HomeMy WebLinkAboutC2019-368 - 5/17/2019 - NA TASK ORDER NO. 34
This Task Order pertains to a Master Services Agreement for Geotechnical and Construction Materials Testing
by and between City of Corpus Christi, Texas (City) and Rock Engineering &Testing Laboratory, Inc.,(Lab)
dated January 16, 2018 by Motion No. M2018-005 (Agreement). Lab shall perform services on the project
described below as provided in this Task Order and in the Agreement. This Task Order shall not be binding until
it has been properly signed by both parties. Upon execution, this Task Order shall supplement the Agreement
as it pertains to the project described below.
MSA PROJECT NUMBER/NAME: 17100A Geotechnical and Construction Materials Testing
TASK ORDER PROJECT NUMBER/NAME: 17100AI Geotechnical and Construction Materials Testing
1. PROJECT DESCRIPTION: E10144 ONSWTP On-Site Hypochlorite Generation
2. SCOPE OF SERVICES—GeoTech and/or Construction Material Services to observe, test and report for
the ONSWTP On-Site Hypochlorite Generation project, and as more fully described in Exhibit A.
3. COMPENSATION —The total amount not to exceed for this Task Order only is $10,900.00.
This Task Order is approved, and Lab may proceed. All other terms and conditions of the Agreement remain
in full force and effect.
CITY OF CORPU ISTI ROCK ENGINEERING&TESTING
(Tb 05-14-19
eff H. Edmonds, P.E. Date Curtis A. Roc Date
Director of Engineering Services Chief Op ratin Offic
6 opard Street
Corpus Christi, TX 78409
(361) 883-4555 Office
curtis@rocktesting.com
Project Number: E10144
Accounting Unit: 4098-041
Account: 550920
Activity: E10144-01-4098-EXP
Account Category: 50920
Fund Name: Water 2019 CIP
Amount: $10,900.00 •
Task Order No. 34
Testing Agreement
Page 1 of 2
SCANNED
TASK ORDER FUNDING REQUEST FORM
CONTRACT MSA#AND TITLE: 17100A Geotechnical and Construction Materials Testing(ROCK)
TASK ORDER PROJECT#/TITLE: 17100A1Geotechnical and Construction Materials Testing(ROCK)
REQUESTING DEPARTMENT:ENGINEERING DEPARTMENT
FUND NAME/FUND#-ME: ACCOUNT: ACTIVITY:
4098-041 550920 E10144-01-4098-EXP
CONSULTANT:Rock Engineering
TASK ORDER#:34
SCOPE OF WORK:SEE PROPOSAL
TASK ORDER IS FOR PROJECT(S)LISTED BELOW:
PROJECT# FEE _PROJECT NAME
E10144 $10,900.00 ONSWTP On-Site Hypochlorite Generation
$10,900.00 Grand Total
ALEX BARABANOV,P
PM PRINT N• b ..
fikr dir
SIGNATURE•
DATE:
Task Order No. 34
Testing Agreement
Page 2 of 2
PPG
0rFS • GEOTECHNICAL ENGINEERING
�G�a T/4,C • CONSTRUCTION MATERIALS
ENGINEERING&TESTING
�,p9 oPv • SOILS•ASPHALT•CONCRETE
4rp'4Y .�G0P
May 3,2019
City of Corpus Christi
Engineering Services Department
1201 Leopard Street, 3rd Floor
Corpus Christi, Texas 78401
Attention: Mr.Alex Barabanov,P.E.
SUBJECT: PROPOSAL TO PERFORM A SUBSURFACE INVESTIGATION, LABORATORY
TESTING PROGRAM AND PROVIDE FOUNDATION RECOMMENDATIONS
FOR THE PROPOSED
SODIUM HYPOCHLORITE GENERATION FACILITY
O.N. Stevens Water Treatment Plant
Corpus Christi,Texas
RETL Proposal Number: P042519A (Revision 1)
Dear Mr. Barabanov,
Rock Engineering and Testing Laboratory, Inc. (RETL) (TBPE Firm No. 2101) is pleased to submit the
following proposal to provide a subsurface investigation, laboratory testing program, and provide
foundation recommendations for the proposed Sodium Hypochlorite Generation Facility to be constructed
at the O.N. Stevens Water Treatment Plant in Corpus Christi,Texas.
Based on information provided to RETL,the project will include the construction of a Sodium Hypochlorite
Generation Facility. See below table for project details.
