exceed$4,266,283.53 less the wastewater system lot/acreage fees for phase 1 of the master preliminary plat required by this agreement. Reasonable actual costs are attached in Exhibit 5; the contents of such exhibit being incorporated by reference into this Agreement. b. The City agrees to reimburse the Developer on a monthly basis upon invoicing for work performed. The reimbursement will be made no later than 30 days from the date of the invoice. Developer shall submit all required performance bonds and proof of required insurance under the provisions of this Agreement. Page 5 of 8 c. The final 10% of the reimbursement will be held in retention until such time the City accepts dedication of the Wastewater Extension. d. To be eligible for reimbursement, the work must be completed in a good and workmanlike manner and must have been inspected and accepted by the City. The City agrees to conduct periodic inspections and approve the progress of the work at key points during construction. e. In the event that this Agreement is terminated by the City as a result of an uncured default by the Developer and at a time when there has been a partial completion and/or partial payment for the improvements, then the City shall only reimburse the Developer for its costs that were legitimately incurred towards the completion of the improvements that have been inspected and accepted by the City up to the time that the uncured default occurred. 16. INDEMNIFICATION. DEVELOPER/OWNER SHALL FULLY INDEMNIFY, SAVE, AND HOLD HARMLESS THE CITY OF CORPUS CHRISTI, ITS OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS ("INDEMNITEES") FROM AND AGAINST ALL SUITS, CLAIMS, DEMANDS, ACTIONS, LOSSES, COSTS, EXPENSES, LIABILITY, DAMAGES AND JUDGMENTS RECOVERED FROM OR ASSERTED AGAINST CITY FOR ANY AND ALL PROPERTY DAMAGE OR INJURIES SUSTAINED BY ANY PERSON, INCLUDING WITHOUT LIMITATION, WORKERS' COMPENSATION, PERSONAL INJURY OR DEATH, ARISING FROM OR INCIDENT TO, BE CAUSED BY, OR BE IN ANY WAY CONNECTED WITH THE CONSTRUCTION OF THE WASTEWATER EXTENSION. 17. DEVELOPMENT OF LAND. This Agreement is to encourage the development of the land within the boundaries of the London Area Master Wastewater Plan, including initially a section of that portion of Tract II as described in Correction Warranty Deed having DOC#2015011169 containing approximately 118 acres and incorporated herein as EXHIBIT 6 18. ASSIGNMENT OF AGREEMENT. This Agreement or any rights under this Agreement may not be assigned by the Developer to another without the written approval and consent of the City's City Manager. 19. DISCLOSURE OF INTEREST. Developer agrees, in compliance with the City Ordinance No. 17110, to complete, as part of this Agreement, the Disclosure'of Interest form attached to this Agreement as Exhibit 7. 20. EFFECTIVE DATE. This Agreement becomes effective and is binding upon and inures to the benefit of the City and the Developer and their respective heirs, successors, and assigns from and after the date of final execution by all parties. 21. AUTHORITY. The person signing this Agreement on behalf of each of the parties represents, warrants, and guarantees that they have authority to act on behalf of the party and make this Agreement binding and enforceable by their signature. Page 6 of 8 22. TRUSTEE LIABILITY. The City is executing this agreement as trustee of the Wastewater Trunk System Trust Fund pursuant to Corpus Christi Texas Unified Development Code §8.5. It constitutes a promise to pay only to the extent that the assets and future assets of the trust are sufficient for such purpose and it is expressly agreed that any judgment will only be satisfied out of the assets of the trust and not out of the City's assets. The City is excluded from personal liability. 23. PAYMENTS, CREDITS AND DEFERRED REIMBURSEMENT. All payments, credits, priority of reimbursement, and deferred reimbursement shall be made in accordance with Corpus Christi Texas Unified Development Code §8.5. 24. DEDICATION OF WASTEWATER EXTENSION. Upon completion of the construction, dedication of Wastewater Extension will be subject to City inspection and approval. 25. VERIFICATION REGARDING ISRAEL. In accordance with Chapter 2270, Texas Government Code, the City may not enter into a contract with a company for goods or services unless the contract contains a written verification from the company that it: (1)does not boycott Israel; and (2)will not boycott Israel during the term of the contract. The signatory executing this Agreement on behalf of the Developer verifies that the company does not boycott Israel and will not boycott Israel during the term of this Agreement. 26. CERTIFICATE OF INTERESTED PARTIES. Developer agrees to comply with Texas Government Code section 2252.908 and complete Form 1295 Certificate of Interested Parties as part of this agreement. Form 1295 requires disclosure of"interested parties" with respect to entities that enter contracts with cities. These interested parties include: (1) persons with a "controlling interest" in the entity, which includes: a. an ownership interest or participating interest in a business entity by virtue of units, percentage, shares, stock or otherwise that exceeds 10 percent; b. membership on the board of directors or other governing body of a business entity of which the board or other governing body is composed of not more than 10 members; or c. service as an officer of a business entity that has four or fewer officers, or service as one of the four officers most highly compensated by a business entity that has more than four officers. (2) a person who actively participates in facilitating a contract or negotiating the terms of a contract with a governmental entity or state agency, including a broker, intermediary, adviser or attorney for the business entity. Form 1295 must be electronically filed with the Texas Ethics Commission at httpsj/www.ethics.state.tx.us/whatsnew/elf info form1295.htm. The form must then be printed, signed, notarized and filed with the City. For more information, please review the Texas Ethics Commission Rules at httos://www.ethics.state.tx.us/legal/ch46.html. 27. CONFLICT OF INTEREST. Developer agrees to comply with Chapter 176 of the Texas Local Government Code and file Form CIQ with the City Secretary's Office, if required. For more information and to determine if you need to file a Form CIQ, please review the information on the City Secretary's website at http://www.cctexas.com/government/city-secretary/conflict- disclosure/index Page 7 of 8 cYr_ EXECUTED IN ONE ORIGINAL this da of 2018. Y ATTEST: CITY OF CO PUS CHRISTI 441JA__/ Re cca Huerta K ' elman City Secretary Assistant City Manager, designee of the City Manager r APPROVED AS TO FORM: f� v { 16 , 2018 gi •if 01111110 8 B Buck Brice, Assistant City Attorney L For the City Attorney fir' BECRET 1 Develope Braselto ; • Ho/- •= By: B. Braselton ILTRA v PENA STATE OF TEXAS § ;Z ; NOTARY PUBLIC • %: :F' State of Texas -20 1\\ Conrn.x.12-0219 COUNTY OF This instrument was acknowledged before me on A c (2-4k- 2018, by Bart Braselton, President, Braselton Custom Homes, a Texas • • •oration, on behalf of said corporation. rjf. c). • Notary Public's Signature MORANDUM RECORD CLERKS MEERKS NOTE: Error in Acknowledgment Page 8 of 8 EXHIBIT I 4 16 `� ' % � i. I ju F _ 1: .:.:,110:47-'.4,4 :: , 3q 'i t ,, r 1� ' �„ to FV F. i�+_"�', . J!�3.}, .i '9a 'F?�, � 9 3Fe? L l !� .:-1 .? . i :TA. fp'3. - .tl:4�_ '.�,3'.. }s f i7'�'` } '1,;'::-..4';:-..-,:i ` 's' t ,moi d�� iYY �4 '�v.. y� � F � q:',7!0,7-"'":: 'b 4-' LF4��u2� :ti # �,y5 5 w 5. 7,:i:..-r' hr 1 d 5 ,Stt 1 :7 .1' E4:!':!',c7:4-..i k C '¢ �. 3 ; sW Ni l '1'•i4144, 74`:•:,41:1. h ` 7 i?7,-::::2:' ,', :;.,44,3,:*::., :1:* Lia :!: _i, I . i #-. 5# i -i. 3 �.' _i'43;,..a '�"r a..'',44Yri;i.- ,� .a a .. :.rte rf�F - :.34'.; E F 8g.�' � i:: '! � -tea t �uT �ley g& � {may{ 5 J s-� i E my� Al' 1..z7:.,!...,!:: µ A — Rit 3 f� ' a5 2 -moi _ F- E '-',_,.: ,,,7g71‘.:5:.-i.:':,..:' !,,,:%;i1N: '4! -:-.i-A.,"1.-'1,e1:,!'"ft.:4;:iV41...,':::!'"-J,.-i!•:„C_'7::::7.. :-;'::.:•-;•.-::,;j:•.•::,:7.:::Z.t7.1.:.� j i'� P'�"(p.-�aa�� � #' �- E 5 �� � �f�i4 � �# � �,p � - t J „,i0;,:;,,,,,,-0i..-.-q0..;,,,.!,41,,, -G�; F - F f>- i'-47 w ; .4 3 h am' iC g A k h.' � S. � -r' � �� ?Z� i �_ � i' '£ 3” :4i SSS FF� .S /: .Rik.F a NC.-7...,.:::.::: F r€ b�' N : -� ay -�.�-2- --' y -: '.. .' iF t .7a 4� Irk - Jtii. i £ ` s s i e# 1 ,,,,., L. _ g fmk P.a '#JI. .y.i,i1.k�, s t-4 - #x' ,� .J: i + � IZ4* mk #=-., .,F '. �' ,z`_ n qk - J ,g yw ?-Hca.E • �'E E �' .;� - .:- -"-7'';.7-'''-4L-':'-'!"7:". ..'.7-''''''' -�" '4 _ rr :-f:',-;,--..-;i,' ro 3 *. ie g '� 41_t 1 ..1.-..' .V;''r.:f.';ft'll;:iti'4 --!'W.0..-'44 tr: ., _-.e4- �. Za _ a - +�. T I . :- - i "` -' e ;3 a : e u 4 -. - _ Q :. # � �� 3» ate _ SY" _ :. �i �c5 ` 7' I i<'I-47_,,,,,-,,77.7.717-4-4,47- 1--- 2 'may . '- .' E '' :ice _— _..s. '7:.-'''': '. -� '. 4 �f =,ate y RE(ORDERS JIE IOR:1.\'D1 11 41 the time 0f ret ardutiar,this ifs7nrnreet M•u-x/01111(1 to he inudeyume• fir tlm hest pinu0grerphie• reprarhu110tr hernuse of illegihilitt'. rarh0n nr photae•rrpr, discolored paper e'tr, •111 hlue•6mds. ahot o0u.s and e•Irarr;'ex M'e're presctp u► theKnee the instrument M'as filed. res orded Exhibit 2 APPLICATION FOR WASTE WATER REIMBURSEMENT We, Braselton Custom Homes LTD., a Texas Partnership, 5337 Yorktown, Corpus Christi,Texas, 78413, owners and developers of proposed London Towne Unit 1 (see attached land plan), hereby request reimbursement of$4,266,283.53 • the installation of the waste water line in conjunction with said lot, as provided for by City • •in ce No. 17396. $4,266,283.53 is the construction cost, including Engineering and Surv- in. as shown b r= cost supporting documents attached herewith. AO.,_,, ,,,rgoor, // /7& Ba `='!v-�on, ;1resident Da e Br, -elton Custom Homes, LTD. THE STATE OF TEXAS § COUNTY OF INQ,O.,D § ATi2�This instrument was acknowledged before me on 1 , 2018, by '-c .' 1. 11 ,T 6' �' f" ' , SLA , of Braselton Custom Vomes LTD., a Texas Corporation, on be If of the said corporation. (D !....;;,;77 ... ULTRA V PENAJ-'< \ ,124.-0— Zr ' I NOTARY PUBLITexas NotaryPublic in and for the State of Texas �" '�° �a` State of Texas '�: '' : Comm.Exp.12-02-2019 CERTIFICATION The information submitted with this application for reimbursement has been reviewed and determined to be correct. Reimbursement is subject to: (a) Sufficiency of funds in the Sanitary Sewer Trunk System Trust Fund, and (b) Appropriation and approval by the City Council. // >r• 4, ,: ( '2,..7.4:9/8 Deve pment Services Engineer (Date) Exhibit 3 (391°` t l : :,IIII MEMORANDUM 1862 DATE: April 12, 2018 FROM: David Thomburg Development Services Project Manager (361)826-8451 DESIGN MEMORANDUM UPDATE PURPOSE: The purpose of this is to acknowledge that the design memorandum was prepared prior to the updated Wastewater master plan amendment. DISCUSSION The design memorandum was submitted to Development Services prior to the Wastewater Master Plan Amendment being updated and as such the body of the document has not been altered. The cost estimate and the relative graphic exhibits have been updated to reflect the changes required by the new Wastewater Master plan. All other areas of the design memorandum were not materially affected by the change. • K:\DevelopmentSvcs\SPECIAL SERVICESIAPPLICATIONS FOR LAND SUBDMVIStONti-Brasetton Wastewater Plan and infrastnrcture Construction\Legistar\Design Memorandum Memo.doc 1 Exhibit 3 r ' DESIGN MEMORANDUM For: OCt1810 201 London Area Wastewater Plan Lift Station No. 1 . 19 SEC vs Ghistg November 3, 2017 G`� o{ Gee t SgN1� Revised: November 27, 2017 Devi° Revised: December 18, 2017 Nab A London Area Wastewater Plan-Proposed f 4 Lorna ISA 10.0s MS 144•00/0.40 Simi••••4410.40.01144100•0410144.44 AM edcrr..r .__-__J. Z 000101104410011 w•.I..M..�`u....r•...m.Y 100,01• Wm 1..�. pr.ry 614110/111/ .•s i TABLE OF CONTENTS EXECUTIVE SUMMARY SECTION I INTRODUCTION SECTION II LIFT STATION DESIGN CRITERIA A. SITE SELECTION B. DESIGN FLOW C. WET WELL DESIGN 1. Wet Well Volume 2. Pump Levels 3. Wet Wel Detention D. PUMP HEAD CALCULATIONS E. LIFT STATION EMERGENCY PROVISIONS 1. Storage Capacity 2. Discharge Prevention System F. UTILITIES IN PROJECT AREA G. GEOTECHNICAL INVESTIGATION SECTION III PROPOSED IMPROVEMENTS A. LIFT STATION 1. Pumps and Accessories 2. Wet Well 3. Let Station Discharge Piping and Valves(above ground) 4. Wet Well Ventilation 5. Flow Meter 6. Odor Control 7. Miscellaneous Site Improvements B. FORCE MAIN 1. Force Main Piping 2. Line Valves C. GRAVITY SANITARY SEWER 1. 18"Diameter PVC 2. Manholes EXHIBITS AND APPENDECIES Exhibit'A'—Adopted London Area Wastewater Master Plan Exhibit'B'—Basis of Design Exhibit'C'—Project Overview Exhibit'D'—Opinion of Probable Cost Exhibit'E'—Lift Station Exhibits Appendix'A'—London Area Lift Station 16"Force Main Duty Analysis-Flygt Appendix'B'—Geotechnical Report—Rock Engineering and Testing Laboratory, inc. Appendix'C'—Record of Power Outages for London ISD Area Appendix'D'—Responses to City Comments(sent via email response) London Area Wastewater Plan NESAN Lift station No t ENGINEERING EXECUTIVE SUMMARY The following is the Executive Summary for the plan submission for the London Area Wastewater Plan Improvements. This project Involves the Installation of a wastewater duplex lift station, approximately 1,470 linear feet of 18' gravity sanitary sewer and approximately 10,185 linear feet of 16" diameter sanitary sewer force main (See Exhibit 'C' - Project Overview). The London Area Wastewater Plan was adopted by City Council in April 2017 and provides a wastewater service area for an area south of Oso Creek (see Exhibit 'A'). This system will initially serve a proposed development to the west along County Road 33. Ultimately It will serve all of the area within the London Area Wastewater Master Plan. The London Area Wastewater Master Plan, as adopted, calls for two 15-inch gravity sewer lines to deliver the flow from the entire service area to a common manhole, and then to the proposed lift station via a single gravity sewer line. As the lift station Is proposed to be located approximately in the center of the service area, it is assumed that each of the 15-inch gravity lines would carry approximately half of the total flow. Based on the criteria adopted by the city with the master plan, a 15-inch gravity line does not have sufficient capacity to carry half of the total flow from the service area. Based on that same criteria, an 18-inch gravity line does have sufficient capacity to carry half of the total flow from the service area. An 18-inch gravity sewer line will provide a 40% greater capacity than the 15-inch line, and wiil do so at no additional cost to the city. See the Capacity Calculations Exhibit included with Appendix'D'. The proposed project includes 18" diameter gravity sanitary sewer lines to be built at master plan depths to serve the entire London Area Service Area. The proposed gravity sanitary sewer will start at the new lift station and branch out to serve the proposed development to the west of the lift station. A stub-out will be provided from the lift station to the east for future extension to serve developments on the east side of the London Wastewater Service Area. The proposed gravity sanitary is planned to be constructed along city and private property. Utility easements will be dedicated for all wastewater infrastructure as needed. The material for the gravity sanitary sewer will be PVC(Green, SDR-21). The proposed wastewater lift station is a duplex submersible pump station with an 8'diameter x 30' deep fiberglass wet well. Lift station is designed such that both the Phase 1 and future Phase 2 pumps will function with no changes, other than replacing pumps and control panel. The proposed Phase 1 pumps are 12 horsepower submersible pumps. Future development in this area will dictate when the future Phase 2, 20 horsepower submersible pumps will need to be installed in the lift station. Design of the proposed lift station will follow criteria established by TCEQ in TAC 30 Chapter 217 and will conform to the City of Corpus Christi standards. London Area Wastewater Plan Lift Station No 1 UE ENGINEERING Page ES-1 of 2 EXECUTIVE SUMMARY The proposed lift station will pump into a proposed 18" diameter force main that will be constructed across City property, within the Greenwood Drive right-of-way, and within the Saratoga Boulevard right-of-way,and will discharge into the plant lift station at the Greenwood Wastewater Treatment Plant Utility easements will be dedicated where needed. Design of the force main will follow criteria established by TCEQ in TAC 30 Chapter 217. A portion of the force main will be installed by directional drill across Oso Creek. The material for the drilled portion of the force main will be Fusible PVC (Green, C-900, DR 18, pressure class 235 psi). The Material for the remainder of the force main line will be PVC (Green, C-900, DR 18, pressure class 235 psi). Pipe embedment and trench bacifiD will conform to applicable Cfty of Corpus Christi standards. London Area Wastewater Plan l ifl Station Nois f ENGINEERING Page ES-2 of 2 � SECTION I - INTRODUCTION A. PURPOSE The objective of this report is to Identify, analyze and review design issues relating to this project, develop a work plan and provide recommendations for the new wastewater lift station per the London Area Wastewater Plan. The proposed new sanitary sewer infrastructure includes a gravity sewer system, a lilt station, and a force main. To date there has not been any public wastewater systems to serve this area. This system will initially serve a proposed development to the west along County Road 33. Ultimately it will serve all of the area within the London Area Wastewater Master Plan. B. LONDON AREA WASTEWATER PLAN ADOPTED APRIL 2017 The London Area Wastewater Plan was adopted by City Council in April 2017 and provides a wastewater service area for an area south of Oso Creek. The service area is bounded by Oso Creek on the north, SN 288 on the east,Weber Road on the south, and farmland to the west. See Exhibit A at the back of this report for a map of the Wastewater Plan. Grades for the service area generally drain from south to north (Weber Road to Oso Creek). The Wastewater Plan indicates a lift station to be located on City property near Oso Creek to take advantage of the natural ground slope and help with extending gravity collection system to the service area boundaries. However, the master plan shows gravity sewer coming from the east and west, combining approximately 1,100 feet south of the lift station, and then flowing by gravity sewer north to the lift station. This effectively eliminates any advantage gained by moving the lift station to the lower elevation. Therefore, it Is proposed that the lift station be located approximately 1,100 feet south of the location depicted on the master plan. This will eliminate 1,100 feet of gravity sewer and replace with force main which is considerably more economical. The force main will be constructed from the new lift station northward through city property, and then adjacent to Greenwood Drive terminating at the lift station at the Greenwood Wastewater Treatment Plant. The Wastewater Plan indicates the force • main to be 16'diameter. Branching out from the new lift station to the east and to the west will be gravity sewer lines, as indicated on Exhibit A. The line to the east will be a short stub-out which will be capped for future extension. The line to the west will be installed approximately to west edge of the County Road 33 right-of-way. London Area Wastewater Plan tig Lift Station No 1 ewot�tN Page 1 of 10 t SECTION I - INTRODUCTION C. SITE DEDIC8TT_4N The lift station site will be located on city properly.The gravity collection system will be located on city and private property. The force main will be located on city property, and within dedicated right-of-way. Utility easements will be dedicated for all wastewater infrastructure as needed. Metes and Bounds descriptions with exhibits will be provided for these locations where necessary. • London Area Wastewater Plan UELdt Bratton No 1 ENGINEERINGPage 2 of 10 • SECTION II - UFT STATION DESIGN CRITERIA A. SITE SELECTION The new London Area lift Station No. 1 ail be located on the City's property south of the Oso Creek and wilt be designed such that ft can serve the entire sere area by gravity (See Exhibit A for approved waw plan). Metes and Bounds with aedsiat will be developed for the site that the lift station will encompass. The site will be laige enough to construct the Phase 1 lift station wet well and allow construction of future wet well to expand the pumping capacity. B. 9ESIGN FLOW The design flow for the proposed lift station was calculated by determining the land use for the various parcels of land within the lift station service area per the City's London Area Wastewater Plan (see Exhibit A), applying the master plan flow rate per land use type and then totaling the flows. A peaking factor of three was used, based on the Babbitt formula, and 400 gal ons/dsytacre was added for infiltration. Potential flowrate from the London Independent School District(ISD) property was also added, based on information provided by the school district Exhibit 8 shows mons detailed information of the service area and land use acreage used to develop the design f4ows. Flow calculations are shown in the table on the following page and recommended design flows for this lift station are as follows: Phase 1 Design Flow: 625 GPM (0.90 MGD) Future Phase 2 Design Flow: 1,220 GPM(1.76 MGD) Future(Ultimate)Design Flow: 3,044 GPM(4.38 MGD) The components of the lift station, except for the pumps and control panel, will be sized to handle the Phase 2 design flow of 1.76 MGD(1,220 GPM). The lift station will be designed using Flygt(Xylem)submersible centrifugal pumps. The pump motors will be 3-phase,460V,60 Hz. • Phase 1: NP 3153 LT-3 416 Impellor 12 Hp 669 GPM 32.6'TDH Phase 2: NP 3153 LT-3 413 Impellor 20 Hp 1230 GPM @ 41.8'TDH London Area Wastewater Pian Lift Station No 1 ~ Page 3 of 10 WSW 11111111111■1111WIWI (• SECTION II - UFT STATION DESIGN CRITERIA Phase 1 Uft Station Hqw Calculation' Persons GPO Pot Peak Now Add •.!MO Adak Land Use Per Acre Poem , ac IMh411tyI __ HiP69 1061 109.06 Low Density Ilesidantial gown Tract) 14 100 3 319 30 MP San Regional Sports Complex(per MDR) 21 GPM - 3 14 17 1 50.00 De=Mound Sports Cornelia 30 30 3 94 14 t01t 11.97 London School-Existing Phase I:Awl.•14 GPM • 3 42 23 301.75 539 N I SS 1 1 PH 1 SAYI$WI Phase 2 Lift Statloq Flow Calculations Penises GPO Per Peak Now Add Aata - Land Use Par Awe Person Factor Nihon U3 - 109.06 tow Density ResiOsndal(Brown Tract) 14 100 3 319 30 SO 499 Parks Prawn Tract) 10 20 3 3 2 9 50.72 Ragonal Sports Complex(per FSR) 28 GPM - 3 14 17 101 50.00 Div Arosnd Sports Comperes 30 30 3 94 14 101 11.97 Landon Waal•Existing Masa I:Ay{.