Facility Facility Name Facility Size Slab/Pier Load
Number
1 Brine Containment 63'Lx42'Wx10"Thick Slab 600 psf
2 On-Site Generation Feed Building 121.5'x57.4' 100 kips
3 Sodium Hypochlorite Bulk Containment 177'Lx92'Wx12"Thick Slab 600 psf
4 Sodium Hypochlorite pumps and 91'x34' 50 kips
Chlorine Dioxide Generator Building
5 Hydrochloric Acid Containment 42'Lx24'Wx8"Thick Slab 400 psf
6 Sodium Chlorite Containment 42'Lx24'Wx8"Thick Slab 400 psf
In addition to the proposed structures,new pavement and parking areas are planned as part of the proposed
project.
ROCK ENGINEERING& TESTING LABORATORY,INC.
Corpus Christi San Antonio Round Rock
Office:361.883.4555 Office:210.495.8000 Office:512.284.8022
Fax:361.883.4711 Fax:210.495.8015 Fax:512.284.7764
6817 Leopard St. 10856 Vandale 1 Roundville Ln.
Corpus Christi,TX 78409 San Antonio,TX 78216 Round Rock,TX 78664 Exhibit A
www.rocktesting.com Page 1 of 4
Page 2 of 4 PROPOSED SODIUM HYPOCHLORITE GENERATION FACILITY
May 3,2019 Corpus Christi,Texas
Attn:Mr.Alex Barabanov,P.E. RETL Proposal No.: P042519A(Revision 1)
Based on the clients request and RETL's experience with soils in the area of the project,RETL recommends
performing a total of five borings;two borings to a termination of 50-feet and three borings to a termination
depth of 30-feet within the footprint of the proposed facility. (Total number of Borings: 5; Total linear feet
of Drilling: 190 LF).
The scope of work is outlined below.
Scope of the Proposed Subsurface Investigation
• RETL shall stake the borings in the field prior to the field investigation.
• The client or representative of the client shall obtain the required access requirements, including right
of entry, and excavation permits, if applicable.
• The client shall perform due diligence to assure RETL that the boring locations are accessible and clear
of private utilities and obstructions, such as piping, fences, heavy brush, shrubs and trees. The borings
will be relocated if necessary.
• Coordination with the Texas 811 system will be performed by RETL to identify underground utilities
in the proximity of the boring locations. The borings will be relocated if necessary.
• An experienced soil technician will log the borings in the field full-time during the drilling operations.
• A truck mounted drilling rig will be utilized to access the boring locations.
• The borings will be sampled at 2.5-foot intervals to a depth of 15-feet, and at 5-foot intervals to the
termination depth of the borings.
• Disturbed soil samples will be obtained employing split-barrel sampling procedures in general
accordance with the procedures for "Penetration Test and Split-Barrel Sampling of Soils, (ASTM
D1586)."
• Relatively undisturbed soil samples will be obtained using thin-wall tube sampling procedures in
accordance with "Thin Walled Tube Sampling of Soils, (ASTM D1587)," if applicable.
• Shear strength of cohesive soils will be estimated using a hand penetrometer, if applicable.
• Standard penetration tests (SPT) will be recorded in granular soils.
• The borings will be advanced to the depth specified above.
• Groundwater readings will be obtained during drilling and immediately upon completion of the drilling
operations.
• After completion of drilling operations, the open boreholes will be backfilled with cuttings from the
drilling operations. RETL will spread any remaining cuttings from the borings across the surface at
the boring locations.
Scope of Laboratory Testing Program
• Supplementary Visual Classification (ASTM D2487)
• Water Content Tests (ASTM D2216)
• Atterberg Limits Tests (ASTM D4318)
• Unconfined Compression Tests (ASTM D2166)
• Percent passing No. 200 (ASTM D1140)
ROCK ENGINEERING& TESTING LABORATORY,INC.
Corpus Christi San Antonio Round Rock
Office:361.883.4555 Office:210.495.8000 Office:512.284.8022
Fax:361.883.4711 Fax:210.495.8015 Fax:512.284.7764
6817 Leopard St. 10856 Vandale 1 Roundville Ln. Exhibit A
Corpus Christi,TX 78409 San Antonio,TX 78216 Round Rock,TX 78664
Page 2 of 4
www.rocktesting.com
•
Page 3 of 4 PROPOSED SODIUM HYPOCHLORITE GENERATION FACILITY
May 3,2019 Corpus Christi,Texas
Attn:Mr.Alex Barabanov,P.E. RETL Proposal No.:P042519A(Revision 1)
The preceding test methods may be performed on selected samples, depending on the actual subsurface
conditions encountered. All phases of the laboratory testing program will be performed in general
accordance with applicable ASTM Specifications. All laboratory test results will be provided in the report.