•14 GPM - 3 42 23 43 London School-Future Plisse II:"Ng•8 GPM - 3 24 24 135.00 Low Density Residential 14 100 3 394 31 411 13.00 Marium Density Residential 35 100 3 110 5 11 10.00 Commercial 30 30 3 19 3 22. 466.74 10119 132 I 13M $ PH 2 SAY sus OZPM Ultimate lift Station Flow Calculations Persons GPO Per Peak Noor Add TMM Acuate Land Use Per Acre Parson Factor 19191088 IA in 109.06 Low Density Residandal(lrown Tract) 14 100 3 319 30 349 4.99 Parks(Brown Tract) 10 20 3 3 2 S 60.72 Regional Sports Complex(per HDR) 23 GPM - 3 ' 84 17 201, 50.00 .Dew Mound Sports Complex 30 30 3 94 14 s08 11.97 London School-Existing Phase I:Avg.s 14 GPM - 3 42 23 65 London School-Future Phase II:Avg=I GPM - 3 24 24 632.24 Low Density Residential 14 100 3 1,144 176 2.020 43.23 Medium Density Residential 3.5 100 3 316 13 329 19.68 Commercial 30 30 3 37 6 q 1,001.19 2763 211 1 0 `1 ULTIMATE FLOW=3,050 GPM London Area Wastewater Plan Lift Station No 1 IMAM Page 4 of 10 SECTION II - LIFT STATION DESIGN CRITERIA C. WET WELL DESIGN 1. WET WEU,.VOLUME The lift station will be designed using the criteria set forth in TCEQ's Chapter 217 of TAC 30. The primary design consideration for lift stations is given to wet well volume. The wet well volume required is calculated using the formula found in TCEQ Ch 217.60. V=(T• Q)/(4 *7.48) V=Active volume(cubic feet) Q=Pump capacity(gallons per minute) T= Cycle time(minutes) This formula is used to calculate wet well volumes when the pump capacity is equal to the peak flow. For less than 50 Hp motors a pump cycle time of 6 minutes Is required, for 50 to 100 Hp motors a pump cycle time of 10 minutes is required and for greater than 100 Hp motors a pump cycle time of 15 minutes Is required. For future peak flow of 3,044 GPM (4.38 MGD) additional wet well capacity will have to be constructed. A stub-out for an interconnecting pipe between the existing and future wet wells is being provided. The preliminary recommended dimensions for a fiberglass round wet well are: Diameter. 8'-0" Water Depth: 5'-0" (El. 3.00 to El. (-)2.00) Area: 50.3 SF Total Volume: 251 CF (1,877 Gallons) 2. PUMP LEVELS Recommended pump levels based on design flow are provided in the following. High Level Alarm On El. 3.00 Lag Pump On El. 1.60 Lead Pump On El, 0.60 Pumps Off El. (-)2.00 Actual levels will likely vary during initial flows and flow changes will occur over time. Flow should be monitored and changes made in the field as necessary. London Area Wastewater Plan ILE Lift Station No 1 ENGINEERING Page S of 10 SECTION II - UFT STATION DESIGN CRITERIA 3. WET WELL. DETENTION Wet well detention calculations are based on the following previously developed values and the pump curve In the Appendix'A': PHASE 1 Peak Wet Weather Design Flow= 0.90 MGD=625 GPM One Pump On=669 GPM Wet Well Surface Area: 50.3 SF Lead Pump On to Pump Off at 2.6'= 978 Gallons Td a Detention Time In the wet well Td =(978/625) +(978/(669-625))=23.8 min. PHASE 2 Peak Wet Weather Design Flow= 1.76 MGD = 1,220 GPM One Pump On= 1230 GPM Wet WeN Surface Area: 50.3 SF Lead Pump On to Pump Off at 5'= 1,881 Gallons Td =Detention Time in the wet well Td =(1,881/1,220)+ (1,8811(1,230-1,220))=203 min. D. JUMP HEAD CALCULATIONS Pump design is based on the system analysis as presented in Appendix 'A' for one pump running (second pump is backup pump) and with the new 16" dia. force main, The system curve was developed utilizing hydraulic calculations. E. UFT STATION EMERGENCY PROVISIONS 1. STORAGE CAPACITY According to TAC 30 Chapter 217, storage capacity must be provided for 20 minutes of peak flow In the event of a power outage(or equal to the longest power outage in the last 60 months), to prevent the release of untreated wastewater. Nueces Electric Cooperative (NEC) provides power for the lift station site. Since this is a new lift station and a new overhead power supply will have to be constructed, there is no historical information for outages to this lift station. However, NEC has provided power outage information for the London ISD area London Area Wastewater Plan Lift Station No 1 ENOG�NO Page 6 of 10 SECTION II - LIFT STATION DESIGN CRITERIA (see Appendix 'C'). The information provided indicates the longest duration of power outage to the area was over 26-hours during Hurricane Harvey. This duration would result in a storage amount which cannot be contained within the wet well, gravity fines, and manholes. Therefore, a diesel powered back-up generator will be permanently located on site and provided with an automatic transfer switch. The generator will be sized to run one of the two phase 2 lift station pumps for at least 27 hours (one pump is designed to pump the phase 2 peak flow). Generator will be self-starting with the loss of the primary power source. 2. DISCHARGE PREVENTION SYSTEM An audiovisual alarm system consisting of a Supervisory Control and Data Acquisition (SCADA) panel located at the lift station will be provided to communicate station conditions and alarms to the Wastewater Service Center. The alarm system will monitor and provide notification of power outages, pump failures and/or a wet well high water level. F. UTILITIES IN PROJECT AREA C There are no known utilities located in or around the proposed lift station site. There is an existing Enterprise gas pipeline which traverses the city landfill property and runs along Greenwood Drive. The proposed force main will cross the existing gas pipeline just south of the Greenwood Drive terminus at the city landfill property. The proposed force main will be located on the east side of the Greenwood Drive pavement and will run parallel to the above mentioned existing gas pipeline, an existing city gas line, and a small diameter sewer force main. G. GEOTECHNICAL INVESTIGATION Geotechnical investigation of the subsurface materials and conditions was performed at the lift station site, along the route of the force main and along the route of the gravity lines and a study prepared by Rock Engineering & Testing Laboratory, Inc. A copy of the boring log and the results of the soil sample analysis are provided as Appendix 'B'. The soils at the lift station are described as firm to stiff, highly plastic, dark grey to brown clay. Ground water was encountered at four of the six bore holes during the drilling operation and read again 24 hours later and water levels are presented in the soils report pages in Appendix 'B'. Well pointing of some sod will likely be required for some of the construction elements. London Area Wastewater Plan IIURNIAti Lift Station No 1 ENGINEERING Page 7 of 10 SECTION II - LIFT STATION DESIGN CRITERIA The entire geotechnical study will be included with the bidding documents for use by the contractors bidding the project. • London Area Wastewater Pian Lit Station No. 1 ENOh�N Page 8 of 10 SECTION III - PROPOSED IMPROVEMENTS A. UFT STATION 1. Pumps and Accessories The proposed lift station is a duplex lift station, two pumps will be installed, with one pump handling the design flow and the other pump acting es a backup pump. The lift station will initially have 12 Hp Phase 1 pumps. When flows increase and the Phase 1 pumps near capacity future Phase 2 20 Hp pumps can be installed and control panel replaced. 2. Wet Well The proposed wet weU will be 8' in diameter, approximately 30'deep, and made of fiberglass. Active volume with 5'-0" operating level is 251.5 CF (1,881 Gallons). The fiberglass wet well would be constructed with concrete bottom and top slab (note that there is also a fiberglass top to the vessel to protect the top from hydrogen sulfide gasses). One access hatch, wide enough to serve both phase 1 and phase 2 submersible pumps, will be provided in the top of the concrete roof to allow access to the pumps. Access hatches will be provided with safety grating for fall protection when the access door is opened. 3. Lift Station Discharge Piping and Valves(above ground) For ease of maintenance, the proposed lift station isolation and check valves will be installed on top of the station above the top slab. All above ground discharge piping will be constructed with ductile iron pipe and fittings. An emergency bypass connection will be provided on the downstream discharge header with a tee, plug valve and blind flange to allow connection of a temporary pump should the need ever arise to bypass the lift station wet well or due to pump failures. 4. Wet Well Ventilation The proposed lift station will have passive ventilation per TCEQ Chapter 217 Regulations. The passive ventilation will consist of one 8"pipe vent with a stainless steel bird screen over the end. 1.76 MGD=2.72 CFS x 60 Min/Sec= 163 CFM Each Area Required: 163 CFM/500 FPM= 0.33 SF Min. USE ONE 8' DIA. VENT(0.349 SF) 5. Flow Meter The proposed lift station will include a flow meter to measure flow through the discharge piping. The flow meter will be installed in a fiberglass manhole adjacent to the Oft station wet well downstream of the above ground discharge piping. London Area Wastewater Pian Lift Station No I ilE ENGiNG Page 9 of 10 t SECTION III - PROPOSED IMPROVEMENTS 6. Odor Control Since the proposed lift station is brand new and peak flows are minimal, there will be no odor control systems Installed at the lift station site. Space is being provided on the site, though, for a future bio-filter type odor control unit, should the need arise. 7. Miscellaneous Site Improvements • The lift station will be accessible from County Road 33 with construction of a new 12'wide access road from the existing country road to the rd station site. Proposed access road is outside of the boundary of the existing and proposed FEMA 100 year storm event. • For security, the proposed lift station site will have a 8' tail chain link fence with three strands of barbed wire. Access to the new lift station will be through a lockable 3' wide personnel gate and a lockable 12' wide main gate to allow for vehicular entry. • Control panels and wet well access hatches will also be lockable to limit access. • A security light will be provided with dusk till dawn photo cell. B. FORCE MAIN 1. Force Main Piping The proposed 16' diameter sanitary sewer force main will be constructed of PVC (green, C-900, DR 25, pressure class 165 psi). The proposed force main will be installed with a minimum of 2'-6"of ground cover. 2. Line Valves Line valves for isolation of the force main will be installed at maximum 2,000' intervals. C. GRAVITY SANITARY SEWED 1. 18" Diameter PVC All proposed PVC gravity lines will be installed at master plan depths. 2. Manholes Manholes for this project will be spaced at a maximum of 500' apart per TCEQ Chapter 217 requirements. Manhole wall thickness and construction will conform to City of Corpus Standard Details and Specifications. London Area Wastewater Plan Lift Station No 1 II ENGINEERING Page 10 of 10 • EXHIBITS Exhibit'A'-Adopted London Area Wastewater Master Plan Exhibit'B'- Basis of Design Exhibit'C'-Project Overview Exhibit'D'-Opinion of Probable Cost Exhibit'E'-Lift Station Exhibits t London Area Wastewater Nan eNOIMLift Station No 1 Exhibit A London Area Wastewater Plan - Proposed `Flawer Fl w i Ime NMC*popMAlbn end west*weler Now psnerabn for the Ione useid�Mlbd 1 In ers woe are as followed- V — , rrsr�w • Litt Station 4 - r,rc.. a.+... w...... ��WMlen`rr res wrrr cm City Until "".. _ .�+ * N w iv' Proposed Mains - - b' - IA r • ---Force Main �l ' C — i ••---Gravity Main 2.P**bbp Feder Area The peek Now for sa lee hind uses.h. be psnts LS Service srse using the Bobber Formes vhIrJi Is corvine*Wed In ill kldbsty. The(annuls 1a es tallow COmmerdal Estate Residential PF•e i(poprd.Oor 11000)•0.2.(Mi elt'nn•2 Mestnrn.41 Low Density Residential a.rdelr.eorl end teem Medium Density Residential In ere inlet.,plink bNer*eon end hallow rota be dadetM using 400 pawn, per*Neer mew. Parks Public/Sens-Public LSI 4.P*.II Milan Flow Al deal.'a in.rattans.Sera 111111iMi end caseceon sweeps arses use the peak sow es Owls busk wrdi.rl.Include the Hardee lector and w.rson and Meow. SForee bleb. Fero mobs sheg be duignsd le have■velocity between 2 feel per second end sleet per woad be ensue that they r..a.quele to mon solid.. 15 in Gravity Main 15 In Gravity Main m a i R1:10,455:71 ..'._» k,a�!' .._ v111 ` ...---•.-..+ Miss > 0 0.050.1 40449.2 0.3 0.4 y ji' FLOW TO r OSO CREEK GREENWOOD MVP . , ' I • • 1 • : . j. NO Sii.'Vit4' ; }�� .. D1200( NO 7 MA IF1-{- I • '00 -.k 4LOUD PROVIOEO FOR i LL 1 I+ 1 • ftOODJPLAIN • -' srer,r,rwe 1 • 1 PROFTCISED 15"- IMO011...,•w. SE STATION •f I , •' 1=t WM.. P SERVICE BOUNDARY • . • I FORCE MAIN Wee (FROM LONDON AREA-\ • ^ •. I ` `• I • WW PIAN f 1 r • / ` i. ••Nr•w.1.0 IMAM. i i V , r 1, • \ \ • wM,Ire Y w/IW e.+Yf -- • •• Al ' ' UNE "J o • \•/ /5• I PROPOSED PROPERTv / O :• tun. STATION! ` ,�-�. - - • • , -N..........".. .../ CITY LIMITS r `a • • 1 D 5' • , L.- 5• 15' TS' _ •• •� ss ++ ++-- • j .._.__ ••NM•M•N•• ••'A ••NJY•N�A•N * r .r t• �T • •• J '• /1 LINE Hi l!: `i, 'r'AA7 ., ~, f O I• // '' • 1 ;,- '1`r XYet • . ,. .„,,,. ...„..... ,; x1 . /j ; • o / 1 f r .,,. .. , r r , co FUTURE i cv 0 ' SERVICE 4 z E r r--- 1 1 _ 7.:_'9 ,C !I WEBER ROAD (FM43) MIRO m DSI [.JSIGN ■►- I. _SX 11$ DC/STING GREENWOOD P s 741'004 N WASTEWATER TREATMENT PLANT / 41.p 0 751500 3000 e GRAPHIC SCALE / 1'.1500• LEGEND / -53 -ss PROPOSED SANITARY SEVER e FUTURE SANITARY SEVIER / ni rL ...•••. PROPOSED FORCE PAIN16' PVC FORCE MAIN —— PROPERTY LINE TO EXISTING MANHOLE OSO CREEX r."--'r i / \ /� / �6 to I tt 117 1 BROWNt /0 UFT STATION I `% I TRACT I • 24' GRAVITY UNE A' < I t '-- -- -- 1 I r � /1 J 1 � � t o 1 let {2I' GRANTY UNE Ill t t 18' GRAVITY UNE 'A'I M C.R. 43 (WEBER ROAD) EXHIBIT C 0 + EXHIBIT OF PROPOSED N LONDON AREA MASTER PLAN cr ( LI ENURBAN WASTEWATER GINEERING INFRASTRUCTURE o hole: This exhbit was revised per city request on March 27, 2018 to reflect a change in size of gravity sanitary sewer WS mu 1( 1 .CCRI lint qD 1TO 734p lines. The sizes shown on this revised exhibit are congruent S im sa�amrn CR tartars*en. tx 7ew� gru o NONE x.est.rn wvrt.u�urEM4cnt with the sizes shown on the city's revised London master 3 sanitary sewer plan which was presented to planning ga Jos ru 429o1$7Ao commission on 3/21/2018. A Eng P.iichae C Y:uv. P E OPINION OF PROBABLE COS i March 26 2018 (or Job No 42900 B7 00 LONDON AREA MASTER PLAN URBAN ENGINEERING REIMBURSABLE TBPE Firm No 145 SANITARY SEWER IMPROVEMENTS ITEM DESCRIPTION QUAN. QUAN. UNIT UNIT TOTAL +5% PRICE COST NEW LIFT STATION 1 Mobilization Bonds Insurance 1 1 LS $18 000 00 $18 000 00 2 Lift Station No 1 1 1 LS $425 000 00 $425 000 00 3 Lift Station No 1 Access Road 2 924 3 070 SY $50 00 5153,500 00 NEC Cost Estimate To Provide 480 v/3 Ph 4 Overhead Power LS Site 1 1 L5 5100 000.00 $100,000 00 5 Emergency Generator w/Foundat on 1 1 L5 $110 000.00 5110,000 00 LIFT STATION CONSTRUCTION SUE TOTAL: $808,500.00 Contingencies G 15% $120,975.00 UFT STATION CONSTRUCTION TOTAL: $927,475.00 EASEMENT COSTS: TBD ENGINEERING,SURVEYING,STAKING,&TESTING®12%: $112,000.00 SWPPP ITEMS: $7,500.00 UFT STATION GRAND TOTAL: 51,048.975.00 NEW 16"FORCE MAIN TO GREENWOOD WWTP 1 Mobilization Bonds Insurance 1 1 LS $38 000 00 538,000 00 2 16"C900 PVC Force Main(Green Pipe) 8 896 9 341 LF $75 00 $700,575 00 3 16'D 190 Degree Bends(MJ) 3 3 EA $2.150 00 56,450 00 4 16'D 145 Degree Bends(MJ) 5 5 EA 52 150 00 510,750 00 5 16"DI 22 1/2 Degree Bends(MJ) 3 3 EA 52,150 00 56.450 00 6 16'DI 11 1/4 Degree Bends (MJ) 3 3 EA $2,150 00 $6,450 00 7 16'Plug Valve end Valve Box(MJ) 5 5 EA $7,800.00 539,000 00 8 Air/Vacuum Valve Installations 3 3 EA 512,250.00 $36,750 00 9 Welt Pointing-Force Main 2,000 2,100 LF $50 00 $105,000 00 10 Asphalt Pavement Repair(Existing) 120 126 SY 550 00 56,300 00 11 Concrete Pavement Repair(Exist Driveways) 300 315 SF $10 DO $3,150 00 12 Directional Bore Oso Creek-16"Fusible PVC 1,384 1 453 LF $400 00 $581,200 00 13 Construct Horizontal Directional Drill Pads 2 2 EA $30,000 0D 560 000 00 14 Tie to Wastewater Treatment Plant 1 1 L5 $25 000 00 $25 000 00 15 Traffic Control 1 1 LS $7 500 00 $7,500 00 16 Marker Signs 20 20 EA $150 00 53 000 00 17 OSHA Trench Protection-Force Main 8,896 9,341 LF 51 50 $14,011 50 FORCE MAIN CONSTRUCTION SUB-TOTAL: 11,649,586.50 Contingencies Go 15% 9247,437.98 FORCE MAIN CONSTRUCTION TOTAL: $1,897,024.48 EASEMENT COSTS: TBC) ENGINEERING,SURVEYING,STAKING,&TESTING a 12%: $230,000.00 SWPPP ITEMS: $20,000.00 FORCE MAIN GRAND TOTAL: 52,147,024.48 c 1 . T61r Ir*? i\ ;*% •*1 % MICHAEL. � . K f$9:...; . .. ..Y0RK 3 J2`I/8 • IC..' ,+I4SioNAIE`G...... S iProiects142000up442900187001Contract AdministraboniEshmatap\Finat Coat Ea:imate_15 to Brown around Agape 21 stub to Sports_24 I 1 f Eng Michael C York P E OPINION OF PROBABLE COST March 26 2018 for Job No 42900 B7 00 LONDON AREA MASTER PLAN URBAN ENGINEERING REIMBURSABLE TBPE Firm No 145 SANITARY SEWER IMPROVEMENTS ITEM DESCRIPTION QUAN. QUAN. UNIT UNIT TOTAL +5% PRICE COST LINE'A'Gravity Sewer West of Lift Station to CR 33): 1 Mobilization Bonds,insurance 1 1 LS $16 00000 516,000 00 2 24"PVC SDR 21 28'-30'Cut 36 38 LF 5460 00 $17,480 00 3 18-PVC SDR 21 28'-30'Cut 1,351 1,419 LF 5385 00 5546,315 00 4 Embedment 1,387 1,456 LF 57 50 $10.920 00 5 OSHA Trench Protection 1,387 1,456 LF $8 50 512,376 00 6 Well Pointing 1,387 1,456 LF $50.00 572,80000 7 5'Diameter Manhole(28-30'Deep) 5 5 EA 514 75000 573,750 00 LINEA'CONSTRUCTION SUB-TOTAL: 5749,641.00 Contingencies a 15% $112,446.15 LINEA'CONSTRUCTION TOTAL: 5882,087.15 EASEMENT COSTS: TBD ENGINEERING,SURVEYING,STAKING,&TESTING a 12%: $105,000.00 SWPPP ITEMS: $10,500.00 LINE'A'GRAND TOTAL: $977,557.15 LINE'B'Gravity Sewer(stub out to East of Lift Station) 1 Mobilization Bonds,Insurance 1 1 LS $10 000 00 510,000 00 2 21"PVC SDR 21(28'-30'Cut) 120 126 LF $41500 $52,290 00 3 Embedment 120 126 LF 57 50 $94500 4 OSHA Trench Protection 120 126 LF 55 50 51,071 00 5 Wen Pointing 120 126 LF $50 00 $6,30000 LINE'B'CONSTRUCTION SUB-TOTAL: 570,808.00 Contingencies is 15% $10,590.90 LINE'B'CONSTRUCTION TOTAL: $81,196.90 EASEMENT COSTS: TBD ENGINEERING,SURVEYING,STAKING,&TESTING r@ 12%: 510,000.00 SWPPP ITEMS: $3,500.00 LINE'B'GRAND TOTAL: 594,698.90 PROJECT COST SUMMARY t New Lift Station $1,046,975.00 2 New Force Main to Greenwood WWTP $2,147,024.45 3 LINE'A'Gravity SewerjWest of Lift Station to CR 3 $977,587.15 4 LINE'S'Gravity Sewer(stub out to East of Lift Station) $94,895.90 ESTIMATE OF TOTAL PROBABLE PROJECT COST $4,266,283.53 Note 1 This cost estimate was revised per cty request on March 26 2018 to reflect a change in size of gravity sanitary sewer lines The sizes shown on this revised estimate are congruent with the sizes shown on the city's revised London master sanitary sewer pian which was presented to planning commision on 3121/2018 i* 1- \*,P *: '.*I ordi MICHAEL C.YORK 0 )4 124938 : / (4 .1) • c.. fCENSO... S tPrc4erz&,42000upiA2900te7 C.-Mt-act Administratk Zsturi'rgtFota•Cost Eshroate It to&13...n oround Agape 21 stub to Sports 24 to LS 2 of 2 . - .........-. ....„ ..... .....,.... ... _.. 7:= i F1017717i7 . Ir la til'... krid m5'461'1,15 ist t S i ', , 1 , I ro 4 ,,, \: \ I , fr • , ' , AIWA/ \ \ UVAIld 3 • 1 .....0'.... 1 f . ,..- • '',, ..............' I i • \ i / AtiOMW , I 6 $ ,, wow , , •llt = I I III )1. I . . I it ... -- ... • . mem/ ,14113,0111 I 7 WARY ... 7 UD I i F E -........-.. ,...._ I . , WilltKait. 1 1 0111 Miftlilerelne lirili of .--1 ". :: ' c••••------.:\2"... r ,.....,,,J ..., 1 um AI pilmo t wm....•••......••••••• 1111 twin 11•00J., . ..., A a I I 0 110 ON JP I I 44 1111111111k ap.......4, ...,•III PM 1111111111 swo INN Ur A 1 I i 1 /(4112:151/ 1 i I- ;II 40 I . . . . • . • I ' . b..........111.0M110.....................r..../.4...*,...um.......6........0,I419.•1 4 III A 06 1 - IP I \ i 5 '......., , 1 \ i . ik 1, ..........-....-.... .-.....,-.....-.y...... ..............-.-. ....---•••... .."-...+1. I. • 1 •••••••• I 111 I N. I 4- • t i . 1 • . ........'-. . 4 .• '.. ....te.: .... : ..: ' ... .....•...k..•..."'.. I . • ..• • s. I\ •• • I 'I I ‘,.\.c,,„1 l I 1 • • •••.•••••i•.1..••••' ------...,.......,lk, I _ • , I , .J ....-.........-3,..j. s•,‘, ''.$‘: 1 1 1 { .e 1g , ...,...-- I --- \ :---... --. 9 ,- ...... \*.s. I i \ ----- I V g \ \ ."....,, \ 1 I •:. . i .., it 13 E 1 t t \ z I .. 1 \ ..c•; :1 I 6Ell i--.41,......-....-../......- ....../................n. • . WI4 ? ..If . 4 1 , i E I . I , t•••• i‘,' i 1 . . . . . • • . • ., . . . II . . . .- • " i • .- , .--. • ! - i-.. ' • •• ' 'If./Of•ii . Vail f-•./-- -_,,C?"- • — .•. Nig? ..... _ , I .--- - .., .. . ..'..k^-i'l • • .•'-'•".•:- .: . is I. ' , : •• • ... • ,,.1 1 .., .., . ,. . i s I 111I 1 -.:: .. I - #1 .. . \' 1 // ...1 •••••••• ..• .• • ' 1 51141 i 1 •.. . 4 11 I ....--- . „, \ •. 7,. j 1 li 1\ II \ far t ircil i -.• \ ..I i mr.1 SUR 111, et1POr all" 1411 I.„,.. i 1 okb,iimi'm il 5 UPI STATION UTE OILENSION • PLAN MitriliPMMIllesinselligin"" IMMO 4-. tr.*arecion, MOO NIP ......-a,LIN • r,"14 •. ,,, I ' , , ,.• - - . 'S .6... • • ' s iraillia. NAW• t ' �uf L..f• i .ns...., a j • ��_--�._� I I! • s� 117Pf 1 I "I Y••. 1 .00.0f. l.fM ,f6Q _j77.1171_, iiii - -• _� ;r - ALT4__� j r. ; d \j' j11 /\ I I i .1 so....tt.j..,.ot _.‘,1_, 1 ,TTt" r ,yt Aar eon pal maws 1 a AC1 W.L,. 1CP ":A.A5 'Aka. „o4nGURAPO& O8 ..1.....,...................••••OWL GAS••••u•c••r PLAN HEW Al GRAOE ELEVATION-DUPLEX r..l 1..•-ID.ma.m.l:y 11•.•.•/0/1•1 Iw. .••.r•11r1.•O• ,101 1J YAI V !� •,..•••• ,o..n vsYa or 1 ill WCri 3t ev.a.nf.o.....1«....Or. .r.w ti 1r•� w.RT Q i y'•.r.w�-a .M rLa wuow.r.wrJ M� ..---.,•3•Z•-h---, C.•s�a.i� ,..OP.110 wY w. 11 _� 1•i__-a:7m_s.. - 1'- i L j . i•• -•. O'..• ^. •gay . ..a..e .•m......Ofv.yr --I I I %� a MI..Y...o r1O..O Wg0r O9r ! { has :w.� SI� 11 �.., `1_ ��. r .•...•.� ..M.••O�Y.�fMA�Y M•f rw 1 1 Imi . ..r.u..•.r..r..w•••n.••...a•S- 7•” lac.— N .�+' ,• rft;.r . .•o,.w w..F..alw r••f,a r w•s•.n•.-•r �'• I .... Z •• •^•..•w.=: ggeS ' ..mo 1•,4..w MOWN...Y.":,•r�i MONO/ -- .......0.......r.==. = �` �'� ;MAT. •..'�• l a••:r�e.r�.s�,r m..s■ /•'• , I'.' • Z 0� 1 f lik�� C arc .d.o.rw,...1..-....•..s w.,.r-...• r--;;;,--7.---1).--y / ,...•_t- .. W MIN I- Ors M..iwfo sr,.-rw-.s.w.Y.ww w. •_���= •_ 1� ( • iY_` r Y 'l, ep IIIIIII 1 1 �IIW..I n,f.Y 1WO Y.A,.•.••0,O•••••••••0•,r. •Mil1_ M•fK 1w•r OM-•••••••.fl* ..1 M—W.s.wY Oa 1110/1•01 1~11W2 •• r r ••••oi..i►•••1LI.1••Ye. Is•....w.•s.e-...a 3�''F`}KS-:!'::�'.%%•;.:}'6'v'•"•< �. 20 Awl ••— 0••1.1..•r—•sa•.w.111 WV.1■w—o MI In•••C L— ._.`• .. n�i—._._ Q'AI 3a. Yig g r .'.. PH181T.0 i s.0 1 ! , - • S -•••••3••••••••21/1,J......"..T.•••••••••••••••••••1••••••••mow.woe oft.e•e.g.•re.*ee um...re pee a ege -.