Projected Schedule
After authorization, it is estimated that the drilling operations can begin within 5 to 10 business days and
the draft report will be submitted within three weeks of the completed fieldwork. Upon receipt of review
comments, RETL will provide a final report within 1-week. If adjustments to the proposed timeline are
required to meet the existing project schedule, please contact RETL so that we can accommodate your
needs.
Geotechnical Engineering Report
In addition to the field and laboratory testing, a geotechnical engineering report will be prepared that
includes a description of the field exploration and laboratory tests, boring logs, a discussion of the
engineering properties of the subsurface materials encountered, and shallow and deep foundation
recommendations.
Fee and Limitations
The total fee to perform the scope of work outlined above is $10,900.00.
The Total Project Fee includes the field investigation, laboratory testing, and report preparation. The
following items will be added to the final invoice as required:
1. Standby time: $275.00 per hour/per company
Services provided for any revisions after the submittal of the final report,approved by the client in a change
order, will be invoiced at a rate of$180.00 per hour. Please note that the total fee provided above will be
honored for 90 days after the date of this proposal. After 90 days, RETL should be contacted to reevaluate
the fees and revise the proposal as needed.
The total fee to perform the scope of work does not include site assistance in the event the boring locations
are inaccessible. Mechanical assistance required to access the boring locations will be assessed based on
the subcontractors' hourly fee plus mobilization fee.
Services provided by RETL under this Agreement will be performed in a manner consistent with the degree
of care and skill ordinarily exercised by members of the same profession currently practicing under similar
circumstances.
The Client shall provide for RETL's right to enter the property owned by the Client and/or others
and assure that the boring locations are clear of private underground utilities and accessible to
drilling equipment in order for RETL to fulfill the Scope of Services included hereunder.
ROCK ENGINEERING& TESTING LABORATORY,INC.
Corpus Christi San Antonio Round Rock
Office:361.883.4555 Office:210.495.8000 Office:512.284.8022
Fax:361.883.4711 Fax:210.495.8015 Fax:512.284.7764
6817 Leopard St. 10856 Vandale 1 Roundville Ln. Exhibit A
Corpus Christi,TX 78409 San Antonio,TX 78216 Round Rock,TX 78664 Page 3 of 4
www.rocktesting.com
.s • +.
Page 4 of 4 PROPOSED SODIUM HYPOCHLORITE GENERATION FACILITY
May 3,2019 Corpus Christi,Texas
Attn:Mr.Alex Barabanov,P.E. RETL Proposal No.:P042519A(Revision 1)
The Parties to this agreement agree that if any claim is made that RETL failed to comply with any term of
this agreement or that it failed to perform its work and/or duties under this agreement properly,the client,
upon proof that there was some failure to comply or some mistake in the performance of the work,shall not
be entitled to recover any sum greater than the amount paid by the client to RETL for the service performed
by RETL or$25,000.00 whichever is less.
In addition, and notwithstanding any other provisions of this Agreement, the Client agrees, to the fullest
extent permitted by law, to indemnify and hold harmless RETL, his or her officers, directors, employees,
agents and sub consultants from and against all damage, liability or cost, including reasonable attorneys'
fees and defense costs, arising out of or in any way connected with this project or the performance by any
of the above named parties of the services under this Agreement, excepting only those damages, liabilities
or costs attributable to the sole negligence or willful misconduct of RETL.
Either the Client or RETL may terminate this Agreement at any time with or without cause upon giving the
other party 10-calendar days prior written notice. The Client shall within 10 calendar days of termination
pay RETL for all services rendered and all costs incurred up to the date of termination, in accordance with
the compensation provisions of this contract.
Closing
If you are in agreement with our proposed scope of work, please authorize us to proceed by signing in the
space below and returning one copy to us.
Thank you for your consideration of our firm to assist you with this project. If you have any questions, or
comments,please call at(361) 883-4555.
Sincerely, ACCEPTED AND APPROVED
By
Print
.R. Eichelberger, III, P.E.
Senior Project Engineer Date
For payment of services, invoice to:
Firm: Attn:
Address: Title:
City: State: Zip Code: Phone: Fax:
E-mail address:
**Payment is due upon receipt of the invoice. Please remit to the above address and reference your
invoice number on payment.
ROCK ENGINEERING& TESTING LABORATORY,INC.
Corpus Christi San Antonio Round Rock
Office:361.883.4555 Office:210.495.8000 Office:512.284.8022
Fax:361.883.4711 Fax:210.495.8015 Fax:512.284.7764
6817 Leopard St. 10856 Vandale 1 Roundville Ln.
Corpus Christi,TX 78409 San Antonio,TX 78216 Round Rock,TX 78664
www.rocktesting.com
Exhibit A