• ............. •1.4.... 1 ".......- $ 'Sm.,. '....••,.... • ..• ••e: ..*S'.• ......*'••••.,..._ I 6 i Ig. • f .,*.„ PI , o ft fil ,,...., .. =,..: • i ::-.14 - si••,:, 1 ' j •,•••!''‹ r. ' • :ierX isi • 4 I I • i , •••• ‘,.•,.. Asriuo-s!roze..— / I , • • / •t,,,,,l''''")::, ;.• ' i ri-.-"-A AM". 'N,'' V•'• , • .4,.. : • I;•• ) •,4,5 4..„ ,p.... i r i : 1 OA,-,,..; , 1 .,- • il.;', Vt.-.4:t i . ...,,,, '4 ili • I :41 ift4-,' og ; 3 N• ifii. !I. I i I I ,e 4:-.;,-,:. :i • ,s• i . I. ,... . . I 1 : A t • Ar. el .•.1.-..,,..›,,,„,•,, ),'••': t• I4, 1 •>'. .1;47 I;•4 • • : 2 • ,•-•,I . a •:!..ZA'.'•:';':.1, P. . • i I ', ,.'N4'.e.' i :"I•• ' 1I I ..,•'. •0 I ' ,... .. . • i tc,<..."Vx• ;IR':••te'•••. ' ' 1 • r•Vill 1 )% . :-.. ,..,. i ::.....cg 1 , , I "•::W. , i a I . I 1 • 1 'I bi ail ---,,„,... i c : ....am t:' I 1 41,444.44.4.4.4....44,44.-.044 Is,"alrigirP', • .• .. imam to imps: .......... IS 1...!. lionin minaivir LFT STA/10N ACCESS ROAD i_it 4 imam oar M..2e4Craigilt+3 4..4 1...;;,a . '. 10 hP . LOW NSA MINIM RIM ili .t ...-. I ... iltr2PALT tt•Mg argeLie Ta1411"a ille let IIIII, i r-- : APPENDIX Appendix 'A' — London Area Lift Station 16" Force Main Duty Analysis Flygt Appendix 'B' — Geotechnical Report—Rock Engineering and Testing Laboratory, Inc Appendix 'C' — Record of Power Outages for London ISD Area Appendix 'D' — Responses to City Comments (sent via email response) (r URBAN .t,, `�' ENGINEERING 1.i:xti No.42900 --laeefed 05 22 f: by yl-'__.___.__ London Area Lift Station PRINTED 28' Static Head 16" Force Main DATE: TIME. Revision Nota Demon> Winona Pipe Din ansianah Seglraling Location•New L8 station approximately 504(7 to we north of the CR 33 and FM 43 intersection Pipe Diari, Pipe Diem Area Wetted !+h the east side of CR 33 Orches) (feel) ff1•121 Palm 8 0 67 0 3491 2 0944 Ending Location•pscharga ado eidsong manhole on 18 1 33 !3983 4 1868 sauowest corner of Saratoga and Greenwood Elevation Ode Location Elevation Top of discharge pipe at IR station 34 DO Marl water surface in LS wet well 600 Demme = 28 00 6 Static Heed • 28 00 6 Equivalent Lengths 8•PIpe Equ valent Equivalent 16•Pipe Equiv Equry Description Quantity Length ILFI Length(LF) Oeoaiplon Quantity Length(LE) Length(LF) B'90 Degree Bend 2 0 21 • 42 ler 45 Degree Send 20 0 20 • 400 645 Degree Bend 2 0 1D . 20 16'Plug Valve 2 CD 46 = 92 r Tee(Brae, i Flow) I Qi 45 45 18'Discharge 1 a 80 • BO 0•Tee(L.Ine Flow) 1 a, 15 • 15 8•Plug Valve I to 23 • 23 6 Check Valve 1 C 54 • 54 8'4l6'Increaser 1 eg 14 a 14 Equivafant length for fittings valves etc o 213 IF Equivalent length for 8ttngs valves etc • 572 IF Length of r Pipe c 46 IF Length of 16•Pipe • 8900 LF Total Equivalent Length of 8•Pipe a 259 IF Total Equiveleil Length of 16•Pipe • 9472 IF ale ieted system Curve IlL • Q 316•A c tt1 •1653( rLI�1•o 631 ,,,.•Mead Loss(qi 13•Flow(cfs A•Area(sr) C-Coefficient ai Fncticn P•Wetted Perimeter(11) L•Enu,aienl Length of Pipe(R) Ec Length Eq .engin 259 9472 8'PVC Pipe 13"PVC Pipe Fiaw Flow Flow C•140 C•140 Static (galydayl GPM (ds) Headless(N fieadtoss(f4 Head(it) 11344 pt) Pressure(psi 72000 50 0 11 0 02 0 02 28 00 28 04 12 2 14.4000 100 022 006 0 07 2910 2B t3 12 2 280000 200 0 45 0 21 0 26 28 00 29 48 12 3 432000 300 0 57 0 45 058 22 00 29 01 12 d 576000 400 0 89 0 76 0 95 28 00 29 71 12 0 720000 500 1 11 1 15 144 28 00 30 59 13 3 664000 800 1 34 1 61 2 02 28 00 31 63 13 7 00 1 5 1.39 1.74 2.11 23.00 31 92 13.1 1P1ies•1 Des algn Flow j 1008000 700 1 54 2 14 2 89 28 00 32 83 14 2 1152000 800 1 78 2 74 3 44 28 00 34•5 14 8 (29•5000 900 2 til 3 41 4 28 28 00 35 69 15 5 14.40000 1000 223 a 14 5 20 26 00 3?34 10 2 1584000 1100 2 45 494 6 20 28 00 39 14 17 0 1728000 1200 2 67 5 61 7,28 28 00 41 09 17 8 1600000 1350 2.79 625 7.95 26.00 4.211 $13 [Phase 2 Design Flow 1872000 1300 290 6 73 844 28 00 43 16 18 7 2016000 1400 3 12 7 72 9 69 28 00 45 41 19 7 2180000 1500 334 8 77 11 W 28 00 47 74 20 7 2304000 15X) 358 988 12 43 28 00 50 25 21 8 2448000 1700 379 1106 13 87 2910 52 93 22 9 259200C 1803 4 01 1229 15 42 28 OC 55 71 24 1 2736000 1900 4 23 1356 1704 28 00 58 62 23 4 2880000 2000 446 (494 18 74 28 OC 51 67 26 7 3240000 2250 5 01 18 57 23 30 28 30 E9 87 30 3 3800000 2500 557 22 57 28 31 28 00 78 88 34 2 3960003 2750 8 13 29 92 33 77 29 00 88 09 38 4 4320000 3000 6 88 31 62 39 07 28 00 99 25 43 0 4680003 3250 7 24 36 07 45 CO 28 00 11057 48 0 5040000 3500 7 90 4208 52 76 28 00 122 82 53 2 LRLI.'.c`..,G 1cr Cny..-.• 70C...+:10a37,4.%,..y,`,rJ...y.i.^scone,D..0",11,—o•rcuve.:"Lv'•. .,..,.0 .«.iw•_ ..... .• APPENDIX 'A' leant xy NP3153LT3- 416 r----- ,,,.... Duty Analysts Head kyrjhaad • 47 SYSTEM 45 CURVE 44 43 42 4, ,s 37 36 34 PUMP 32 to CURVE 3, 30 27 26 25 244 23 • 72 _ 21 [21.2 t i 699 GPM @ 18 17 32.6' TDH 16 15 14 13 12 1, 10 6 . 7 • •16 187mm • 64 i 41 I PHASE 1 3 2 I SELECTED PUMP 1 1438 U8 .rtt 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 (US 9.aen1 Wed MO M111140 COMPifiw 6 Indlv!dual pump Tobi Pumps 7$yzing Spodfic Flow Head Viet power Plow Head Pima power Pump MM, eneritY NPPMre 1OMNem 14US gam 2124 107r0 1462USppm 2121 tail. 721% 1mWMAl$MG 2476 t bUS g trait lQ4rp =US spirt 3261 10410 Su% 217 WMMS UG 3'I Ht **et Ft •�t;ttl��i� i.. �� dtaid• :i{alt ttpsile _ Laudon LII APPENDIX 'A' xy tem NP 3153 LT 3— 413 1=� Duty Analysis VWHead km head 70 893 SYSTEM 84 CURVE 62 60- 58- 56- 54 52 50 48 48 44 42 PUMP CURVE 35 gf. C 34 798 32 30 r_-- - t24.sni 28 26 22 zz= 1230 GPM a@ 20i 41 .6' TDH 18.4 16 14: 12i 14 13 217rtm 8 fi3 PHASE 2 4 SELECTED PUMP 2 0 �f 793 lS y.P� __I 0 400 800 1200 1600 2000 2400 NS 9 Pm) Wear pt. Cow= G voaw ri Individual pump Total tanning spaaiille I$yaMm Flow Head shift pow plow Maid Shaft power Pimp at worn HP$Hro 'foram Mat/Spam tet tl]Ie 1793USe orr. 716I 1121p 75!S 1]6*AM75MG 7atit 1>�1tYp4m a.AS 1SIl t2CVlpoff. tree UIJIp lett tilwwliSMG 2.2t LGelid , ',Coaled aic L8 (;1 11 Pfin APPENDIX 'A' SUBSURFACE INVESTIGATION, LABORATORY TESTING PROGRAM,AND GEOTECHNICAL RECOMMENDATIONS FOR THE PROPOSED LONDON AREA WASTEWATER IMPROVEMENTS-UE JOB NO. 42900.B700 OSO CREEK-FROM GREENWOOD DRIVE TO CHAPMAN RANCH ROAD CORPUS CHRISTI,TEXAS RETL JOB NUMBER: 0117309 PREPARED FOR: URBAN ENGINEERING 2725 SWANTNER DRIVE CORPUS CHRISTI,TEXAS 78404 AUGUST 10, 2017' t` , PREPARED BY: ROCK ENGINEERING AND TESTING LABORATORY, INC. 6817 LEOPARD STREET CORPUS CHRISTI, TEXAS 78409 , PHONE: (361)883-4555; FAX: (361)883-4711 TEXAS PROFESSIONAL ENGINEERING FIRM NO. 2101 ,-el''''Thlit 44.411C-Illi . *... ._ ..* MARK C. R0t , \VOISTI% s Z A1 .�G"ro•y./C..., Brian J.Geiger, P.E. Mark C. Rock, P.E. Geotechnical Engineer Vice President of Operations Cell: 906 370 5196 Cell: 361 438 8755 t4.. 'APPENDIX'134 August 10,2017 PROPOSED LONDON AREA WASTEWATER IMPROVEMENTS Urban Engineering Oso Creek -From Greenwood Dr to Chapman Ranch Rd.; Corpus Christi, Texas Attn: Mr. Mark Maroney, P.E RETL Job No.:G117309 Soil Profile Table; Boring B-1 D Description LL PI C 4 y, -#200 Ka Kr, 0-22 Fat CLAY 60-69 39-45 1.900 0 120 86-98 0.49 2.04 22-31 Fat/Lean CLAY - - 1,100 0 120 77 0.49 2.04 31-50 FaULean CLAY - - 1,900 0 60 55-85 0.49 2.04 50-58 Silty SAND - --- 0 31 55 13 0.32 3.12 58-60 Fat CLAY --- - 1,500 0 60 -- 0.49 2.04 Soil Profile Table; Boring B-2 D Description LL PI C q y, -#200 K. KP 0-24 Fat CLAY 71-74 50-53 700 0 115 67-83 0.53 1.89 ,- 24-37 Fat/Lean CLAY -- --- 1,400 0 60 - 0.49 2.04 37-47 Fat/Lean CLAY - -- 800 0 55 62 0.53 1.89 47-60 Fat CLAY -- - 2,300 0 60 100 0.46 2.16 Soil Profile Table; Boring B-3 D Description LL PI C y, -#200 K. Kp t 0-28 Fat CLAY 60-61 39 1,600 0 120 83-88 0.49 2.04 28-34 Silty SAND - - 0 34 55 55 0.28 3.54 34-35 Lean CLAY -- -- 2,500 0 60 - 0.46 2.16 I Soil Profile Table; Boring B-4 D Description [_ . P1 C q y, I -#200 K. Kr, 0-16 Fat CLAY 51-70 34-51 1,500 0 120 83 0.49 2.04 16-25 Fat CLAY - -- 2,200 0 60 - 0.46 2 16 Soil Profile Table; Boring B-5 D Description LL PI C 0 y, -#200 K. Kp 0-12 Fat CLAY 55-67 37-48 2.300 0 120 86 0.46 2.16 12-25 Fat/Lean CLAY --- --- 3,000 0 60 64 0.46 2.16 5 of 10 APPENDIX 'B' August 10 2017 PROPOSED LONDON AREA WASTEWATER IMPROVEMENTS Urban Engineering Oso Creek—From Greenwood Dr to Chapman Ranch Rd.; Corpus Christi,Texas Attn Mr Mark Maroney P E RETL Job No. G117309 Soil Profile Table; Boring B-6 D Description LL PI C y. -#200 K, Kp • 0-20 Fat CLAY 57 59 39-40 3 100 0 120 88-92 0.46 2 16 Where D= Depth in feet below existing grade LL= Liquid limit(%) PI = Plasticity index C=Soil Cohesion, psf(undrained) =Angle of Internal Friction deg (undrained) = Effective soil unit weight pcf -#200=Percent passing the Minus#200 Sieve (%) Ka= Active Earth Pressure Coefficient Kp= Passive Earth Pressure Coefficient The trench protection should be designed to provide the most conservative design given the design parameters provided in the tables above. It should be noted that the values for the design of braced excavations provided in the tables above are based on the soil strengths and soil densities encountered in the field and generally accepted empirical formulas correlating undrained shear strengths to drained shear strengths and the corresponding angle of internal friction for clay soils. The active and passive earth pressure coefficients were calculated using the drained angle of internal friction as recommended in "FOUNDATION ANALYSIS AND DESIGN",written by Mr. Joseph Bowles where he states, "Drained soil parameters for stiff clays and 4-C soils in general may be appropriate for lateral pressures behind braced walls where the excavation is open for a considerable length of time." Groundwater Observations Groundwater (GW) observations and the depths the borings caved are provided in the following table: GROUNDWATER OBSERVATIONS BORING NO. DURING 24-HOUR DELAYED UPON COMPLETION DRILLING READING 6-1 31' Ory and Caved at 27 Dry and Caved at 27 8-2 24' GW at 8 and Caved at 12 GW at 3' and Caved at 15 B-3 30' GW at 16 and Caved at 24 GW at 8' and Caved at 10 8-4 Dry Dry and Open GW at 10' and Caved at 16 6-5 Dry Dry and Open GW at 12'and Caved at 13 8-6 Dry Dry and Caved at 16 Dry and Caved at 16 6 of 10 APPENDIX 'B' 4 E • GEOTECHNICAL ENGINEERIN :o� C +•gyp •CONSTRUCTION MATERIALS ENGINEERING&TESTING • SOILS• ASPHALT• CONCRETE BORING LOCATION PLAN El • • 1 / } l l A Google Earth August 10 2017 PROPOSED LONDON AREA WASTEWATER IMPROVEMENTS Urban Engineering Oso Creek—From Greenwood Dr to Chapman Ranch Rd.; Corpus Christi Texas Attn Mr Mark Maroney P E RETL Job No G117309 Rocx ENGINEERING &TESTING LABORATORY INc. www.rocktesting.corn 8817 LEOPARD STA Err•CORPUS ChiFisTn TExAS 784091703 10856 VANo it ST•Sx:+ANTONIO TEXAS 78216-3625 OFF1cE (381) 883-4555 •FAx•(361)883-4711 OFFICE (210)495-8000•Fay (210)495-8015 No.1 ROUND+nUE LANE • RouNo Rock TEXAS 78664 APPENDIX 'B' OFFICE (512)284.8022 • FAx (512)284-7764 LOG OF BORING B-1 SHEET 1 of 1 ♦ CLIENT: Urban Engineering 1'4Rock Engineering sand Testing Laboratory,Inc. PROJECT: London Area Wastewater Improvements ( i 8617 Leopard St. 441 0 C 4 Caws Christi,Tans 78409 LOCATION: Greenwood Dr.; Corpus Christi, TX Telepha1.: 361-853-4555 NUMBER: 3117309 Fax 361.863-4711 +;`'.' DATE(S)DRILLED: 6/2/17-6/2/17 FIELD DATA LABORATORY DATA DRILLING METHOD(S): ATTERSERG Hdae Srtn Agar GROUNDWATER INFORMATION: _ andrtl Ne r s attooia.r.d at a dap.(d 31.st dieing drama z� csDry rad CIwiM at V-Nei upon oontpMion ii o 7 W 24-Has Moyer!Reeding.:Dry and Caved ay 274set. ti i iE A c ' i= # _ i i ,. SURFACE ELEVATION: WA $ / i;i r 8 U. Pt. PI 8 a, DESCRIPTION OF STRATUM i // . >SS v 1 ► Na 6 15 FAT CLAY,moist,dark gray,firm. j . s.2 Ps 4.5+ 21 68 23 43 a6 Same as above,gray and brown,with calcareous nodules,very j 3 stiff.(CH) Li Ps 425 15 los 2.3 Same as above,brown. j10 : si-4 P=2.75 23 60 21 39 89 FAT CLAY,moist,brown,very stiff.(CH) ../ ., Ss Ps 2.5 26 Same as above,brown and greenish gray. // 5". Ps 3.25 28 69 24 45 9e 0.8 98 Same as above,greenish gray,firm,stckensided.(CH) // , //I. /// 20 " S7 Pa 325 2e 99 1.6 FAT CLAY,moist,greenish gray,stiff,slickensided. SH P=1.25 19 Same as above,brawn,firm. j • SPI S-9 P=1,75 15 77 SANDY LEAN CLAY,moist,brown,stiff. • 35• s.8 Ps 4,0 24 FAT CLAY,moist,brown and greenish gray,very stiff. /. ,. ss Same as above,stiff, 40 ,5.11 �A N=10 21 /, • jss .•�1 S•12 SH P■2.25 22 104 1.2 85 LEAN CLAY,moist.brown,stiff. 2 .:41 19 rt cs Same as above,sandy,very stiff. r C $ ,s 1;N= 18 23 13 SiL.TY SAND,mast,brown,medium. - // 60 y$SS S1 ► N=12 3o moist,brown and greenish gray,stiff. terminated at a depth of 60t 1 N-STANDARD PENETRATION TEST RESISTANCE REMARKS: P-POCKET PENETROMETER RESISTANCE „8a °depth end bre Nan delru aan °y Wan Caordnilas Q.Dong*weave g VP Qc-STATIC CONE PENETROMETER RESISTANCE a portioned RaganDinc+by RETL at at lDril �w 274rac 1APPENDIX'B'1 LOG OF BORING B-2 SHEET 1 of 1 CLIENT: Urban Engineering .. 1,P4Rock�n6 gineering and Tasting Laboratory,Inc. PROJECT: London Area Wastewater Improvements 6t117Christi,Taws 78409 LOCATION: Greenwood Dr.;Corpus Christi,TX f�' (4. Telephone: 361-663-4556 NUMBER: G117309 . ' Fax 361-883-4711 ,.4 '. _ DATE(S)DRILLED: 6119117-03/19/17 FIELD DATA LABORATORY DATA DRILLING METHOD(S): - ATT!RBER0 - Holm Slam Auger LSAIT GROUNDWATER INFORMATION: ext i GW _and C."md 12.aet t dram,&ring e t i g S F e Q 24 t a,r o+b.a w.dkgs.GIN*3 s and Cased at 154set. .E 1 to i t t 1 i 1 ig 14 g i i i al g 1,7 I g 4 2SURFACE ELEVATION: N/A \ / i d 4 x IL PL PI B m g DESCRIPTION OF STRATUM S-t r:1 N=5 22 FAT CLAY.moist,dark gray,firm. 1. // 5: &2 I•P=125 28 71 21 SO 96 1.4 83 Same as above,Stiff.(CH) S" ' S-3 I P=0.5 25 Same as above.gray,soft. j10 y I P=1.25 29 91 1.4 F6T LAY,moist,gray,stiff. : s,s I P=025 29 Same as above,very soft. jj ``i6 6ci 15 - " N=WOH 32 74 21 53 67 Same as above,sandy,very soft(CH) J .-1/ 20 : S g N=7 24 TAT CLAY,moist dark brown,firm. - $41,,,, --s M P=2.75 24 Same as above,very stiff. % 30 : 8-9 I P-2,0 22 SILTY LEAN CLAY,moist,brown,stiff. � 35 .�s-to -i sil •P=325 25 96 0.7 FAT CLAY,moist,brown,firm,slickensided. -- 1--- r 40 j Sett P=0.75 22 SILTY LEAN CLAY moist,brown,firm. „ : ss 1 N=9 29_ 62 Same es above,stiff,with sand layer from approximately 42-feet 5 45 :S-12 +- l to 44'14-feet. /. i e/ 50 S"13 IN P■4.25 31 100 FAT CLAY,moist, brown,very stiff. : 55 �S.ts M P=4.5+ 27 96 2.2 Same as above.greenish gray. °/ 60 -ss s N=12 23 Same as above,stiff. Boring was terminated at a depth of 60-feet ' 11N-STANDARD PENETRATION TEST RESISTANCE REMARKS: i - PENETROMETER RESISTANCE Sawing depth and Imam rare drl.rr4n.dM t.r Engineering.+ °s em gP POCKET „,o. at GPS ' Oc-STATIC CONE PENETROMETER RESISTANCE �ew Cardiogram t"PPENDIX'B' LOG OF BORING B-3 SHEET 1 of 1 _ �e CLIENT: Urban Engineering 'e3 Reck Engineering and Testing Laboratory,inc. PROJECT: London Area Wastewater Improvements ( 'r�0 C�;r� LOCATION: Greenwood Dr.; Corpus Christi,TX � Ctttpue�,Tt►nas 713409 Telephone: 361.5133'4535 NUMBER: G117309 ,‘ Fax 361.5634711 •-'.7'' DATAB)DRILLED: 6/19/17-6119/17 FIELD DATA LABORATORY DATA DRILLING METHOD(S): ATTERBERG Heim Sion Amour f OMITS M g GROUNDWATER INFORMATION: Grou td.er(OW)ewe wtaourrsd at e dean at 30-teat dig dam. W t g (W at Meet at �t tpm foll�ebdl iL c2"f�fired ewe aw,r pleat a,d Ced at 104st 1 I SURFACE ELEVATION: N/A s d LL PI o STRATUM g i � � PL DESCRIPTION OF • 8-/ 14=9 24 fag=moist,dark gray,stiff. 5 : S a P=1.25 2a Same as above. sH - 111 Ps 2.25 23 80 21 39 95 1.1 53 Same as above,brown,with sand,stiff.(CH) // I Ps 2.75 24 FAT CLAY,moist,brown,very stiff. ,/. 10 • s•4 /, I Pa 2.75 26 81 22 39 97 1.1 55 Same as above,stiff,slidcenslded.(CH) 15 y Sa I Ps 3.75 26 Same as above,very stiff. C*/� 20 7 ,Pa 1.75 30 FAT CLAY,moist,brown,stiff. y S \�., / // , S-acIN 3.5 27 94 1.4 Same as above,very stiff,spdcensided. 2.89 P t4=24 2 24 55 SILTY SAND,moist,brown,with clay layer,medium. M 30 : '' , :s x t 20 27 �, CLAY.mast,brown,very stiff. 35 Boring was temtineted at a depth of 35-feet. A 1 7.- i q� C I 6 ` N-STANDARD PENETRATION TEST RESISTANCE REMARKS: Owingn=Engineering.Oiling eperseene $ P-POCKET PENETROMETER RESISTANCE per mpth eet HEM et bailor went�le N 77'41 > of 8 ac-STATIC CONE PENETROMETER RESISTANCE Boring Lemtlon.Propend Lift stolon IArrENDIX'B'I LOG OF BORING B-4 SHEET 1 of .+ ' CLIENT: Urban Englneertng •r4 Rock Engineering and Testing Laboratory.hc. PROJECT: London Area Wastewater Improvements (.- ' 4;'R 0 C 1e 4 �aVa�rd Texas 78 LOCATION: Greenwood Dr.;Corpus Christi,TX Telephone: 3514834555 NUMBER; 0117309 Fax 361-x63-4711 DATE(S)DRILLED: 6/20/17-6/2x17 FIELD DATA LABORATORY DATA DRILLING METHOD(S): ' I ATTERBEflG Holm ataw Anon s— Lair GROUNDWATER INFORMATION: Graaalerar COW)wr not ennotraland during drew gc Dry La / i 221-Mo�,M Deleted� Ibadir Ow et Klee,and CIwed at 40-feet W al 1 1 i SURFACE ELEVATION N/A �! / : t!_ Pt. DESCRIPTION OF STRATUM s1 tin 4 23 70 19 51 83 FAT CLAY with SAND,moist.dark gray,soft(CK) SH P=1.75 29 Sartre as above,gray,stiff, 5 , 5.2 -1SH 1 P= 2 0 22 Same as above,brawn. 10 ,PSti a 1.75 *22 51 17 34 96 1.0 0/3 FAT CLAY witfiSAfD,moist,brow.stiff.(CH) 8-4 • g„0/ 8H Ps 2.75 26 96 1.5 Same as above,stiff. III SH •P=3.75 25 16 , S4 Same as above,very stiff, C' Z0 . SM 1 pa 2.75 30 FAT CLAY,moist,brown,very stiff. St SH 1 p`3.0 29 Same as above. 25 . E Boring was terminated at a depth of 25-feet. • A 5 S S i I c N-STANDARD PENETRATION TEST RESISTANCE REMARKS: more doh ofd louron wire deUredrnd by Ulm Engineering.tiling operations b' P-POCKET PENETROMETER RESISTANCE wen performed by HETI es ops Ceentineha N 27"ii 04 sr war x 1astr. 8 Qc-STATIC CONE PENETROMETER RESISTANCE &The woman-cower mead n aloeic0mir !APPENDIX'S' LOG OF BORING B-5 SHEET 1 of 1 * CLIENT: Urban Engineering fir go Rook Engineering end Testing Laborite'''.krc. PROJECT: London Area Wastewater Improvements 6817 Leopard St LOCATION: Greenwood Dr.; Corpus Christi,TX ♦� u i .4 coma ChM,Texts 78409 NNN■■■ Telephone: 3814534555 NUMBER: G117309 '�.. Far 381-883-4711 .''b' !ATM)DRILLED: 6/19/17-8/19/17 FIELD DATA LABORATORY DATA DRILLING METHOD(S): ATTEMERG Wow Stern Auger E LIMITS GROUNDWATER INFORMATION: Oiaundw.br(UM was not moourr«.d during ding. DDalryed Reedsss�at 124sst and Caged r 13.4..1. i iil E : o. SURFACE ELEVATION: WA 14 i t I z a.A a LL PL PI DESCRIPTION OF STRATUM 1 j :r1 $Na 8 21 FAT CLAY,moist.darts gray,firm. 0 S8.3142I P-4.5+ 1 s 67 19 48 104 8.4 88 Same its above,hard.(CH) s,3 'Pa 4.0 20 102 4.7 Sams as above,brown. i 10 : S-4SH I P=2.5 21 fAT CLAY,moist,brown,very stiff. i/ . 8-6 M Pr 3.25 123 55 18 37 84 Stine as above,with sand.(CH) � / " SH I Pa 3.75 21 Sante es above. ; ts 16 - S / e •7 Pa 4.5+ 23 FAT CLAY,moist,brown,very stiff. 7 20 j S y ,P=3.5 me VAN Y,,r�esat,brown, very stiff. ' Boring vras noted it a depth of 25-feet 5 a 1 I. i i 6 N-STANDARD PENETRATION TEST RESISTANCE REMARKS: ts' P-POCKET PENETROMETER RESISTANCE i*misBonn*ph id _son'sSCarirud4Oben $ mimed oY RErL et t Cam mutes N Tr 4r 52.0'W Sr 1210 8 Qc-STATIC CONE PENETROMETER RESISTANCE unse n.Prgme.d Gm*Slow POO** {APPENDIX'8' LOG OF BORING B-6 SHEET 1 of 1 i le. CLIENT: Urban Engineering s".IRock Engineering and resting Laboratory,Inc. PROJECT: London Area Wastewater Improvements 6817 Christi,T LOCATION: Greenwood Dr.;Corpus Chris,TX �L># o c a + Carpus pardTeras 78409 Talephona: 3614334555 NUMBER: G117309 7. Fat 361483-4711 `'4DATE(S)DRILLED: 620117•8/20/17 FIELD DATA LABORATORY DATA DRILLING METHOD(S): ATTERBERG ` Hoi011 Sierra Maar g LIMITS 'S 4 GROUNDWATER w.nonot ar need during Ming. c INFORMATION: i — ik 1 E 1 Hoo r Ddiyod�R Ory and Caved et tt,-keit. g ��� e C ° 9 I o. } SURFACE ELEVATION: N/A tl }L. 6 a U. PL Pt o 1..) ro a DESCRIPTION OF STRATUM - ss a N=12 20 FAT CLAY,moist,dark gray,stiff. 5 . : I P•4.5+ 15 Same as above,gray and brown,very stiff. 8H 9-3 I Ps 4.5+ 19 57 18 38 105 6.6 88 Same as above,hard.(CH) sH ry 10 : S4 I P=4.25 21 101 3.3 FAT C1JY,moist,gray and brown,very stiff. - SH I P=4.25 19 Same as above. j " SS SH 1 tis 4.25 22 59 19 40 92 Same as above.(CH) 7 15 - Se ( 5H r 8-7 $P=4.25 , 2e - FAT clan moist.gray and brown.very stiff. Boring was terminated-at a depth of 20-feet S J ii C i O ( N-STANDARD PENETRATION TEST RESISTANCE REMARKS: Boring depth are location ar tion we dear netted yr Urban Engineering.*ling �ng apeIa $ P-POCKET PENETROMETER RESISTANCE vere performed ey REMetOn Cordnalaa N m 41'52110'err Ir 20.1tr. g` QC-STATIC CONE PENETROMETER RESISTANCE agkr9 Lacmlion Proposed Qre y Sow Roane (APPENDIX'B' 00• Nueces Electric Cooperative Your Touchstone Enemy'Cooperative 4,.. November 21,2017 Ln?'(,•,_,.;,,,,:-.•-•.- q:_•11 2,.!_-?...P:L...:,• To Whom it may concern, .-...,.-tor•urn• .. , The data displayed below is a list of outages we have on record for London ISD, • • • which is in the vicinity of the proposed lift station. , Dorado,' OutaaaRedD lkoodltatorrootiou .7kno1ostorod OutsipedPhase,CodomorsAdodad 267 2013-05-27.0367 5/27/2013 3:11 PM 5/27/2013 73$PM ABC 32 172 2013-11-224163 11/22/2013 934 IAA 11/22/1013 12A6 PM ABC 68 216 2013-11-224163 11/23/293 136 PM 11/22/2013 4:32 PM ABC 68 145 2014-07-22-0532 7/22/2014 400 AM 7/12/r14625 AM jABC 71 104 2014-1041-0118 10/21/2014 1014 AM 10/2112014 11581AM ABC 1 470 2015-04-22-1013 4/22/2015 3.29 PM 4/22/2015 919 PM MC 121 124 1015-11-074047,11/7/2015 3226 PM ,11/7/2015 230 PM ABC 4,921 1493 201643-19-0415 3/19/2016 12:23 AM V/20/2016 156 AM _MC 15.3 ( 99 2016-05-09-0119 5/9/20161146 PM ,5/9/2016 2:25 PM A 3 141 201741-29-0165 1/23/2017 823 AM 1/28/2017 10-45 AM ABC 143 25 2017-01-31-0947 1/31/2017 1018 AM 1/31/2017 10:43 AM ABC 142 6 2017-02-20-0432 2/20/2017 461 AM 2/20/2017 457 AM ABC 153 - 1578 201748-254523 8/25/2017 4:16 PM 8/26/2017 634 PM ABC 1E3 Please note that the duration is measured in minutes. The two lengthy outages were due to major storms. Thank you. NuecesEt. ic A..f.. 41 Authorized Agent f Jason Ramirez Mill • .1,-,,,,,„ •..;..7- , IAPPENDIX 'C' Michael York From: Michael York Sent Monday,November 27,2017 3:58 PM To 'David Thornburg' Cc Gabriel Hinojosa;Annika Gunning;William J Green(BillG@cctexas.com);Larry J. Urban Subject RE:London area design Memorandum comments. Attachments Design Memorandum -London Wastewater Infrastructure__20171127.pdf;Capacity Calculation Exhibit_20171127.pdf David, Please find attached a revised design memorandum for your review and approval.Our responses to the city's comments are below in red.There is an additional attachment that accompanies one of the comment responses. Please let me know if you have any questions,or require additional information.FYI,Larry Urban will be hand delivering a hard copy of the revised design memorandum to Keith Selman this afternoon. Best Regards, Michael C. York, P.E. E` E NHG i From:David Thornburg[mailto:DavidTh@cctexas.com] Sent:Tuesday,November 14,2017 8:36 AM To:Michael York<MichaelY@urbaneng.com> Cc:Gabriel Hinojosa<GabrielH@cctexas.com>;Annika Gunning<AnnikaG@cctexas.com>;Bill Green cBillG@cctexas.com> Subject:London area design Memorandum comments. Michael the following are the comments on the information in the design memorandum that was submitted November 3rd. • Section II Flow calculations are based on approximately 4 homes per acre per the city's master plan the preliminary subdivision plan shows a density quite a bit higher than that closer to 6 units per acre. This subdivision will set the tone for the area development, is the design for 4 units per acre realistic? The preliminary layouts for the proposed subdivision result in a density that is close to that assumed on the master plan.The proposed subdivision will be located on a tract of approximately 120 acres.The master plan projected that the service area would include approximately 750 acres of residential development.It is assumed that the average density for the overall 750 acres of residential development will be in line with the assumptions on the master plan.Therefore,the design is based on the criteria set forth in the master plan. • Section II emergency storage is based on the outages in the area for the last 60 months not necessarily at the lift station. Please provide the outage history for APPENDIX 'D' that area for the last 60 months you may use the London school complex. Identify how much of this was from the hurricane. Outage history has been provided by Nueces Electric Cooperative(NEC)for the London ISD area.Based on the information provided,it was determined that adequate storage could not be provided.Therefore,the design has been revised to show a back-up generator for phase 1. • Storage capacity, The majority of the storage volume shown on page 7/10 48,762 gal. is in the line to the east serving the sports complex. As this is not scheduled to be constructed it is not realistic to use it for the majority of the storage unless there are plans to construct this line in the near future. Update the storage capacity calculations based on what is currently proposed for construction. See response to above comment.Storage capacity is no longer relevant as design now includes a back-up generator to be installed with phase 1. • The master plan calls for a 15" gravity line please provide capacity calculations to justify the increase to 18". Increasing this to 18" will require a master plan amendment. In order to facilitate the masterplan amendment the utility department needs to agree and approve the capacity calculations for the upsizing of the line. Based on criteria set forth in the master plan,the peak design flow for the service area to the lift station will be 3,044 GPM.The lift station is located approximately in the center of the service area.Assuming the two proposed gravity collection lines will split the flow evenly,each line will carry 1,522 GPM.The capacity for a 15- inch gravity collection line laid at minimum allowable slopes is 1,160 GPM.This is less than the anticipated peak flow.The capacity for an 18-Inch gravity collection line laid at minimum allowable slopes is 1,633 GPM. Therefore,ft is necessary to use an 18-inch line in lieu of a 15-inch.(see attached capacity calculation exhibit) • How will AEP be serving the lift station? Will there be easement requirements and will there be costs associated with the extension of service to the site? The lift station will be served by Nueces Electric Cooperative(NEC),not AEP.Our team coordinated with NEC regarding electric service to the proposed lift station.Electric service will be routed from Weber,North along County Road 33,and then East within the proposed Access and Utility Easement from County Road 33 to the lift station site. Michael these are the comments that we have received from the Utility department and an internal review. Please address these comments so I can respond to Utilities. DT David Thornburg Project Manager Development Services 2406 Leopard Street Corpus Christi,Tens 78408 Email,ilzoddtkIcctexas com Phone:(361)826-8451 2 (APPENDIX'D' r London Area Lift Station No. 1 Capacity Calculations Exhibit Total Peak Design Flow Per Master Plan Criteria: 3,044 GPM MANNING'S EQUATION FOR GRAVITY UNE CAPACITY: / Q = KR2'3S1'2A / n f Where: K=1.486{constant) R=A/WP{Area/Wetted Perimeter) WP=2nr CAPACITY OF 1S-INCH PVC(SDR-21) CAPACITY OF 18-INCH PVC(SDR-21) DIA(in.): 15.00 DIA(in.): 18.00 AREA(S.F.): 1.23 AREA(S.F.): 1.77 SLOPE(%): 0.16 SLOPE(%): 0.12 MANNING'n': 0.013 MANNING'n': 0.013 DESIGN CAPACITY(cis): 258 DESIGN CAPACITY(cfs): 3.64 REQUIRED CAPACITY(gpm): 1522 REQUIRED CAPACITY(gpm): 1522 "IS-INCH UNE NOT SUFFICIENT** "18-INCH UNE SUFFICIENT" Notes: 1. Criteria for values used in the above calculations was obtained from the Adopted London Area Wastewater Master Plan(see Exhibit'A'of this Memorandun),and from the Adopted Allison Service Area Wastewater Master plan(see remainder of Appendix'D'. 2. In accordance with common practice for this area,it is assumed the proposed gravity wastewater lines wilt be installed at the minimum allowable slopes. 3. Lift station is proposed approximately in center of service area.Therefore,it is assumed each of the two proposed gravity collection lines will carry approximately half of the total peak flow. .APPENDIX'D'� WastewaterCollecdon System Design 20 feet. Selection of locations for lift stations and force mains were dictated by topography while avoiding parallel gravity lines and force mains wherever possible. 3.3 Summary of Sanitary Sewer Collection System Design The sanitary sewers included in this master plan were designed on the basis of information contained in the proceeding paragraphs of this section. A brief description of this information and assumptions, which were used as a basis for the design,are outlined below: • I. Ground elevations were obtained from Lidar-produced topographic maps furnished by the City of Corpus Christi. 2. Area served by a sewer assumed to be fully developed. 3. Peak domestic flow= M x Average Domestic Flow where M =5/P'5;where P=population in thousands of contributing sub-basin. 4. Infiltration=400 gal/acre/day. 5. Design Flow=Peak Domestic Flow+Infiltration. 6. Upper end of small lateral to have a minimum depth of 5 feet. 7. Minimum size of pipe for trunk mains= 10 inches. 8. Minimum design velocity=2 ft/s. 9. Capatity:of pipes b od.on Metuungis•fortnuls 4-rAt6iiiTitV l0. Rouness Favor:n=0.0!3. 3.3.1 Pipe Size • Based on the minimum velocity of 2 ft/s,Tables 3-3 below was generated using Manning's formula. It illustrates the minimum and maximum slopes and pipe capacities for several sizes of pipe. APPENDIX 'D' City of Corpus Christi 3-5 fat Wastewater Collection System Master Plan- Allison Service Area Wastewater Collection System Design Min Max S%Mtn Q(ds) Q S%Max Qfied 8 0.4 0.764 0.494 8.4 2.263 10 0.29 1.179 0.762 6.23 3.533 12 0.22 1.671 1.080 4.88 5.085 ▪ 35 0i.16 2.583 1.869 3.82 7.941 38 0a12 3.638 2.351 2.83 11.417 21 0.1 5.009 3.237 2.3 15.526 • 24 0.08 6.396 4.134 1.93 20.305 27 0.06 7.583 4.901 1.62 25.488 30 0.055 9.616 8.215 1.43' 31.690 33 0.05 11.822 7.641 1.26 38.355 36 0.045 14.144 9.141 1.12 45.605 �-- 39 0.04 16.508 10.669 1.01 53.613 Table 3-3.Minimums and Maximum Pipe Slopes and($pac1es 3.3.2 Anticipated Wastewater Flows Based on the parameters and assumptions outlined in this section, anticipated wastewater flows were calculated for all sub-basins in the service area. Appendix A illustrates the Quantity of Wastewater Flow for each land use based on area and population. Using the charts in Appendix A, Appendix B was developed to illustrate the anticipated wastewater flows in each wastewater basin,and furthermore, in each sub-basin. 3.4 Lift Station Analysis Lift Station analysis was performed by anticipating all upstream wastewater contributions and comparing this result with the existing capacity for each station. Proposed lift stations in the system should be designed to handle the anticipated wastewater flows. There are thirteen existing lift stations and seven proposed lift stations in the Allison Service Area. Each lift station is tabulated in Appendix C. -APPENDIX'D' City of Copus Christi 3-6 Wastewater Collection System Master Plan- Allison Service Area ' . ........w.r -w.w...i.►_+WL..—..—.... ..w..... ..... _............ ._ ........w...._................. XL vr.......................... ......_... iw.a....s.rr.A.r'.y.::Y -',.y...... Exhibit 4 ÷ , MING CREEMOD N NIAS1EWA1ER 1REAIMENT PLANT o 7 r So WOO 0 GR NI CA / l.-t5 LEGEND ss m.o.. .....� PROPOSED SAIITARY SOB / •.' rte.. e �,._ .�... �.. FI111AlE SANTARY SErER / r...rL—n, .m.... PROPOSED FORCE WIN 18' PVC FORCE MAN d -- PROPERTY LIE TO EXISTING MANHOLE e 060 Mac r"---.... / t /\ / / Ic2 err / 1 ' -----7 N........._ , , Iii \ ieR�wi l /°P UFT STATION , TRACT z4'GRANT(UNE 'A' \ Z I « l ,� 21'GRANIY LINE 1B' / 7 I L__ / [ 1.- --1g 18' GRANIY LNE 'A' eip r C.R. 43 NKR ROAD) N EXHIBIT OF PROPOSED LONDON AREA MASTER PLAN 1118 WASTEWATER I Li - ENGINEERING INFRASTRUCTURE Note: Ws eshbit was revised per city request on Mach 27, rn = nyNO 2018 to reflect a change n siu o1 gravity sanitary sew o zm N°�Oi,CCaF15.al10. n a lines. The sizes shorn an this revised ashbit are coag i ent not ser .341 J'�'� with the sites shorn on the citys revised Landon master 3 sanitary sew plan which was presented to planninga a«aaeteo commission on 3/21/2018. ... ..... — __ _.._..._____ ._. ._.__.. __._....—..,...._..........— _ _ - . - -•- ....+.�..rY.r�i.ww.'►.a."uYi�W,..r� •..."..., +..... --.-..-..-w.....�...�...�....... -r.--a-, r..-.w.....w.•�-..-w ..... .. - .-•. N-. .-w.%.w-Ir�.liiai�..w+moi Exhibit 5 • Eng Michael C Yolk P E OPINION OF PROBABLE COST March 26,2018 for Job No 42900 8700 LONDON AREA MASTER PLAN URBAN ENGINEERING REIMBURSABLE TBPE Firm Na.145 SANITARY SEWER IMPROVEMENTS ITEM DESCRIPTION ' QUAN. QUAN. UNIT UNIT TOTAL +5% PRICE COST NEW LIFT STATION 1 Mobilization.Bonds Insurance 1 1 LS 518 00000 518,000 00 2 -Lift Station No 1 1 1 r LS 5425 000 00 $425,00000 3 L.if Station No 1 Access Road 2 924 3.070 SY $50 00 5153,500 00 'NEC Cost Estimate To Provide 480 vi3 Ph 4 Overhead Power LS Site 1 1 LS 5100.000 00 5100,000 00 5 'Emergency Generator eft Foundaton 1 i LS 5110000 00 S110,00000 LIFT STATION CONSTRUCTION SUBTOTAL: sa01,500.00 Contingencies 4 15% 5120,976.00 LIFT STATION CONSTRUCTION TOTAL: S927,47S.00 EASEMENT COSTS: TBD ENGINEERING,SURVEYING,STAKING,IS TESTING 0 12%: $112,000.00 SWPPP ITEMS: $7,500.00 LIFT STATION GRAND TOTAL: 51,048,975.00 NEW 18'FORCE MAIN TO GREENWOOD WWTP 1 Mobilization,Bonds Insurance 1 1 LS $38 000 00 $38,000 00 2 16"C900 PVC Ford Main(Green Pipe) 8 896 9 341 LF 57500 5700,575 00 3 16'DSI 90 Degree Bends(MJ) 3 3 EA S2,150 00 $6,450 00 4 116"D 145 Degree Bends(MJ) 5 5 EA S2.150 00 $10.750 00 5 16"D 1221/2 Degree Bends(MJ) 3 3 EA S2,150 00 $6,450 00 6 :16.13 111 114 Degree Bends (MJ) 3 3 EA 52,150 00 $6,450 00 7 16"Plug Valve and Valve Sox(MJ) 5 5 EA $7,80000 539.000 00 8 Arr/Vacuum Valve Installations 3 3 EA 512,25000 536,750 00 9 Wal Pointing-Force Main 2.000 2 100 IF 550 00 5105,000 00 10 Asphalt Pavement Repair(Existng) 120 126 SY 550 00 56,300 00 11. Concrete Pavement Repair(Exist.Driveways) 300 315 SF 51000 S3,150 00 12 Directional Bore Oso Creek-16"Fusible PVC 1,384 1 453 LF 5400 00 5581,200 00 13 Construct Honzontal Directional Drill Pads 2 2 EA 530 00000 $60.000 00 14. Tie to Wastewater Treatment Plant 1 1 LS $25 000 00 525,000 00 15 Traffic Control 1 1 LS 57.500 00 57,500 00 16 Marker Signs 20 20 EA 5150 00 53,000 00 17. OSHA Trench Protection•Farce Main 8,896 9,341 LF S1 50 $14.011 50 FORCE MAIN CONSTRUCTION SUB-TOTAL: $1,649,588.50 Contingencies 515% 5247,437.9E FORCE MAIN CONSTRUCTION TOTAL: 51,897,024.48 EASEMENT COSTS: TBD • ENGINEERING,SURVEYING,STAKING,&TESTING®12%: $230,000.00 SWPPP ITEMS; S20.000.60 FORCE MAIN GRAND TOTAL: $2,147,024.48 T4i1i/ i*`.- 1 .:"' to I ... .MICHAEL C.YORK . i1;.. 124938• ,Y„° i4'/s k,-%Wo S'orcects 42DODup429C043700/cntratt iornlnistratwn Ewmawg'Anat Cost Es!mate 15 to Drown wound lgaoe_2 t itab to Spats-24 to LS 1 or 2 - ., ............_...__....._....—.....___M_.,...,,.._. .,m–••--. �. ..i..,.._.. - • Exhibit 5 t ry fd ;t C Y ,' P E OPINION(31 PROU.Af3LF t.OS1 f.4;:c1 26,21Y6 10- Jzt.:fi,^. 229C( 13 Cf0 LONDON AREA MASTER PLAN URBAN ENGINEERING REIMBURSABLE TBPA F.:rr No 145 SANITARY SEWER IMPROVEMENTS ITEM DESCRIPTION QUAN. QUAN. UNIT UNIT TOTAL +5% PRICE COST LINE'A'Gravity Sewer(West of Lift Station to CR 33) 1 Mob.'za'on Bonds Insuran:e 1 LS 51$000 00 $'6 000 00 2 24 PVC SOP 21 (23'-30 Cut 35 35 LF 5460 0: 517 450 00 3 18 PVC SDR 21 (26'•3C Cut. 1 351 :419 LF $35500 5545 31500 4 Embed'-e-it 1 387 1 456 LF 57 50 $10 920 00 5 OSHA Trenoh Prote:t•on 1 387 1 456 LF 59 50 512 376 00 6 Wef)Pointing 1.337 1 456 LF $5000 572 830 00 7 5 Diameter Gtarmo'e 128-30 Deep 5 5 EA $14 75000 $73 750 00 LINEA'CONSTRUCTION SUBTOTAL: $749,641.00 Contingencies 6 15% $112,446.16 LINE'A'CONSTRUCTION TOTAL: 5862,097.16 EASEMENT COSTS: TBD ENGINEERING,SURVEYING,STAKING,&TESTING 612%: $105,000.00 SWPPP ITEMS: $10,500.00 LINE'A'GRAND TOTAL: $977,587.15 LINE'B'Gravity Sewer(stub out to East of Lift Station) 1 Mooi zatron Bonds Insurance 1 1 LS $10 000 00 510 000 00 2 21'PVC SDR 21 12W-30 Cut) 120 126 LF 5415 00 552 290 00 3 Embedment 120 126 LF 5750 5945 00 4 OSHA Trend'Protection 120 126 LF 59 50 51 071 00 5 Wel Point ng 123 126 LF $50 00 56 300 00 LINE'B'CONSTRUCTION SUB-TOTAL: 170,606.00 Contingencies 615% 510,590.90 LINE'B'CONSTRUCTION TOTAL: 581,196.90 EASEMENT COSTS: TBD ENGINEERING,SURVEYING.STAKING,&TESTING 612%r $10,000.00 SWPPP ITEMS: $3,500.00 LINE'8'GRAND TOTAL: 594.696.90 PROJECT COST SUMMARY New Lift Sato $1,046,975 00 2 New Force Ma n to Greea;ood V'N±TP 52,147,024.46 3 LINEA Gait/Sewer West of Lift Station to CR 33 5977,587.15 4 I INE B G'av•ty Sewer Imo a.t to East of Lift Stator $94,596.90 ESTIMATE OF TOTAL PROBABLE PROJECT COST 54,266.263.53 N-te 1 Th s cc a'es:•-'$'e was revised per city req.les',on Ma-c-26 2J'3:o rar.ect a change its ze of 3-a•/ti sa'.tary semi' „s The s es s,']1."or til a re!Set es:mate a'_:;1y",.e:-:wi",the s zee s"oi.r or C1e c:y s re used L loon masts:sanitary sewer clan wrn:cn was Lresertea to p!a-n ng commison on 3:2123'8 • i**: �\ irI MICHAEL C.YORK f, (0i40 I a9• 124938 :,tea.. ^.1 - - ,-a' J:. . 7 ...CPUC.. . :Z'111• F.._e. �....^.........- .-..-,rte.+... • tOO'slIttOOtOZ an n6sfICS as 'on '*spa gnu ci2 X3 �NQM,IlaTtiX3 ul WV Ps geoPdrxe3 Folittuam 8 L (I) d I pue tea Pas easy 4FApassaid as von tap warm ap as=ma Su &o asp at=Ars a ovasrtnis oo spy :ALNvaIYM QNY 3NIVAMANOO OL SNOLL ECM QNV fO11.3 SNOLLYAIEISEM • ��y /{ 't.Ci+ ;&sus=a 3gligi="RST WIN !V) ()Pi!*11"4.v,. r °, 144 Psi.44 no -111140A411111R (i) • Pus a a raj!veinal Pa—got* 4 0*90 IPS24110115* t� °.L 3a7 Psis*Pal, Pal °NvN mom= , pogposOp ss Amu• 2:03nk ui DM 9ZI'SI'a ft 7 o3oq d1 alms FP Palm=oq ex..usuca no pip ss sum%mop imam tq 32sz ails R9S'68 • . 41361 :Purl PacNaaaP 2011601101=U. :A IEb1 111 QTgsaltA=WPM pas u*{pa=i :NQU yUGISKao 891$L s*0.L'PM s=dE3 scat b.**cm SSECITQQY°MIMI samurai 40I)&w a d%softmg ss'.4.0.739ixbon row vssxZw (d 4,E/1)612141a3CIom Viso Wean SIAYlILIsvoven (Z) (liJ/I)4 JOId aoersdos Wi ss'MOM rine (i) =S3dLtivitO unerdatims•`NEOQtOTSv'tIENS ZTOiNIvED fIDZ'8Z=FPO :SPfaEAxr-1L.L3 aua M1 YWM MOli3 UO3 8A11.VeMe1S Ob 15-1201x.#AJ 6914 1,091.OZ#OO • • • . • . • . • • .••••••....4*.•-% • • • inetertilogits1 tearer fee!,ruhritlosknodlor opeSios tied tenitteelitel btolrfots foes.quit,or ItoOdiod*ono Icy* ,li-,.°1#014+I**any1°4:-..atTalkwmi 1.1114 ófths Laiki Ay C0 Mgt;1041***PKR.,,t,ft ' iRr9F,4111114 to than*(it kle ristresdeit • .;-.• bYtkv1Plat the Ina Mid PrOpirtirfor doliesik *On • mid Pmpatria) • the zerieby iiireip alerted k notivstielpatles end nosmasootko mid it+Art be nieemity 1hr tate theater Illsoseee Woe 1.9 join Ittffirsameendon of *el weer kir 141141.111013.11*-4.tit'PC*by 1W111. digitIä1fiWg"*111*. lba IyWid ArIN the atIiditOe theirha*tolat000,doir7s6r aidlois;lothiO-Ogiliidilit IP to The loom the sight tai Pool sr SOO=the Soreki4ith els la* and al") the otkaiitor 1691 aTitfigS*01!1411 Mit bac IRV fifikt of it**, r wen a the with rigid 93 tids • nipose. This royeity or aired u to tided tights ahall be only for the life of c• • and shall tri. • • an die dish ea** GRANT OF PROPERTY: • • ' Gamer, fir dm Considanden nod subject to the Reservithsos sad Exceptions to Coueersteemei Wattesitz: r, GRANTS, ULLA imd CONVEYS c• • Properry. together rhit in sod kagnlir die ifs*and eginsammicei*rote is aiy belongs&Worse sodtolsoldirosiGrerseer:id anialier irks,iee..Aa1fr sod • Omar MIAs Chow and G*14tei eteruMs, kdmisistreMis, end --•`•• in jurist mai *Mier Mead a mond dug*tbe Pripet*ID 033310969 asizgoze reptscutithiiiiani Nilo whin eve4 paste rbeesseeter Ixwfi&Uyekliiing or an dike .• septipr any pert • theteg and except as to the Reservation From and Exceptions an :• •- led Wirzeitty. Wheo the=mos requires,singular news mid pronouns Include the pima CORRECTION: Thin Cm:m*4 Vir_amtery Deed is nada in frac,*of and* • .. . • Of*et Wmtmity Deed died :0Moler2k201:4 foil 0 7sniMr: Gomm 20L4ou90 of the Official Recoils of Wucom crojit4 Teirei Obi woriginit *he purprise'ef this careedoi —vhsinew Deed is M -legikdestielpdan Of Tana I ad II le *di is ff"A'af Oâçd WqOd n tin staid 4:areredeei*Phi legal orieristess,` ,this omieedee ifs7osity tatitui . . iii raped tiecirkend Deed,Sod dm 'feted' ve'dap of this diereciki iiineity Deed iektes beck to the efferetiie date eftbe Orightel Deed. (Sigestere Pages Follow) 3 ties Mies, lila. 59 30121.6561 an 2015011169.003 SOW6IITTINTOE ax 19i6CICM ss -on '.aa MT& • S ,f3347 wf . ri jr) NMOgH i TIIH�4'Si�t !osp a o'agiaosmr=P4PQ P MI. • 4 s-�'•+ J� 301 TIdf O3 4"4"" ,t•; 4 J SYXILL AO ZEUS a rallitiVIED wane Vie; IBE 1041214) 33071 RAS =MID Pocablo•&nownwoo dm airqualks LOO ditrtettOZ PR I/96MM= it "DZ 'Intel *rasa zwirsrskimpi..pna.meggsgsvappwa • • • rAr• •MIS*Mod PIM 4 'zoom mows tortvssArrvia tux -Iv I-I • Ric jet oqi to aa: P2PolootEPI nia 00M135%IPEL -1 * 1.-7ies AINflOD bons ZN, MAMS teLn ELLVIS I • '• f NOON* •1; 01111111 •7• FA61329 WI fo .T1 %.111 j! t j 3,INVILD 4°93FUZ-4,1a.,142V11.411, meant ipzia,Tsang uawirr tan 3!apzista gown Rums 20Puo paaa&mum uogoorico mita=Waft, • 4.4s. ‘4.-• 7• • : • ••• ;' . .. SOVOTTIOSIOL OR MIMICS Za 'wax 'Qlia arm • -- ..iO ' 3DVa y 1181NX3 • suzItiwislmsa } LOK vri s1Ju'sopa 3 won • • 111104 t al:PH a4 Aul30 uug ag+ >'aum . . s:asliaq •-• --•Alan L'padaid ag1 Jo 4varts qq MP LIP=£op/mgt./2'3 mon'1 • 'apPdP3oP spout*pas=gm silt sasasdmo=32•P V{Z "masa son(E6 E>i Mx 031114 MIND Oa Pug am autugge I sai0N 'graI 01 3J0 'Pug 30 sum 9Zl'>iI t altuPur Pug' awls ql°D.n onua8 d0 Irma•'P as ulll 6171££30.-- • a'gaM.cC.OIAL'MOS'fXPen 3Jo V°U1113 Intik*Rq>iMSJMBBl • lamas Irma sswoa sssaguaa alp J4f Pte' *4 arse 6VOE I Pias aqua saa103 sw>gsnos •a9'££Psaii l JodtiMlotq>fu aip t9 p$P PC"raii.tut•en b J* gousull:eggli3 SP.6t.1114'°N'Pm asp0 6YY0£1 PIW 21PJ0 0011 "P' 1 q II t %M 33119I1 L -Lames s1F3a nmiaa sassquou aspxii pus 53st!am 5,161 ppm ala am sea aqi al'saral' ••. bald RPIQ0! Pgo'LLDWi 61'ott si'?*Pf o dl OOP=P?aP sal Pa9I2P se=la ws I dtez'S M apps#100a sgruPgrg gePAII rig Pal OM a/s s 4:003 9191P1E • • . la10=UP i M Jr.10.I0 TON haw alts Wm PtaA M3Il AITf+111109 tPift SJNSID. • s • 'PPP - .91,141 wr Wi' I n 11 PPO'Fo6oto600t•ax>wuuaaa • pulp!4 Pa9i ii!siiia.1014,6110ggairgYi 10 101011 . 1 spas aqua sun siquq irs#stap plit a t sissaa Iso4 oa asp�q As pas isaq.sx s of X! Ld"wn la - •• •S' 110:08*a�roc pPsP&swami woo*Ina=km • 6L'SSOLJa»iP s tguat.SS.OI.Ot ISn°81,1rF4004,111)WO Jo*Piro Airs UPallb 1oA►3a00p—. .1g l 5;3N 1TM_6%anAIMP!woelwagpgs agl Plu•10::(1.%Osig03 10r.giN P spioos • . 'PcPLLOcoez'°K !a s!PaP+a P$P sati qi p is aas Gimp JIulara Euaquaa • 't E an JJt t*M JO �M NP Val Pao dal X i 1e otata IO34 a PSP a0:01: gaol Sill 11 1Pw.L' s''!??atls .!>ldfW'St abet sa'a�gi, 50#1'A-010+I1,PaOti Pp C£I'0.4„i0211 111*D 1 POP 010 suPq asps asse ate•• 111 Plat 7a+1' 3 i piss]'L>t 1?Id'LS£I Mab1OA nl PaP'a MPs 01• -•a PA Jo sxa arts r0 I lie V*WAWA PMi1l6 s>Ea UM 9t{71 i Ila sari PPM • • S33311/1 gO 1t.LN1113D SV7t:9.L AO 3.LV.LS • r'a:y •• OiiprydearsCM k&TawDeptrmrmr a(Oae3arweat Sawa BatCity of P.O 'VAT Caws CMist Teat7eY9Ai77 _txusxna Stem a(MC ofLeepCdSi. Pan Avc 1 inChristi DISCLOSURE OF INTERESTS City of Corpus Christi Ordinance 17112.as amended.requires all persons or firms seeking to do business with the City to provide the following information. Every question must be answered. If the question Is not applicable. answer with'NA' NAME: aj2A s EZ. NI,�•i*JAI L�st �". 1z STREET: s. -5 7 Yotz(L�LAA CITY: C .5 Cl!I!S1 ZIP: 7$ t 3 FIRM Is. Corporation 0 Partnership 0 Sole Owner 0 Association ❑Other DISCLOSURE QUESTIONS If additional space is necessary,please use the reverse side of this page or attach separate sheet. 1. State the names of each "employee" of the City of Corpus Christi having an "ownership interest" constituting 3%or more of the ownership in the above named"firm". Name Job Title and City Department(if known) 2. State the names of each "official" of the City of Corpus Christi having an "ownership Interest" constituting 3%or more of the ownership in the above named"firm". Name Title 3. Stats the names of each "board member"of the City of Corpus Christi having an "ownership Interest" constituting 3%or more of the ownership In the above named"firm". Name Board.Commission.or Committee 4. State the names of each employee or officer of a"consultant"for the City of Corpus Christi who worked on any matter Mated to the subject of this contract and has an"ownership interest"constituting 3%or more of the ownership In the above named"firm". . Name Consultant CERTIFICATE I certify that all information pr•• •-• true a • .i"as of date of this statement,that I have not knowingly withheld disclosure of any in • . • requested -. . that su tal statements will be promptly submitted to the City of Corpus Christi,T= . j- ranges .. Certifying Person . _ � �I/!L' Cf 6/4/ The: exec vP (Print) ' Signature of Certifying Person: /.i,!�J _ — Date: 3//Iow i4' g.neELP ENTSVCs,r,R ••• racEAYDOM:aant • e Am lOAmXATt0NFOPPO*eAs etau. or_ascsOi,weortI.Rr>rs Page 1 of 2 cTATEMNT 27 MAX Exhibit 7 CITY OF CORPUS CHRISTI DEVELOPMENT SERVICES 2406 LEOPARD STREET CORPUS CHRISTI,TX 78408 Doc. 2018021586 $ Pases 65 05/17/2018 2:52P11 Official Records of NUECES COUNTY KARA SANDS COUNTY CLERK Fees $267.00 Any Provision herein which restricts the Sale► Rental or use of the described REAL PROPERTY because of Race► Color, Relision► Sex► Handicap► Familial Status• or National Orisin is invalid and unenforceable under FEDERAL LAW► 3/12/89. STATE OF TEXAS COUNTY OF NUECES I hereby certify that this instrument was FILED in file number sequence on the date and at the time stamped herein by me► and was duly RECORDED in the Official Public Records of Nueces County► Texas KARA SANDS ` x �'`{3